In order to develop competitive and high performance/cost ratio of digital binoculars, design scheme should be optimized in term of technical capacity, economic benefit, product performance, risk management, etc. The ...In order to develop competitive and high performance/cost ratio of digital binoculars, design scheme should be optimized in term of technical capacity, economic benefit, product performance, risk management, etc. The common optimization method is limited in qualitative analysis, and the parameter optimization method is limited in obtaining optimal parameter only from technical side. Each method has its limitation. Based on the analysis of digital binoculars parameters, optional design schemes are laid down. Analytic hierarchy process combined the qualitative analysis with the quantitative analysis together. The design schemes are optimized, and resuh is worked out.展开更多
Two-dimensional endoscopic images are susceptible to interferences such as specular reflections and monotonous texture illumination,hindering accurate three-dimensional lesion reconstruction by surgical robots.This st...Two-dimensional endoscopic images are susceptible to interferences such as specular reflections and monotonous texture illumination,hindering accurate three-dimensional lesion reconstruction by surgical robots.This study proposes a novel end-to-end disparity estimation model to address these challenges.Our approach combines a Pseudo-Siamese neural network architecture with pyramid dilated convolutions,integrating multi-scale image information to enhance robustness against lighting interferences.This study introduces a Pseudo-Siamese structure-based disparity regression model that simplifies left-right image comparison,improving accuracy and efficiency.The model was evaluated using a dataset of stereo endoscopic videos captured by the Da Vinci surgical robot,comprising simulated silicone heart sequences and real heart video data.Experimental results demonstrate significant improvement in the network’s resistance to lighting interference without substantially increasing parameters.Moreover,the model exhibited faster convergence during training,contributing to overall performance enhancement.This study advances endoscopic image processing accuracy and has potential implications for surgical robot applications in complex environments.展开更多
AIM:To investigate the frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students.METHODS:Totally 158 student volunteers underwent routine visio...AIM:To investigate the frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students.METHODS:Totally 158 student volunteers underwent routine vision examination in the optometry clinic of Guangxi Medical University.Their data were used to identify the different types of accommodation and nonstrabismic binocular vision dysfunction and to determine their frequency.Correlation analysis and logistic regression were used to examine the factors associated with these abnormalities.RESULTS:The results showed that 36.71%of the subjects had accommodation and non-strabismic binocular vision issues,with 8.86%being attributed to accommodation dysfunction and 27.85%to binocular abnormalities.Convergence insufficiency(CI)was the most common abnormality,accounting for 13.29%.Those with these abnormalities experienced higher levels of eyestrain(χ2=69.518,P<0.001).The linear correlations were observed between the difference of binocular spherical equivalent(SE)and the index of horizontal esotropia at a distance(r=0.231,P=0.004)and the asthenopia survey scale(ASS)score(r=0.346,P<0.001).Furthermore,the right eye's SE was inversely correlated with the convergence of positive and negative fusion images at close range(r=-0.321,P<0.001),the convergence of negative fusion images at close range(r=-0.294,P<0.001),the vergence facility(VF;r=-0.234,P=0.003),and the set of negative fusion images at far range(r=-0.237,P=0.003).Logistic regression analysis indicated that gender,age,and the difference in right and binocular SE did not influence the emergence of these abnormalities.CONCLUSION:Binocular vision abnormalities are more prevalent than accommodation dysfunction,with CI being the most frequent type.Greater binocular refractive disparity leads to more severe eyestrain symptoms.展开更多
AIM:To compare the vergence mechanisms between good and poor sleepers in university students.METHODS:A total of 64 university students were recruited in this study.The validated Malay version of Pittsburgh Sleep Quali...AIM:To compare the vergence mechanisms between good and poor sleepers in university students.METHODS:A total of 64 university students were recruited in this study.The validated Malay version of Pittsburgh Sleep Quality Index questionnaire(PSQI-M)was used to measure the participants’sleep quality over the past month.Participants were categorized as good sleepers(n=32)and poor sleepers(n=32)based on the PSQI-M scores.Heterophoria and fusional vergences were measured at distance and near.Mann-Whitney U test was used to compare heterophoria,negative fusional vergence(NFV),and positive fusional vergence(PFV)at distance and near between good and poor sleepers.Spearman correlation analysis was used to study the relationship between PSQI-M score and PFV at distance.RESULTS:Both distance and near heterophorias were not significantly different between good and poor sleepers(P>0.05).There was a difference in distance PFV(P<0.05)between good and poor sleepers,but not in distance NFV,near NFV,and near PFV(P>0.05).Distance PFV was negatively correlated with PSQI-M score(rs=-0.33,P<0.05).CONCLUSION:University students with poor sleep quality demonstrates a reduced ability to maintain fusion with increasing convergence demand at distance.Sleep quality assessment during binocular vision examination in university students is recommended.展开更多
A stereo matching algorithm based on the epipolar line constraint is designed to meet the real-time and the accuracy requirements. The algorithm is applied to photodynamic therapy binocular surveillance system for por...A stereo matching algorithm based on the epipolar line constraint is designed to meet the real-time and the accuracy requirements. The algorithm is applied to photodynamic therapy binocular surveillance system for port wine stain (PWS) when it monitors the position of the treatment region. The corner matching based on Hu moments is used to calculate the fundamental matrix of the binocular vision system. Experimental results are in agreement with the theoretical calculation.展开更多
