Tetracycline selective electrode using molecularly imprinted polymer particles as quasi-ionophore was constructed the first time, and its performance was carefully characterized. Due to the specific recognition of tet...Tetracycline selective electrode using molecularly imprinted polymer particles as quasi-ionophore was constructed the first time, and its performance was carefully characterized. Due to the specific recognition of tetracycline by the particles, the selectivity coefficients for routine interferences were less than 10-4. Benefited from the absence of tetracycline in the sensitive membrane and the optimized composition of the inner filling solution, the limit of detection of the electrode was reduced to about 2.5 × 10^-8 mol/ L. It exhibited a good electrode slope 57.6 mV/decade near the theoretical Nernstian one, with a wide linear working range from 6.0 × 10^-8 to 1.0 × 10^-3 mol/L. The fabricated electrode should be used in pH 2--4, response time of which was less than 200 s when the concentration of tetracycline was higher than 1.0 × 10^-6 mol/L and no more than 30 min at the concentration of 1.0 × 10^-8 mol/L.展开更多
It is a problem to be solved that the experimental selectivity coefficients of ion selective electrodes (ISEs) depend on the activity. This paper studied the new method of determining selectivity coefficients. A mix...It is a problem to be solved that the experimental selectivity coefficients of ion selective electrodes (ISEs) depend on the activity. This paper studied the new method of determining selectivity coefficients. A mixed ion response equation, which was similar to Nicolsky-Eisenman (N-E) equation recommended by IUPAC, was proposed. The equation includes the practical response slope of ISEs to the primary ion and the interfering ion. The selectivity coefficient was defined by the equation instead of the N-E equation. The experimental part of the method is similar to that based on the N-E equation. The values of selectivity coefficients obtained with this method do not depend on the activity whether the electrodes exhibit the Nernst response or non-Nernst response. The feasibility of the new method is illustrated experimentally.展开更多
A new type of di benzoyl tartaric acid selective electr ode has been developed. Three double\| arm calixarene derivatives were emp loyed as the neutral ionophores. The poly(vinyl chloride) me...A new type of di benzoyl tartaric acid selective electr ode has been developed. Three double\| arm calixarene derivatives were emp loyed as the neutral ionophores. The poly(vinyl chloride) membrane electrode containing an amide derivative of ca lixarene as the neutral carrier an d a dibutyl phthalate as the plastici zer exhibited the highest sensitivity for dibenzoyl tartaric acid. The slop e of linear portion was 27.8 mV per c oncertration decade. The electrode has a fast response and a long lifetime .展开更多
Two novel heteroatom-bridged his (benzo-12-crown-4 ether)s, i.e. his [2-nitro-4,5 (1,4,7,10-tetraoxadecamethylene) disulfide 1 and diselenide 2, have been synthesized. X ray crystallographic structure was obtained for...Two novel heteroatom-bridged his (benzo-12-crown-4 ether)s, i.e. his [2-nitro-4,5 (1,4,7,10-tetraoxadecamethylene) disulfide 1 and diselenide 2, have been synthesized. X ray crystallographic structure was obtained for 1. Ion selective electrodes (ISE) for Ag+, containing 1 and 2 in PVC membrane as neutral carriers, were prepared, and their selectivity coefficients for Ag^+ (K_(Ag.M)^(pot)) were determined against other heavy metal ions, alkali and alkaline-earth metal ions. and ammonium ion. These ISEs showed excellent Ag^+ selectivities, log K_(Ag.M)^(pot) ≤ -3.8, against most of the interfering canons examined, except for Hg^+.展开更多
We developed an apparatus for producing high-density hydrogen plasma. The atomic hydrogen density was 3.1 × 1021 m<sup>?3</sup> at a pressure of 30 Pa, a microwave power of 1000 W, and a hydrogen gas ...We developed an apparatus for producing high-density hydrogen plasma. The atomic hydrogen density was 3.1 × 1021 m<sup>?3</sup> at a pressure of 30 Pa, a microwave power of 1000 W, and a hydrogen gas flow rate of 10 sccm. We confirmed that the temperatures of transition-metal films increased to above 800<sup>。</sup>C within 5 s when they were exposed to hydrogen plasma formed using the apparatus. We applied this phenomenon to the selective heat treatment of nickel films deposited on silicon wafers and formed nickel silicide electrodes. We found that this heat phenomenon automatically stopped after the nickel slicidation reaction finished. To utilize this method, we can perform the nickel silicidation process without heating the other areas such as channel regions and improve the reliability of silicon ultralarge-scale integration devices.展开更多
