期刊文献+
共找到29,606篇文章
< 1 2 250 >
每页显示 20 50 100
Experimental Study on Ammonia Co-Firing with Coal for Carbon Reduction in the Boiler of a 300-MW Coal-Fired Power Station
1
作者 Qifu Lin Wangping Sun +15 位作者 Haiyan Li Yangjiong Liu Yuwei Chen Chengzhou Liu Yiman Jiang Yu Cheng Ning Ma Huaqing Ya Longwei Chen Shidong Fang Hansheng Feng Guang-Nan Luo Jiangang Li Kaixin Xiang Jie Cong Cheng Cheng 《Engineering》 SCIE EI CAS CSCD 2024年第9期247-259,共13页
To reduce CO_(2) emissions from coal-fired power plants,the development of low-carbon or carbon-free fuel combustion technologies has become urgent.As a new zero-carbon fuel,ammonia(NH_(3))can be used to address the s... To reduce CO_(2) emissions from coal-fired power plants,the development of low-carbon or carbon-free fuel combustion technologies has become urgent.As a new zero-carbon fuel,ammonia(NH_(3))can be used to address the storage and transportation issues of hydrogen energy.Since it is not feasible to completely replace coal with ammonia in the short term,the development of ammonia-coal co-combustion technology at the current stage is a fast and feasible approach to reduce CO_(2) emissions from coal-fired power plants.This study focuses on modifying the boiler and installing two layers of eight pure-ammonia burners in a 300-MW coal-fired power plant to achieve ammonia-coal co-combustion at proportions ranging from 20%to 10%(by heat ratio)at loads of 180-to 300-MW,respectively.The results show that,during ammonia-coal co-combustion in a 300-MW coal-fired power plant,there was a more significant change in NO_(x) emissions at the furnace outlet compared with that under pure-coal combustion as the boiler oxygen levels varied.Moreover,ammonia burners located in the middle part of the main combustion zone exhibited a better high-temperature reduction performance than those located in the upper part of the main combustion zone.Under all ammonia co-combustion conditions,the NH_(3) concentration at the furnace outlet remained below 1 parts per million(ppm).Compared with that under pure-coal conditions,the thermal efficiency of the boiler slightly decreased(by 0.12%-0.38%)under different loads when ammonia co-combustion reached 15 t·h^(-1).Ammonia co-combustion in coal-fired power plants is a potentially feasible technology route for carbon reduction. 展开更多
关键词 Coal-fired boiler Coal mixing with ammonia Ammonia-coal co-firing Nitrogen oxide(NO_(x)) CO_(2)reduction boiler thermal efficiency
下载PDF
Effects of particle type on the particle fluidization and distribution in a liquid–solid circulating fluidized bed boiler
2
作者 Feng Jiang Xiao Li +1 位作者 Guopeng Qi Xiulun Li 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第2期53-66,共14页
A liquid-solid circulating fluidized bed boiler is designed and built for visualization research by applying the fluidized bed heat transfer and fouling prevention technology to the water side of the boiler. Four type... A liquid-solid circulating fluidized bed boiler is designed and built for visualization research by applying the fluidized bed heat transfer and fouling prevention technology to the water side of the boiler. Four types of engineering plastic particles with different physical properties are selected as the solid working media. The effect of particle types on the fluidization and distribution of particles in the boiler is investigated under different feedwater flow rates and amount of added particles by using the charge couple device image measurement and acquisition system. The results show that all kinds of particles can't be normally fluidized and accumulate in the drum at low amount of added particles and feedwater flow rate. The particles with great density and low sphericity are more likely to accumulate. The average solid holdup in the riser tubes increases with the increase in feedwater flow rate and the amount of added particles. The non-uniform degree of particle distribution in the riser tubes generally decreases with the increase in feedwater flow rate and the amount of added particles. The particles with small density and settling velocity have high average solid holdup in the riser tubes under close sphericity. In generally,the smaller the density and settling velocity, the more uniform the particle distribution in the riser tubes.Three-dimensional diagrams of the non-uniform degree of particle distribution in the riser tubes of the boiler are established. 展开更多
关键词 Circulating fluidized bed boiler Particle type Particle distribution Visualization Fouling prevention
下载PDF