Cluster warhead has become the main ammunition of gun,rocket projectile and missile and it has been widely equipped in almost every country.More and more attention is paid to the damage effect of cluster warhead.The s...Cluster warhead has become the main ammunition of gun,rocket projectile and missile and it has been widely equipped in almost every country.More and more attention is paid to the damage effect of cluster warhead.The size of the dispersion area of cluster warhead is the main standard by which the damage effect of cluster warhead is estimated.The practical method of measuring the dispersion area was developed based on binocular stereo vision measurement theory.The calibration principle of the binocular stereo vision cameras was studied.The matching algorithm that relies on the gradient fields of the neighborhood of a pixel has been used to obtain the spatial information of matched points by acquiring apair of corresponding points in the left and right images of binocular cameras.The 3Dpositions of the flying path of cluster warhead were calculated.The umbrella that is similar to the dispersion track of static explosive cluster warhead was applied in the experiment to get the projection area of the umbrella on the ground.Experiment results verify the feasibility of the proposed method.展开更多
Current research of binocular vision systems mainly need to resolve the camera’s intrinsic parameters before the reconstruction of three-dimensional(3D)objects.The classical Zhang’calibration is hardly to calculate ...Current research of binocular vision systems mainly need to resolve the camera’s intrinsic parameters before the reconstruction of three-dimensional(3D)objects.The classical Zhang’calibration is hardly to calculate all errors caused by perspective distortion and lens distortion.Also,the image-matching algorithm of the binocular vision system still needs to be improved to accelerate the reconstruction speed of welding pool surfaces.In this paper,a preset coordinate system was utilized for camera calibration instead of Zhang’calibration.The binocular vision system was modified to capture images of welding pool surfaces by suppressing the strong arc interference during gas metal arc welding.Combining and improving the algorithms of speeded up robust features,binary robust invariant scalable keypoints,and KAZE,the feature information of points(i.e.,RGB values,pixel coordinates)was extracted as the feature vector of the welding pool surface.Based on the characteristics of the welding images,a mismatch-elimination algorithm was developed to increase the accuracy of image-matching algorithms.The world coordinates of matching feature points were calculated to reconstruct the 3D shape of the welding pool surface.The effectiveness and accuracy of the reconstruction of welding pool surfaces were verified by experimental results.This research proposes the development of binocular vision algorithms that can reconstruct the surface of welding pools accurately to realize intelligent welding control systems in the future.展开更多
Objective: To investigate the time and postoperative binocular vision of strabismus surgery for children with intermittent exotropia (X(T)). Methods: A retrospective investigation was conducted in 80 child patie...Objective: To investigate the time and postoperative binocular vision of strabismus surgery for children with intermittent exotropia (X(T)). Methods: A retrospective investigation was conducted in 80 child patients with intermittent exotropia. Pre- and postoperative angles of deviation fixating at near (33 cm) and distant targets (6 m) were measured with the prolonged alternate cover testing. The binocular function was assessed with synoptophore. Twenty-one patients took the postoperative synoptophore exercise. Results: (1) A week after surgery, 96.2% of the 80 patients had binocular normotopia, while a year after surgery, 91.3% of the 80 patients had binocular normotopia; (2) Preoperatively, 58 patients had near stereoacuity, while postoperatively, 72 patients achieved near stereoacuity (P〈0.05); (3) Preoperatively, 64 patients had Grade Ⅰ for the synoptophore evaluation and postoperatively, 76 patients achieved Grade Ⅰ. Meanwhile, 55 patients had Grade Ⅱ preoperatively and 72 achieved Grade Ⅱ postoperatively. For Grade Ⅲ, there were 49 patients preoperatively and 64 patients postoperatively (P〈0.05); (4) Patients of 5-8 years old had a significantly better recovery rate of binocular vision than those of 9-18 years old (P〈0.05); (5) Patients taking postoperative synoptophore exercise had a better binocular vision than those taking no exercise (P〈0.05). Conclusions: (1) Strabismus surgery can help to preserve or restore the binocular vision for intermittent exotropia; (2) Receiving the surgery at young ages may develop better postoperative binocular vision; (3) The postoperative synoptophore exercise can help to restore the binocular vision.展开更多
AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (A.sBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: ...AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (A.sBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: One hundred and one VDU users, aged between 20 to 34y, initially participated in the study. This study excluded contact-lens wearers and subjects who had undergone refractive surgery or had any systemic or ocular disease. First, subjects were asked about the type and nature of eye symptoms they experienced during VDU use. Then, a thorough eye examination excluded those subjects with a significant uncorrected refractive error or other problem, such as ocular motility disorders, vertical deviation, strabismus and eye diseases. Finally, the remaining participants underwent an exhaustive assessment of their accommodative and binocular vision status. RESULTS: Eighty-nine VDU users (46 females and 43 males) were included in this study. They used flat-panel displays for an average of 5±1.9h a day. Twenty subjects presented A.sBD (22.5%). Convergence excess was the most frequent non-strabismic binocular dysfunction (9 subjects), followed by fusional vergence dysfunction (3 subjects) and convergence insufficiency (2 subjects). Within the accommodative dysfunctions, accommodative excess was the most common (4 subjects), followed by accommodative insufficiency (2 subjects). Moderate to severe eye symptoms were found in 13 subjects with ANSBD. CONCLUSION: Significant eye symptoms in VDU users with accommodative and/or non-strabismic binocular dysfunctions often occur and should not be underestimated; therefore, an appropriate evaluation of accommodative and binocular vision status is more important for this population,展开更多
An active stereo vision system based on a model of neural pathways of human binocular motor system is proposed. With this model, it is guaranteed that the two cameras of the active stereo vision system can keep their ...An active stereo vision system based on a model of neural pathways of human binocular motor system is proposed. With this model, it is guaranteed that the two cameras of the active stereo vision system can keep their lines of sight fixed on the same target object during smooth pursuit. This feature is very important for active stereo vision systems, since not only 3D reconstruction needs the two cameras have an overlapping field of vision, but also it can facilitate the 3D reconstruction algorithm. To evaluate the effectiveness of the proposed method, some software simulations are done to demonstrate the same target tracking characteristic in a virtual environment apt to mistracking easily. Here, mistracking means two eyes track two different objects separately. Then the proposed method is implemented in our active stereo vision system to perform real tracking task in a laboratory scene where several persons walk self-determining. Before the proposed model is implemented in the system, mistracking occurred frequently. After it is enabled, mistracking never occurred. The result shows that the vision system based on neural pathways of human binocular motor system can reliably avoid mistracking.展开更多
