As the risks associated with air turbulence are intensified by climate change and the growth of the aviation industry,it has become imperative to monitor and mitigate these threats to ensure civil aviation safety.The ...As the risks associated with air turbulence are intensified by climate change and the growth of the aviation industry,it has become imperative to monitor and mitigate these threats to ensure civil aviation safety.The eddy dissipation rate(EDR)has been established as the standard metric for quantifying turbulence in civil aviation.This study aims to explore a universally applicable symbolic classification approach based on genetic programming to detect turbulence anomalies using quick access recorder(QAR)data.The detection of atmospheric turbulence is approached as an anomaly detection problem.Comparative evaluations demonstrate that this approach performs on par with direct EDR calculation methods in identifying turbulence events.Moreover,comparisons with alternative machine learning techniques indicate that the proposed technique is the optimal methodology currently available.In summary,the use of symbolic classification via genetic programming enables accurate turbulence detection from QAR data,comparable to that with established EDR approaches and surpassing that achieved with machine learning algorithms.This finding highlights the potential of integrating symbolic classifiers into turbulence monitoring systems to enhance civil aviation safety amidst rising environmental and operational hazards.展开更多
Thanks to the strong perpendicular magnetic anisotropy(PMA), excellent processing compatibility as well as novel spintronic phenomenon, Co/Pt multilayers have been attracting massive attention and widely used in magne...Thanks to the strong perpendicular magnetic anisotropy(PMA), excellent processing compatibility as well as novel spintronic phenomenon, Co/Pt multilayers have been attracting massive attention and widely used in magnetic storage.However, reversed magnetic domains come into being with the increasing layer repetition ‘N’ to reduce magneto-static energy, resulting in the remarkable diminishment of the remanent magnetization(Mr). As a result, the product of Mrand thickness(i.e., the remanent moment-thickness product, Mrt), a key parameter in magnetic recording for reliable data storing and reading, also decreases dramatically. To overcome this issue, we deposit an ultra-thick granular [Co/Pt]80multilayer with a total thickness of 68 nm on granular SiNxbuffer layer. The Mrt value, Mrto saturation magnetization(Ms) ratio as well as out of plane(OOP) coercivity(Hcoop) are high up to 2.97 memu/cm^(2), 67%, and 1940 Oe(1 Oe = 79.5775 A·m^(-1)),respectively, which is remarkably improved compared with that of continuous [Co/Pt]80multilayers. That is because large amounts of grain boundaries in the granular multilayers can efficiently impede the propagation and expansion of reversed magnetic domains, which is verified by experimental investigations and micromagnetic simulation results. The simulation results also indicate that the value of Mrt, Mr/Msratio, and Hcoopcan be further improved through optimizing the granule size, which can be experimentally realized by manipulating the process parameter of SiNxbuffer layer. This work provides an alternative solution for achieving high Mrt value in ultra-thick Co/Pt multilayers, which is of unneglectable potential in applications of high-density magnetic recording.展开更多
AIM:To establish a recording system with a direct view of the surgeon to supplement video recording under an operating microscope,which lacks information on the movement and position of the surgeon’s hands,and to fac...AIM:To establish a recording system with a direct view of the surgeon to supplement video recording under an operating microscope,which lacks information on the movement and position of the surgeon’s hands,and to facilitate the reproduction of a skilled surgeon’s technique by a surgeon in training.METHODS:A small camera was attached to the operating microscope with a custom adapter.Microscopic surgeon’s view and direct surgeon’s view through this new camera were recorded in the surgical recording system.Both movies were synchronized and analyzed how do surgeons handle the instruments.RESULTS:A small camera attached to the operating microscope allowed the surgeon’s hands motion to be recorded without interfering with the surgeon’s movements.Different surgeons used different methods to manipulate the ultrasound handpiece and the irrigation/aspiration device.Even in the simple paracentesis procedure,different surgeons used different methods.Surgeons-in-training were able to identify and improve their weaknesses by watching synchronized movies of their hand motions and microscopic view.CONCLUSION:Simultaneous recording the surgical field out of the operating microscopic view by a small camera set on the microscope is comprehensive and improves surgeons-in-training understanding and learning surgeries.展开更多
Chrysosplenium fallax Koldaeva,recently discovered and collected in Yanji,Jilin Province,repre-sents a newly recorded species of Saxifragaceae in China.This species,native to the Russian Far East,was first described a...Chrysosplenium fallax Koldaeva,recently discovered and collected in Yanji,Jilin Province,repre-sents a newly recorded species of Saxifragaceae in China.This species,native to the Russian Far East,was first described as a new species in 2021.Based on precise field investigations and specimen examination,we provide a comprehensive description of C.fallax and its seed micromorphology.Phylogenetic analysis based on chloroplast genomes of 45 Chrysosplenium species confirmed the systematic position of C.fallax in Chrysosplenium.Voucher specimens were deposited in the Herbarium of South-Central Minzu University(HSN).展开更多