Environmental performance assessments of different methods of coal preparation for use in small-capacity boilers: experiment and theory
3
作者 A.N.Kozlov E.P.Maysyuk I.Yu.Ivanova 《International Journal of Coal Science & Technology》 EI CAS CSCD 2023年第5期57-71,共15页
The purpose of this article is to receive environmental assessments of combustion of different types of coal fuel depending on the preparation(unscreened,size-graded,briquetted and heat-treated)in automated boilers an... The purpose of this article is to receive environmental assessments of combustion of different types of coal fuel depending on the preparation(unscreened,size-graded,briquetted and heat-treated)in automated boilers and boilers with manual load-ing.The assessments were made on the basis of data obtained from experimental methods of coal preparation and calculated methods of determining the amount of pollutant and greenhouse gas emissions,as well as the mass of ash and slag waste.The main pollutants from coal combustion are calculated:particulate matter,benz(a)pyrene,nitrogen oxides,sulfur dioxide,carbon monoxide.Of the greenhouse gases carbon dioxide is calculated.As a result of conducted research it is shown that the simplest preliminary preparation(size-graded)of coal significantly improves combustion efficiency and environmental performance:emissions are reduced by 13%for hard coal and up to 20%for brown coal.The introduction of automated boil-ers with heat-treated coal in small boiler facilities allows to reduce emissions and ash and slag waste by 2-3 times.The best environmental indicators correspond to heat-treated lignite,which is characterized by the absence of sulfur dioxide emissions. 展开更多
关键词 Coal preparation Automated and hand-fed coal boilers Environmental performance metrics
下载PDF
Investigation of the Effects of a Large Percentage of Dried Sludge on the Operation of a Coal-Fired Boiler
4
作者 Jialin Tong Yan Zhang +2 位作者 Ruikang Wu Xiaojuan Qi Xuemin Ye 《Fluid Dynamics & Materials Processing》 EI 2023年第4期1027-1041,共15页
A 600 MW coal-fired boiler with a four-corner tangential combustion mode is considered here to study the combustion features and pollutant emissions at different loads for large-percentages of blending dried sludges.T... A 600 MW coal-fired boiler with a four-corner tangential combustion mode is considered here to study the combustion features and pollutant emissions at different loads for large-percentages of blending dried sludges.The influence of the over-fired air(OFA)coefficient is examined and the impact of the blending ratio on the boiler operation is explored.The results show that for low blending ratios,a slight increase in the blending ratio can improve the combustion of bituminite,whereas a further increase leads to the deterioration of the combustion of blended fuels and thus reduces the boiler efficiency.Enhancing the supporting capability of the secondary air effectively reduces the slagging degree in the bottom ash hopper and improves the burnout rate of coals.For a large-percentage blending case at full load,it is found that the OFA coefficient must be reduced appropriately,otherwise,a secondary high-temperature combustion zone can be generated in the vicinity of the furnace arches,causing high temperature slagging and superheater tube bursting.Considering the influences of combustion and pollutant emissions,the recommended OFA coefficient is 0.2.Blending dried sludge under low loads increases the flue gas temperature at the furnace exit.While reducing the flue gas temperature in the main combustion region,which is beneficial to the safe operation of the denitrification system.Increasing the blending ratio and reducing load lead to an increase in NOx concentration at the furnace exit Sludges with low nitrogen content are suggested for the practical operation of boilers. 展开更多
关键词 Blending ratio boiler load COMBUSTION pollutant emission over-fired air(OFA)coefficient numerical simulation
下载PDF
800-MW Supercritical Coal-Fired Boilers in Suizhong Power Plant
5
作者 ZouHaifeng LiZhishan LiuZhongqi 《Electricity》 2005年第2期30-33,共4页
This article reviews the problems of Russia-made 800-MW coal-fired supercritical boilers in Suizhong Power Plant, such as burner bumout, water-wall leakage, slag screenⅠexplosion, crack happened on the desuperheater ... This article reviews the problems of Russia-made 800-MW coal-fired supercritical boilers in Suizhong Power Plant, such as burner bumout, water-wall leakage, slag screenⅠexplosion, crack happened on the desuperheater outlet of reheater and welding defect of economizer; tells the process of renovating these units by modifying the original design and adjusting the operation parameters. After several years' effort, all the problems have been well solved. The experience may be useful for other imported units in China. 展开更多