Significant optical engineering advances at the University of Arizona are being made for design, fabrication, and construction of next generation astronomical telescopes. This summary review paper focuses on the techn...Significant optical engineering advances at the University of Arizona are being made for design, fabrication, and construction of next generation astronomical telescopes. This summary review paper focuses on the technological advances in three key areas. First is the optical fabrication technique used for constructing next-generation telescope mirrors. Advances in ground-based telescope control and instrumentation comprise the second area of development. This includes active alignment of the laser truss-based Large Binocular Telescope(LBT) prime focus camera, the new MOBIUS modular cross-dispersion spectroscopy unit used at the prime focal plane of the LBT, and topological pupil segment optimization. Lastly, future space telescope concepts and enabling technologies are discussed. Among these, the Nautilus space observatory requires challenging alignment of segmented multi-order diffractive elements. The OASIS terahertz space telescope presents unique challenges for characterizing the inflatable primary mirror, and the Hyperion space telescope pushes the limits of high spectral resolution, far-UV spectroscopy. The Coronagraphic Debris and Exoplanet Exploring Pioneer(CDEEP) is a Small Satellite(Small Sat) mission concept for high-contrast imaging of circumstellar disks and exoplanets using vector vortex coronagraph. These advances in optical engineering technologies will help mankind to probe, explore, and understand the scientific beauty of our universe.展开更多
AIM: To investigate the effects of micro-injection of botulinum toxin A(BTXA) on acute acquired comitant esotropia(AACE). METHODS: A total of 33 AACE patients who underwent BTXA micro-injection at Renmin Hospital of W...AIM: To investigate the effects of micro-injection of botulinum toxin A(BTXA) on acute acquired comitant esotropia(AACE). METHODS: A total of 33 AACE patients who underwent BTXA micro-injection at Renmin Hospital of Wuhan University from September 1^(st), 2019 to July 1^(st), 2021 were retrospective analyzed. Esotropia, eye alignment, stereopsis, and complications were examined at baseline(except complications), 1wk, 1, 3, and 6mo after injection. RESULTS: The average angle of deviation before injection was(+20.24±6.80)^(Δ) at near and(+24.76±6.43)^(Δ) at distance, while(+5.15±5.85)^(Δ) at near and(+7.30±6.17)^(Δ) at distance 6mo after treatment(P<0.05). Six months after injection, the stereopsis of patients had improved. The number of patients having no stereopsis(>800 seconds of arc) decreased from 11 to 3. The number of patients having peripheral stereopsis(300-800 seconds of arc), macular stereopsis(70-200 seconds of arc) and central concave stereopsis(≤60 seconds of arc) increased from 10 to 11, 10 to 12, and 2 to 7, respectively. At the follow-ups at 1wk, 1, 3, and 6mo after injection, success rates were 96.97%, 96.97%, 93.94% and 87.88%, respectively. One week after injection, two patients(6.07%) showed subconjunctival hemorrhage;three patients(9.09%) showed limited eye movement and one patient(3.03%) showed mild vertical strabismus. All the symptoms disappeared by the final follow-up.CONCLUSION: Micro-injection of BTXA can reduce diplopia and improve binocular vision function of AACE patients. Furthermore, the operation is relatively safe with few complications, making it an ideal treatment modality for AACE.展开更多
This paper presents a pure vision based technique for 3D reconstruction of planet terrain. The reconstruction accuracy depends ultimately on an optimization technique known as 'bundle adjustment'. In vision te...This paper presents a pure vision based technique for 3D reconstruction of planet terrain. The reconstruction accuracy depends ultimately on an optimization technique known as 'bundle adjustment'. In vision techniques, the translation is only known up to a scale factor, and a single scale factor is assumed for the whole sequence of images if only one camera is used. If an extra camera is available, stereo vision based reconstruction can be obtained by binocular views. If the baseline of the stereo setup is known, the scale factor problem is solved. We found that direct application of classical bundle adjustment on the constraints inherent between the binocular views has not been tested. Our method incorporated this constraint into the conventional bundle adjustment method. This special binocular bundle adjustment has been performed on image sequences similar to planet terrain circumstances. Experimental results show that our special method enhances not only the localization accuracy, but also the terrain mapping quality.展开更多
BACKGROUND Medical robot is a promising surgical tool,but no specific one has been designed for interventional treatment of chronic pain.We developed a computed tomography-image based navigation robot using a new regi...BACKGROUND Medical robot is a promising surgical tool,but no specific one has been designed for interventional treatment of chronic pain.We developed a computed tomography-image based navigation robot using a new registration method with binocular vision.This kind of robot is appropriate for minimal invasive interventional procedures and easy to operate.The feasibility,accuracy and stability of this new robot need to be tested.AIM To assess quantitatively the feasibility,accuracy and stability of the binocularstereo-vision-based navigation robot for minimally invasive interventional procedures.METHODS A box model was designed for assessing the accuracy for targets at different distances.Nine(three sets)lead spheres were embedded in the model as puncture goals.The entry-to-target distances were set 50 mm(short-distance),100 mm(medium-distance)and 150 mm(long-distance).Puncture procedure was repeated three times for each goal.The Euclidian error of each puncture was calculated and statistically analyzed.Three head phantoms were used to explore the clinical feasibility and stability.Three independent operators conducted foramen ovale placement on head phantoms(both sides)by freehand or under the guidance of robot(18 punctures with each method).The operation time,adjustment time and one-time success rate were recorded,and the two guidancemethods were compared.RESULTS On the box model,the mean puncture errors of navigation robot were 1.7±0.9 mm for the short-distance target,2.4±1.0 mm for the moderate target and 4.4±1.4 mm for the long-distance target.On the head phantom,no obvious differences in operation time and adjustment time were found among the three performers(P>0.05).The median adjustment time was significantly less under the guidance of the robot than under free hand.The one-time success rate was significantly higher with the robot(P<0.05).There was no obvious difference in operation time between the two methods(P>0.05).CONCLUSION In the laboratory environment,accuracy of binocular-stereo-vision-based navigation robot is acceptable for target at 100 mm depth or less.Compared with freehand,foramen ovale placement accuracy can be improved with robot guidance.展开更多
