Spinal cord injuries lead to significant loss of motor, sensory, and autonomic functions, presenting major challenges in neural regeneration. Achieving effective therapeutic concentrations at injury sites has been a s...Spinal cord injuries lead to significant loss of motor, sensory, and autonomic functions, presenting major challenges in neural regeneration. Achieving effective therapeutic concentrations at injury sites has been a slow process, partly due to the difficulty of delivering drugs effectively. Nanoparticles, with their targeted delivery capabilities, biocompatibility, and enhanced bioavailability over conventional drugs, are garnering attention for spinal cord injury treatment. This review explores the current mechanisms and shortcomings of existing treatments, highlighting the benefits and progress of nanoparticle-based approaches. We detail nanoparticle delivery methods for spinal cord injury, including local and intravenous injections, oral delivery, and biomaterial-assisted implantation, alongside strategies such as drug loading and surface modification. The discussion extends to how nanoparticles aid in reducing oxidative stress, dampening inflammation, fostering neural regeneration, and promoting angiogenesis. We summarize the use of various types of nanoparticles for treating spinal cord injuries, including metallic, polymeric, protein-based, inorganic non-metallic, and lipid nanoparticles. We also discuss the challenges faced, such as biosafety, effectiveness in humans, precise dosage control, standardization of production and characterization, immune responses, and targeted delivery in vivo. Additionally, we explore future directions, such as improving biosafety, standardizing manufacturing and characterization processes, and advancing human trials. Nanoparticles have shown considerable progress in targeted delivery and enhancing treatment efficacy for spinal cord injuries, presenting significant potential for clinical use and drug development.展开更多
Flexible,breathable,and highly sensitive pressure sensors have increasingly become a focal point of interest due to their pivotal role in healthcare monitoring,advanced electronic skin applications,and disease diagnos...Flexible,breathable,and highly sensitive pressure sensors have increasingly become a focal point of interest due to their pivotal role in healthcare monitoring,advanced electronic skin applications,and disease diagnosis.However,traditional methods,involving elastomer film-based substrates or encapsulation techniques,often fall short due to mechanical mismatches,discomfort,lack of breathability,and limitations in sensing abilities.Consequently,there is a pressing need,yet it remains a significant challenge to create pressure sensors that are not only highly breathable,flexible,and comfortable but also sensitive,durable,and biocompatible.Herein,we present a biocompatible and breathable fabric-based pressure sensor,using nonwoven fabrics as both the sensing electrode(coated with MXene/poly(3,4-ethylenedioxythiophene):polystyrene sulfonate[PEDOT:PSS])and the interdigitated electrode(printed with MXene pattern)via a scalable spray-coating and screen-coating technique.The resultant device exhibits commendable air permeability,biocompatibility,and pressure sensing performance,including a remarkable sensitivity(754.5 kPa^(−1)),rapid response/recovery time(180/110 ms),and robust cycling stability.Furthermore,the integration of PEDOT:PSS plays a crucial role in protecting the MXene nanosheets from oxidation,significantly enhancing the device's long-term durability.These outstanding features make this sensor highly suitable for applications in fullrange human activities detection and disease diagnosis.Our study underscores the promising future of flexible pressure sensors in the realm of intelligent wearable electronics,setting a new benchmark for the industry.展开更多
Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,part...Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,particularly those made from conventional steel or titanium alloys.In this study,a biodegradable Zn-0.45Mn-0.2Mg(ZMM42)alloy with the yield strength of 300.4 MPa and tensile strength of 329.8 MPa was prepared through hot extrusion.The use of zinc alloys in the preparation of cortical suspension fixation buttons was proposed for the first time.After 35 d of immersion in simulated body fluids,the ZMM42 alloy fixation buttons were degraded at a rate of 44μm/a,and the fixation strength was retained(379.55 N)in the traction loops.Simultaneously,the ZMM42 alloy fixation buttons exhibited an increase in MC3T3-E1 cell viability and high antibacterial activity against Escherichia coli and Staphylococcus aureus.These results reveal the potential of biodegradable zinc alloys for use as ligament reconstruction materials and for developing diverse zinc alloy cortical suspension fixation devices.展开更多
Developing high-performance aqueous Zn-ion batteries from sustainable biomass becomes increasingly vital for large-scale energy storage in the foreseeable future.Therefore,γ-MnO_(2) uniformly loaded on N-doped carbon...Developing high-performance aqueous Zn-ion batteries from sustainable biomass becomes increasingly vital for large-scale energy storage in the foreseeable future.Therefore,γ-MnO_(2) uniformly loaded on N-doped carbon derived from grapefruit peel is successfully fabricated in this work,and particularly the composite cathode with carbon carrier quality percentage of 20 wt%delivers the specific capacity of 391.2 mAh g^(−1)at 0.1 A g^(−1),outstanding cyclic stability of 92.17%after 3000 cycles at 5 A g^(−1),and remarkable energy density of 553.12 Wh kg^(−1) together with superior coulombic efficiency of~100%.Additionally,the cathodic biosafety is further explored specifically through in vitro cell toxicity experiments,which verifies its tremendous potential in the application of clinical medicine.Besides,Zinc ion energy storage mechanism of the cathode is mainly discussed from the aspects of Jahn–Teller effect and Mn domains distribution combined with theoretical analysis and experimental data.Thus,a novel perspective of the conversion from biomass waste to biocompatible Mn-based cathode is successfully developed.展开更多
Achieving flexible electronics with comfort and durability comparable to traditional textiles is one of the ultimate pursuits of smart wearables.Ink printing is desirable for e-textile development using a simple and i...Achieving flexible electronics with comfort and durability comparable to traditional textiles is one of the ultimate pursuits of smart wearables.Ink printing is desirable for e-textile development using a simple and inexpensive process.However,fabricating high-performance atop textiles with good dispersity,stability,biocompatibility,and wearability for high-resolution,large-scale manufacturing,and practical applications has remained challenging.Here,waterbased multi-walled carbon nanotubes(MWCNTs)-decorated liquid metal(LM)inks are proposed with carbonaceous gallium–indium micro-nanostructure.With the assistance of biopolymers,the sodium alginate-encapsulated LM droplets contain high carboxyl groups which non-covalently crosslink with silk sericin-mediated MWCNTs.E-textile can be prepared subsequently via printing technique and natural waterproof triboelectric coating,enabling good flexibility,hydrophilicity,breathability,wearability,biocompatibility,conductivity,stability,and excellent versatility,without any artificial chemicals.The obtained e-textile can be used in various applications with designable patterns and circuits.Multi-sensing applications of recognizing complex human motions,breathing,phonation,and pressure distribution are demonstrated with repeatable and reliable signals.Self-powered and energy-harvesting capabilities are also presented by driving electronic devices and lighting LEDs.As proof of concept,this work provides new opportunities in a scalable and sustainable way to develop novel wearable electronics and smart clothing for future commercial applications.展开更多