关键词 supercritical boiler boiler operation boiler tube leakage
下载PDF
Numerical Calculations and Cold Tests for Flow Fields of a 220t/h Retrofitted Oil-Boiler
6
作者 朱世钧 程永元 +1 位作者 蔡崧 肖军 《Journal of Southeast University(English Edition)》 EI CAS 2000年第1期70-74,共5页
In this paper, cold simulation experiments and numerical calculations are conducted to predict 3 D flow field aerodynamics for an oil furnace after being retrofitted due to its fuel variation. K ε model and SIMPLE ... In this paper, cold simulation experiments and numerical calculations are conducted to predict 3 D flow field aerodynamics for an oil furnace after being retrofitted due to its fuel variation. K ε model and SIMPLE program under body fit coordination (BFC) system, in which TTM non orthogonal method is used to control the irregular geometric boundary, are adopted to solve the control equations. Model tests are conducted to check the calculation results, showing that they are in agreement with each other. Three different alternatives with different side window locations are also calculated to optimize the designs. The field retrofitting results show that the combination of cold tests with numerical calculations has prosperous application in retrofitting or renewing medium and small boilers. 展开更多
关键词 cold model test numerical calculation BFC boiler retrofitting
下载PDF
Modeling and Simulation Study on Reverse Swirl of Secondary Air in Large Tangentially Fired Boiler
7
作者 李彦鹏 张强 +1 位作者 顾璠 徐益谦 《Journal of Southeast University(English Edition)》 EI CAS 2000年第2期87-94,共8页
Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is ap... Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is applied to a 600?MW boiler modeling under different operating conditions of reverse swirl of secondary air. The numerical results achieve reasonable agreement with experimental data. The calculated results of flow field, the pressure distribution, the relative diameter of tangential circle, angular momentum flux in furnace and the velocity distribution index in horizontal gas pass are analyzed in detail. And then the effects of the reverse swirl of secondary air on flue gas imbalance are discussed. Finally a reasonable operating condition of the reverse swirl of secondary air is presented. 展开更多
关键词 tangentially fired boiler flue gas imbalance reverse swirl of secondary air numerical simulation
下载PDF
Three-Dimensional Dynamic Modeling of a Tangentially Fired Utility Boiler Furnace
8
作者 冷伟 徐治皋 《Journal of Southeast University(English Edition)》 EI CAS 2002年第4期315-318,共4页
The tangentially fired utility boiler furnace is divided into several sections. The dynamic mathematical models for each section are presented. In the combustion zone, three dimensional model is used, while for the up... The tangentially fired utility boiler furnace is divided into several sections. The dynamic mathematical models for each section are presented. In the combustion zone, three dimensional model is used, while for the upper sections, lumped parameter model is used instead. With the combination of different models, we can get detailed distributions of gas velocity, temperature, chemical species, heat flux, etc. in the furnace, but with less CPU time. The radiation through the interfaces of each section is cons... 展开更多
关键词 dynamic model numerical simulation boiler FURNACE
下载PDF
Neural network approach to predicting mercury emission from utility boiler
9
作者 杨宏旻 周波 《Journal of Southeast University(English Edition)》 EI CAS 2008年第1期55-58,共4页
The feasibility of using an ANN method to predict the mercury emission and speciation in the flue gas of a power station under un-tested combustion/operational conditions is evaluated. Based on existing field testing ... The feasibility of using an ANN method to predict the mercury emission and speciation in the flue gas of a power station under un-tested combustion/operational conditions is evaluated. Based on existing field testing datasets for the emissions of three utility boilers, a 3-layer back-propagation network is applied to predict the mercury speciation at the stack. The whole prediction procedure includes: collection of data, structuring an artificial neural network (ANN) model, training process and error evaluation. A total of 59 parameters of coal and ash analyses and power plant operating conditions are treated as input variables, and the actual mercury emissions and their speciation data are used to supervise the training process and verify the performance of prediction modeling. The precision of model prediction ( root- mean-square error is 0. 8 μg/Nm3 for elemental mercury and 0. 9 μg/Nm3 for total mercury) is acceptable since the spikes of semi- mercury continuous emission monitor (SCEM) with wet conversion modules are taken into consideration. 展开更多
