Nuclearmagnetic resonance imaging of breasts often presents complex backgrounds.Breast tumors exhibit varying sizes,uneven intensity,and indistinct boundaries.These characteristics can lead to challenges such as low a...Nuclearmagnetic resonance imaging of breasts often presents complex backgrounds.Breast tumors exhibit varying sizes,uneven intensity,and indistinct boundaries.These characteristics can lead to challenges such as low accuracy and incorrect segmentation during tumor segmentation.Thus,we propose a two-stage breast tumor segmentation method leveraging multi-scale features and boundary attention mechanisms.Initially,the breast region of interest is extracted to isolate the breast area from surrounding tissues and organs.Subsequently,we devise a fusion network incorporatingmulti-scale features and boundary attentionmechanisms for breast tumor segmentation.We incorporate multi-scale parallel dilated convolution modules into the network,enhancing its capability to segment tumors of various sizes through multi-scale convolution and novel fusion techniques.Additionally,attention and boundary detection modules are included to augment the network’s capacity to locate tumors by capturing nonlocal dependencies in both spatial and channel domains.Furthermore,a hybrid loss function with boundary weight is employed to address sample class imbalance issues and enhance the network’s boundary maintenance capability through additional loss.Themethod was evaluated using breast data from 207 patients at RuijinHospital,resulting in a 6.64%increase in Dice similarity coefficient compared to the benchmarkU-Net.Experimental results demonstrate the superiority of the method over other segmentation techniques,with fewer model parameters.展开更多
BACKGROUND Breast cancer is one of the most common malignant tumors in women worldwide and poses a severe threat to their health.Therefore,this study examined patients who underwent breast cancer surgery,analyzed hosp...BACKGROUND Breast cancer is one of the most common malignant tumors in women worldwide and poses a severe threat to their health.Therefore,this study examined patients who underwent breast cancer surgery,analyzed hospitalization costs and structure,and explored the impact of China Healthcare Security Diagnosis Related Groups(CHS-DRG)management on patient costs.It aimed to provide medical institutions with ways to reduce costs,optimize cost structures,reduce patient burden,and improve service efficiency.AIM To study the CHS-DRG payment system’s impact on breast cancer surgery costs.METHODS Using the CHS-DRG(version 1.1)grouping criteria,4073 patients,who underwent the radical resection of breast malignant tumors from January to December 2023,were included in the JA29 group;1028 patients were part of the CHS-DRG payment system,unlike the rest.Through an independent sample t-test,the length of hospital stay as well as total hospitalization,medicine and consumables,medical,nursing,medical technology,and management expenses were compared.Pearson’s correlation coefficient was used to test the cost correlation.RESULTS In terms of hospitalization expenses,patients in the CHS-DRG payment group had lower medical,nursing,and management expenses than those in the diagnosis-related group(DRG)non-payment group.For patients in the DRG payment group,the factors affecting the total hospitalization cost,in descending order of relevance,were medicine and consumable costs,consumable costs,medicine costs,medical costs,medical technology costs,management costs,nursing costs,and length of hospital stay.For patients in the DRG nonpayment group,the factors affecting the total hospitalization expenses in descending order of relevance were medicines and consumable expenses,consumable expenses,medical technology expenses,the cost of medicines,medical expenses,nursing expenses,length of hospital stay,and management expenses.CONCLUSION The CHS-DRG system can help control and reduce unnecessary medical expenses by controlling medicine costs,medical consumable costs,and the length of hospital stay while ensuring medical safety.展开更多