Due to the complexity and variability of carbonate formation leakage zones, lost circulation prediction and control is one of the major challenges of carbonate drilling. It raises well-control risks and production exp...Due to the complexity and variability of carbonate formation leakage zones, lost circulation prediction and control is one of the major challenges of carbonate drilling. It raises well-control risks and production expenses. This research utilizes the H oilfield as an example, employs seismic features to analyze mud loss prediction, and produces a complete set of pre-drilling mud loss prediction solutions. Firstly, 16seismic attributes are calculated based on the post-stack seismic data, and the mud loss rate per unit footage is specified. The sample set is constructed by extracting each attribute from the seismic trace surrounding 15 typical wells, with a ratio of 8:2 between the training set and the test set. With the calibration results for mud loss rate per unit footage, the nonlinear mapping relationship between seismic attributes and mud loss rate per unit size is established using the mixed density network model.Then, the influence of the number of sub-Gausses and the uncertainty coefficient on the model's prediction is evaluated. Finally, the model is used in conjunction with downhole drilling conditions to assess the risk of mud loss in various layers and along the wellbore trajectory. The study demonstrates that the mean relative errors of the model for training data and test data are 6.9% and 7.5%, respectively, and that R2is 90% and 88%, respectively, for training data and test data. The accuracy and efficacy of mud loss prediction may be greatly enhanced by combining 16 seismic attributes with the mud loss rate per unit footage and applying machine learning methods. The mud loss prediction model based on the MDN model can not only predict the mud loss rate but also objectively evaluate the prediction based on the quality of the data and the model.展开更多
One specimen belonging to the family Comatellinae was collected from the Zhenbei Seamount(332.5–478.2 m)in the South China Sea in July 2022.Based on the morphological characters,the specimen was identified as Palaeoc...One specimen belonging to the family Comatellinae was collected from the Zhenbei Seamount(332.5–478.2 m)in the South China Sea in July 2022.Based on the morphological characters,the specimen was identified as Palaeocomatella hiwia McKnight,1977.It is first recorded from China Sea and redescribed in detail.This specimen differs from the original description from New Zealand for never showing syzygy at br4+5 or br5+6 on interior and br1+2 on exterior arms.However,it is much conform to the redescription to specimens from Indonesia,with only differences in position of the second syzygy and distalmost pinnule comb.Specimen is deposited in the Institute of Oceanology,Chinese Academy of Sciences.Phylogenetic analyses based on the mitochondrial c oxidase subunit I(COI)and 16S rRNA genes indicated that P.hiwia was nested within the tribe Phanogeniini and clustered with Aphanocomaster pulcher.Furthermore,P.hiwia showed same morphological features in terms of mouth placement,comb location,and number of comb teeth rows as other genera of Phanogeniini.Therefore,we suggest that the genus Palaeocomatella should be put in the tribe Phanogeniini.展开更多
Background: Nursing records play an important role in multidisciplinary collaborations in delirium care. This study aims to develop a self-rated nursing record frequency scale for delirium care among nurses in acute c...Background: Nursing records play an important role in multidisciplinary collaborations in delirium care. This study aims to develop a self-rated nursing record frequency scale for delirium care among nurses in acute care hospitals (NRDC-Acute). Methods: A draft of the scale was developed after a literature review and meeting with researchers with experience in delirium care, and a master’s or doctoral degree in nursing. We identified 25 items on a 5-point Likert scale. Subsequently, an anonymous self-administered questionnaire survey was administered to 520 nurses from 41 acute care hospitals in Japan, and the reliability and validity of the scale were examined. Results: There were 232 (44.6%) respondents and 218 (41.9%) valid responses. The mean duration of clinical experience was 15.2 years (SD = 8.8). Exploratory factor analysis extracted 4 factors and 13 items for this scale. The model fit indices were GFI = 0.991, AGFI = 0.986, and SRMR = 0.046. The Cronbach’s alpha coefficient for the entire scale was .888. The four factors were named “Record of Pharmacological Delirium Care on Pro Re Nata (PRN)”, “Record of Non-Pharmacological Delirium Care”, “Record of Pharmacological Delirium Care on Regular Medication”, and “Record of Collaboration for Delirium Care”. Conclusion: The scale was relatively reliable and valid. Nurses in acute care hospitals can use this scale to identify and address issues related to the documentation of nursing records for delirium care.展开更多
Research on the use of EHR is contradictory since it presents contradicting results regarding the time spent documenting. There is research that supports the use of electronic records as a tool to speed documentation;...Research on the use of EHR is contradictory since it presents contradicting results regarding the time spent documenting. There is research that supports the use of electronic records as a tool to speed documentation;and research that found that it is time consuming. The purpose of this quantitative retrospective before-after project was to measure the impact of using the laboratory value flowsheet within the EHR on documentation time. The research question was: “Does the use of a laboratory value flowsheet in the EHR impact documentation time by primary care providers (PCPs)?” The theoretical framework utilized in this project was the Donabedian Model. The population in this research was the two PCPs in a small primary care clinic in the northwest of Puerto Rico. The sample was composed of all the encounters during the months of October 2019 and December 2019. The data was obtained through data mining and analyzed using SPSS 27. The evaluative outcome of this project is that there is a decrease in documentation time after implementation of the use of the laboratory value flowsheet in the EHR. However, patients per day increase therefore having an impact on the number of patients seen per day/week/month. The implications for clinical practice include the use of templates to improve workflow and documentation as well as decreasing documentation time while also increasing the number of patients seen per day. .展开更多