关键词 mercury speciations electric utility boiler PREDICTION artificial neural network
下载PDF
Analysis of Prese nt Operating Situati on of Large Size Coal-F ired Utility Boilers
10
作者 许传凯 袁颖 《Electricity》 2003年第1期24-29,共6页
Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, i... Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, it is held that, the notable energy imbalance of furnace exit, ever existing in the tangential firing boilers has been solved, with comparatively lower NOX emission concentration of gained. The higher NOX emission concentration and furnace slagging etc. problems existing in wall firing boilers are notable. The comprehensive analysis shows that, it is appropriate to choose lower furnace volume heat release rate and higher flame height in the type selection design of boilers, and sufficient margin should be kept in the selection of coal pulverizing mills. 展开更多
关键词 coal-fired boiler operating performance COMBUSTION slagging and fouling NOX emission
下载PDF
Characteristics of Phosphorus Adsorption with Boiler Slag and Process Optimization 被引量:3
11
作者 梁思华 余光伟 +3 位作者 林佩祯 种云霄 崔理华 邱兰 《Agricultural Science & Technology》 CAS 2012年第7期1547-1549,1565,共4页
[Objective] This study aimed to investigate the characteristics of phosphorus adsorption on boiler slag and optimize the adsorption process. [Method] Boiler slag was used as an adsorbent in the single-grade adsorption... [Objective] This study aimed to investigate the characteristics of phosphorus adsorption on boiler slag and optimize the adsorption process. [Method] Boiler slag was used as an adsorbent in the single-grade adsorption process to dispose the rural domestic sewage. During the course, phosphorus adsorption kinetics and thermodynamics, adsorption operating curve and the minimum boiler slag dosage were analyzed and calculated. [Result] Langmuir adsorption isotherm could be applied to describe the absorption of phosphorus with boiler slag, and the absorption kinetics was confirmed with the pseudo second-order equation. The maximum absorption quantity and the initial absorption rate increased with the rise of temperature, reaching up to 0.159 1 mg/g and 0.169 8 mg/(g·min) respectively at 40 ℃. Thermodynamic variables ΔG0<0 and ΔH0>0 indicated that the entire process was a spontaneous endothermic reaction, and high temperature would facilitate the reaction of absorption. In the single grade adsorption, the minimum adsorbent dosage decreased as the temperature rose; at 40 ℃ the optimum mass ratio of boiler slag to wastewater was 3.31 kg/m3. [Conclusion] The adsorption process with boiler slag as adsorbent is an economical and effective approach for treating rural domestic sewage. 展开更多
关键词 Rural domestic sewage boiler slag PHOSPHORUS Single grade adsorption KINETICS THERMODYNAMICS
下载PDF
Model prediction of the operating behavior of a circulating fluidized bed boiler
12
作者 王勤辉 骆仲泱 +1 位作者 倪明江 岑可法 《Journal of Zhejiang University Science》 CSCD 2002年第3期251-257,共7页
An improved mathematical model for a circulating fluidized bed (CFB) boiler based on the model developed earlier by the authors was applied to simulate the operation of a 12 MW CFB boiler. The influences of the excess... An improved mathematical model for a circulating fluidized bed (CFB) boiler based on the model developed earlier by the authors was applied to simulate the operation of a 12 MW CFB boiler. The influences of the excess air ratio, primary air ratio, coal particle size distribution, coal properties (ash content and volatile content) and Ca/S ratio on the boiler operation were analyzed. The results showed that the model simulation may be applied to the optimum design and economic operation of the CFB boiler. 展开更多
关键词 Circulating fluidized bed boiler(CFB) MODEL boiler operation
下载PDF
Boiler-turbine control system design using continuous-time nonlinear model predictive control
13
作者 卓旭升 周怀春 《Journal of Chongqing University》 CAS 2008年第2期113-118,共6页