Propeller blade width measurement has been extensively studied in the past using direct and indirect methods, and it plays a great role in determining the quality of the finished products. It has surveyed that previou...Propeller blade width measurement has been extensively studied in the past using direct and indirect methods, and it plays a great role in determining the quality of the finished products. It has surveyed that previous techniques are usually time-consuming and erroneous due to a large number of points to be processed in blade width measurement. This paper proposes a new method of measuring blade width using two images acquired from different viewpoints of the same blade. And a new feature points matching approach for propeller blade image is proposed in stereo vision measurement. Based on these, pixel coordinates of contour points of the blade in two images are extracted and converted to real world coordinates by image algorithm and binocular stereo machine vision theory. Then, from the real world coordinates, the blade width at any position can be determined by simple geometrical method.展开更多
A method is put forward to realize the recognition and guiding of initial welding position. The weld seams are marked with black lines, which simplify the computational complexity of image processing greatly. A two-ti...A method is put forward to realize the recognition and guiding of initial welding position. The weld seams are marked with black lines, which simplify the computational complexity of image processing greatly. A two-time template matching method has been advanced to search for the target point, which is simple and has higher calculation speed. According to the depth computing principle with the special point matching using binocular stereovision, the initial welding position can be confirmed by calculating the middle point of the perpendicular line of two radials in the space. Taking the welding of propellant fuel container for example, good results are obtained with the algorithms. Finally, similar method for terminating welding position is also advanced.展开更多
AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens (IOL), and to compare with that of Tori...AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens (IOL), and to compare with that of Toric and monofocal IOL implantation.METHODS: All the 30 patients with unilateral astigmatism suffered bilateral cataract were randomly divided into two groups: Toric plus multifocal IOL group and Toric plus monofocal IOL group. Uncorrected and corrected visual acuity at distance (5.0 m), intermediate distance (0.6 m), and near (0.33 m), contrast sensitivity, and stereopsis were assessed 6mo after surgery. Patients were also surveyed for visual disturbances and spectacle dependence.RESULTS: Binocular uncorrected visual acuity (LogMAR) of Toric/multifocal IOL eyes at distance, intermediate, near were 0.05±0.05, 0.24±0.10, and 0.14±0.06 respectively. The values of Toric plus monofocal IOL eyes were 0.06±0.07, 0.26±0.08, and 0.37±0.10 respectively. These values did not indicate significant differences between two groups with exception of near visual acuity. In the photopic condition (with or without glare), the contrast sensitivity of multifocal IOL eyes was significant lower than the monofocal IOL eyes in 18 cpd. In the mesopic condition, the contrast sensitivity of multifocal group was significant lower than monofocal group in 12 cpd, and in mesopic glare condition, this significant difference was found both in 6 cpd and 12 cpd. The stereopsis of Toric/multifocal IOL eyes decreased slightly (100±80 seconds of arc, t=2.222, P=0.136). Mean near vision for patient satisfaction was statistically significantly higher in Toric/multifocal IOL group patients versus than that in Toric/monofocal IOL group (80% vs 25.5%, P=0.000). Visual disturbance was not noticed in either group.CONCLUSION: Although the combination of Toric and multifocal IOL implantation results in compromising stereoacuity, it can still provide patients with high levels of spectacle freedom and good overall binocular visual acuity.展开更多
In nowadays society,the safety of the elderly population is becoming a pressing concern,especially for those who live alone.There might be daily risks such as accidental falling or treatment attack on them.Aiming at t...In nowadays society,the safety of the elderly population is becoming a pressing concern,especially for those who live alone.There might be daily risks such as accidental falling or treatment attack on them.Aiming at these problems,indoor positioning could be a critical way to monitor their states.With the rapidly development of the imaging techniques,wearable and portable cameras are very popular,which could be set on human individual.And in view of the advantages of the visual positioning,the authors propose a binocular visual positioning algorithm to real-timely locate the elderly indoor.In this paper,the imaging model has been established with the corrected image data from the binocular camera;then feature extraction has been completed to provide reference to adjacent image matching based on the binary robust independent elementary feature(BRIEF)descriptor,finally the camera movement and the states of the elderly have been estimated to distinguish their falling risk.In the experiments,the real-sense D435i sensors were adopted as the binocular cameras to obtain indoor images,and three experimental scenarios have been carried out to test the proposed method.The results show that the proposed algorithm can effectively locate the elderly indoor and improve the real-time monitoring capability.展开更多
基金Science and Technology Project of Chongqing Information Industry Bureau(200113013)
文摘In order to develop competitive and high performance/cost ratio of digital binoculars, design scheme should be optimized in term of technical capacity, economic benefit, product performance, risk management, etc. The common optimization method is limited in qualitative analysis, and the parameter optimization method is limited in obtaining optimal parameter only from technical side. Each method has its limitation. Based on the analysis of digital binoculars parameters, optional design schemes are laid down. Analytic hierarchy process combined the qualitative analysis with the quantitative analysis together. The design schemes are optimized, and resuh is worked out.