The key point in studying or teaching the history of Chinese medicine is on the doctrines underlying it and on its perception of the body,physiology,pathology,and its treatment.Namely,there is often a tendency to focu...The key point in studying or teaching the history of Chinese medicine is on the doctrines underlying it and on its perception of the body,physiology,pathology,and its treatment.Namely,there is often a tendency to focus on reading and analysing the classical canons and therapy-related texts including formularies and materia medica collections.However,focusing on these sources provides us with a one-sided presentation of Chinese medicine.These primary sources lack the clinical down-to-earth know-how that encompasses medical treatment,which are represented,for instance,in the clinical rounds of modern medical schools.Our traditional focus on the medical canons and formularies provides almost no clinical knowledge,leaving us with a one-sided narrative that ignores how medicine and healing are actually practiced in the field.This paper focuses on the latter aspect of medicine from a historical perspective.Using written and visual sources dating to the Song dynasty,clinical encounters between doctors and patients including their families are depicted based on case records recorded by a physician,members of the patient’s family,and bystanders.This array of case records or case stories will enable us to narrate the interaction between physicians and patients both from the clinical perspective and from the social interaction.This paper will also discuss visual depictions of the medical encounter to provide another perspective for narrating medicine during the Song dynasty.Medical case records and paintings depicting medical encounters are exemplary of the potential of Chinese primary sources for narrative medicine.展开更多
The authors used suspension cells of Populus euphratica to isolate protoplast in the present study. Protoplasts were successfully obtained after 4 hours incubation in enzyme solution containing 1 0% cellulase “o...The authors used suspension cells of Populus euphratica to isolate protoplast in the present study. Protoplasts were successfully obtained after 4 hours incubation in enzyme solution containing 1 0% cellulase “onozuka” R\|10, 0\^01% pectolyase Y\|23,0\^15% macerozyme R\|10 and 0\^1% hemicellulase at 25℃. Outward and inward single channels in plasma membrane were observed using cell\|attached recording of patch\|clamp technique. In this study, single channel records showed that more than one species of channel were obtained. These attempts in protoplast isolation and ion channel recording offers the opportunity to characterize cellular mechanisms of salt tolerance in tree species.展开更多
In this paper a fault location and recording system based on a computer network is presented. A brief description of the system structure and main features are given. Emphasis is placed on the accurate fault location ...In this paper a fault location and recording system based on a computer network is presented. A brief description of the system structure and main features are given. Emphasis is placed on the accurate fault location method for extra high voltage and long distance transmission lines.展开更多
A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair ...A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair consists of one stimulating electrode and one recording electrode. Supported by the peripheral circuits, four electrode states to study the bioelectrical signal of biological tissue or slice cultured in-vitro on the surface of the electrodes can be realized through each pair of electrodes. The four electrode states are stimulation, recording, stimulation and recording simultaneously, and isolation. The state of each pair of working electrodes can be arbitrarily controlled according to actual needs. The MEAs are fabricated in printed circuit board (PCB) technology. The total area of the PCB-based MEA is 49 mm × 49 mm. The impedance measurement of MEA is carried out in 0.9% sodium chloride solution at room temperature by means of 2-point measurements with an Agilent LCR meter, and the test signal for the impedance measurement is sinusoidal (AC voltage 50 mV, sweeping frequency 20 Hz to 10 kHz). The electrode impedance is between 200 and 3 kΩ while the frequency is between 500 and 1 000 Hz. The electrode impedance magnitude is inversely proportional to the frequency. Experiments of toad sciatic nerve in-vitro stimulation and recording and signal regeneration between isolated toad sciatic nerves are carried out on the PCB-based MEA. The results show that the MEA can be used for bioelectrical signal stimulation, recording, stimulation and recording simultaneously, and isolation of biological tissues or slices in-vitro.展开更多
