期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
BES-Ⅱ TOF数据的离线刻度 被引量:3
1
作者 荣刚 赵家伟 +11 位作者 刘琦 薛生田 陈光培 李佩琴 刘靖 毛泽普 李卫国 邱进发 徐春成 谢跃红 袁野 赵海文 《高能物理与核物理》 CSCD 北大核心 2001年第2期154-159,共6页
简要地讨论了北京谱仪-Ⅱ(BES-Ⅱ)飞行时间计数器(TOF)数据的离 线刻度.利用J/φ能区的电子对事例仔细完成的离线刻度与校正结果表明,新的 TOF时间分辨达到σTOF=180ps.由此大大增强了对带电粒子的识别能... 简要地讨论了北京谱仪-Ⅱ(BES-Ⅱ)飞行时间计数器(TOF)数据的离 线刻度.利用J/φ能区的电子对事例仔细完成的离线刻度与校正结果表明,新的 TOF时间分辨达到σTOF=180ps.由此大大增强了对带电粒子的识别能力.对 于3σ的π/K分离其动量可以达到0.93GeV/c. 展开更多
关键词 北京谱仪 飞行时间计数器 数据离线刻度 时间分辨本领 粒子识别
原文传递
Study of MRPC technology for BESIII endcap-TOF upgrade
2
作者 Xin Li Yongjie Sun +18 位作者 Cheng Li Zhen Liu Yuekun Heng Ming Shao Xiaozhuang Wang Zhi Wu Ping Cao Mingming Chen Hongliang Dai Shubing Liu Xiaolan Luo Xiaoshan Jiang Shengsen Sun Zebo Tang Weijia Sun Siyu Wang Meihang Xu Rongxing Yang Kejun Zhu 《Radiation Detection Technology and Methods》 2017年第2期31-36,共6页
Purpose In order to improve the charged particle identi-fication capability,end-cap time-of-flight(ETOF)detector of the Beijing Spectrometer(BESIII)has been upgraded with multi-gap resistive plate chamber(MRPC)technol... Purpose In order to improve the charged particle identi-fication capability,end-cap time-of-flight(ETOF)detector of the Beijing Spectrometer(BESIII)has been upgraded with multi-gap resistive plate chamber(MRPC)technology,aiming at an overall time resolution of 80 ps for minimum-ionization particles to extend the K/πseparation(2σ)momentum range to 1.4 GeV/c.Methods The previous version of ETOF in BESIII consisted of plastic scintillators.The multi-hit events distort both shape and amplitude of the output signals.MRPC technique was chosen for the BESIII ETOF upgrade as it provides high time resolution and high detection efficiency,is of relatively low cost and is insensitive to neutral particles.Most importantly,the fine segmentation of the MRPC readout stripes can suppress multi-hit events effectively.Results The final design of MRPC module for ETOF is characterized by double-stack(2×6)structure,dual-end readout mode and precision electronics.To batch-produce and test these MRPC modules,a series of tools and production procedures as well as related performance simulation and test methods were developed.Results showed that each MRPC module’s intrinsic time resolution(including the electronics contribution)is around 50 ps and the efficiency is better than 97%.The overall performance of the upgraded ETOF is better than the designed index.The new ETOF has been successfully installed at BESIII and run in 2016. 展开更多
关键词 Multi-gap resistive plate chamber Endcap time-of-flight detector Particle identification beijing spectrometer High time resolution
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部