This paper is a research design based on EFPT process control device.In the design,actual industry field has been simulated and corresponding modelling has been carried on for the boiler level system.Then the appropri...This paper is a research design based on EFPT process control device.In the design,actual industry field has been simulated and corresponding modelling has been carried on for the boiler level system.Then the appropriate PID parameter has been sorted out and ControlLogix5550 PLC has been used to control the entire boiler level system. At last,a corresponding control interface has been established and the boiler level has been under a safe and accurate control.展开更多
This paper proposed a simple approach to determine noise frequency of boiler drum level in order to improve control performance. Based on analysis of uncertainty of drum level, the redundant oscillation component of s...This paper proposed a simple approach to determine noise frequency of boiler drum level in order to improve control performance. Based on analysis of uncertainty of drum level, the redundant oscillation component of signal, noise is ascribed to the surface wave of drum water. According to the characteristic of surface wave, a new method was proposed to determine noise’s frequency band. By gradually removing the lowest frequency component of signal, the variance of remained component is calculated and observed. An apparent turning point was found and the corresponding critical frequcncy was determined. With this result a low-pass filter was designed to separate noise component. Finally validation is conducted by comparing the proposed method and conventional ones. Results show the accuracy and simpleness of the proposed method.展开更多
文摘This paper is a research design based on EFPT process control device.In the design,actual industry field has been simulated and corresponding modelling has been carried on for the boiler level system.Then the appropriate PID parameter has been sorted out and ControlLogix5550 PLC has been used to control the entire boiler level system. At last,a corresponding control interface has been established and the boiler level has been under a safe and accurate control.
文摘This paper proposed a simple approach to determine noise frequency of boiler drum level in order to improve control performance. Based on analysis of uncertainty of drum level, the redundant oscillation component of signal, noise is ascribed to the surface wave of drum water. According to the characteristic of surface wave, a new method was proposed to determine noise’s frequency band. By gradually removing the lowest frequency component of signal, the variance of remained component is calculated and observed. An apparent turning point was found and the corresponding critical frequcncy was determined. With this result a low-pass filter was designed to separate noise component. Finally validation is conducted by comparing the proposed method and conventional ones. Results show the accuracy and simpleness of the proposed method.