Objective To re-confirm and characterize the biophysical and pharmacological properties of endogenously expressed human acid-sensing ion channel 1a (hASIC1a) current in HEK293 cells with a modified perfusion methods...Objective To re-confirm and characterize the biophysical and pharmacological properties of endogenously expressed human acid-sensing ion channel 1a (hASIC1a) current in HEK293 cells with a modified perfusion methods. Methods With cell floating method, which is separating the cultured cell from coverslip and putting the cell in front of perfusion tubing, whole cell patch clamp technique was used to record hASICla currents evoked by low pH external solution. Results Using cell floating method, the amplitude of hASICla currents activated by pH 5.0 in HEK293 cells is twice as large as that by the conventional method where the cells remain attached to coverslip. The time to reach peak at two different recording conditions is (21±5) ms and (270±25) ms, respectively. Inactivation time constants are (496±23) ms and (2284±120) ms, respectively. The cell floating method significantly increases the amiloride potency of block on hASIC 1 a [IC50 is (3.4± 1.1 ) μmol/L and (2.4± 0.9) μmol/L, respectively]. Both recording methods have similar pH activation ECs0 (6.6±0.6, 6.6±0.7, respectively). Conclusion ASICs channel activation requires fast exchange of extracellular solution with the different pH values. With cell floating method, the presence of hASIC la current was re-confirmed and the biophysical and pharmacological properties of hASIC la channel in HEK293 cells was precisely characterized. This method could be used to study all ASICs and other ligand-gated channels that require fast extracellular solution exchange.展开更多
The National Strong Motion Observation Network System (NSMONS) of China is briefly introduced in this paper. The NSMONS consists of permanent free-field stations, special observation arrays, mobile observatories and...The National Strong Motion Observation Network System (NSMONS) of China is briefly introduced in this paper. The NSMONS consists of permanent free-field stations, special observation arrays, mobile observatories and a network management system. During the Wenchuan Earthquake, over 1,400 components of acceleration records were obtained from 460 permanent free-field stations and three arrays for topographical effect and structural response observation in the network system from the main shock, and over 20,000 components of acceleration records from strong aftershocks occurred before August 1, 2008 were also obtained by permanent free-field stations of the NSMONS and 59 mobile instruments quickly deployed after the main shock. The strong motion recordings from the main shock and strong aftershocks are summarized in this paper. In the ground motion recordings, there are over 560 components with peak ground acceleration (PGA) over 10 Gal, the largest being 957.7 Gal. The largest PGA recorded during the aftershock exceeds 300 Gal.展开更多
Local site conditions play an important role in the effective application of strong motion recordings.In the China National Strong Motion Observation Network System(NSMONS),some of the stations do not provide boreho...Local site conditions play an important role in the effective application of strong motion recordings.In the China National Strong Motion Observation Network System(NSMONS),some of the stations do not provide borehole information,and correspondingly,do not assign the site classes yet.In this paper,site classification methodologies for free-field strong motion stations are reviewed and the limitations and uncertainties of the horizontal-to-vertical spectral ratio(HVSR) methods are discussed.Then,a new method for site classification based on the entropy weight theory is proposed.The proposed method avoids the head or tail joggle phenomenon by providing the objective and subjective weights.The method was applied to aftershock recordings from the 2008 Wenchuan earthquake,and 54 free-field NSMONS stations were selected for site classification and the mean HVSRs were calculated.The results show that the improved HVSR method proposed in this paper has a higher success rate and could be adopted in NSMONS.展开更多
The thickness of CoP thin films prepared by wet chemical deposition is of crucial importance on magnetic property and recording perform-ance. The coercivity of CoP films decreased with increasing film thickness. The c...The thickness of CoP thin films prepared by wet chemical deposition is of crucial importance on magnetic property and recording perform-ance. The coercivity of CoP films decreased with increasing film thickness. The coercivity was 45.37 kA m 1 at the thickness of 300 nm, and decreased to 21.65 kA m 1 at 5.7 μm. Recording performance tests indicate that, for drums with the same size, different recorded magnetic pole density have different thickness requirements. For 40 mm diameter magnetic drum, the optimal CoP thickness is 3~10 μm for 256 re-corded magnetic poles, 1~2 μm for 512 recorded magnetic poles, and 500~800 nm for 1024 recorded magnetic poles.展开更多
Current practice uses predictive models to extrapolate long-period response spectra based on far-field recordings in moderate and weak earthquakes. However, the spectra are not long enough and the data are often not r...Current practice uses predictive models to extrapolate long-period response spectra based on far-field recordings in moderate and weak earthquakes. However, the spectra are not long enough and the data are often not reliable, which means that the seismic design code cannot accurately define seismic design requirements for long-period structures. The near-field recordings in the main-shock of the Chi-Chi earthquake have a large signal-to-noise ratio (SNR), which makes them suitable for studying the long-period acceleration response spectrum up to 20 sec. The acceleration response spectra from 246 stations within 120 km of the causative fault are statistically analyzed in this paper. The influence of distance and site conditions on long-period response spectrum is discussed, and the shapes of the amplification spectra are compared with the standard spectra specified in the seismic design code of China. Finally, suggestions for future revisions to the code are proposed.展开更多
基金supported by the Meteorological Soft Science Project(Grant No.2023ZZXM29)the Natural Science Fund Project of Tianjin,China(Grant No.21JCYBJC00740)the Key Research and Development-Social Development Program of Jiangsu Province,China(Grant No.BE2021685).