Computer vision is one of the significant trends in computer science.It plays as a vital role in many applications,especially in the medical field.Early detection and segmentation of different tumors is a big challeng...Computer vision is one of the significant trends in computer science.It plays as a vital role in many applications,especially in the medical field.Early detection and segmentation of different tumors is a big challenge in the medical world.The proposed framework uses ultrasound images from Kaggle,applying five diverse models to denoise the images,using the best possible noise-free image as input to the U-Net model for segmentation of the tumor,and then using the Convolution Neural Network(CNN)model to classify whether the tumor is benign,malignant,or normal.The main challenge faced by the framework in the segmentation is the speckle noise.It’s is a multiplicative and negative issue in breast ultrasound imaging,because of this noise,the image resolution and contrast become reduced,which affects the diagnostic value of this imaging modality.As result,speckle noise reduction is very vital for the segmentation process.The framework uses five models such as Generative Adversarial Denoising Network(DGAN-Net),Denoising U-Shaped Net(D-U-NET),Batch Renormalization U-Net(Br-UNET),Generative Adversarial Network(GAN),and Nonlocal Neutrosophic ofWiener Filtering(NLNWF)for reducing the speckle noise from the breast ultrasound images then choose the best image according to peak signal to noise ratio(PSNR)for each level of speckle-noise.The five used methods have been compared with classical filters such as Bilateral,Frost,Kuan,and Lee and they proved their efficiency according to PSNR in different levels of noise.The five diverse models are achieved PSNR results for speckle noise at level(0.1,0.25,0.5,0.75),(33.354,29.415,27.218,24.115),(31.424,28.353,27.246,24.244),(32.243,28.42,27.744,24.893),(31.234,28.212,26.983,23.234)and(33.013,29.491,28.556,25.011)forDGAN,Br-U-NET,D-U-NET,GANand NLNWF respectively.According to the value of PSNR and level of speckle noise,the best image passed for segmentation using U-Net and classification usingCNNto detect tumor type.The experiments proved the quality ofU-Net and CNN in segmentation and classification respectively,since they achieved 95.11 and 95.13 in segmentation and 95.55 and 95.67 in classification as dice score and accuracy respectively.展开更多
Background:As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues,a need has developed for reliable imaging phantoms for use in system design and component calibration.In advan...Background:As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues,a need has developed for reliable imaging phantoms for use in system design and component calibration.In advanced imaging modalities such as refraction-based methods,it is critical that developed phantoms capture the biological details seen in clinical precancerous and cancerous cases while minimizing artifacts that may be caused due to phantom production.This work presents the fabrication of a breast tissue imaging phantom from cadaveric breast tissue suitable for use in both transmission and refraction-enhanced imaging systems.Methods:Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into the fixed tissue while maintaining the native tumor/adipose tissue interface.Results:The resulting human–murine tissue hybrid phantom was mounted on a clear acrylic housing for absorption and refraction X-ray imaging.Digital breast tomosynthesis was also performed.Conclusion:Both attenuation-based imaging and refraction-based imaging of the phantom are presented to confirm the suitability of this phantom's use in both imaging modalities.展开更多
Deep neural network(DNN)based computer-aided breast tumor diagnosis(CABTD)method plays a vital role in the early detection and diagnosis of breast tumors.However,a Brightness mode(B-mode)ultrasound image derives train...Deep neural network(DNN)based computer-aided breast tumor diagnosis(CABTD)method plays a vital role in the early detection and diagnosis of breast tumors.However,a Brightness mode(B-mode)ultrasound image derives training feature samples that make closer isolation toward the infection part.Hence,it is expensive due to a metaheuristic search of features occupying the global region of interest(ROI)structures of input images.Thus,it may lead to the high computational complexity of the pre-trained DNN-based CABTD method.This paper proposes a novel ensemble pretrained DNN-based CABTD method using global-and local-ROI-structures of B-mode ultrasound images.It conveys the additional consideration of a local-ROI-structures for further enhan-cing the pretrained DNN-based CABTD method’s breast tumor diagnostic performance without degrading its visual