Based on the Canadian Standards Association (CSA) criteria,105 pullout specimens were tested to investigate the effect of different rib geometries on bond strength of glass fiber reinforced polymer (GFRP) rebars embed...Based on the Canadian Standards Association (CSA) criteria,105 pullout specimens were tested to investigate the effect of different rib geometries on bond strength of glass fiber reinforced polymer (GFRP) rebars embedded in concrete. Two kinds of conventional reinforcing rebars were also studied for comparison. Each rebar was embedded in a 150 mm concrete cube,with the embedded length being four times the rebar diameter. The experimental parameters were the rebar type,rebar component,rebar diameter,rebar surface texture,rib height,rib spacing and rib width. Theoretical analysis was also carried out to explain the experimental phenomena and results. The experimental and theoretical results indicated that the bond strength of GFRP rebars was about 13%~35% lower than that of steel rebars. The bond strength and bond-slip behavior of the specially machined rebars varied with the rebar type,rebar diameter,rebar surface texture,rib height,rib spacing and rib width. Using the results,design recom-mendations were made concerning optimum rib geometries of GFRP ribbed rebars with superior bond-slip characteristics,which concluded that the optimal rib spacing of ribbed rebars is the same as the rebar diameter,and that the optimal rib height is 6% of the rebar diameter.展开更多
In order to investigate the tensile bond anchorage properties of Australian 500N steel bars in concrete, 111 pullout tests were conducted. The precise bond slip values have been gained by using the laser displacement ...In order to investigate the tensile bond anchorage properties of Australian 500N steel bars in concrete, 111 pullout tests were conducted. The precise bond slip values have been gained by using the laser displacement sensor with high resolution, including the complete bond-slip curves. How the main anchorage factors such as concrete strength, bar diameter (8, I0, 12, 16, 20, 24, 28, 32 and 36 mm) the concrete covered, embedded length and transverse reinforcement influencing the bond anchorage properties was studied under tensile condition. The process of the tensile force-slip failure for Australian 500N reinforcing steel can be divided into five stages: elastic stage, local slip stage, slip in ascent stage, slip in descent stage and remnant stage. The formula for calculating the tensile bond strength of Australian 500N reinforcing bar in concrete was proposed according to the test results, including the consistent model for tensile bond-slip relationship.展开更多
Since last two decades,the Portland Pozzolane Cement(PPC)is extensively used in structural concrete.But,till to date,a few literature is available on bond strength of concrete using PPC mixes.There are many literature...Since last two decades,the Portland Pozzolane Cement(PPC)is extensively used in structural concrete.But,till to date,a few literature is available on bond strength of concrete using PPC mixes.There are many literatures available on bond strength of concrete mixes using Ordinary Portland Cement(OPC).Hence,a comparative study was conducted on bond strength between OPC and PPC mixes.In the present investigation,total 24 samples consisting of M20,M35 and M50 grades of concrete and 16 and 25 mm diameter of TMT bar were tested for 7 and 28 days.The pullout bond test was conducted on each specimen as per IS:2770-1967/1997[1]and the results were observed at 0.25 mm slip at loaded end called as critical bond stress and at maximum bond load called as maximum bond stress.It was observed that the critical bond strength of PPC mixes is 10%higher than OPC mixes.Whereas,marginal improvement was noticed in maximum bond strength of PPC mixes.Hence,based on these findings,it could be concluded that development length for PPC mixes could be reduced by 10%as compared with same grade of OPC mixes.展开更多
基金Project (No. 200431882021) supported by the Western Communi-cation Construction and Science & Technological Project,China
文摘Based on the Canadian Standards Association (CSA) criteria,105 pullout specimens were tested to investigate the effect of different rib geometries on bond strength of glass fiber reinforced polymer (GFRP) rebars embedded in concrete. Two kinds of conventional reinforcing rebars were also studied for comparison. Each rebar was embedded in a 150 mm concrete cube,with the embedded length being four times the rebar diameter. The experimental parameters were the rebar type,rebar component,rebar diameter,rebar surface texture,rib height,rib spacing and rib width. Theoretical analysis was also carried out to explain the experimental phenomena and results. The experimental and theoretical results indicated that the bond strength of GFRP rebars was about 13%~35% lower than that of steel rebars. The bond strength and bond-slip behavior of the specially machined rebars varied with the rebar type,rebar diameter,rebar surface texture,rib height,rib spacing and rib width. Using the results,design recom-mendations were made concerning optimum rib geometries of GFRP ribbed rebars with superior bond-slip characteristics,which concluded that the optimal rib spacing of ribbed rebars is the same as the rebar diameter,and that the optimal rib height is 6% of the rebar diameter.
基金Project(DP0988940) supported by Australian Research Council Discovery Grant Program Project(2011M500930) supported by Postdoctoral Science Foundation of China+1 种基金Project(11KJB560003) supported by College Natural Science Foundation of Jiangsu Province,ChinaProject(163050072) supported by the Talent Introduction Foundation of Nanjing Forestry University,China
文摘In order to investigate the tensile bond anchorage properties of Australian 500N steel bars in concrete, 111 pullout tests were conducted. The precise bond slip values have been gained by using the laser displacement sensor with high resolution, including the complete bond-slip curves. How the main anchorage factors such as concrete strength, bar diameter (8, I0, 12, 16, 20, 24, 28, 32 and 36 mm) the concrete covered, embedded length and transverse reinforcement influencing the bond anchorage properties was studied under tensile condition. The process of the tensile force-slip failure for Australian 500N reinforcing steel can be divided into five stages: elastic stage, local slip stage, slip in ascent stage, slip in descent stage and remnant stage. The formula for calculating the tensile bond strength of Australian 500N reinforcing bar in concrete was proposed according to the test results, including the consistent model for tensile bond-slip relationship.
文摘Since last two decades,the Portland Pozzolane Cement(PPC)is extensively used in structural concrete.But,till to date,a few literature is available on bond strength of concrete using PPC mixes.There are many literatures available on bond strength of concrete mixes using Ordinary Portland Cement(OPC).Hence,a comparative study was conducted on bond strength between OPC and PPC mixes.In the present investigation,total 24 samples consisting of M20,M35 and M50 grades of concrete and 16 and 25 mm diameter of TMT bar were tested for 7 and 28 days.The pullout bond test was conducted on each specimen as per IS:2770-1967/1997[1]and the results were observed at 0.25 mm slip at loaded end called as critical bond stress and at maximum bond load called as maximum bond stress.It was observed that the critical bond strength of PPC mixes is 10%higher than OPC mixes.Whereas,marginal improvement was noticed in maximum bond strength of PPC mixes.Hence,based on these findings,it could be concluded that development length for PPC mixes could be reduced by 10%as compared with same grade of OPC mixes.