A continuous-time nonlinear model predictive controller(NMPC) was designed for a boiler-turbine unit.The controller was designed by optimizing a receding-horizon performance index,with the nonlinear system approximate... A continuous-time nonlinear model predictive controller(NMPC) was designed for a boiler-turbine unit.The controller was designed by optimizing a receding-horizon performance index,with the nonlinear system approximated by its Taylor series expansion with a certain order,the magnitude saturation constraints on the inputs satisfied by increasing the predictive time,and the rate saturation conditions on the actuators satisfied by tuning the time constant of the reference trajectories in a reference governor.Simulation results showed that the controller can drive the drum pressure and output power of the nonlinear boiler-turbine unit to follow their respective reference trajectories throughout a varying operation range and keep the water level deviation within tolerances.Comparison of the NMPC scheme with the generic model control(GMC) scheme indicated that the responses are slower and there are more oscillations in the responses of the water level,fuel flow input and feed water flow input in the GMC scheme when the boiler-turbine unit is operating over a wide range. 展开更多
关键词 nonlinear control system boiler control boiler-turbine unit nonlinear model predictive control reference governor generic model control
下载PDF
Development of 600 MW Class Coal Fired Boilers in China
14
作者 Xu Chuankai Xu Yunsong(Thermal Power Research institute, Xi’an, China) 《Electricity》 1999年第3期16-22,共7页
This article introduces the present status anddevelopment of 600 MW class boilers in China. The statisticaldata indicate that most 600 MW generating units experiencedrelatively length" growing up" period. In... This article introduces the present status anddevelopment of 600 MW class boilers in China. The statisticaldata indicate that most 600 MW generating units experiencedrelatively length" growing up" period. In this period, unitscould not operate stably , their unplanned outage times weremany and durations long, and availabilities low. On the basis oftesting and research and the summing-up of practice, it wasindicated slagging in the furnace, deviation of tine gas energy atthe exit of furnace, and overheating bursting of superheater andreheater etc, endangering the safety and economics ofoperation,main problems could be completely alleviated oravoided through design and type selection of boiler furnace andburners, coal characteristics and coal handling management,and optimization management of operation conditions etc. 展开更多
关键词 coal-fired boiler SLAGGING energy deviation of fluegas tube failure coupling of COAL property-boiler type
下载PDF
Efficiency in Boiler Feed Pumps for Industrial Steam Generation
15
作者 Guilherme Filippo Fi|ho 《Journal of Energy and Power Engineering》 2014年第6期1021-1029,共9页
This paper presents some opportunities to improve feedwater system efficiency for industrial boilers, usually consisting of multistage centrifugal pumps driven by three-phase induction motors. There is abundant litera... This paper presents some opportunities to improve feedwater system efficiency for industrial boilers, usually consisting of multistage centrifugal pumps driven by three-phase induction motors. There is abundant literature on the efficiency in steam boilers. However, few deal exclusively with feedwater systems. The total horsepower in boiler feed pumps and the corresponding energy consumption estimated for Brazilian industries are as follows: 110.5 MWE of motor driven power and a yearly electricity consumption of 442 GWh for a population of 7,800 steam boilers, approximately. It is estimated that there can be an efficiency improvement in feedwater systems for industrial boilers of 30% on average. To a large extent, these opportunities reside in older boilers that are very common in the Brazilian industrial sector. The most common causes for the low efficiency of feedwater systems are: the control loop of the feedwater, oversized boilers and excessive operational pressure set. Sometimes, the boiler feedwater system can present more than one problem simultaneously. Any kind of solution involves some speed regulation, new pump and number of pumps. Each problem generation facilities were selected in which common inefficiencies cases, the improvement in efficiency can get to 37%. form of intervention in boiler feed pumps, such as: impeller trim, may have more than one solution. Three distinct industrial steam are present. The suggested solutions were analyzed. In these three 展开更多
关键词 Industrial boiler boiler feed pump industrial energy efficiency.