quality.The features are extracted at various depths(18,50,and 101)from the global and local ROI structures and feed to support vector machine for better classification.From the experimental results,it has been observed that the combined local and global ROI structure of small depth residual network ResNet18(0.8 in%)has produced significant improve-ment in pixel ratio as compared to ResNet50(0.5 in%)and ResNet101(0.3 in%),respectively.Subsequently,the pretrained DNN-based CABTD methods have been tested by influencing local and global ROI structures to diagnose two specific breast tumors(Benign and Malignant)and improve the diagnostic accuracy(86%)compared to Dense Net,Alex Net,VGG Net,and Google Net.Moreover,it reduces the computational complexity due to the small depth residual network ResNet18,respectively.展开更多
The present work proposed a simple model for breast cancer hyperthermia treatment at 2.45 GHz. The proposed model involves nine-element antennas alongside a numerical breast comprising multiple tumors. Using a coupled...The present work proposed a simple model for breast cancer hyperthermia treatment at 2.45 GHz. The proposed model involves nine-element antennas alongside a numerical breast comprising multiple tumors. Using a coupled EM-Thermal simulation in the CST suite, the simulated results for a single antenna showed a reflection coefficient (S<sub>11</sub>) better than -47 dB and demonstrated a bandwidth of 78 MHz. The specific absorption rate (SAR) as a function of input powers was examined inside the breast tissues, where it exhibited a promising performance higher than 3 W/kg at the tumor volume when the applied power was at a reasonable level of 1.5 W whereas it was well attained under the recommend IEEE level of 1.6 W/kg through the surrounded health tissues. Taking into consideration nine-element antennas covering the breast containing two different located tumors, the maximum temperature as a function of treatment time was presented at which a resulting temperature of 43°C was obtainable within 10 minutes, favored for hyperthermia purposes. Considering the maximum power level of 1.5 W, the potential use of applying three-element antennas, simultaneously with 0.5 W, could be achieved.展开更多
A 49-year-old woman was referred to the Department of Plastic and Breast Surgery under suspicion of breast cancer after a mammogram revealed a self-discovered tumor in the lower part of her left breast. Clinical exami...A 49-year-old woman was referred to the Department of Plastic and Breast Surgery under suspicion of breast cancer after a mammogram revealed a self-discovered tumor in the lower part of her left breast. Clinical examination, mammography, and histopathological examination revealed that the original tumor in the left breast was benign, and an incidental malignant tumor, a dermatofibrosarcoma protuberans (DFSP), was found in the contralateral breast. DFSP is a rare and highly malignant entity that is often silent and difficult to diagnose, making a biopsy essential. Surgical treatment must be aggressive due to the high risk of recurrence, which constitutes a technical challenge. The patient underwent surgery using an oncoplastic approach with a volume-reducing technique to achieve the best possible therapeutic and aesthetic results. Therapeutic breast reduction was performed on the right breast and the tumor was removed within the resected tissue. A contralateral symmetrizing mammoplasty was also performed simultaneously. The patient was discharged without major complications, and no recurrence of the tumor was seen during the 30-month follow-up period. The surgical approach included alternative solutions in addition to conventional lumpectomy or mastectomy. A multidisciplinary, open-minded, and creative approach resulted in a satisfying outcome for this patient.展开更多
A novel approach to image hemoglobin concentration(△Dhb) and oxygen saturation (△Doxy) of breast tissue is presented. The scenograph of dual-wavelength (760 and 850 nm) near infrared lights through breast tiss...A novel approach to image hemoglobin concentration(△Dhb) and oxygen saturation (△Doxy) of breast tissue is presented. The scenograph of dual-wavelength (760 and 850 nm) near infrared lights through breast tissue is acquired by high sensitive charge coupled device (CCD) camera. The evaluation criterion of the difference of △Dhh and △Doxy between detected and referenced breast tissue can be obtained by a calculation formula without complicate caculation. This approach is applied to clinic detection in breast tissue. The ongoing clinical experiments indicate that malignant tumor usually exhibits characterize of "higher △Dhb and lower △Doxy", while benign lesion often shows "lower △Dhb and higher △Doxy" or other characters. So it is useful to assist the diagnosis of breast disease.展开更多