基金Supported by Sichuan Science and Technology Program(2023YFSY0026,2023YFH0004)Supported by the Institute of Information&Communications Technology Planning&Evaluation(IITP)grant funded by the Korean government(MSIT)(No.RS-2022-00155885,Artificial Intelligence Convergence Innovation Human Resources Development(Hanyang University ERICA)).
文摘Two-dimensional endoscopic images are susceptible to interferences such as specular reflections and monotonous texture illumination,hindering accurate three-dimensional lesion reconstruction by surgical robots.This study proposes a novel end-to-end disparity estimation model to address these challenges.Our approach combines a Pseudo-Siamese neural network architecture with pyramid dilated convolutions,integrating multi-scale image information to enhance robustness against lighting interferences.This study introduces a Pseudo-Siamese structure-based disparity regression model that simplifies left-right image comparison,improving accuracy and efficiency.The model was evaluated using a dataset of stereo endoscopic videos captured by the Da Vinci surgical robot,comprising simulated silicone heart sequences and real heart video data.Experimental results demonstrate significant improvement in the network’s resistance to lighting interference without substantially increasing parameters.Moreover,the model exhibited faster convergence during training,contributing to overall performance enhancement.This study advances endoscopic image processing accuracy and has potential implications for surgical robot applications in complex environments.
基金Supported by the Innovat ion and Entrepreneurship Project for College Students of the First Affiliated Hospital of Guangxi Medical University in 2022 and the Development and Application of Appropriate Medical and Health Technologies in Guangxi(No.S2021093).
文摘AIM:To investigate the frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students.METHODS:Totally 158 student volunteers underwent routine vision examination in the optometry clinic of Guangxi Medical University.Their data were used to identify the different types of accommodation and nonstrabismic binocular vision dysfunction and to determine their frequency.Correlation analysis and logistic regression were used to examine the factors associated with these abnormalities.RESULTS:The results showed that 36.71%of the subjects had accommodation and non-strabismic binocular vision issues,with 8.86%being attributed to accommodation dysfunction and 27.85%to binocular abnormalities.Convergence insufficiency(CI)was the most common abnormality,accounting for 13.29%.Those with these abnormalities experienced higher levels of eyestrain(χ2=69.518,P<0.001).The linear correlations were observed between the difference of binocular spherical equivalent(SE)and the index of horizontal esotropia at a distance(r=0.231,P=0.004)and the asthenopia survey scale(ASS)score(r=0.346,P<0.001).Furthermore,the right eye's SE was inversely correlated with the convergence of positive and negative fusion images at close range(r=-0.321,P<0.001),the convergence of negative fusion images at close range(r=-0.294,P<0.001),the vergence facility(VF;r=-0.234,P=0.003),and the set of negative fusion images at far range(r=-0.237,P=0.003).Logistic regression analysis indicated that gender,age,and the difference in right and binocular SE did not influence the emergence of these abnormalities.CONCLUSION:Binocular vision abnormalities are more prevalent than accommodation dysfunction,with CI being the most frequent type.Greater binocular refractive disparity leads to more severe eyestrain symptoms.
文摘AIM:To compare the vergence mechanisms between good and poor sleepers in university students.METHODS:A total of 64 university students were recruited in this study.The validated Malay version of Pittsburgh Sleep Quality Index questionnaire(PSQI-M)was used to measure the participants’sleep quality over the past month.Participants were categorized as good sleepers(n=32)and poor sleepers(n=32)based on the PSQI-M scores.Heterophoria and fusional vergences were measured at distance and near.Mann-Whitney U test was used to compare heterophoria,negative fusional vergence(NFV),and positive fusional vergence(PFV)at distance and near between good and poor sleepers.Spearman correlation analysis was used to study the relationship between PSQI-M score and PFV at distance.RESULTS:Both distance and near heterophorias were not significantly different between good and poor sleepers(P>0.05).There was a difference in distance PFV(P<0.05)between good and poor sleepers,but not in distance NFV,near NFV,and near PFV(P>0.05).Distance PFV was negatively correlated with PSQI-M score(rs=-0.33,P<0.05).CONCLUSION:University students with poor sleep quality demonstrates a reduced ability to maintain fusion with increasing convergence demand at distance.Sleep quality assessment during binocular vision examination in university students is recommended.
基金Supported by the National High Technology Research and Development Program of China("863"Program)(2007AA04Z231)~~
文摘A stereo matching algorithm based on the epipolar line constraint is designed to meet the real-time and the accuracy requirements. The algorithm is applied to photodynamic therapy binocular surveillance system for port wine stain (PWS) when it monitors the position of the treatment region. The corner matching based on Hu moments is used to calculate the fundamental matrix of the binocular vision system. Experimental results are in agreement with the theoretical calculation.