下载PDF
INTRODUCTION TO INCONEL ALLOY 740: AN ALLOY DESIGNED FOR SUPERHEATER TUBING IN COAL-FIRED ULTRA SUPERCRITICAL BOILERS 被引量:19
16
作者 S.J. Patel 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2005年第4期479-488,共10页
Chinese utilities as well as those worldwide are facing increased demand for additional electricity, reduced plant emissions and greater efficiency. To meet this challenge will require increasing boiler temperature, p... Chinese utilities as well as those worldwide are facing increased demand for additional electricity, reduced plant emissions and greater efficiency. To meet this challenge will require increasing boiler temperature, pressure and coal ash corrosion resistance of the materials of boiler construction of future coal-fired boilers. A new nickel-based tube alloy, INCONEL^R alloy 740, is described aiming at meeting this challenge. Emphasis will be on describing the alloy' s mechanical properties, coal-ash and steam corrosion resistance. Microstructural stability as a function of temperature and time is addressed as well as some of the early methodology em- ployed to arrive at the current chemical composition. 展开更多
关键词 ultrasupercritical boiler tubing INCONEL coal-fired
下载PDF
Corrosion Behavior of TP316L of Superheater in Biomass Boiler with Simulated Atmosphere and Deposit 被引量:11
17
作者 印佳敏 吴占松 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2009年第5期849-853,共5页
Corrosion behavior of TP316L was investigated with simulated atmosphere and ash deposition for the superheater in biomass boiler.Corrosion dynamic curves were plotted by mass gain.The results showed that the corrosion... Corrosion behavior of TP316L was investigated with simulated atmosphere and ash deposition for the superheater in biomass boiler.Corrosion dynamic curves were plotted by mass gain.The results showed that the corrosion was dependent on temperature and was greatly accelerated by ash deposition.The mass gain was distinctly reduced in the presence of SO2 with and without ash deposition on the specimens.Corrosion rates with ash deposit at different temperatures were calculated.Two feasible methods were provided to avoid serious high-temperature corrosion in the biomass boiler. 展开更多
关键词 high-temperature corrosion TP316L SUPERHEATER biomass boiler HCL
下载PDF
Surface free energy of copper-zinc alloy for energy-saving of boiler 被引量:6
18
作者 WANG Man LIANG Jinsheng +3 位作者 TANG Qingguo MING Xing MENG Junping DING Yan 《Rare Metals》 SCIE EI CAS CSCD 2006年第z1期324-327,共4页
Cu-Zn,Cu-Zn-Sn,Cu-Zn-Ni alloys were melted by vacuum smelter.The effect factors to the surface free energy of the alloys such as chemical composition,crystal structure and surface crystal lattice distortion etc.were i... Cu-Zn,Cu-Zn-Sn,Cu-Zn-Ni alloys were melted by vacuum smelter.The effect factors to the surface free energy of the alloys such as chemical composition,crystal structure and surface crystal lattice distortion etc.were investigated by OCA30 automatic contact angle test instrument,metallography microscope and XRD instrument etc.Results suggests:adding alloy element to Cu may increase its surface free energy,and the more kinds of alloy elements are added,the more surface free energy increases;the alloy element Sn an increase the surface free energy of Cu-Zn alloy;Cu-Zn alloy with fir-tree crystal structure,great phase discrepancy and obvious composition aliquation has greater surface free energy;Cu-Zn alloy with compounds and serious surface crystal lattice distortion has greater surface free energy. 展开更多
关键词 boiler water treatment Cu-Zn alloy crystal structure contact angle surface free energy ENERGY-SAVING
下载PDF
Flexibility of a 300 MW Arch Firing Boiler Burning Low Quality Coals 被引量:10
19
作者 FANG Qing-yan ZHOU Huai-chun WANG Hua-jian YAO Bin ZENG Han-cai 《Journal of China University of Mining and Technology》 EI 2007年第4期566-571,共6页
Experimental investigations on the flexibility of a 300 MW Arch Firing (AF) coal-fired boiler when burning low quality coals is reported. Measurements of gas temperature and species concentration and char sampling usi... Experimental investigations on the flexibility of a 300 MW Arch Firing (AF) coal-fired boiler when burning low quality coals is reported. Measurements of gas temperature and species concentration and char sampling using a water-cooled suction pyrometer were carried out along the furnace elevation. The carbon content and the size distribu-tions of the char samples were obtained. The char morphology was examined using a field emission scanning electron microscope (FESEM). The char sampling was performed on this type of boiler for the first time. The results indicate that the flexibility of this boiler burning low quality coals under a moderate boiler load is better than its flexibility under a high boiler load. Because of the insufficient capacity of the coal pulverizers used,in case of low coal quality the pul-verized coal fineness will drastically decrease under high boiler loads. This causes an increase in the loss due to incom-plete mechanical and chemical combustion. This is the main cause of a low burnout degree of the pulverized coal and the decrease of the flexibility of this AF boiler under a high boiler load. 展开更多
关键词 coal-fired boilers FLEXIBILITY BURNOUT TEMPERATURES size distributions
下载PDF
Sliding Mode Predictive Control of Main Steam Pressure in Coal-fired Power Plant Boiler 被引量:4
20
作者 史元浩 王景成 章云锋 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第6期1107-1112,共6页
Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportio... Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones. 展开更多
关键词 coal fired power plant boiler combustion system main steam pressure sliding mode control Smith predictor internal model control
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部