A method was proposed to determine boron trifluoride in boron trifluoride complex using fluoride ion selective electrode(ISE). Hydroxide was chosen to mask aluminum for the determination of 0.01—0.1 mol/L of fluoride...A method was proposed to determine boron trifluoride in boron trifluoride complex using fluoride ion selective electrode(ISE). Hydroxide was chosen to mask aluminum for the determination of 0.01—0.1 mol/L of fluoride. The simulation indicated that the permissible aluminum masked at a certain p H value was limited and hardly related to F-concentration and boric acid. It is better to control p H value below 11.5 and the aluminum concentration within 0.025 mol/L to minimize the interference of hydroxide to the fluoride ISE. The decomposition conditions of boron trifluoride by aluminum chloride were investigated. It is found that the F-detection ratio will approach 1.0 if the Al/F molar ratio is 0.3—0.7 and aluminum concentration is no more than 0.02 mol/L when heated at 80 ℃ for 10 min. In one word, hydroxide is quite fit to mask aluminum for samples which contain high content of fluoride and aluminum and the BF3 content can be successfully determined by this method.展开更多
Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effe...Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effect on the selectivity and sensitivity to Ag^+ ions.The electrode based on ionophore 9,10,20,25-tetrahydro-5H,12H-tribenzo[b,n,r][1,7,10,16,4,13]tetrathiadiaza cycloicosine 6,13-(7H,14H)-dione(C) with 2-nitrophenyl octyl ether(o-NPOE) as solvent in a poly(vinyl chloride)(PVC) membrane matrix sho...展开更多
CeO2 nanoparticles with an average diameter of about 30 nm were prepared by sol-gel method at lower temperature. The gel, transformed from the aqueous solution of metal nitrate and citric acid, can be combusted comple...CeO2 nanoparticles with an average diameter of about 30 nm were prepared by sol-gel method at lower temperature. The gel, transformed from the aqueous solution of metal nitrate and citric acid, can be combusted completely at lower temperature. The redox behavior and the crystallization process of the dried gel were studied by thermogravimetric analysis and infrared spectroscopy. The synthesized powders were characterized by X-ray powder diffraction and transmission electron microscopy. In addition, rare earth elements ion-selective electrodes based on acetyl cellulose were prepared using ultra fine cerium oxide powders.展开更多
A new ion-selective pH electrode of PVC membrane used formeasuring pH of the upper digestive tract is reported in this paper, which wasprepared with tri-n-octylamine or tris-(2-ehtylhexy)amine sensitive materials,and ...A new ion-selective pH electrode of PVC membrane used formeasuring pH of the upper digestive tract is reported in this paper, which wasprepared with tri-n-octylamine or tris-(2-ehtylhexy)amine sensitive materials,and polyvinylchloride (PVC) as a base. It was shown that the electrode has widelinearity (0.5-8, 3-12), good reproducibility, proper responsible time (【30s),longer life span (15 days). And the measurement was carried out in 50 cases bythe electrode.展开更多
Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ions react with the ion-selective electrode membrane,alterin...Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ions react with the ion-selective electrode membrane,altering the measured potential.Therefore,the characteristics of the effect of other ions on ammonium ion-selective electrode-based urea biosensors are considered.Based on the experimental results,the urea biosensor based on entrapment had a high response voltage of around 189 mV and fast response time of around 16 sec.Moreover,selectivity of the urea biosensor in different interfering ions was considered to elucidate the characteristics of ammonium ion-selective electrode-based biosensors.展开更多
Recently we have studied the rare earth ion-selective electrodes with active materials of the func-tional polymers and found that the process chosen for the functional polymers had an effect on the propertiesof gadoli...Recently we have studied the rare earth ion-selective electrodes with active materials of the func-tional polymers and found that the process chosen for the functional polymers had an effect on the propertiesof gadolinium ion selective electrode besides the effects of their structures.1.Effect of preparation process of the grafted polymers on the properties ofgadolinium ion selective electrodesThe electrode membranes which consist of functional polymers as active materials were prepared by re-action of gadolinium chloride with the radiation grafted clmer of acrlic acid and polystyrene of which展开更多