基金National Major Scientific Equipment Development Projects of China(No.2013YQ240803)Natural Science Foundation for Young Scientists of Shanxi Province(No.2012021011-1)Scientific and Technological Project in Shanxi Province(No.20140321010-02)
文摘Cluster warhead has become the main ammunition of gun,rocket projectile and missile and it has been widely equipped in almost every country.More and more attention is paid to the damage effect of cluster warhead.The size of the dispersion area of cluster warhead is the main standard by which the damage effect of cluster warhead is estimated.The practical method of measuring the dispersion area was developed based on binocular stereo vision measurement theory.The calibration principle of the binocular stereo vision cameras was studied.The matching algorithm that relies on the gradient fields of the neighborhood of a pixel has been used to obtain the spatial information of matched points by acquiring apair of corresponding points in the left and right images of binocular cameras.The 3Dpositions of the flying path of cluster warhead were calculated.The umbrella that is similar to the dispersion track of static explosive cluster warhead was applied in the experiment to get the projection area of the umbrella on the ground.Experiment results verify the feasibility of the proposed method.
基金Supported by National Natural Science Foundation of China(Grant No.51775313)Major Program of Shandong Province Natural Science Foundation(Grant No.ZR2018ZC1760)Young Scholars Program of Shandong University(Grant No.2017WLJH24).
文摘Current research of binocular vision systems mainly need to resolve the camera’s intrinsic parameters before the reconstruction of three-dimensional(3D)objects.The classical Zhang’calibration is hardly to calculate all errors caused by perspective distortion and lens distortion.Also,the image-matching algorithm of the binocular vision system still needs to be improved to accelerate the reconstruction speed of welding pool surfaces.In this paper,a preset coordinate system was utilized for camera calibration instead of Zhang’calibration.The binocular vision system was modified to capture images of welding pool surfaces by suppressing the strong arc interference during gas metal arc welding.Combining and improving the algorithms of speeded up robust features,binary robust invariant scalable keypoints,and KAZE,the feature information of points(i.e.,RGB values,pixel coordinates)was extracted as the feature vector of the welding pool surface.Based on the characteristics of the welding images,a mismatch-elimination algorithm was developed to increase the accuracy of image-matching algorithms.The world coordinates of matching feature points were calculated to reconstruct the 3D shape of the welding pool surface.The effectiveness and accuracy of the reconstruction of welding pool surfaces were verified by experimental results.This research proposes the development of binocular vision algorithms that can reconstruct the surface of welding pools accurately to realize intelligent welding control systems in the future.
基金Project supported by the National Natural Science Foundation of China(No.30600693)Department of Education of Zhejiang Province(No.20030236),China
文摘Objective: To investigate the time and postoperative binocular vision of strabismus surgery for children with intermittent exotropia (X(T)). Methods: A retrospective investigation was conducted in 80 child patients with intermittent exotropia. Pre- and postoperative angles of deviation fixating at near (33 cm) and distant targets (6 m) were measured with the prolonged alternate cover testing. The binocular function was assessed with synoptophore. Twenty-one patients took the postoperative synoptophore exercise. Results: (1) A week after surgery, 96.2% of the 80 patients had binocular normotopia, while a year after surgery, 91.3% of the 80 patients had binocular normotopia; (2) Preoperatively, 58 patients had near stereoacuity, while postoperatively, 72 patients achieved near stereoacuity (P〈0.05); (3) Preoperatively, 64 patients had Grade Ⅰ for the synoptophore evaluation and postoperatively, 76 patients achieved Grade Ⅰ. Meanwhile, 55 patients had Grade Ⅱ preoperatively and 72 achieved Grade Ⅱ postoperatively. For Grade Ⅲ, there were 49 patients preoperatively and 64 patients postoperatively (P〈0.05); (4) Patients of 5-8 years old had a significantly better recovery rate of binocular vision than those of 9-18 years old (P〈0.05); (5) Patients taking postoperative synoptophore exercise had a better binocular vision than those taking no exercise (P〈0.05). Conclusions: (1) Strabismus surgery can help to preserve or restore the binocular vision for intermittent exotropia; (2) Receiving the surgery at young ages may develop better postoperative binocular vision; (3) The postoperative synoptophore exercise can help to restore the binocular vision.
文摘AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (A.sBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: One hundred and one VDU users, aged between 20 to 34y, initially participated in the study. This study excluded contact-lens wearers and subjects who had undergone refractive surgery or had any systemic or ocular disease. First, subjects were asked about the type and nature of eye symptoms they experienced during VDU use. Then, a thorough eye examination excluded those subjects with a significant uncorrected refractive error or other problem, such as ocular motility disorders, vertical deviation, strabismus and eye diseases. Finally, the remaining participants underwent an exhaustive assessment of their accommodative and binocular vision status. RESULTS: Eighty-nine VDU users (46 females and 43 males) were included in this study. They used flat-panel displays for an average of 5±1.9h a day. Twenty subjects presented A.sBD (22.5%). Convergence excess was the most frequent non-strabismic binocular dysfunction (9 subjects), followed by fusional vergence dysfunction (3 subjects) and convergence insufficiency (2 subjects). Within the accommodative dysfunctions, accommodative excess was the most common (4 subjects), followed by accommodative insufficiency (2 subjects). Moderate to severe eye symptoms were found in 13 subjects with ANSBD. CONCLUSION: Significant eye symptoms in VDU users with accommodative and/or non-strabismic binocular dysfunctions often occur and should not be underestimated; therefore, an appropriate evaluation of accommodative and binocular vision status is more important for this population,
文摘An active stereo vision system based on a model of neural pathways of human binocular motor system is proposed. With this model, it is guaranteed that the two cameras of the active stereo vision system can keep their lines of sight fixed on the same target object during smooth pursuit. This feature is very important for active stereo vision systems, since not only 3D reconstruction needs the two cameras have an overlapping field of vision, but also it can facilitate the 3D reconstruction algorithm. To evaluate the effectiveness of the proposed method, some software simulations are done to demonstrate the same target tracking characteristic in a virtual environment apt to mistracking easily. Here, mistracking means two eyes track two different objects separately. Then the proposed method is implemented in our active stereo vision system to perform real tracking task in a laboratory scene where several persons walk self-determining. Before the proposed model is implemented in the system, mistracking occurred frequently. After it is enabled, mistracking never occurred. The result shows that the vision system based on neural pathways of human binocular motor system can reliably avoid mistracking.