Constructing a functional hybrid coating appears to be a promising strategy for addressing the poor corrosion resistance and insufficient endothelialization of Mg-based stents.Nevertheless,the steps for preparing comp...Constructing a functional hybrid coating appears to be a promising strategy for addressing the poor corrosion resistance and insufficient endothelialization of Mg-based stents.Nevertheless,the steps for preparing composite coatings are usually complicated and time-consuming.Herein,a novel composite coating,composed of bioactive magnesium thioctic acid(MTA)layer formed by deposition and corrosion-resistant magnesium hydroxide(Mg(OH)_(2))layer grown in situ,is simply fabricated on ZE21B alloys via one-step electrodeposition.Scanning electron microscopy(SEM)shows that the electrodeposited coating has a compact and uniform structure.And the high adhesion of the MTA/Mg(OH)_(2)hybrid coating is also confirmed by the micro-scratch test.Electrochemical test,scanning kelvin probe(SKP),and hydrogen evolution measurement indicate that the hybrid coating effectively reduces the degradation rate of Mg substrates.Haemocompatibility experiment and cell culture trial detect that the composite coating is of fine biocompatibility.Finally,the preparation mechanism of MTA/Mg(OH)_(2)hybrid coatings is discussed and proposed.This coating shows a great potential application for cardiovascular stents.展开更多
Magnesium(Mg)and its alloys have recently gained increasing attention in the biomedical field as promising biodegradable materials with harmless degradation products.Magnesium-based alloys have a wide range of biomedi...Magnesium(Mg)and its alloys have recently gained increasing attention in the biomedical field as promising biodegradable materials with harmless degradation products.Magnesium-based alloys have a wide range of biomedical applications because of their outstanding biocompatibility and unique mechanical properties.Widespread use of Mg-based biomedical devices eliminates the need for post-healing biomaterial removal surgery and minimizes the negative consequences of the implantation of permanent biomaterials,including stress shielding and undesired metal ion release in the body.This paper provides a literature review on the properties and manufacturing methods of Mgbased alloys for biomedical applications,including orthopedic implants,cardiovascular applications,surgical wires and staplers,and antitumor activities.Each application of Mg-based biomaterials is investigated from a biological perspective,including matching functional properties,biocompatibility,host tissue responses,and anti-microbial strategies,along with potential additive manufacturing technologies for these applications.Finally,an outlook is presented to provide recommendations for Mg-based biomaterials in the future.展开更多
The as-cast Mg-2.0Zn-1.5Sn-xZr(x=0,0.4,0.6,0.8,1.0 wt%)alloy was rolled with the pressure less than 5%each time.The microstructure,mechanical properties,corrosion properties and biocompatibility of the alloy were inve...The as-cast Mg-2.0Zn-1.5Sn-xZr(x=0,0.4,0.6,0.8,1.0 wt%)alloy was rolled with the pressure less than 5%each time.The microstructure,mechanical properties,corrosion properties and biocompatibility of the alloy were investigated.The microstructure of the alloy was observed and analyzed by scanning electron microscope,and the tensile test was carried out by universal tensile machine.The corrosion resistance of the alloy in Hank's solution was studied by hydrogen evolution experiment and electrochemical test,and the biocompatibility of the alloy was tested by L929 cells.The results show that Mg-2Zn-1.5Sn-xZr alloy has excellent mechanical properties.The elongation of Mg-2Zn-1.5Sn-xZr alloy decreases with the increase of Zr content,but the tensile strength first increases and then decreases with the increase of Zr concentration.When the Zr content is 0.8 wt%,the maximum tensile strength of the alloy is 235 MPa.The results of hydrogen evolution experiment and electrochemical analysis show that the corrosion resistance of the alloy is the best when the Zr content is 0.8 wt%,and all the five alloys have high biocompatibility.In conclusion,the rolled alloy has good properties and has broad application prospects in the field of biomaterials.展开更多
Magnesium(Mg)alloys are gaining great consideration as body implant materials due to their high biodegradability and biocompatibility.However,they suffer from low corrosion resistance and antibacterial activity.In thi...Magnesium(Mg)alloys are gaining great consideration as body implant materials due to their high biodegradability and biocompatibility.However,they suffer from low corrosion resistance and antibacterial activity.In this research,semi-powder metallurgy followed by hot extrusion was utilized to produce the magnesium oxide@graphene nanosheets/magnesium(MgO@GNS/Mg)composite to improve mechanical,corrosion and cytocompatibility characteristics.Investigations have revealed that the incorporation of MgO@GNS nanohybrids into Mg-based composite enhanced microhardness and compressive strength.In vitro,osteoblast cell culture tests show that using MgO@GNS nanohybrid fillers enhances osteoblast adhesion and apatite mineralization.The presence of MgO@GNS nanoparticles in the composites decreased the opening defects,micro-cracks and micro-pores of the composites thus preventing the penetration of the corrosive solution into the matrix.Studies demonstrated that the MgO@GNS/Mg composite possesses excellent antibacterial properties because of the combination of the release of MgO and physical damage to bacterium membranes caused by the sharp edges of graphene nanosheets that can effectively damage the cell wall thereby facilitating penetration into the bacterial lipid bilayer.Therefore,the MgO@GNS/Mg composite with high mechanical strength,antibacterial activity and corrosion resistance is considered to be a promising material for load-bearing implant applications.展开更多
In this study,a calcium-phosphate coating was formed on a Mg-Mn-Ce alloy by the plasma electrolytic oxidation(PEO).The antibiotic vancomycin,widely used in the treatment of infections caused by Staphylococcus aureus(S...In this study,a calcium-phosphate coating was formed on a Mg-Mn-Ce alloy by the plasma electrolytic oxidation(PEO).The antibiotic vancomycin,widely used in the treatment of infections caused by Staphylococcus aureus(S.aureus),was impregnated into the coating.Samples with vancomycin showed high bactericidal activity against S.aureus.The mechanical and electrochemical properties of the formed coatings were studied,as well as in vitro cytotoxicity tests and in vivo tests on mature male rats were performed.According to SEM,EDS,XRD and XPS data,coatings had a developed morphology and contained hydroxyapatite,which indicates high biocompatibility.The analysis of roughness of coatings without and with vancomycin did not reveal any differences,confirming the high roughness of the samples.During electrochemical tests,an increase in corrosion resistance by more than two times after the application of PEO coatings was revealed.According to the results of an in vivo study,after 28 days of the implantation of samples with calcium phosphate PEO coating and vancomycin,no signs of inflammation were observed,while an inflammatory reaction developed in the area of implantation of bare alloy,followed by encapsulation.Antibiotic release tests from the coatings show a sharp decrease in the concentration of the released antibiotic on day 7 and then a gradual decrease until day 28.Throughout the experiment,no significant deviations in the condition and behavior of the animals were observed;clinical tests did not reveal a systemic toxic reaction.展开更多
