Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidime...Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidimetric assay forβ2-MG as the research object,β2-MG levels were detected by different concentration gradients ofβ2-microglobulin samples in Liedemann,Mack,and Myriad reagents of three manufacturers on two automatic biochemical analyzers,and the difference of the hook effect was comparatively analyzed.Results:Leadman reagent showed the hook effect on the Beckman AU5800 automated biochemistry analyzer,while both Maccura and Mindray reagents did not show the hook effect.After the experiments,we found the limit value of the pre-zone check of Leadman reagent,and changed the parameters of the instrument,when the limit value of the pre-zone check was reached,the instrument automatically diluted the specimen five times and then detected it again.After changing the parameters of the instrument,the correlation between the three methods of detecting samples of different concentrations was r>0.99.Conclusion:Before selecting the application of immunoturbidimetric reagents,we have to carry out the risk assessment of the hook effect and selectively set the parameters of the pre-zone check based on the highest concentration that may occur in the clinic;for the items that may have the hook effect,we have to selectively set the parameters of the pre-zone check when the ratio of average reaction rate and the immediate reaction rate is at the limit value,and the phenomenon of antigen excess may occur,the instrument will carry out automatic dilution before detection,so as to avoid the issuance of erroneous results of high-value samples due to the hook effect.展开更多
AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients ...AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients with well-controlled Goldmann applanation tonometer(GAT) who routinely consulted Kitasato University Hospital Glaucoma Department between January 2010 and February 2014 were enrolled.GAT and ORA parameters including corneal compensated intraocular pressure(lOPcc),Goldmann estimated intraocular pressure(lOPg),corneal hysteresis(CH),corneal resistance factor(CRF) were recorded.VF was tested by Swedish interactive threshold algorithm(SITA)-standard 30-2 fields.All patients underwent VF measurement regularly and GAT did not exceed 15 mm Hg at any time during the 3y follow up.Patients were divided into four groups according to VF change over 3y,and ORA findings were compared between the upper 25th percentile group(slow progression group) and the lower 25th percentile group(rapid progression group).RESULTS:Eighty-two eyes of 56 patients were studied.There were 21 eyes(21 patients) each in rapid and slow progression groups respectively.GAT,lOPcc,lOPg,CH,CRF were 12.1+1.4 mm Hg,15.8±1.8 mm Hg,12.8±2.0 mm Hg,8.4±1.1 mm Hg,7.9±1.3 mm Hg respectively in rapid progression group and 11.5±1.3 mm Hg,13.5±2.1 mm Hg,11.2±1.6 mm Hg,9.3±1.1 mm Hg,8.2±0.9 mm Hg respectively in slow progression group(P=0.214,〈0.001,0.007,0.017,0.413,respectively).In bivariate correlation analysis,lOPcc,lOPcc-GAT and CH were significant correlated with m△MD(r =-0.292,-0.312,0.228 respectively,P =0.008,0.004,0.039 respectively).CONCLUSION:Relatively rapid VF progression occurred in NTG patients whose lOPcc are rather high,CH are rather low and the difference between lOPcc and GAT are relatively large.Higher lOPcc and lower CH are associated with VF progression in NTG patients.This study suggests that GAT measures might underestimate the IOP in such patients.展开更多
基金Baoding Science and Technology Bureau(2141ZF313)。
文摘Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidimetric assay forβ2-MG as the research object,β2-MG levels were detected by different concentration gradients ofβ2-microglobulin samples in Liedemann,Mack,and Myriad reagents of three manufacturers on two automatic biochemical analyzers,and the difference of the hook effect was comparatively analyzed.Results:Leadman reagent showed the hook effect on the Beckman AU5800 automated biochemistry analyzer,while both Maccura and Mindray reagents did not show the hook effect.After the experiments,we found the limit value of the pre-zone check of Leadman reagent,and changed the parameters of the instrument,when the limit value of the pre-zone check was reached,the instrument automatically diluted the specimen five times and then detected it again.After changing the parameters of the instrument,the correlation between the three methods of detecting samples of different concentrations was r>0.99.Conclusion:Before selecting the application of immunoturbidimetric reagents,we have to carry out the risk assessment of the hook effect and selectively set the parameters of the pre-zone check based on the highest concentration that may occur in the clinic;for the items that may have the hook effect,we have to selectively set the parameters of the pre-zone check when the ratio of average reaction rate and the immediate reaction rate is at the limit value,and the phenomenon of antigen excess may occur,the instrument will carry out automatic dilution before detection,so as to avoid the issuance of erroneous results of high-value samples due to the hook effect.
文摘AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients with well-controlled Goldmann applanation tonometer(GAT) who routinely consulted Kitasato University Hospital Glaucoma Department between January 2010 and February 2014 were enrolled.GAT and ORA parameters including corneal compensated intraocular pressure(lOPcc),Goldmann estimated intraocular pressure(lOPg),corneal hysteresis(CH),corneal resistance factor(CRF) were recorded.VF was tested by Swedish interactive threshold algorithm(SITA)-standard 30-2 fields.All patients underwent VF measurement regularly and GAT did not exceed 15 mm Hg at any time during the 3y follow up.Patients were divided into four groups according to VF change over 3y,and ORA findings were compared between the upper 25th percentile group(slow progression group) and the lower 25th percentile group(rapid progression group).RESULTS:Eighty-two eyes of 56 patients were studied.There were 21 eyes(21 patients) each in rapid and slow progression groups respectively.GAT,lOPcc,lOPg,CH,CRF were 12.1+1.4 mm Hg,15.8±1.8 mm Hg,12.8±2.0 mm Hg,8.4±1.1 mm Hg,7.9±1.3 mm Hg respectively in rapid progression group and 11.5±1.3 mm Hg,13.5±2.1 mm Hg,11.2±1.6 mm Hg,9.3±1.1 mm Hg,8.2±0.9 mm Hg respectively in slow progression group(P=0.214,〈0.001,0.007,0.017,0.413,respectively).In bivariate correlation analysis,lOPcc,lOPcc-GAT and CH were significant correlated with m△MD(r =-0.292,-0.312,0.228 respectively,P =0.008,0.004,0.039 respectively).CONCLUSION:Relatively rapid VF progression occurred in NTG patients whose lOPcc are rather high,CH are rather low and the difference between lOPcc and GAT are relatively large.Higher lOPcc and lower CH are associated with VF progression in NTG patients.This study suggests that GAT measures might underestimate the IOP in such patients.