基金the Gordon and Betty Moore Foundation for their financial support of the development of the MODElens and its enabling alignment technologiesthe II-VI Foundation Block-Gift,Technology Research Initiative Fund Optics/Imaging Program。
文摘Significant optical engineering advances at the University of Arizona are being made for design, fabrication, and construction of next generation astronomical telescopes. This summary review paper focuses on the technological advances in three key areas. First is the optical fabrication technique used for constructing next-generation telescope mirrors. Advances in ground-based telescope control and instrumentation comprise the second area of development. This includes active alignment of the laser truss-based Large Binocular Telescope(LBT) prime focus camera, the new MOBIUS modular cross-dispersion spectroscopy unit used at the prime focal plane of the LBT, and topological pupil segment optimization. Lastly, future space telescope concepts and enabling technologies are discussed. Among these, the Nautilus space observatory requires challenging alignment of segmented multi-order diffractive elements. The OASIS terahertz space telescope presents unique challenges for characterizing the inflatable primary mirror, and the Hyperion space telescope pushes the limits of high spectral resolution, far-UV spectroscopy. The Coronagraphic Debris and Exoplanet Exploring Pioneer(CDEEP) is a Small Satellite(Small Sat) mission concept for high-contrast imaging of circumstellar disks and exoplanets using vector vortex coronagraph. These advances in optical engineering technologies will help mankind to probe, explore, and understand the scientific beauty of our universe.
基金Supported by the Central Guided Local Science and Technology Development (No.2019ZYYD058)。
文摘AIM: To investigate the effects of micro-injection of botulinum toxin A(BTXA) on acute acquired comitant esotropia(AACE). METHODS: A total of 33 AACE patients who underwent BTXA micro-injection at Renmin Hospital of Wuhan University from September 1^(st), 2019 to July 1^(st), 2021 were retrospective analyzed. Esotropia, eye alignment, stereopsis, and complications were examined at baseline(except complications), 1wk, 1, 3, and 6mo after injection. RESULTS: The average angle of deviation before injection was(+20.24±6.80)^(Δ) at near and(+24.76±6.43)^(Δ) at distance, while(+5.15±5.85)^(Δ) at near and(+7.30±6.17)^(Δ) at distance 6mo after treatment(P<0.05). Six months after injection, the stereopsis of patients had improved. The number of patients having no stereopsis(>800 seconds of arc) decreased from 11 to 3. The number of patients having peripheral stereopsis(300-800 seconds of arc), macular stereopsis(70-200 seconds of arc) and central concave stereopsis(≤60 seconds of arc) increased from 10 to 11, 10 to 12, and 2 to 7, respectively. At the follow-ups at 1wk, 1, 3, and 6mo after injection, success rates were 96.97%, 96.97%, 93.94% and 87.88%, respectively. One week after injection, two patients(6.07%) showed subconjunctival hemorrhage;three patients(9.09%) showed limited eye movement and one patient(3.03%) showed mild vertical strabismus. All the symptoms disappeared by the final follow-up.CONCLUSION: Micro-injection of BTXA can reduce diplopia and improve binocular vision function of AACE patients. Furthermore, the operation is relatively safe with few complications, making it an ideal treatment modality for AACE.
基金the National Natural Science Foundation of China (Nos. 60505017 and 60534070)the Science Planning Project of Zhejiang Province, China (No. 2005C14008)
文摘This paper presents a pure vision based technique for 3D reconstruction of planet terrain. The reconstruction accuracy depends ultimately on an optimization technique known as 'bundle adjustment'. In vision techniques, the translation is only known up to a scale factor, and a single scale factor is assumed for the whole sequence of images if only one camera is used. If an extra camera is available, stereo vision based reconstruction can be obtained by binocular views. If the baseline of the stereo setup is known, the scale factor problem is solved. We found that direct application of classical bundle adjustment on the constraints inherent between the binocular views has not been tested. Our method incorporated this constraint into the conventional bundle adjustment method. This special binocular bundle adjustment has been performed on image sequences similar to planet terrain circumstances. Experimental results show that our special method enhances not only the localization accuracy, but also the terrain mapping quality.