文摘As the risks associated with air turbulence are intensified by climate change and the growth of the aviation industry,it has become imperative to monitor and mitigate these threats to ensure civil aviation safety.The eddy dissipation rate(EDR)has been established as the standard metric for quantifying turbulence in civil aviation.This study aims to explore a universally applicable symbolic classification approach based on genetic programming to detect turbulence anomalies using quick access recorder(QAR)data.The detection of atmospheric turbulence is approached as an anomaly detection problem.Comparative evaluations demonstrate that this approach performs on par with direct EDR calculation methods in identifying turbulence events.Moreover,comparisons with alternative machine learning techniques indicate that the proposed technique is the optimal methodology currently available.In summary,the use of symbolic classification via genetic programming enables accurate turbulence detection from QAR data,comparable to that with established EDR approaches and surpassing that achieved with machine learning algorithms.This finding highlights the potential of integrating symbolic classifiers into turbulence monitoring systems to enhance civil aviation safety amidst rising environmental and operational hazards.
基金supported by the National Natural Science Foundation of China (Grant No. 51901008)the National Key Research and Development Program of China (Grant No. 2021YFB3201800)。
文摘Thanks to the strong perpendicular magnetic anisotropy(PMA), excellent processing compatibility as well as novel spintronic phenomenon, Co/Pt multilayers have been attracting massive attention and widely used in magnetic storage.However, reversed magnetic domains come into being with the increasing layer repetition ‘N’ to reduce magneto-static energy, resulting in the remarkable diminishment of the remanent magnetization(Mr). As a result, the product of Mrand thickness(i.e., the remanent moment-thickness product, Mrt), a key parameter in magnetic recording for reliable data storing and reading, also decreases dramatically. To overcome this issue, we deposit an ultra-thick granular [Co/Pt]80multilayer with a total thickness of 68 nm on granular SiNxbuffer layer. The Mrt value, Mrto saturation magnetization(Ms) ratio as well as out of plane(OOP) coercivity(Hcoop) are high up to 2.97 memu/cm^(2), 67%, and 1940 Oe(1 Oe = 79.5775 A·m^(-1)),respectively, which is remarkably improved compared with that of continuous [Co/Pt]80multilayers. That is because large amounts of grain boundaries in the granular multilayers can efficiently impede the propagation and expansion of reversed magnetic domains, which is verified by experimental investigations and micromagnetic simulation results. The simulation results also indicate that the value of Mrt, Mr/Msratio, and Hcoopcan be further improved through optimizing the granule size, which can be experimentally realized by manipulating the process parameter of SiNxbuffer layer. This work provides an alternative solution for achieving high Mrt value in ultra-thick Co/Pt multilayers, which is of unneglectable potential in applications of high-density magnetic recording.
文摘AIM:To establish a recording system with a direct view of the surgeon to supplement video recording under an operating microscope,which lacks information on the movement and position of the surgeon’s hands,and to facilitate the reproduction of a skilled surgeon’s technique by a surgeon in training.METHODS:A small camera was attached to the operating microscope with a custom adapter.Microscopic surgeon’s view and direct surgeon’s view through this new camera were recorded in the surgical recording system.Both movies were synchronized and analyzed how do surgeons handle the instruments.RESULTS:A small camera attached to the operating microscope allowed the surgeon’s hands motion to be recorded without interfering with the surgeon’s movements.Different surgeons used different methods to manipulate the ultrasound handpiece and the irrigation/aspiration device.Even in the simple paracentesis procedure,different surgeons used different methods.Surgeons-in-training were able to identify and improve their weaknesses by watching synchronized movies of their hand motions and microscopic view.CONCLUSION:Simultaneous recording the surgical field out of the operating microscopic view by a small camera set on the microscope is comprehensive and improves surgeons-in-training understanding and learning surgeries.