Biodegradable implants from magnesium(Mg)alloys have emerged in the biomedical field especially in the orthopedic and cardiovascular stent applications owing to their low density,high specific strength,excellent machi...Biodegradable implants from magnesium(Mg)alloys have emerged in the biomedical field especially in the orthopedic and cardiovascular stent applications owing to their low density,high specific strength,excellent machinability,good biocompatibility,and biodegradability.The primary shortcoming of Mg-based implants is their low corrosion resistance in the physiological environment,which results in premature mechanical integrity loss before adequate healing and the production of excessive hydrogen gas,which is harmful to the body tissues and negatively affects the biocompatibility of the implant.Laser surface modification has recently received attention because it can improve the surface properties such as surface chemistry,roughness,topography,corrosion resistance,wear resistance,hydrophilicity,and thus cell response to the surface of the material.The composition and microstructures including textures and phases of laser-treated surfaces depend largely on the laser processing parameters(input laser power,laser scan velocity,frequency,pulse duration,pressure,gas circulation,working time,spot size,beam focal position,and laser track overlap)and the thermophysical properties of the substrate(solubility,melting point,and boiling point).This review investigates the impacts of various laser surface modification techniques including laser surface melting,laser surface alloying,laser cladding,laser surface texturing,and laser shock peening,and highlights their significance in improving the surface properties of biodegradable Mg alloys for implant applications.Additionally,we explore how different laser process parameters affect its composition,microstructure,and surface properties in each laser surface modification technique.展开更多
Corrosion-resistant and biocompatible films were fabricated on AZ91D Mg alloy substrates by varying their roughness levels using met-allographic preparation and subsequent hydrothermal procedures.The coated films comp...Corrosion-resistant and biocompatible films were fabricated on AZ91D Mg alloy substrates by varying their roughness levels using met-allographic preparation and subsequent hydrothermal procedures.The coated films comprised a mixed structure of Mg(OH)_(2)and Mg-Al layered double hydroxides(LDH)and exhibited excellent compactness.Coating film thickness increased with decreasing surface roughness.Corrosion resistance was evaluated using potentiodynamic polarization and electrochemical impedance spectroscopy.Metallographic pretreat-ment influenced the chemical activity of the Mg alloy surface and helped modulate the dissolution rate of the Mg_(17)Al_(12)phase during the hydrothermal procedure.With decreasing roughness of the Mg substrate,the Al^(3+)concentration gradually increased,accelerating the in-situ formation of the Mg(OH)_(2)/LDH composite coating and improving its crystallinity.A thick and dense Mg(OH)_(2)/LDH coating was synthesized on the Mg substrate with the least roughness,substantially improving the corrosion resistance of the AZ91D alloy.The lowest corrosion current density((5.73±2.75)×10^(−8)A·cm^(−2))was achieved,which was approximately three orders of magnitude less than that of bare AZ91D.Moreover,the coating demonstrated biocompatibility with no evident cytotoxicity,cellular damage,and hemolytic phenomena.This study provides an effective method for preparing coatings on Mg alloy surfaces with excellent corrosion resistance and biocompatibility.展开更多
Zinc-based composites represent promising materials for orthopedic implants owing to their adjustable degradation rates and excellent biocompatibility.In this study,a series of Zn-10Mg-xHA(x=0-5 wt.%)composites with t...Zinc-based composites represent promising materials for orthopedic implants owing to their adjustable degradation rates and excellent biocompatibility.In this study,a series of Zn-10Mg-xHA(x=0-5 wt.%)composites with the core-shell structure were prepared through spark plasma sintering,and their microstructural,mechanical,and in vitro properties were systematically evaluated.Results showed that the doped hydroxyapatite(HA)is concentrated at the outer edge of the MgZn2 shell layer.The compression strength of the Zn-1oMg HA composite gradually decreased with the increase of the HA content,while its corrosion rate decreased initially and then increased.The corrosion resistance of the composite with the addition of 1 wt.%HA was improved compared to that of Zn-10Mg-0HA.However,the further increase of the HA content beyond 1 wt.%resulted in a faster degradation of the composite.Moreover,the Zn-10Mg-1HA composite significantly enhanced the activity of Mc3T3-E1 osteoblasts.Based on such findings,it is revealed that the composite containing 1 wt.%HA exhibits superior overall properties and is anticipated to serve as a promising candidate for bone implantmaterials.展开更多
The repair and regeneration of bone defects are highly challenging orthopedic problems.Recently,Mg-based implants have gained popularity due to their unique biodegradation and elastic modulus similar to that of human ...The repair and regeneration of bone defects are highly challenging orthopedic problems.Recently,Mg-based implants have gained popularity due to their unique biodegradation and elastic modulus similar to that of human bone.The aim of our study is to develop a magnesium alloy with a controllable degradation that can closely match bone tissue to help injuries heal in vivo and avoid cytotoxicity caused by a sudden increase in ion concentration.In this study,we prepared and modified Mg-3Zn,Mg-3Zn-1Y,and Mg-2Zn-1Mn by hot extrusion,and used Mg-2.5Y-2.5Nd was as a control.We then investigated the effect of additions of Y and Mn on alloys'properties.Our results show that Mn and Y can improve not only compression strength but also corrosion resistance.The alloy Mg-2Zn-1Mn demonstrated good cytocompatibility in vitro,and for this reason we selected it for implantation in vivo.The degraded Mg-2Zn-1Mn implanted a bone defect area did not cause obvious rejection and inflammatory reaction,and the degradation products left no signs of damage to the heart,liver,kidney,or brain.Furthermore,we find that Mg-2Zn-1Mn can promote an osteoinductive response in vivo and the formation of bone regeneration.展开更多
The Ti−45Nb(wt.%)alloy properties were investigated in relation to its potential biomedical use.Laser surface modification was utilized to improve its performance in biological systems.As a result of the laser treatme...The Ti−45Nb(wt.%)alloy properties were investigated in relation to its potential biomedical use.Laser surface modification was utilized to improve its performance in biological systems.As a result of the laser treatment,(Ti,Nb)O scale was formed and various morphological features appeared on the alloy surface.The electrochemical behavior of Ti−45Nb alloy in simulated body conditions was evaluated and showed that the alloy was highly resistant to corrosion deterioration regardless of additional laser surface modification treatment.Nevertheless,the improved corrosion resistance after laser treatment was evident(the corrosion current density of the alloy before laser irradiation was 2.84×10^(−8)A/cm^(2),while that after laser treatment with 5 mJ was 0.65×10^(−8)A/cm^(2))and ascribed to the rapid formation of a complex and passivating bi-modal surface oxide layer.Alloy cytotoxicity and effects of the Ti−45Nb alloy laser surface modification on the MRC-5 cell viability,morphology,and proliferation were also investigated.The Ti−45Nb alloy showed no cytotoxic effect.Moreover,cells showed improved viability and adherence to the alloy surface after the laser irradiation treatment.The highest average cell viability of 115.37%was attained for the alloy laser-irradiated with 15 mJ.Results showed that the laser surface modification can be successfully utilized to significantly improve alloy performance in a biological environment.展开更多
Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation.However,localized corrosion and H_(2)generation limit the potential of Mg...Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation.However,localized corrosion and H_(2)generation limit the potential of Mg-based implants.Utilizing low-alloyed Mg-Zn wires can strongly reduce problems with large H_(2)bubbles and improve the mechanical properties considerably while maintaining excellent long-term biocompatibility.Acidic pickling and a polymer coating can be effectively used to lower the rate of in vivo degradation.In this work,microstructural,mechanical,and in vitro characterization of 250μm and 300μm extruded wires made from ultra-pure Mg,commercially pure Mg,Mg-0.15Zn,Mg-0.4Zn and Mg-1Zn was performed.Additionally,Mg-0.4Zn wires together with a variant coated with a copolymer of L-lactide andε-caprolactone were tested in vivo on artificially damaged Wistar rat femurs.Based on the observed Mg-induced osteogenesis,polymer-coated Mg wires with a small addition of Zn are a perspective material for bone-support applications,such as cerclage and fixation wires.展开更多
AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular le...AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis.展开更多
The study focuses on the development of biocompatible and stable FA-functionalized nanocrystalline cellulose(NCC)as a potential drug delivery system for targeting folate receptor-positive cancer cells.The FA-functiona...The study focuses on the development of biocompatible and stable FA-functionalized nanocrystalline cellulose(NCC)as a potential drug delivery system for targeting folate receptor-positive cancer cells.The FA-functionalized NCCs were synthesized through a series of chemical reactions,resulting in nanoparticles with favorable properties for biomedical applications.The microstructural analysis revealed that the functionalized NCCs maintained their rod-shaped morphology and displayed hydrodynamic diameters suitable for evading the mononuclear phagocytic system while being large enough to target tumor tissues.Importantly,these nanoparticles possessed a negative surface charge,enhancing their stability and repelling potential aggregation.The binding specificity of FA-functionalized NCCs to folate receptor-positive cancer cells was demonstrated through various assays.The free folic acid inhibition assay showed approximately 30%decrease in the binding of functionalized NCCs in the presence of just 5 mM free FA,confirming their selectivity for folate receptor-positive cells.Confocal microscopy further validated this specificity,as only cancer cells displayed significant binding of functionalized NCCs.Crucially,biocompatibility tests revealed that both NCCs and FA-functionalized NCCs had minimal effects on red blood cells,and they did not induce erythrocyte aggregation.Furthermore,cell viability assays demonstrated functionalized NCCs have selective cytotoxicity against colorectal cancer cells HT-29 and SW-620(68%–88%cell viability)while sparing noncancerous colon cells CCD-18Co(81%–97%cell viability).In summary,FA-functionalized NCCs exhibit promising characteristics for targeted drug delivery in cancer therapy.Their biocompatibility,stability,and selective cytotoxicity make them an attractive option for delivering therapeutic agents to folate receptor-positive cancer cells,potentially improving the effectiveness of cancer treatments while minimizing harm to healthy tissues.展开更多
Bone regeneration is a critical area in regenerative medicine,particularly in orthopedics,demanding effective biomedical materials for treating bone defects.45S5 bioactive glass(45S5 BG)is a promising material because...Bone regeneration is a critical area in regenerative medicine,particularly in orthopedics,demanding effective biomedical materials for treating bone defects.45S5 bioactive glass(45S5 BG)is a promising material because of its osteoconductive and bioactive properties.As research in this field continues to advance,keeping up-to-date on the latest and most successful applications of this material is imperative.To achieve this,we conducted a comprehensive search on Pub-Med/MEDLINE,focusing on English articles published in the last decade.Our search used the keywords“bioglass 45S5 AND bone defect”in combination.We found 27 articles,and after applying the inclusion criteria,we selected 15 studies for detailed examination.Most of these studies compared 45S5 BG with other cement or scaffold materials.These comparisons demonstrate that the addition of various composites enhances cellular biocompatibility,as evidenced by the cells and their osteogenic potential.Moreover,the use of 45S5 BG is enhanced by its antimicrobial properties,opening avenues for additional investigations and applications of this biomaterial.展开更多
Biodegradable magnesium alloys have been widely used in medical implants. But safety concerns were put forward for the high degradation rate of biodegradable magnesium alloy. The optimal biodegradable magnesium alloys...Biodegradable magnesium alloys have been widely used in medical implants. But safety concerns were put forward for the high degradation rate of biodegradable magnesium alloy. The optimal biodegradable magnesium alloys that give rise to the desired degradation rate hasn’t yet to be defined. Assessing the degradation rate of biodegradable magnesium alloys involves in vitro testing, in vivo testing, numerical modeling, understanding the factors influencing their degradation in physiological environments, biocompatibility testing, and clinical studies. It is important to standardize analytical tools aimed at assessing the degradation rate of biodegradable magnesium alloys. It is advisable to identify the threshold for safe degradation rate of biodegradable magnesium alloys in biomedical applications.展开更多
基金supported by the Key Research Projects of Universities of Henan Province,No.21A320064 (to XS)the National Key Research and Development Program of China,No.2021YFA1201504 (to LZ)+1 种基金the Strategic Priority Research Program of the Chinese Academy of Science,No.XDB36000000 (to CW)the National Natural Science Foundation of China,Nos.31971295,12374406 (both to LZ)。
文摘Spinal cord injuries lead to significant loss of motor, sensory, and autonomic functions, presenting major challenges in neural regeneration. Achieving effective therapeutic concentrations at injury sites has been a slow process, partly due to the difficulty of delivering drugs effectively. Nanoparticles, with their targeted delivery capabilities, biocompatibility, and enhanced bioavailability over conventional drugs, are garnering attention for spinal cord injury treatment. This review explores the current mechanisms and shortcomings of existing treatments, highlighting the benefits and progress of nanoparticle-based approaches. We detail nanoparticle delivery methods for spinal cord injury, including local and intravenous injections, oral delivery, and biomaterial-assisted implantation, alongside strategies such as drug loading and surface modification. The discussion extends to how nanoparticles aid in reducing oxidative stress, dampening inflammation, fostering neural regeneration, and promoting angiogenesis. We summarize the use of various types of nanoparticles for treating spinal cord injuries, including metallic, polymeric, protein-based, inorganic non-metallic, and lipid nanoparticles. We also discuss the challenges faced, such as biosafety, effectiveness in humans, precise dosage control, standardization of production and characterization, immune responses, and targeted delivery in vivo. Additionally, we explore future directions, such as improving biosafety, standardizing manufacturing and characterization processes, and advancing human trials. Nanoparticles have shown considerable progress in targeted delivery and enhancing treatment efficacy for spinal cord injuries, presenting significant potential for clinical use and drug development.