BACKGROUND The diagnostic specificity of conventional ultrasound for breast non-mass lesions(NMLs)is low at approximately 21%-43%.Shear wave elastography(SWE)can distinguish benign from malignant lesions by evaluating...BACKGROUND The diagnostic specificity of conventional ultrasound for breast non-mass lesions(NMLs)is low at approximately 21%-43%.Shear wave elastography(SWE)can distinguish benign from malignant lesions by evaluating the internal and peripheral stiffness.SWE has good reproducibility and high diagnostic efficacy.However,there are very few independent studies on the diagnostic value of SWE in breast NMLs.AIM To determine the value of SWE in the differential diagnosis of breast NMLs.METHODS This study enrolled a total of 118 patients with breast NMLs who underwent SWE examinations in the Beijing Shijitan Hospital Affiliated to Capital Medical University and The Second Hospital of Shandong University from January 2019 to January 2020.The internal elastic parameters of the lesions were recorded,including maximum(Emax),mean(Emean)and minimum elastic values and the standard deviation.The following peripheral parameters were noted:Presence of a“stiff rim”sign;Emax,and Emean elasticity values within 1 mm,1.5 mm,2 mm,2.5 mm and 3 mm from the edge of NMLs.The receiver operating characteristic curve of each parameter was drawn,and the areas under the curve were calculated.RESULTS Emax,Emean and elastic values,and the standard deviation of the internal elastic values in malignant NMLs were significantly higher than those in benign NMLs(P<0.05).The percentage with the“stiff rim”sign in malignant NMLs was significantly higher than that in the benign group(P<0.05),and Emax and Emean at the shell of 1 mm,1.5 mm,2 mm,2.5 mm and 3 mm in the malignant group were all higher than those in the benign group(P<0.05).Of the surrounding elasticity values,Emax of the shell at 2.5 mm in malignant NMLs had maximum areas under the curve of 0.900,and the corresponding sensitivity and specificity were 94.57%and 85.86%,respectively.CONCLUSION The“stiff rim”sign and multiple quantitative elastic values within and around the lesion had good diagnostic performance in the differential diagnosis of breast NMLs.Emax in peripheral tissue had better diagnostic efficiency than other parameters.展开更多
BACKGROUND Breast non-mass-like lesions(NMLs)account for 9.2%of all breast lesions.The specificity of the ultrasound diagnosis of NMLs is low,and it cannot be objectively classified according to the 5th Edition of the...BACKGROUND Breast non-mass-like lesions(NMLs)account for 9.2%of all breast lesions.The specificity of the ultrasound diagnosis of NMLs is low,and it cannot be objectively classified according to the 5th Edition of the Breast Imaging Reporting and Data System(BI-RADS).Contrast-enhanced ultrasound(CEUS)can help to differentiate and classify breast lesions but there are few studies on NMLs alone.AIM To analyze the features of benign and malignant breast NMLs in grayscale ultrasonography(US),color Doppler flow imaging(CDFI)and CEUS,and to explore the efficacy of the combined diagnosis of NMLs and the effect of CEUS on the BI-RADS classification of NMLs.METHODS A total of 51 breast NMLs verified by pathology were analyzed in our hospital from January 2017 to April 2019.All lesions were examined by US,CDFI and CEUS,and their features from those examinations were analyzed.With pathology as the gold standard,binary logic regression was used to analyze the independent risk factors for malignant breast NMLs,and a regression equation was established to calculate the efficiency of combined diagnosis.Based on the regression equation,the combined diagnostic efficiency of US combined with CEUS(US+CEUS)was determined.The initial BI-RADS-US classification of NMLs was adjusted according to the independent risk factors identified by CEUS,and the diagnostic efficiency of CEUS combined with BI-RADS(CEUS+BI-RADS)was calculated based on the results.ROC curves were drawn to compare the diagnostic values of the three methods,including