文摘Chrysosplenium fallax Koldaeva,recently discovered and collected in Yanji,Jilin Province,repre-sents a newly recorded species of Saxifragaceae in China.This species,native to the Russian Far East,was first described as a new species in 2021.Based on precise field investigations and specimen examination,we provide a comprehensive description of C.fallax and its seed micromorphology.Phylogenetic analysis based on chloroplast genomes of 45 Chrysosplenium species confirmed the systematic position of C.fallax in Chrysosplenium.Voucher specimens were deposited in the Herbarium of South-Central Minzu University(HSN).
基金the financially supported by the National Natural Science Foundation of China(Grant No.52104013)the China Postdoctoral Science Foundation(Grant No.2022T150724)。
文摘Due to the complexity and variability of carbonate formation leakage zones, lost circulation prediction and control is one of the major challenges of carbonate drilling. It raises well-control risks and production expenses. This research utilizes the H oilfield as an example, employs seismic features to analyze mud loss prediction, and produces a complete set of pre-drilling mud loss prediction solutions. Firstly, 16seismic attributes are calculated based on the post-stack seismic data, and the mud loss rate per unit footage is specified. The sample set is constructed by extracting each attribute from the seismic trace surrounding 15 typical wells, with a ratio of 8:2 between the training set and the test set. With the calibration results for mud loss rate per unit footage, the nonlinear mapping relationship between seismic attributes and mud loss rate per unit size is established using the mixed density network model.Then, the influence of the number of sub-Gausses and the uncertainty coefficient on the model's prediction is evaluated. Finally, the model is used in conjunction with downhole drilling conditions to assess the risk of mud loss in various layers and along the wellbore trajectory. The study demonstrates that the mean relative errors of the model for training data and test data are 6.9% and 7.5%, respectively, and that R2is 90% and 88%, respectively, for training data and test data. The accuracy and efficacy of mud loss prediction may be greatly enhanced by combining 16 seismic attributes with the mud loss rate per unit footage and applying machine learning methods. The mud loss prediction model based on the MDN model can not only predict the mud loss rate but also objectively evaluate the prediction based on the quality of the data and the model.
基金the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB42000000)the Key Program of National Natural Science Foundation of China(No.41930533)+1 种基金the Chinese Academy of Sciences Pioneer Hundred Talents Program(to Nansheng CHEN)the Taishan Scholar Project Special Fund(to Nansheng CHEN)。
文摘One specimen belonging to the family Comatellinae was collected from the Zhenbei Seamount(332.5–478.2 m)in the South China Sea in July 2022.Based on the morphological characters,the specimen was identified as Palaeocomatella hiwia McKnight,1977.It is first recorded from China Sea and redescribed in detail.This specimen differs from the original description from New Zealand for never showing syzygy at br4+5 or br5+6 on interior and br1+2 on exterior arms.However,it is much conform to the redescription to specimens from Indonesia,with only differences in position of the second syzygy and distalmost pinnule comb.Specimen is deposited in the Institute of Oceanology,Chinese Academy of Sciences.Phylogenetic analyses based on the mitochondrial c oxidase subunit I(COI)and 16S rRNA genes indicated that P.hiwia was nested within the tribe Phanogeniini and clustered with Aphanocomaster pulcher.Furthermore,P.hiwia showed same morphological features in terms of mouth placement,comb location,and number of comb teeth rows as other genera of Phanogeniini.Therefore,we suggest that the genus Palaeocomatella should be put in the tribe Phanogeniini.
文摘Background: Nursing records play an important role in multidisciplinary collaborations in delirium care. This study aims to develop a self-rated nursing record frequency scale for delirium care among nurses in acute care hospitals (NRDC-Acute). Methods: A draft of the scale was developed after a literature review and meeting with researchers with experience in delirium care, and a master’s or doctoral degree in nursing. We identified 25 items on a 5-point Likert scale. Subsequently, an anonymous self-administered questionnaire survey was administered to 520 nurses from 41 acute care hospitals in Japan, and the reliability and validity of the scale were examined. Results: There were 232 (44.6%) respondents and 218 (41.9%) valid responses. The mean duration of clinical experience was 15.2 years (SD = 8.8). Exploratory factor analysis extracted 4 factors and 13 items for this scale. The model fit indices were GFI = 0.991, AGFI = 0.986, and SRMR = 0.046. The Cronbach’s alpha coefficient for the entire scale was .888. The four factors were named “Record of Pharmacological Delirium Care on Pro Re Nata (PRN)”, “Record of Non-Pharmacological Delirium Care”, “Record of Pharmacological Delirium Care on Regular Medication”, and “Record of Collaboration for Delirium Care”. Conclusion: The scale was relatively reliable and valid. Nurses in acute care hospitals can use this scale to identify and address issues related to the documentation of nursing records for delirium care.