基金Supported by Jiangsu Provincial Department of Science and Technology,No.BE2017603 and No.BE2017675。
文摘BACKGROUND Medical robot is a promising surgical tool,but no specific one has been designed for interventional treatment of chronic pain.We developed a computed tomography-image based navigation robot using a new registration method with binocular vision.This kind of robot is appropriate for minimal invasive interventional procedures and easy to operate.The feasibility,accuracy and stability of this new robot need to be tested.AIM To assess quantitatively the feasibility,accuracy and stability of the binocularstereo-vision-based navigation robot for minimally invasive interventional procedures.METHODS A box model was designed for assessing the accuracy for targets at different distances.Nine(three sets)lead spheres were embedded in the model as puncture goals.The entry-to-target distances were set 50 mm(short-distance),100 mm(medium-distance)and 150 mm(long-distance).Puncture procedure was repeated three times for each goal.The Euclidian error of each puncture was calculated and statistically analyzed.Three head phantoms were used to explore the clinical feasibility and stability.Three independent operators conducted foramen ovale placement on head phantoms(both sides)by freehand or under the guidance of robot(18 punctures with each method).The operation time,adjustment time and one-time success rate were recorded,and the two guidancemethods were compared.RESULTS On the box model,the mean puncture errors of navigation robot were 1.7±0.9 mm for the short-distance target,2.4±1.0 mm for the moderate target and 4.4±1.4 mm for the long-distance target.On the head phantom,no obvious differences in operation time and adjustment time were found among the three performers(P>0.05).The median adjustment time was significantly less under the guidance of the robot than under free hand.The one-time success rate was significantly higher with the robot(P<0.05).There was no obvious difference in operation time between the two methods(P>0.05).CONCLUSION In the laboratory environment,accuracy of binocular-stereo-vision-based navigation robot is acceptable for target at 100 mm depth or less.Compared with freehand,foramen ovale placement accuracy can be improved with robot guidance.
基金Supported by the Natural Science Foundation of China (50975133)the Innovative Foundation for Ph.D of the Jiangsu Province, China (2010-227)
文摘Propeller blade width measurement has been extensively studied in the past using direct and indirect methods, and it plays a great role in determining the quality of the finished products. It has surveyed that previous techniques are usually time-consuming and erroneous due to a large number of points to be processed in blade width measurement. This paper proposes a new method of measuring blade width using two images acquired from different viewpoints of the same blade. And a new feature points matching approach for propeller blade image is proposed in stereo vision measurement. Based on these, pixel coordinates of contour points of the blade in two images are extracted and converted to real world coordinates by image algorithm and binocular stereo machine vision theory. Then, from the real world coordinates, the blade width at any position can be determined by simple geometrical method.
基金This project is supported by National Natural Science Foundation of China(No.60474036) and Shanghai Municipal Science and Technology CommitteeFoundation, China (No.021111116).
文摘A method is put forward to realize the recognition and guiding of initial welding position. The weld seams are marked with black lines, which simplify the computational complexity of image processing greatly. A two-time template matching method has been advanced to search for the target point, which is simple and has higher calculation speed. According to the depth computing principle with the special point matching using binocular stereovision, the initial welding position can be confirmed by calculating the middle point of the perpendicular line of two radials in the space. Taking the welding of propellant fuel container for example, good results are obtained with the algorithms. Finally, similar method for terminating welding position is also advanced.
文摘AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens (IOL), and to compare with that of Toric and monofocal IOL implantation.METHODS: All the 30 patients with unilateral astigmatism suffered bilateral cataract were randomly divided into two groups: Toric plus multifocal IOL group and Toric plus monofocal IOL group. Uncorrected and corrected visual acuity at distance (5.0 m), intermediate distance (0.6 m), and near (0.33 m), contrast sensitivity, and stereopsis were assessed 6mo after surgery. Patients were also surveyed for visual disturbances and spectacle dependence.RESULTS: Binocular uncorrected visual acuity (LogMAR) of Toric/multifocal IOL eyes at distance, intermediate, near were 0.05±0.05, 0.24±0.10, and 0.14±0.06 respectively. The values of Toric plus monofocal IOL eyes were 0.06±0.07, 0.26±0.08, and 0.37±0.10 respectively. These values did not indicate significant differences between two groups with exception of near visual acuity. In the photopic condition (with or without glare), the contrast sensitivity of multifocal IOL eyes was significant lower than the monofocal IOL eyes in 18 cpd. In the mesopic condition, the contrast sensitivity of multifocal group was significant lower than monofocal group in 12 cpd, and in mesopic glare condition, this significant difference was found both in 6 cpd and 12 cpd. The stereopsis of Toric/multifocal IOL eyes decreased slightly (100±80 seconds of arc, t=2.222, P=0.136). Mean near vision for patient satisfaction was statistically significantly higher in Toric/multifocal IOL group patients versus than that in Toric/monofocal IOL group (80% vs 25.5%, P=0.000). Visual disturbance was not noticed in either group.CONCLUSION: Although the combination of Toric and multifocal IOL implantation results in compromising stereoacuity, it can still provide patients with high levels of spectacle freedom and good overall binocular visual acuity.
基金This work was supported by the National Natural Science Foundation of China(No.61803203).
文摘In nowadays society,the safety of the elderly population is becoming a pressing concern,especially for those who live alone.There might be daily risks such as accidental falling or treatment attack on them.Aiming at these problems,indoor positioning could be a critical way to monitor their states.With the rapidly development of the imaging techniques,wearable and portable cameras are very popular,which could be set on human individual.And in view of the advantages of the visual positioning,the authors propose a binocular visual positioning algorithm to real-timely locate the elderly indoor.In this paper,the imaging model has been established with the corrected image data from the binocular camera;then feature extraction has been completed to provide reference to adjacent image matching based on the binary robust independent elementary feature(BRIEF)descriptor,finally the camera movement and the states of the elderly have been estimated to distinguish their falling risk.In the experiments,the real-sense D435i sensors were adopted as the binocular cameras to obtain indoor images,and three experimental scenarios have been carried out to test the proposed method.The results show that the proposed algorithm can effectively locate the elderly indoor and improve the real-time monitoring capability.