基金supported by the National Natural Science Foundation of China(52303051,52202108,52003002)Anhui Provincial Natural Science Foundation(2308085ME146,2008085QE213)+3 种基金Educational Commission of Anhui Province of China(2022AH040137)Key Laboratory of Intelligent Textile and Flexible Interconnection of Zhejiang Province(ZD04)Opening Fund of China National Textile and Apparel Council Key Laboratory of Flexible Devices for Intelligent Textile and Apparel,Soochow University(SDHY2227)research funding from Anhui Polytechnic University(2020YQQ002,Xjky2022070,FFBK202218,FFBK202363,FFBK202364,2020ffky01).
文摘Flexible,breathable,and highly sensitive pressure sensors have increasingly become a focal point of interest due to their pivotal role in healthcare monitoring,advanced electronic skin applications,and disease diagnosis.However,traditional methods,involving elastomer film-based substrates or encapsulation techniques,often fall short due to mechanical mismatches,discomfort,lack of breathability,and limitations in sensing abilities.Consequently,there is a pressing need,yet it remains a significant challenge to create pressure sensors that are not only highly breathable,flexible,and comfortable but also sensitive,durable,and biocompatible.Herein,we present a biocompatible and breathable fabric-based pressure sensor,using nonwoven fabrics as both the sensing electrode(coated with MXene/poly(3,4-ethylenedioxythiophene):polystyrene sulfonate[PEDOT:PSS])and the interdigitated electrode(printed with MXene pattern)via a scalable spray-coating and screen-coating technique.The resultant device exhibits commendable air permeability,biocompatibility,and pressure sensing performance,including a remarkable sensitivity(754.5 kPa^(−1)),rapid response/recovery time(180/110 ms),and robust cycling stability.Furthermore,the integration of PEDOT:PSS plays a crucial role in protecting the MXene nanosheets from oxidation,significantly enhancing the device's long-term durability.These outstanding features make this sensor highly suitable for applications in fullrange human activities detection and disease diagnosis.Our study underscores the promising future of flexible pressure sensors in the realm of intelligent wearable electronics,setting a new benchmark for the industry.
基金financially supported by the Xiongan New Area Science and Technology Innovation Project,China(No.2022XACX0600)the Beijing Nova Program Cross Cooperation Program,China(No.20220484178)。
文摘Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,particularly those made from conventional steel or titanium alloys.In this study,a biodegradable Zn-0.45Mn-0.2Mg(ZMM42)alloy with the yield strength of 300.4 MPa and tensile strength of 329.8 MPa was prepared through hot extrusion.The use of zinc alloys in the preparation of cortical suspension fixation buttons was proposed for the first time.After 35 d of immersion in simulated body fluids,the ZMM42 alloy fixation buttons were degraded at a rate of 44μm/a,and the fixation strength was retained(379.55 N)in the traction loops.Simultaneously,the ZMM42 alloy fixation buttons exhibited an increase in MC3T3-E1 cell viability and high antibacterial activity against Escherichia coli and Staphylococcus aureus.These results reveal the potential of biodegradable zinc alloys for use as ligament reconstruction materials and for developing diverse zinc alloy cortical suspension fixation devices.
基金supported by the National Natural Science Foundation of China[Grant no.51821004].
文摘Developing high-performance aqueous Zn-ion batteries from sustainable biomass becomes increasingly vital for large-scale energy storage in the foreseeable future.Therefore,γ-MnO_(2) uniformly loaded on N-doped carbon derived from grapefruit peel is successfully fabricated in this work,and particularly the composite cathode with carbon carrier quality percentage of 20 wt%delivers the specific capacity of 391.2 mAh g^(−1)at 0.1 A g^(−1),outstanding cyclic stability of 92.17%after 3000 cycles at 5 A g^(−1),and remarkable energy density of 553.12 Wh kg^(−1) together with superior coulombic efficiency of~100%.Additionally,the cathodic biosafety is further explored specifically through in vitro cell toxicity experiments,which verifies its tremendous potential in the application of clinical medicine.Besides,Zinc ion energy storage mechanism of the cathode is mainly discussed from the aspects of Jahn–Teller effect and Mn domains distribution combined with theoretical analysis and experimental data.Thus,a novel perspective of the conversion from biomass waste to biocompatible Mn-based cathode is successfully developed.
基金funded by The Hong Kong Polytechnic University(Project No.1-WZ1Y,1-YXAK,1-W21C).
文摘Achieving flexible electronics with comfort and durability comparable to traditional textiles is one of the ultimate pursuits of smart wearables.Ink printing is desirable for e-textile development using a simple and inexpensive process.However,fabricating high-performance atop textiles with good dispersity,stability,biocompatibility,and wearability for high-resolution,large-scale manufacturing,and practical applications has remained challenging.Here,waterbased multi-walled carbon nanotubes(MWCNTs)-decorated liquid metal(LM)inks are proposed with carbonaceous gallium–indium micro-nanostructure.With the assistance of biopolymers,the sodium alginate-encapsulated LM droplets contain high carboxyl groups which non-covalently crosslink with silk sericin-mediated MWCNTs.E-textile can be prepared subsequently via printing technique and natural waterproof triboelectric coating,enabling good flexibility,hydrophilicity,breathability,wearability,biocompatibility,conductivity,stability,and excellent versatility,without any artificial chemicals.The obtained e-textile can be used in various applications with designable patterns and circuits.Multi-sensing applications of recognizing complex human motions,breathing,phonation,and pressure distribution are demonstrated with repeatable and reliable signals.Self-powered and energy-harvesting capabilities are also presented by driving electronic devices and lighting LEDs.As proof of concept,this work provides new opportunities in a scalable and sustainable way to develop novel wearable electronics and smart clothing for future commercial applications.