文摘Research on the use of EHR is contradictory since it presents contradicting results regarding the time spent documenting. There is research that supports the use of electronic records as a tool to speed documentation;and research that found that it is time consuming. The purpose of this quantitative retrospective before-after project was to measure the impact of using the laboratory value flowsheet within the EHR on documentation time. The research question was: “Does the use of a laboratory value flowsheet in the EHR impact documentation time by primary care providers (PCPs)?” The theoretical framework utilized in this project was the Donabedian Model. The population in this research was the two PCPs in a small primary care clinic in the northwest of Puerto Rico. The sample was composed of all the encounters during the months of October 2019 and December 2019. The data was obtained through data mining and analyzed using SPSS 27. The evaluative outcome of this project is that there is a decrease in documentation time after implementation of the use of the laboratory value flowsheet in the EHR. However, patients per day increase therefore having an impact on the number of patients seen per day/week/month. The implications for clinical practice include the use of templates to improve workflow and documentation as well as decreasing documentation time while also increasing the number of patients seen per day. .
基金This study is financed by the grants from Israel Science Foundation(No.ISF-1199/16)Chiang Ching-kuo Foundation for International Scholarly Exchange(No.RG001-U-19).
文摘The key point in studying or teaching the history of Chinese medicine is on the doctrines underlying it and on its perception of the body,physiology,pathology,and its treatment.Namely,there is often a tendency to focus on reading and analysing the classical canons and therapy-related texts including formularies and materia medica collections.However,focusing on these sources provides us with a one-sided presentation of Chinese medicine.These primary sources lack the clinical down-to-earth know-how that encompasses medical treatment,which are represented,for instance,in the clinical rounds of modern medical schools.Our traditional focus on the medical canons and formularies provides almost no clinical knowledge,leaving us with a one-sided narrative that ignores how medicine and healing are actually practiced in the field.This paper focuses on the latter aspect of medicine from a historical perspective.Using written and visual sources dating to the Song dynasty,clinical encounters between doctors and patients including their families are depicted based on case records recorded by a physician,members of the patient’s family,and bystanders.This array of case records or case stories will enable us to narrate the interaction between physicians and patients both from the clinical perspective and from the social interaction.This paper will also discuss visual depictions of the medical encounter to provide another perspective for narrating medicine during the Song dynasty.Medical case records and paintings depicting medical encounters are exemplary of the potential of Chinese primary sources for narrative medicine.
文摘The authors used suspension cells of Populus euphratica to isolate protoplast in the present study. Protoplasts were successfully obtained after 4 hours incubation in enzyme solution containing 1 0% cellulase “onozuka” R\|10, 0\^01% pectolyase Y\|23,0\^15% macerozyme R\|10 and 0\^1% hemicellulase at 25℃. Outward and inward single channels in plasma membrane were observed using cell\|attached recording of patch\|clamp technique. In this study, single channel records showed that more than one species of channel were obtained. These attempts in protoplast isolation and ion channel recording offers the opportunity to characterize cellular mechanisms of salt tolerance in tree species.
文摘In this paper a fault location and recording system based on a computer network is presented. A brief description of the system structure and main features are given. Emphasis is placed on the accurate fault location method for extra high voltage and long distance transmission lines.
基金The National Natural Science Foundation of China(No. 61076118, 90307013, 90707005)the Natural Science Foundation of Jiangsu Province (No. BK2008032)Special Foundation and Open Foundation of the State Key Laboratory of Bioelectronics of Southeast University
文摘A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair consists of one stimulating electrode and one recording electrode. Supported by the peripheral circuits, four electrode states to study the bioelectrical signal of biological tissue or slice cultured in-vitro on the surface of the electrodes can be realized through each pair of electrodes. The four electrode states are stimulation, recording, stimulation and recording simultaneously, and isolation. The state of each pair of working electrodes can be arbitrarily controlled according to actual needs. The MEAs are fabricated in printed circuit board (PCB) technology. The total area of the PCB-based MEA is 49 mm × 49 mm. The impedance measurement of MEA is carried out in 0.9% sodium chloride solution at room temperature by means of 2-point measurements with an Agilent LCR meter, and the test signal for the impedance measurement is sinusoidal (AC voltage 50 mV, sweeping frequency 20 Hz to 10 kHz). The electrode impedance is between 200 and 3 kΩ while the frequency is between 500 and 1 000 Hz. The electrode impedance magnitude is inversely proportional to the frequency. Experiments of toad sciatic nerve in-vitro stimulation and recording and signal regeneration between isolated toad sciatic nerves are carried out on the PCB-based MEA. The results show that the MEA can be used for bioelectrical signal stimulation, recording, stimulation and recording simultaneously, and isolation of biological tissues or slices in-vitro.