We put forward a method of rapid preparation of chloride selective electrode(Ag/AgCl electrode) by dipping silver wire into sodium hypochlorite solution. The electrodes were prepared through different immersion time...We put forward a method of rapid preparation of chloride selective electrode(Ag/AgCl electrode) by dipping silver wire into sodium hypochlorite solution. The electrodes were prepared through different immersion time. The properties of the electrodes, such as Nernst response, response time and longterm stability, were tested in simulated concrete pore solutions(SCPS). Moreover, the surface morphology of the electrodes was also detected after immersion in solutions over three months. The experimental results reveal that the Ag/AgCl electrode with the fabrication time of 20 minutes(E-20) which is recommended to work as the chloride ion selective electrode has the best performance. Compared to that fabricated by the electrolytic process(E-EP), E-20 can be manufactured in mass. The method has almost the same good performance of Nernst response as E-EP, and has a better response time which is less than 25 seconds. The method also shows a better good long-term stability in SCPS containing chloride ions over three months.展开更多
The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol...The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol) (A) were reported in this paper. The sensor was prepared by incorporating compound (A) into a plasticized polyvinyl chloride PVC membrane. The electrode reveals a Nernstian behavior over a wide iron ion concentration range (1.0 × 10-2 - 1.0 × 10-4 mol·L-1), and relatively low detection limit (1.0 × 10-5 mol·L-1). The potentiometric response was independent on the pH of the solution in the range of 4 - 7. The electrode showed a very short response time (<5 s). It exhibited very good selectivity relative to a wide variety of metal cations. Correlation of selectivity coefficient values with ionic radii of interferent cations was discussed. The proposed iron- ISE was applied for analysis of iron containing samples with comparison to a recommended spectrophotometric method.展开更多
This is the novel measurement of the apparent formation constants of trivalent lanthanide with humic substances by potentiometric titration using an ion selective electrode (ISE) consisting of bis(diphenylphosphoryl)m...This is the novel measurement of the apparent formation constants of trivalent lanthanide with humic substances by potentiometric titration using an ion selective electrode (ISE) consisting of bis(diphenylphosphoryl)methane as an ionophore. The ISE prepared exhibited a Nernstian response to the Eu3+ concentration in the test solutions in the presence of humic acid and fulvic acid. The effect of the solution conditions, including the pH, initial metal and humic substance concentrations, and ionic strength, on the formation constants was examined. The present formation constants were compared with the reported data using solvent extraction method.展开更多
Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health a...Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health and help in normal mineralization of bone and formation of dental enamel. The determination of fluoride in some species was performed by using fluoride ion-selective electrode by direct measurement and standard addition method. The concentration of fluoride ion was determined in drinking water (from different place at Kathmandu), toothpaste, various brand of tea and coffees. The range of fluoride concentration in water sample was 0.16 to 0.39 mg/l, tea and coffee samples were 0.011 to 0.084 mg/l and its value of toothpaste was 0.026 to 0.75 mg/l. The concentration of fluoride ion obtain from different sample was compared with the legitimate value given by the world health organization.展开更多
In this paper is reported a new method of determining serum albumin with potentiometry. The silver ion selective electrode was used as working electrode and S. C. E as reference electrode. By controlling the ionic s...In this paper is reported a new method of determining serum albumin with potentiometry. The silver ion selective electrode was used as working electrode and S. C. E as reference electrode. By controlling the ionic strength, PH and temperature constant, a good linear relationship was obtained between the cell potential and albumin concentration. This method .possessed characters-of operating simplicity, rapidity and directness. The samples could be detected directly and the results were in accordance with the values detected by classic K method.展开更多