基金the National Key Research and Development Program of China(2018YFC1106703)the National Natural Science Foundation of China(No.U1804251)。
文摘Constructing a functional hybrid coating appears to be a promising strategy for addressing the poor corrosion resistance and insufficient endothelialization of Mg-based stents.Nevertheless,the steps for preparing composite coatings are usually complicated and time-consuming.Herein,a novel composite coating,composed of bioactive magnesium thioctic acid(MTA)layer formed by deposition and corrosion-resistant magnesium hydroxide(Mg(OH)_(2))layer grown in situ,is simply fabricated on ZE21B alloys via one-step electrodeposition.Scanning electron microscopy(SEM)shows that the electrodeposited coating has a compact and uniform structure.And the high adhesion of the MTA/Mg(OH)_(2)hybrid coating is also confirmed by the micro-scratch test.Electrochemical test,scanning kelvin probe(SKP),and hydrogen evolution measurement indicate that the hybrid coating effectively reduces the degradation rate of Mg substrates.Haemocompatibility experiment and cell culture trial detect that the composite coating is of fine biocompatibility.Finally,the preparation mechanism of MTA/Mg(OH)_(2)hybrid coatings is discussed and proposed.This coating shows a great potential application for cardiovascular stents.
基金supported by National Research Foundation of Korea(NRF)grants funded by the Korean Government(MSIT)[grant numbers RS-2023-00207763 and NRF-2022R1A2C2010350].
文摘Magnesium(Mg)and its alloys have recently gained increasing attention in the biomedical field as promising biodegradable materials with harmless degradation products.Magnesium-based alloys have a wide range of biomedical applications because of their outstanding biocompatibility and unique mechanical properties.Widespread use of Mg-based biomedical devices eliminates the need for post-healing biomaterial removal surgery and minimizes the negative consequences of the implantation of permanent biomaterials,including stress shielding and undesired metal ion release in the body.This paper provides a literature review on the properties and manufacturing methods of Mgbased alloys for biomedical applications,including orthopedic implants,cardiovascular applications,surgical wires and staplers,and antitumor activities.Each application of Mg-based biomaterials is investigated from a biological perspective,including matching functional properties,biocompatibility,host tissue responses,and anti-microbial strategies,along with potential additive manufacturing technologies for these applications.Finally,an outlook is presented to provide recommendations for Mg-based biomaterials in the future.
基金Funded by National Natural Science Foundation of China(Nos.52161024,51761021)Ten Thousand Talents Program of Yunnan Province(No.YNWR-QNJ-2018-044)。
文摘The as-cast Mg-2.0Zn-1.5Sn-xZr(x=0,0.4,0.6,0.8,1.0 wt%)alloy was rolled with the pressure less than 5%each time.The microstructure,mechanical properties,corrosion properties and biocompatibility of the alloy were investigated.The microstructure of the alloy was observed and analyzed by scanning electron microscope,and the tensile test was carried out by universal tensile machine.The corrosion resistance of the alloy in Hank's solution was studied by hydrogen evolution experiment and electrochemical test,and the biocompatibility of the alloy was tested by L929 cells.The results show that Mg-2Zn-1.5Sn-xZr alloy has excellent mechanical properties.The elongation of Mg-2Zn-1.5Sn-xZr alloy decreases with the increase of Zr content,but the tensile strength first increases and then decreases with the increase of Zr concentration.When the Zr content is 0.8 wt%,the maximum tensile strength of the alloy is 235 MPa.The results of hydrogen evolution experiment and electrochemical analysis show that the corrosion resistance of the alloy is the best when the Zr content is 0.8 wt%,and all the five alloys have high biocompatibility.In conclusion,the rolled alloy has good properties and has broad application prospects in the field of biomaterials.
文摘Magnesium(Mg)alloys are gaining great consideration as body implant materials due to their high biodegradability and biocompatibility.However,they suffer from low corrosion resistance and antibacterial activity.In this research,semi-powder metallurgy followed by hot extrusion was utilized to produce the magnesium oxide@graphene nanosheets/magnesium(MgO@GNS/Mg)composite to improve mechanical,corrosion and cytocompatibility characteristics.Investigations have revealed that the incorporation of MgO@GNS nanohybrids into Mg-based composite enhanced microhardness and compressive strength.In vitro,osteoblast cell culture tests show that using MgO@GNS nanohybrid fillers enhances osteoblast adhesion and apatite mineralization.The presence of MgO@GNS nanoparticles in the composites decreased the opening defects,micro-cracks and micro-pores of the composites thus preventing the penetration of the corrosive solution into the matrix.Studies demonstrated that the MgO@GNS/Mg composite possesses excellent antibacterial properties because of the combination of the release of MgO and physical damage to bacterium membranes caused by the sharp edges of graphene nanosheets that can effectively damage the cell wall thereby facilitating penetration into the bacterial lipid bilayer.Therefore,the MgO@GNS/Mg composite with high mechanical strength,antibacterial activity and corrosion resistance is considered to be a promising material for load-bearing implant applications.
基金supported by Russian Science Foundation Grant no.22-73-10149,https://rscf.ru/project/22-73-10149/supported by the Russian Science Foundation Grant no.23-13-00329,https://rscf.ru/project/23-13-00329/。
文摘In this study,a calcium-phosphate coating was formed on a Mg-Mn-Ce alloy by the plasma electrolytic oxidation(PEO).The antibiotic vancomycin,widely used in the treatment of infections caused by Staphylococcus aureus(S.aureus),was impregnated into the coating.Samples with vancomycin showed high bactericidal activity against S.aureus.The mechanical and electrochemical properties of the formed coatings were studied,as well as in vitro cytotoxicity tests and in vivo tests on mature male rats were performed.According to SEM,EDS,XRD and XPS data,coatings had a developed morphology and contained hydroxyapatite,which indicates high biocompatibility.The analysis of roughness of coatings without and with vancomycin did not reveal any differences,confirming the high roughness of the samples.During electrochemical tests,an increase in corrosion resistance by more than two times after the application of PEO coatings was revealed.According to the results of an in vivo study,after 28 days of the implantation of samples with calcium phosphate PEO coating and vancomycin,no signs of inflammation were observed,while an inflammatory reaction developed in the area of implantation of bare alloy,followed by encapsulation.Antibiotic release tests from the coatings show a sharp decrease in the concentration of the released antibiotic on day 7 and then a gradual decrease until day 28.Throughout the experiment,no significant deviations in the condition and behavior of the animals were observed;clinical tests did not reveal a systemic toxic reaction.