文摘Objective To re-confirm and characterize the biophysical and pharmacological properties of endogenously expressed human acid-sensing ion channel 1a (hASIC1a) current in HEK293 cells with a modified perfusion methods. Methods With cell floating method, which is separating the cultured cell from coverslip and putting the cell in front of perfusion tubing, whole cell patch clamp technique was used to record hASICla currents evoked by low pH external solution. Results Using cell floating method, the amplitude of hASICla currents activated by pH 5.0 in HEK293 cells is twice as large as that by the conventional method where the cells remain attached to coverslip. The time to reach peak at two different recording conditions is (21±5) ms and (270±25) ms, respectively. Inactivation time constants are (496±23) ms and (2284±120) ms, respectively. The cell floating method significantly increases the amiloride potency of block on hASIC 1 a [IC50 is (3.4± 1.1 ) μmol/L and (2.4± 0.9) μmol/L, respectively]. Both recording methods have similar pH activation ECs0 (6.6±0.6, 6.6±0.7, respectively). Conclusion ASICs channel activation requires fast exchange of extracellular solution with the different pH values. With cell floating method, the presence of hASIC la current was re-confirmed and the biophysical and pharmacological properties of hASIC la channel in HEK293 cells was precisely characterized. This method could be used to study all ASICs and other ligand-gated channels that require fast extracellular solution exchange.
基金NSFC Under Grant No. 90715038MOST of China Under Grant No. 2006BAC13B02
文摘The National Strong Motion Observation Network System (NSMONS) of China is briefly introduced in this paper. The NSMONS consists of permanent free-field stations, special observation arrays, mobile observatories and a network management system. During the Wenchuan Earthquake, over 1,400 components of acceleration records were obtained from 460 permanent free-field stations and three arrays for topographical effect and structural response observation in the network system from the main shock, and over 20,000 components of acceleration records from strong aftershocks occurred before August 1, 2008 were also obtained by permanent free-field stations of the NSMONS and 59 mobile instruments quickly deployed after the main shock. The strong motion recordings from the main shock and strong aftershocks are summarized in this paper. In the ground motion recordings, there are over 560 components with peak ground acceleration (PGA) over 10 Gal, the largest being 957.7 Gal. The largest PGA recorded during the aftershock exceeds 300 Gal.
基金National Key Technology R&D Program Under Grant No.2009BAK55B05Nonprofit Industry Research Project of CEA Under Grant No.201108003Science Foundation of Institute of Engineering Mechanics,CEA Under Grant No.2010C01
文摘Local site conditions play an important role in the effective application of strong motion recordings.In the China National Strong Motion Observation Network System(NSMONS),some of the stations do not provide borehole information,and correspondingly,do not assign the site classes yet.In this paper,site classification methodologies for free-field strong motion stations are reviewed and the limitations and uncertainties of the horizontal-to-vertical spectral ratio(HVSR) methods are discussed.Then,a new method for site classification based on the entropy weight theory is proposed.The proposed method avoids the head or tail joggle phenomenon by providing the objective and subjective weights.The method was applied to aftershock recordings from the 2008 Wenchuan earthquake,and 54 free-field NSMONS stations were selected for site classification and the mean HVSRs were calculated.The results show that the improved HVSR method proposed in this paper has a higher success rate and could be adopted in NSMONS.
基金supported by the National Natural Science Foundation of China (No. 51101013)Specialized Research Fund for the Doctoral Program of Higher Education of China(No. 20090006120013)the Fundamental Research Funds for the Central Universities (FRF-TP-12-038A)
文摘The thickness of CoP thin films prepared by wet chemical deposition is of crucial importance on magnetic property and recording perform-ance. The coercivity of CoP films decreased with increasing film thickness. The coercivity was 45.37 kA m 1 at the thickness of 300 nm, and decreased to 21.65 kA m 1 at 5.7 μm. Recording performance tests indicate that, for drums with the same size, different recorded magnetic pole density have different thickness requirements. For 40 mm diameter magnetic drum, the optimal CoP thickness is 3~10 μm for 256 re-corded magnetic poles, 1~2 μm for 512 recorded magnetic poles, and 500~800 nm for 1024 recorded magnetic poles.
基金National Natural Science Foundation of China Under Grant No.40374017
文摘Current practice uses predictive models to extrapolate long-period response spectra based on far-field recordings in moderate and weak earthquakes. However, the spectra are not long enough and the data are often not reliable, which means that the seismic design code cannot accurately define seismic design requirements for long-period structures. The near-field recordings in the main-shock of the Chi-Chi earthquake have a large signal-to-noise ratio (SNR), which makes them suitable for studying the long-period acceleration response spectrum up to 20 sec. The acceleration response spectra from 246 stations within 120 km of the causative fault are statistically analyzed in this paper. The influence of distance and site conditions on long-period response spectrum is discussed, and the shapes of the amplification spectra are compared with the standard spectra specified in the seismic design code of China. Finally, suggestions for future revisions to the code are proposed.