The percent ammonia nitrogen was determined in Passaic River waste water using Ion-Selective Electrode EPA Method 350.3. The intelligent ammonia sensor integrates ammonia electrode, pH electrode and Ammonia Ion electr...The percent ammonia nitrogen was determined in Passaic River waste water using Ion-Selective Electrode EPA Method 350.3. The intelligent ammonia sensor integrates ammonia electrode, pH electrode and Ammonia Ion electrode together to realize the in situ detection of ammonia. The test results have shown that the sensor is easy operation, low cost and no pollution. The ammonia is determined potentiometrically using an ammonia ion selective electrode and a pH/mV meter, having an expanded millivolt scale. The ammonia selective electrode uses a hydrophobic gas-permeable membrane to separate the sample solution from an electrode internal solution of ammonium chloride. Dissolved ammonia is converted to NH<sub>3</sub> gas by raising the pH to above 11.0 with a strong base. NH<sub>3</sub> gas diffuses the membrane and changes the internal solution pH that is sensed by the electrode. In single laboratory test results have been found 1.001 NH<sub>3</sub>-/L and 0.897 mg NH<sub>3</sub>-N/L, recoveries were 77.3% and 83.1%, respectively.展开更多
In this paper,the functional polymeric active materials were prepared by the grafting copolymerization and their structure and properties were studied.The results show that the structure and properties of these ac- ti...In this paper,the functional polymeric active materials were prepared by the grafting copolymerization and their structure and properties were studied.The results show that the structure and properties of these ac- tive materials have the relative large effects on the properties of gadolinium ion selective electrodes.展开更多
Based on poly(vinyl chloride) membranes, a novel miniaturized screen-printed all-solid-state copper(II)-selective electrode has been developed for applications in environmental monitoring. Performance and applicabilit...Based on poly(vinyl chloride) membranes, a novel miniaturized screen-printed all-solid-state copper(II)-selective electrode has been developed for applications in environmental monitoring. Performance and applicability of the ion-selective electrode (ISE) have been proved by potentiometric investigations. Conducting polymers were used as intermediate layers and as solid contacts between the ion-selective membrane and the graphite transducer. The ion-complexing reagent 2-mercapto-benzoxazole was incorporated into poly(vinyl chloride) membranes. In the concentration range 10<sup>-6</sup> - 10<sup>-2</sup> mol/L, the ISE exhibited a linear Nernstian potential response to copper(II) with an average slope value of 28 mV/decade. The detection limit was 3 × 10<sup>-7</sup> mol/L. The electrode exhibits a short response time (<10 s) and can be used in the range of pH = 3 - 7. Selectivity coefficents against certain interfering ions are investigated. The life time of the electrode under laboratory conditions was approximately 12-month. The electrode was applied in the investigation of different aqueous environmental samples and the electrode characteristics were described. The copper(II) ASS electrode has also successfully been used in potentiometric, complexometric titrations with ethylenediaminetetraacetic acid.展开更多
A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet o...A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet of urea-formaldehyde resin containing Cl - ions to form a needle-shaped inner reference electrode, then the inner reference electrode was coated with a thin sheet of a PVC membrane containing an enoxacin tetraphenylborate ion-pair complex. The influences of various ion-pair complexes, concentrations of the active components in the membrane and the plasticizers on the performance of the electrode were studied by orthogonal design. The linear response range of the electrode was 7.9×10 -5 -1.0×10 -2 mol/L. The detection limit was 2.0×10 -5 mol/L. The slope was 30.4 mV/decade(25 ℃). The electrode can be used for the potentiometric determination of enoxacin tablets directly. The average recovery was 100.4%, and the RSD was 0.9%. The results agreed with those determined by the method in Chinese Pharmacopoeia.展开更多
基金Financial supports from Ningbo Science and Technology Bureau(No.2007C10061)Department of Education of Zhejiang Province(No.20070963)Science and Technology Department of Zhejiang Province of China(No. 2008R40G2070056) are gratefully acknowledged
文摘Tetracycline selective electrode using molecularly imprinted polymer particles as quasi-ionophore was constructed the first time, and its performance was carefully characterized. Due to the specific recognition of tetracycline by the particles, the selectivity coefficients for routine interferences were less than 10-4. Benefited from the absence of tetracycline in the sensitive membrane and the optimized composition of the inner filling solution, the limit of detection of the electrode was reduced to about 2.5 × 10^-8 mol/ L. It exhibited a good electrode slope 57.6 mV/decade near the theoretical Nernstian one, with a wide linear working range from 6.0 × 10^-8 to 1.0 × 10^-3 mol/L. The fabricated electrode should be used in pH 2--4, response time of which was less than 200 s when the concentration of tetracycline was higher than 1.0 × 10^-6 mol/L and no more than 30 min at the concentration of 1.0 × 10^-8 mol/L.