基金the Australian Research Council(ARC)through the discovery grant DP210101862。
文摘Biodegradable implants from magnesium(Mg)alloys have emerged in the biomedical field especially in the orthopedic and cardiovascular stent applications owing to their low density,high specific strength,excellent machinability,good biocompatibility,and biodegradability.The primary shortcoming of Mg-based implants is their low corrosion resistance in the physiological environment,which results in premature mechanical integrity loss before adequate healing and the production of excessive hydrogen gas,which is harmful to the body tissues and negatively affects the biocompatibility of the implant.Laser surface modification has recently received attention because it can improve the surface properties such as surface chemistry,roughness,topography,corrosion resistance,wear resistance,hydrophilicity,and thus cell response to the surface of the material.The composition and microstructures including textures and phases of laser-treated surfaces depend largely on the laser processing parameters(input laser power,laser scan velocity,frequency,pulse duration,pressure,gas circulation,working time,spot size,beam focal position,and laser track overlap)and the thermophysical properties of the substrate(solubility,melting point,and boiling point).This review investigates the impacts of various laser surface modification techniques including laser surface melting,laser surface alloying,laser cladding,laser surface texturing,and laser shock peening,and highlights their significance in improving the surface properties of biodegradable Mg alloys for implant applications.Additionally,we explore how different laser process parameters affect its composition,microstructure,and surface properties in each laser surface modification technique.
基金the financial support by the Natural Science Foundation of Ningxia(Grant no.2022AAC03099)the Key R&D Project of Ningxia(Grant no.2020BDE03012)。
文摘Corrosion-resistant and biocompatible films were fabricated on AZ91D Mg alloy substrates by varying their roughness levels using met-allographic preparation and subsequent hydrothermal procedures.The coated films comprised a mixed structure of Mg(OH)_(2)and Mg-Al layered double hydroxides(LDH)and exhibited excellent compactness.Coating film thickness increased with decreasing surface roughness.Corrosion resistance was evaluated using potentiodynamic polarization and electrochemical impedance spectroscopy.Metallographic pretreat-ment influenced the chemical activity of the Mg alloy surface and helped modulate the dissolution rate of the Mg_(17)Al_(12)phase during the hydrothermal procedure.With decreasing roughness of the Mg substrate,the Al^(3+)concentration gradually increased,accelerating the in-situ formation of the Mg(OH)_(2)/LDH composite coating and improving its crystallinity.A thick and dense Mg(OH)_(2)/LDH coating was synthesized on the Mg substrate with the least roughness,substantially improving the corrosion resistance of the AZ91D alloy.The lowest corrosion current density((5.73±2.75)×10^(−8)A·cm^(−2))was achieved,which was approximately three orders of magnitude less than that of bare AZ91D.Moreover,the coating demonstrated biocompatibility with no evident cytotoxicity,cellular damage,and hemolytic phenomena.This study provides an effective method for preparing coatings on Mg alloy surfaces with excellent corrosion resistance and biocompatibility.
基金financially supported by the National Natural Science Foundation of China(No.52375370)the Natural Science Research General Program of Shanxi Province,China(No.202103021224048)+1 种基金the Shanxi Province Patent Transformation Project(No.202406019)the Shanxi-Zhejiang University New Materials and Chemical Research Institute Scientific Research Project(No.2022SXTD025).
文摘Zinc-based composites represent promising materials for orthopedic implants owing to their adjustable degradation rates and excellent biocompatibility.In this study,a series of Zn-10Mg-xHA(x=0-5 wt.%)composites with the core-shell structure were prepared through spark plasma sintering,and their microstructural,mechanical,and in vitro properties were systematically evaluated.Results showed that the doped hydroxyapatite(HA)is concentrated at the outer edge of the MgZn2 shell layer.The compression strength of the Zn-1oMg HA composite gradually decreased with the increase of the HA content,while its corrosion rate decreased initially and then increased.The corrosion resistance of the composite with the addition of 1 wt.%HA was improved compared to that of Zn-10Mg-0HA.However,the further increase of the HA content beyond 1 wt.%resulted in a faster degradation of the composite.Moreover,the Zn-10Mg-1HA composite significantly enhanced the activity of Mc3T3-E1 osteoblasts.Based on such findings,it is revealed that the composite containing 1 wt.%HA exhibits superior overall properties and is anticipated to serve as a promising candidate for bone implantmaterials.
基金supported by the Hunan Provincial Science and Technology Department Project(2015WK3012)the National Natural Science Foundation of China(No.81571021)+3 种基金R&D of Key Project of Hunan Provincial Science and Technology Department(2022SK2010)R&D of Key Technology of Light Metal Air Battery,Transformation and Industrialization of Scientific and Technological Achievements of Hunan Province(2020GK2071)R&D of Key Technology and Materials of Magnesium Air Battery,Transformation of Scientific and Technological Achievements of Changsha City(Kh2005186)Technology Fundation(2021JCJQ-JJ-0432)。
文摘The repair and regeneration of bone defects are highly challenging orthopedic problems.Recently,Mg-based implants have gained popularity due to their unique biodegradation and elastic modulus similar to that of human bone.The aim of our study is to develop a magnesium alloy with a controllable degradation that can closely match bone tissue to help injuries heal in vivo and avoid cytotoxicity caused by a sudden increase in ion concentration.In this study,we prepared and modified Mg-3Zn,Mg-3Zn-1Y,and Mg-2Zn-1Mn by hot extrusion,and used Mg-2.5Y-2.5Nd was as a control.We then investigated the effect of additions of Y and Mn on alloys'properties.Our results show that Mn and Y can improve not only compression strength but also corrosion resistance.The alloy Mg-2Zn-1Mn demonstrated good cytocompatibility in vitro,and for this reason we selected it for implantation in vivo.The degraded Mg-2Zn-1Mn implanted a bone defect area did not cause obvious rejection and inflammatory reaction,and the degradation products left no signs of damage to the heart,liver,kidney,or brain.Furthermore,we find that Mg-2Zn-1Mn can promote an osteoinductive response in vivo and the formation of bone regeneration.
基金the Ministry of Science,Technological Development and Innovation of the Republic of Serbia(No.451-03-47/2023-01/200017)the PhD fellowship of Slađana LAKETIĆ.Authors would also like to acknowledge the help of Dr.Anton HOHENWARTER from the Department of Materials Science,Montanuniversitat Leoben,Austria,during the Ti−45Nb alloy microstructural analysis.
