In this paper, cold simulation experiments and numerical calculations are conducted to predict 3 D flow field aerodynamics for an oil furnace after being retrofitted due to its fuel variation. K ε model and SIMPLE ...In this paper, cold simulation experiments and numerical calculations are conducted to predict 3 D flow field aerodynamics for an oil furnace after being retrofitted due to its fuel variation. K ε model and SIMPLE program under body fit coordination (BFC) system, in which TTM non orthogonal method is used to control the irregular geometric boundary, are adopted to solve the control equations. Model tests are conducted to check the calculation results, showing that they are in agreement with each other. Three different alternatives with different side window locations are also calculated to optimize the designs. The field retrofitting results show that the combination of cold tests with numerical calculations has prosperous application in retrofitting or renewing medium and small boilers.展开更多
文摘In this paper, cold simulation experiments and numerical calculations are conducted to predict 3 D flow field aerodynamics for an oil furnace after being retrofitted due to its fuel variation. K ε model and SIMPLE program under body fit coordination (BFC) system, in which TTM non orthogonal method is used to control the irregular geometric boundary, are adopted to solve the control equations. Model tests are conducted to check the calculation results, showing that they are in agreement with each other. Three different alternatives with different side window locations are also calculated to optimize the designs. The field retrofitting results show that the combination of cold tests with numerical calculations has prosperous application in retrofitting or renewing medium and small boilers.