文摘It is a problem to be solved that the experimental selectivity coefficients of ion selective electrodes (ISEs) depend on the activity. This paper studied the new method of determining selectivity coefficients. A mixed ion response equation, which was similar to Nicolsky-Eisenman (N-E) equation recommended by IUPAC, was proposed. The equation includes the practical response slope of ISEs to the primary ion and the interfering ion. The selectivity coefficient was defined by the equation instead of the N-E equation. The experimental part of the method is similar to that based on the N-E equation. The values of selectivity coefficients obtained with this method do not depend on the activity whether the electrodes exhibit the Nernst response or non-Nernst response. The feasibility of the new method is illustrated experimentally.
文摘A new type of di benzoyl tartaric acid selective electr ode has been developed. Three double\| arm calixarene derivatives were emp loyed as the neutral ionophores. The poly(vinyl chloride) membrane electrode containing an amide derivative of ca lixarene as the neutral carrier an d a dibutyl phthalate as the plastici zer exhibited the highest sensitivity for dibenzoyl tartaric acid. The slop e of linear portion was 27.8 mV per c oncertration decade. The electrode has a fast response and a long lifetime .
文摘Two novel heteroatom-bridged his (benzo-12-crown-4 ether)s, i.e. his [2-nitro-4,5 (1,4,7,10-tetraoxadecamethylene) disulfide 1 and diselenide 2, have been synthesized. X ray crystallographic structure was obtained for 1. Ion selective electrodes (ISE) for Ag+, containing 1 and 2 in PVC membrane as neutral carriers, were prepared, and their selectivity coefficients for Ag^+ (K_(Ag.M)^(pot)) were determined against other heavy metal ions, alkali and alkaline-earth metal ions. and ammonium ion. These ISEs showed excellent Ag^+ selectivities, log K_(Ag.M)^(pot) ≤ -3.8, against most of the interfering canons examined, except for Hg^+.
文摘We developed an apparatus for producing high-density hydrogen plasma. The atomic hydrogen density was 3.1 × 1021 m<sup>?3</sup> at a pressure of 30 Pa, a microwave power of 1000 W, and a hydrogen gas flow rate of 10 sccm. We confirmed that the temperatures of transition-metal films increased to above 800<sup>。</sup>C within 5 s when they were exposed to hydrogen plasma formed using the apparatus. We applied this phenomenon to the selective heat treatment of nickel films deposited on silicon wafers and formed nickel silicide electrodes. We found that this heat phenomenon automatically stopped after the nickel slicidation reaction finished. To utilize this method, we can perform the nickel silicidation process without heating the other areas such as channel regions and improve the reliability of silicon ultralarge-scale integration devices.
基金Supported by the Independent Innovation Fund of Tianjin University(No.1307)
文摘A method was proposed to determine boron trifluoride in boron trifluoride complex using fluoride ion selective electrode(ISE). Hydroxide was chosen to mask aluminum for the determination of 0.01—0.1 mol/L of fluoride. The simulation indicated that the permissible aluminum masked at a certain p H value was limited and hardly related to F-concentration and boric acid. It is better to control p H value below 11.5 and the aluminum concentration within 0.025 mol/L to minimize the interference of hydroxide to the fluoride ISE. The decomposition conditions of boron trifluoride by aluminum chloride were investigated. It is found that the F-detection ratio will approach 1.0 if the Al/F molar ratio is 0.3—0.7 and aluminum concentration is no more than 0.02 mol/L when heated at 80 ℃ for 10 min. In one word, hydroxide is quite fit to mask aluminum for samples which contain high content of fluoride and aluminum and the BF3 content can be successfully determined by this method.
基金supported by the Chinese Academy of Sciences(No.KZCX2-YW-410)the National Natural Science Foundation of China(No.40776058)+1 种基金the National 863 High Technology Project of the Ministry of Science and Technology of China(No.2007AA09Z103)the Outstanding Youth Natural Science Foundation of Shandong Province(No.JQ200814)
文摘Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effect on the selectivity and sensitivity to Ag^+ ions.The electrode based on ionophore 9,10,20,25-tetrahydro-5H,12H-tribenzo[b,n,r][1,7,10,16,4,13]tetrathiadiaza cycloicosine 6,13-(7H,14H)-dione(C) with 2-nitrophenyl octyl ether(o-NPOE) as solvent in a poly(vinyl chloride)(PVC) membrane matrix sho...
