期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Analysis for integrated energy system:Benchmarking methods and implementation
1
作者 Suhan Zhang Wei Gu +4 位作者 X‐PZhang CYChung Ruizhi Yu Shuai Lu Rodrigo Palma‐Behnke 《Energy Internet》 2024年第1期63-80,共18页
The selection of suitable models and solutions is a fundamental requirement for con-ducting energy flow analysis in integrated energy systems(IES).However,this task is challenging due to the vast number of existing mo... The selection of suitable models and solutions is a fundamental requirement for con-ducting energy flow analysis in integrated energy systems(IES).However,this task is challenging due to the vast number of existing models and solutions,making it difficult to comprehensively compare scholars'studies with current work.In this paper,we aim to address this issue by presenting a comprehensive overview of mainstream IES models and clarifying their relationships,thereby providing guidance for scholars in selecting appro-priate models.Additionally,we introduce several widely used solvers for solving algebraic and differential equations,along with their detailed implementations in the energy flow analysis of IES.Furthermore,we conduct extensive testing and demonstration of these models and methods in various cases to establish benchmarking datasets.To facilitate reproducibility,verification and comparisons,we provide open‐source access to these datasets,including system data,analysis settings and implementations of the various solvers in the mainstream models.Scholars can utilise the provided datasets to reproduce the results,verify the findings and perform comparative analyses.Moreover,they have the flexibility to customise these settings according to their specific requirements. 展开更多
关键词 benchmarking method energy flow analysis integrated energy system mainstream model open‐source data
原文传递
Development of A Reference Dose for BDE-47,99,and 209 Using Benchmark Dose Methods
2
作者 LI Lu Xi CHEN Li +5 位作者 CAO Dan CHEN Bing Heng ZHAO Yan MENG Xiang Zhou XIE Chang Ming ZHANG Yun Hui 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第9期733-739,共7页
Eleven recently completed toxicological studies were critically reviewed to identify toxicologically significant endpoints and dose-response information. Dose-response data were compiled and entered into the USEPA's ... Eleven recently completed toxicological studies were critically reviewed to identify toxicologically significant endpoints and dose-response information. Dose-response data were compiled and entered into the USEPA's benchmark dose software (BMDS) for calculation of a benchmark dose (BMD) and a benchmark dose low (BMDL). After assessing 91 endpoints across the nine studies, a total of 23 of these endpoints were identified for BMD modeling, and BMDL estimates corresponding to various dose-response models were compiled for these separate endpoints. Thyroid, neurobehavior and reproductive endpoints for BDE-47, -99, -209 were quantitatively evaluated. According to methods and feature of each study, different uncertainty factor (UF) value was decided and subsequently reference doses (RfDs) were proposed. Consistent with USEPA, the lowest BMDLs of 2.10, 81.77, and 1698 I^g/kg were used to develop RfDs for BDE-47, -99, and -209, respectively. RfDs for BDE-99 and BDE-209 were comparable to EPA results, and however, RfD of BDE-47 was much lower than that of EPA, which may result from that reproductive/developmental proves to be more sensitive than neurobehavior for BDE-47 and the principal study uses very-low-dose exposure. 展开更多
关键词 BDE Development of A Reference Dose for BDE-47 99 and 209 Using Benchmark Dose methods
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部