US,US+CEUS,and CEUS+BI-RADS,for benign and malignant NMLs.RESULTS Microcalcification,enhancement time,enhancement intensity,lesion scope,and peripheral blood vessels were significantly different between benign and malignant NMLs.Among these features,microcalcification,higher enhancement,and lesion scope were identified as independent risk factors for malignant breast NMLs.When US,US+CEUS,and CEUS+BI-RADS were used to identify the benign and malignant breast NMLs,their sensitivity rates were 82.6%,91.3%,and 87.0%,respectively;their specificity rates were 71.4%,89.2%,and 92.9%,respectively;their positive predictive values were 70.4%,87.5%,and 90.9%,respectively;their negative predictive values were 83.3%,92.6%,and 89.7%,respectively;their accuracy rates were 76.5%,90.2%,and 90.2%,respectively;and their corresponding areas under ROC curves were 0.752,0.877 and 0.903,respectively.Z tests showed that the area under the ROC curve of US was statistically smaller than that of US+CEUS and CEUS+BI-RADS,and there was no statistical difference between US+CEUS and CEUS+BI-RADS.CONCLUSION US combined with CEUS can improve diagnostic efficiency for NMLs.The adjustment of the BI-RADS classification according to the features of contrastenhanced US of NMLs enables the diagnostic results to be simple and intuitive,facilitates the management of NMLs,and effectively reduces the incidence of unnecessary biopsy.展开更多
BACKGROUND The incidence rate of breast cancer has exceeded that of lung cancer,and it has become the most malignant type of cancer in the world.BI-RADS 4 breast nodules have a wide range of malignant risks and are as...BACKGROUND The incidence rate of breast cancer has exceeded that of lung cancer,and it has become the most malignant type of cancer in the world.BI-RADS 4 breast nodules have a wide range of malignant risks and are associated with challenging clinical decision-making.AIM To explore the diagnostic value of artificial intelligence(AI)automatic detection systems for BI-RADS 4 breast nodules and to assess whether conventional ultrasound BI-RADS classification with AI automatic detection systems can reduce the probability of BI-RADS 4 biopsy.METHODS A total of 107 BI-RADS breast nodules confirmed by pathology were selected between June 2019 and July 2020 at Hwa Mei Hospital,University of Chinese Academy of Sciences.These nodules were classified by ultrasound doctors and the AI-SONIC breast system.The diagnostic values of conventional ultrasound,the AI automatic detection system,conventional ultrasound combined with the AI automatic detection system and adjusted BI-RADS classification diagnosis were statistically analyzed.RESULTS Among the 107 breast nodules,61 were benign(57.01%),and 46 were malignant(42.99%).The pathology results were considered the gold standard;furthermore,the sensitivity,specificity,accuracy,Youden index,and positive and negative predictive values were 84.78%,67.21%,74.77%,0.5199,66.10%and 85.42%for conventional ultrasound BI-RADS classification diagnosis,86.96%,75.41%,80.37%,0.6237,72.73%,and 88.46%for automatic AI detection,80.43%,90.16%,85.98%,0.7059,86.05%,and 85.94%for conventional ultrasound BI-RADS classification with automatic AI detection and 93.48%,67.21%,78.50%,0.6069,68.25%,and 93.18%for adjusted BI-RADS classification,respectively.The biopsy rate,cancer detection rate and malignancy risk were 100%,42.99%and 0%and 67.29%,61.11%,and 1.87%before and after BI-RADS adjustment,respectively.CONCLUSION Automatic AI detection has high accuracy in determining benign and malignant BI-RADS 4 breast nodules.Conventional ultrasound BI-RADS classification combined with AI automatic detection can reduce the biopsy rate of BI-RADS 4 breast nodules.展开更多
Over-expression of Fas ligand (FasL) on tumor cell surface can induce the apoptosis of spe- cific activated tumor infiltrating lymphocytes (TILs) via the Fas/FasL pathway, leading to the formation of a site of imm...Over-expression of Fas ligand (FasL) on tumor cell surface can induce the apoptosis of spe- cific activated tumor infiltrating lymphocytes (TILs) via the Fas/FasL pathway, leading to the formation of a site of immune privilege surrounding the tumor mass for escaping immune surveillance and pro- moting tumor proliferation, invasion and metastasis. The blocking effect of miR-21 on FasL-mediated apoptosis in breast cancers was investigated in this study. The expression levels of miR-21 and FasL in human