基金The work was financially supported by the Project KJCXGC-O1 of Northwest Normal University, Lanzhou and theExcellent Young Te
文摘CeO2 nanoparticles with an average diameter of about 30 nm were prepared by sol-gel method at lower temperature. The gel, transformed from the aqueous solution of metal nitrate and citric acid, can be combusted completely at lower temperature. The redox behavior and the crystallization process of the dried gel were studied by thermogravimetric analysis and infrared spectroscopy. The synthesized powders were characterized by X-ray powder diffraction and transmission electron microscopy. In addition, rare earth elements ion-selective electrodes based on acetyl cellulose were prepared using ultra fine cerium oxide powders.
文摘A new ion-selective pH electrode of PVC membrane used formeasuring pH of the upper digestive tract is reported in this paper, which wasprepared with tri-n-octylamine or tris-(2-ehtylhexy)amine sensitive materials,and polyvinylchloride (PVC) as a base. It was shown that the electrode has widelinearity (0.5-8, 3-12), good reproducibility, proper responsible time (【30s),longer life span (15 days). And the measurement was carried out in 50 cases bythe electrode.
文摘Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ions react with the ion-selective electrode membrane,altering the measured potential.Therefore,the characteristics of the effect of other ions on ammonium ion-selective electrode-based urea biosensors are considered.Based on the experimental results,the urea biosensor based on entrapment had a high response voltage of around 189 mV and fast response time of around 16 sec.Moreover,selectivity of the urea biosensor in different interfering ions was considered to elucidate the characteristics of ammonium ion-selective electrode-based biosensors.
文摘Recently we have studied the rare earth ion-selective electrodes with active materials of the func-tional polymers and found that the process chosen for the functional polymers had an effect on the propertiesof gadolinium ion selective electrode besides the effects of their structures.1.Effect of preparation process of the grafted polymers on the properties ofgadolinium ion selective electrodesThe electrode membranes which consist of functional polymers as active materials were prepared by re-action of gadolinium chloride with the radiation grafted clmer of acrlic acid and polystyrene of which
基金the National Key Technology Research and Development Program of the Ministry of Science and Technology of China(2015BAB07B04)the Natural Science Foundation of China(51278167)the Fundamental Research Funds for the Central Universities(2016B04514)
文摘We put forward a method of rapid preparation of chloride selective electrode(Ag/AgCl electrode) by dipping silver wire into sodium hypochlorite solution. The electrodes were prepared through different immersion time. The properties of the electrodes, such as Nernst response, response time and longterm stability, were tested in simulated concrete pore solutions(SCPS). Moreover, the surface morphology of the electrodes was also detected after immersion in solutions over three months. The experimental results reveal that the Ag/AgCl electrode with the fabrication time of 20 minutes(E-20) which is recommended to work as the chloride ion selective electrode has the best performance. Compared to that fabricated by the electrolytic process(E-EP), E-20 can be manufactured in mass. The method has almost the same good performance of Nernst response as E-EP, and has a better response time which is less than 25 seconds. The method also shows a better good long-term stability in SCPS containing chloride ions over three months.
文摘The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol) (A) were reported in this paper. The sensor was prepared by incorporating compound (A) into a plasticized polyvinyl chloride PVC membrane. The electrode reveals a Nernstian behavior over a wide iron ion concentration range (1.0 × 10-2 - 1.0 × 10-4 mol·L-1), and relatively low detection limit (1.0 × 10-5 mol·L-1). The potentiometric response was independent on the pH of the solution in the range of 4 - 7. The electrode showed a very short response time (<5 s). It exhibited very good selectivity relative to a wide variety of metal cations. Correlation of selectivity coefficient values with ionic radii of interferent cations was discussed. The proposed iron- ISE was applied for analysis of iron containing samples with comparison to a recommended spectrophotometric method.
文摘This is the novel measurement of the apparent formation constants of trivalent lanthanide with humic substances by potentiometric titration using an ion selective electrode (ISE) consisting of bis(diphenylphosphoryl)methane as an ionophore. The ISE prepared exhibited a Nernstian response to the Eu3+ concentration in the test solutions in the presence of humic acid and fulvic acid. The effect of the solution conditions, including the pH, initial metal and humic substance concentrations, and ionic strength, on the formation constants was examined. The present formation constants were compared with the reported data using solvent extraction method.