文摘The Ti−45Nb(wt.%)alloy properties were investigated in relation to its potential biomedical use.Laser surface modification was utilized to improve its performance in biological systems.As a result of the laser treatment,(Ti,Nb)O scale was formed and various morphological features appeared on the alloy surface.The electrochemical behavior of Ti−45Nb alloy in simulated body conditions was evaluated and showed that the alloy was highly resistant to corrosion deterioration regardless of additional laser surface modification treatment.Nevertheless,the improved corrosion resistance after laser treatment was evident(the corrosion current density of the alloy before laser irradiation was 2.84×10^(−8)A/cm^(2),while that after laser treatment with 5 mJ was 0.65×10^(−8)A/cm^(2))and ascribed to the rapid formation of a complex and passivating bi-modal surface oxide layer.Alloy cytotoxicity and effects of the Ti−45Nb alloy laser surface modification on the MRC-5 cell viability,morphology,and proliferation were also investigated.The Ti−45Nb alloy showed no cytotoxic effect.Moreover,cells showed improved viability and adherence to the alloy surface after the laser irradiation treatment.The highest average cell viability of 115.37%was attained for the alloy laser-irradiated with 15 mJ.Results showed that the laser surface modification can be successfully utilized to significantly improve alloy performance in a biological environment.
基金the project Ferr Mion of the Ministry of Education,Youth and Sports,Czech Republic,co-funded by the European Union(CZ.02.01.01/00/22_008/0004591)the support of The Charles University Grant Agency in the frame of the project No.121724 and the project Cooperatio No.207030 Dental Medicine/LF1 of the Charles University+4 种基金financial support from the Ministry of Education,Youth and Sport of the Czech Republic under the grant No.RVO 14000supported by the Ministry of Health of the Czech Republic-RVO project VFN64165the support of the project GAMA 2 of the Technology Agency of the Czech Republic No.TP01010055the project of the Czech Academy of Sciences,Czech Republic(Praemium Academiae grant No.AP2202)the support of the Ministry of Health of the Czech Republic,grant project No.NU20-08-00150。
文摘Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation.However,localized corrosion and H_(2)generation limit the potential of Mg-based implants.Utilizing low-alloyed Mg-Zn wires can strongly reduce problems with large H_(2)bubbles and improve the mechanical properties considerably while maintaining excellent long-term biocompatibility.Acidic pickling and a polymer coating can be effectively used to lower the rate of in vivo degradation.In this work,microstructural,mechanical,and in vitro characterization of 250μm and 300μm extruded wires made from ultra-pure Mg,commercially pure Mg,Mg-0.15Zn,Mg-0.4Zn and Mg-1Zn was performed.Additionally,Mg-0.4Zn wires together with a variant coated with a copolymer of L-lactide andε-caprolactone were tested in vivo on artificially damaged Wistar rat femurs.Based on the observed Mg-induced osteogenesis,polymer-coated Mg wires with a small addition of Zn are a perspective material for bone-support applications,such as cerclage and fixation wires.
基金Supported by the National Natural Science Foundation of China(No.52073181,No.52273134).
文摘AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis.
基金funded by Ministry of Higher Education(MOHE),Malaysia-Prototype Development Research Grant Scheme,Grant Number PRGS/1/2020/STG05/UM/02/1.
文摘The study focuses on the development of biocompatible and stable FA-functionalized nanocrystalline cellulose(NCC)as a potential drug delivery system for targeting folate receptor-positive cancer cells.The FA-functionalized NCCs were synthesized through a series of chemical reactions,resulting in nanoparticles with favorable properties for biomedical applications.The microstructural analysis revealed that the functionalized NCCs maintained their rod-shaped morphology and displayed hydrodynamic diameters suitable for evading the mononuclear phagocytic system while being large enough to target tumor tissues.Importantly,these nanoparticles possessed a negative surface charge,enhancing their stability and repelling potential aggregation.The binding specificity of FA-functionalized NCCs to folate receptor-positive cancer cells was demonstrated through various assays.The free folic acid inhibition assay showed approximately 30%decrease in the binding of functionalized NCCs in the presence of just 5 mM free FA,confirming their selectivity for folate receptor-positive cells.Confocal microscopy further validated this specificity,as only cancer cells displayed significant binding of functionalized NCCs.Crucially,biocompatibility tests revealed that both NCCs and FA-functionalized NCCs had minimal effects on red blood cells,and they did not induce erythrocyte aggregation.Furthermore,cell viability assays demonstrated functionalized NCCs have selective cytotoxicity against colorectal cancer cells HT-29 and SW-620(68%–88%cell viability)while sparing noncancerous colon cells CCD-18Co(81%–97%cell viability).In summary,FA-functionalized NCCs exhibit promising characteristics for targeted drug delivery in cancer therapy.Their biocompatibility,stability,and selective cytotoxicity make them an attractive option for delivering therapeutic agents to folate receptor-positive cancer cells,potentially improving the effectiveness of cancer treatments while minimizing harm to healthy tissues.
文摘Bone regeneration is a critical area in regenerative medicine,particularly in orthopedics,demanding effective biomedical materials for treating bone defects.45S5 bioactive glass(45S5 BG)is a promising material because of its osteoconductive and bioactive properties.As research in this field continues to advance,keeping up-to-date on the latest and most successful applications of this material is imperative.To achieve this,we conducted a comprehensive search on Pub-Med/MEDLINE,focusing on English articles published in the last decade.Our search used the keywords“bioglass 45S5 AND bone defect”in combination.We found 27 articles,and after applying the inclusion criteria,we selected 15 studies for detailed examination.Most of these studies compared 45S5 BG with other cement or scaffold materials.These comparisons demonstrate that the addition of various composites enhances cellular biocompatibility,as evidenced by the cells and their osteogenic potential.Moreover,the use of 45S5 BG is enhanced by its antimicrobial properties,opening avenues for additional investigations and applications of this biomaterial.
文摘Biodegradable magnesium alloys have been widely used in medical implants. But safety concerns were put forward for the high degradation rate of biodegradable magnesium alloy. The optimal biodegradable magnesium alloys that give rise to the desired degradation rate hasn’t yet to be defined. Assessing the degradation rate of biodegradable magnesium alloys involves in vitro testing, in vivo testing, numerical modeling, understanding the factors influencing their degradation in physiological environments, biocompatibility testing, and clinical studies. It is important to standardize analytical tools aimed at assessing the degradation rate of biodegradable magnesium alloys. It is advisable to identify the threshold for safe degradation rate of biodegradable magnesium alloys in biomedical applications.