The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the stu...The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the study through theoretical analysis and calculation showed that such a balanced energy mix is an economic way and efficient in saving energy and reducing air pollution, and elaborated the theoretical feasibility of popularizing such a heat supply mode in rural areas.展开更多
A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the s...A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the system had been examined. And the results also support theoretical feasibility of the system.展开更多
Flue gas heat loss accounts for a significant component of theoverall heat loss for coal-fired boilers in power plants. The flue gas absorbsmore heat as the exhaust gas temperature rises, which reduces boiler efficien...Flue gas heat loss accounts for a significant component of theoverall heat loss for coal-fired boilers in power plants. The flue gas absorbsmore heat as the exhaust gas temperature rises, which reduces boiler efficiencyand raises coal consumption. Additionally, if the exhaust gas temperatureis too high, a lot of water must be used to cool the flue gas for the wetflue gas desulfurization system to function well, which has an impact onthe power plant’s ability to operate profitably. It is consequently vital totake steps to lower exhaust gas temperatures in order to increase boilerefficiency and decrease the amount of coal and water used. Desulfurizationperformance may be enhanced and water use can be decreased by reasonableflue gas characteristics at the entry. This study analyzed the unit’s energyconsumption, investment, and coal savings while proposing four couplingstrategies for regulating flue gas temperature and waste heat recovery. Agraded flue gas conditioning and waste heat recovery plan was presentedunder the condition of ensuring high desulfurization efficiency, along withthe notion of minimizing energy loss owing to energy inflow temperaturedifference. Numerical results show that the proposed methods improved thesystem performance and reduced the water consumption and regulated theboiler temperature.展开更多
This paper deals with the effect of microwave energy for mullite formation from placer sillimanite. A mullite formation is seen when 60 % SiC and 5% binder are used with the composite charge material, i.e. sillimanite...This paper deals with the effect of microwave energy for mullite formation from placer sillimanite. A mullite formation is seen when 60 % SiC and 5% binder are used with the composite charge material, i.e. sillimanite (60%) and Al2O3 (40%). The maximum temperature of the microwave sintering furnace achieved is 1355°C at 2450 W microwave power. Addition of 10 % binder to the same charge material with 60% SiC, the furnace temperature achieved is 1384°C at microwave power 1900 W. Mullite is formed within 25 minutes from the sillimanite, under the above experimental conditions. Whereas under the similar additive conditions, the mullite formed from sillimanite in conventional furnace heating, it took 3 hours at 1300°C. XRD data show the mullite phase for both the products obtained from microwave sintering furnace and conventional furnace. FESEM image analysis shows the mullite formations, SiC fibrous cluster and alumina needles in microwave treated sample. Thus microwave heat source is much more effective for value addition to red sediment placer sillimanite to form mullite in compare to conventional furnace.展开更多
我国北方地区的热电联产机组(combined heat and power,CHP)装机容量较大,在供暖期受“以热定电”约束产生大量碳排放。在CHP机组中加入碳捕集设备(carbon capture and storage,CCS)能减少其碳排放,但加剧了CHP机组的电、热耦合,因此,...我国北方地区的热电联产机组(combined heat and power,CHP)装机容量较大,在供暖期受“以热定电”约束产生大量碳排放。在CHP机组中加入碳捕集设备(carbon capture and storage,CCS)能减少其碳排放,但加剧了CHP机组的电、热耦合,因此,该文引入电锅炉及储热装置,为CCS辅助供热,针对含电锅炉辅助供热的CHP-CCS机组的电热系统低碳调度开展研究。首先研究具有储热CHP-CCS机组的运行特性模型,然后建立考虑碳交易成本的含CHP-CCS机组的电热系统低碳调度模型,其中采用模糊机会约束描述风电及负荷的不确定性。最后以改进的IEEE 30节点系统和西北地区某实际系统为算例,分析不同热源容量及置信水平对电热系统运行经济性、碳排放及弃风的作用,给出了电热系统日优化调度方案。展开更多
基金Supported by Key Scientific Research Projects of Sichuan Provincial Department of Technology (2010JY0165)Key Special Scientific Research Projects of Mianyang City of Sichuan Province (09Y003-13)Key Scientific Research Projects of Sichuan Provincial Department of Education (2003A112)
文摘The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the study through theoretical analysis and calculation showed that such a balanced energy mix is an economic way and efficient in saving energy and reducing air pollution, and elaborated the theoretical feasibility of popularizing such a heat supply mode in rural areas.
文摘A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the system had been examined. And the results also support theoretical feasibility of the system.
文摘Flue gas heat loss accounts for a significant component of theoverall heat loss for coal-fired boilers in power plants. The flue gas absorbsmore heat as the exhaust gas temperature rises, which reduces boiler efficiencyand raises coal consumption. Additionally, if the exhaust gas temperatureis too high, a lot of water must be used to cool the flue gas for the wetflue gas desulfurization system to function well, which has an impact onthe power plant’s ability to operate profitably. It is consequently vital totake steps to lower exhaust gas temperatures in order to increase boilerefficiency and decrease the amount of coal and water used. Desulfurizationperformance may be enhanced and water use can be decreased by reasonableflue gas characteristics at the entry. This study analyzed the unit’s energyconsumption, investment, and coal savings while proposing four couplingstrategies for regulating flue gas temperature and waste heat recovery. Agraded flue gas conditioning and waste heat recovery plan was presentedunder the condition of ensuring high desulfurization efficiency, along withthe notion of minimizing energy loss owing to energy inflow temperaturedifference. Numerical results show that the proposed methods improved thesystem performance and reduced the water consumption and regulated theboiler temperature.
文摘This paper deals with the effect of microwave energy for mullite formation from placer sillimanite. A mullite formation is seen when 60 % SiC and 5% binder are used with the composite charge material, i.e. sillimanite (60%) and Al2O3 (40%). The maximum temperature of the microwave sintering furnace achieved is 1355°C at 2450 W microwave power. Addition of 10 % binder to the same charge material with 60% SiC, the furnace temperature achieved is 1384°C at microwave power 1900 W. Mullite is formed within 25 minutes from the sillimanite, under the above experimental conditions. Whereas under the similar additive conditions, the mullite formed from sillimanite in conventional furnace heating, it took 3 hours at 1300°C. XRD data show the mullite phase for both the products obtained from microwave sintering furnace and conventional furnace. FESEM image analysis shows the mullite formations, SiC fibrous cluster and alumina needles in microwave treated sample. Thus microwave heat source is much more effective for value addition to red sediment placer sillimanite to form mullite in compare to conventional furnace.
文摘我国北方地区的热电联产机组(combined heat and power,CHP)装机容量较大,在供暖期受“以热定电”约束产生大量碳排放。在CHP机组中加入碳捕集设备(carbon capture and storage,CCS)能减少其碳排放,但加剧了CHP机组的电、热耦合,因此,该文引入电锅炉及储热装置,为CCS辅助供热,针对含电锅炉辅助供热的CHP-CCS机组的电热系统低碳调度开展研究。首先研究具有储热CHP-CCS机组的运行特性模型,然后建立考虑碳交易成本的含CHP-CCS机组的电热系统低碳调度模型,其中采用模糊机会约束描述风电及负荷的不确定性。最后以改进的IEEE 30节点系统和西北地区某实际系统为算例,分析不同热源容量及置信水平对电热系统运行经济性、碳排放及弃风的作用,给出了电热系统日优化调度方案。