文摘Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health and help in normal mineralization of bone and formation of dental enamel. The determination of fluoride in some species was performed by using fluoride ion-selective electrode by direct measurement and standard addition method. The concentration of fluoride ion was determined in drinking water (from different place at Kathmandu), toothpaste, various brand of tea and coffees. The range of fluoride concentration in water sample was 0.16 to 0.39 mg/l, tea and coffee samples were 0.011 to 0.084 mg/l and its value of toothpaste was 0.026 to 0.75 mg/l. The concentration of fluoride ion obtain from different sample was compared with the legitimate value given by the world health organization.
文摘In this paper is reported a new method of determining serum albumin with potentiometry. The silver ion selective electrode was used as working electrode and S. C. E as reference electrode. By controlling the ionic strength, PH and temperature constant, a good linear relationship was obtained between the cell potential and albumin concentration. This method .possessed characters-of operating simplicity, rapidity and directness. The samples could be detected directly and the results were in accordance with the values detected by classic K method.
文摘The percent ammonia nitrogen was determined in Passaic River waste water using Ion-Selective Electrode EPA Method 350.3. The intelligent ammonia sensor integrates ammonia electrode, pH electrode and Ammonia Ion electrode together to realize the in situ detection of ammonia. The test results have shown that the sensor is easy operation, low cost and no pollution. The ammonia is determined potentiometrically using an ammonia ion selective electrode and a pH/mV meter, having an expanded millivolt scale. The ammonia selective electrode uses a hydrophobic gas-permeable membrane to separate the sample solution from an electrode internal solution of ammonium chloride. Dissolved ammonia is converted to NH<sub>3</sub> gas by raising the pH to above 11.0 with a strong base. NH<sub>3</sub> gas diffuses the membrane and changes the internal solution pH that is sensed by the electrode. In single laboratory test results have been found 1.001 NH<sub>3</sub>-/L and 0.897 mg NH<sub>3</sub>-N/L, recoveries were 77.3% and 83.1%, respectively.
文摘In this paper,the functional polymeric active materials were prepared by the grafting copolymerization and their structure and properties were studied.The results show that the structure and properties of these ac- tive materials have the relative large effects on the properties of gadolinium ion selective electrodes.
文摘Based on poly(vinyl chloride) membranes, a novel miniaturized screen-printed all-solid-state copper(II)-selective electrode has been developed for applications in environmental monitoring. Performance and applicability of the ion-selective electrode (ISE) have been proved by potentiometric investigations. Conducting polymers were used as intermediate layers and as solid contacts between the ion-selective membrane and the graphite transducer. The ion-complexing reagent 2-mercapto-benzoxazole was incorporated into poly(vinyl chloride) membranes. In the concentration range 10<sup>-6</sup> - 10<sup>-2</sup> mol/L, the ISE exhibited a linear Nernstian potential response to copper(II) with an average slope value of 28 mV/decade. The detection limit was 3 × 10<sup>-7</sup> mol/L. The electrode exhibits a short response time (<10 s) and can be used in the range of pH = 3 - 7. Selectivity coefficents against certain interfering ions are investigated. The life time of the electrode under laboratory conditions was approximately 12-month. The electrode was applied in the investigation of different aqueous environmental samples and the electrode characteristics were described. The copper(II) ASS electrode has also successfully been used in potentiometric, complexometric titrations with ethylenediaminetetraacetic acid.
文摘A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet of urea-formaldehyde resin containing Cl - ions to form a needle-shaped inner reference electrode, then the inner reference electrode was coated with a thin sheet of a PVC membrane containing an enoxacin tetraphenylborate ion-pair complex. The influences of various ion-pair complexes, concentrations of the active components in the membrane and the plasticizers on the performance of the electrode were studied by orthogonal design. The linear response range of the electrode was 7.9×10 -5 -1.0×10 -2 mol/L. The detection limit was 2.0×10 -5 mol/L. The slope was 30.4 mV/decade(25 ℃). The electrode can be used for the potentiometric determination of enoxacin tablets directly. The average recovery was 100.4%, and the RSD was 0.9%. The results agreed with those determined by the method in Chinese Pharmacopoeia.