breast carcinoma cell lines were detected by using RT-PCR and Western blotting. FasL as a tar- get gene of miR-21 was identified by Luciferase assay. The apoptosis of Jurkat T lymphocytes induced by MCF-7 cells was determined by flow cytometry. It was found that in four human breast cancer cell lines, FasL expression level in MCF-7 cells was the highest, while miR-21 was down-regulated the most notably. After miR-21 expression in MCF-7 cells was up-regulated, FasL was identified as a target gene of miR-21. When the effector/target (E/T) ratio of MCF-7 cells and Jurkat cells was 10:1, 5:1 and 1:1, the inhibitory rate of apoptosis of Jurkat T lymphocytes induced by MCF-7 cells was 95.81%, 93.16% and 91.94%, respectively. It is suggested that in breast cancers miR-21 expression is negatively associ- ated with FasL expression, and FasL is a target gene of miR-21, miR-21 targeting and regulating FasL-mediated apoptosis will bring us the possibility of a new tumor immunotherapy via breaking tu- mor immune privilege.展开更多
Objective:To study the diagnostic value of T2*-weighted first-pass perfusion imaging in breast tumors.Methods: We analyzed the magnetic resonance imaging(MRI)information along with the pathological and immunohistochem...Objective:To study the diagnostic value of T2*-weighted first-pass perfusion imaging in breast tumors.Methods: We analyzed the magnetic resonance imaging(MRI)information along with the pathological and immunohistochemistry re- sults.Magnetic resonance imaging was performed in 28 patients with breast tumor.The time to signal intensity curves were generated according to the T2*-weighted first-pass perfusion imaging.The curve’s maximal signal intensity drop rate and maximal signal intensity decrease time were analyzed and compared with the pathological diagnoses after surgery.Results: Malignant breast lesions showed higher maximal signal intensity drop rate(44.69%±17.07 vs.17.22%±7.49,P<0.001) than benign lesions,but there was no significant difference of maximal signal decrease time between those two lesions(23.94 s±4.92 vs.20.02 s±6.83,P>0.05).Conclusion:The T2*-weighted first-pass perfusion imaging has enough sensitivity and specificity in breast tumor diagnosis.展开更多
BACKGROUND Adenomyoepithelioma(AME)of the breast is a rare type of benign breast tumor.Many AMEs show benign behavior,but reports of the malignant type are rare.We present the case of a patient with AME with repeated ...BACKGROUND Adenomyoepithelioma(AME)of the breast is a rare type of benign breast tumor.Many AMEs show benign behavior,but reports of the malignant type are rare.We present the case of a patient with AME with repeated local recurrences and further malignant transformation.CASE SUMMARY A 53-year-old woman visited our hospital with a 16-mm palpable mass in the right breast.A core needle biopsy was performed.The pathological diagnosis was AME.Lumpectomy with a safety margin was performed without axillary lymph node dissection(ALND).Two years later,local recurrence developed,and the patient again underwent lumpectomy with a safety margin.The pathology showed malignant AME,and the margin was negative.Eight months later,local recurrence developed again in the same location,and a total mastectomy was performed without ALND.The pathological diagnosis was malignant AME.The patient was disease-free for three years posttreatment.CONCLUSION The treatment of AME requires caution,as it may exhibit repeated recurrences after local excision as well as malignant transformation.展开更多
BACKGROUND Patients with an in-breast tumor recurrence(IBTR)after breast-conserving therapy have a high risk of distant metastasis and disease-related mortality.Classifying clinical parameters that increase risk for r...BACKGROUND Patients with an in-breast tumor recurrence(IBTR)after breast-conserving therapy have a high risk of distant metastasis and disease-related mortality.Classifying clinical parameters that increase risk for recurrence after IBTR remains a challenge.AIM To describe primary and recurrent tumor characteristics in patients who experience an IBTR and understand the relationship between these characteristics and disease outcomes.METHODS Patients with stage 0-II breast cancer treated with lumpectomy and adjuvant radiation were identified from institutional databases of patients treated from 2003-2017 at our institution.Overall survival(OS),disease-free survival,and local recurrence-free survival(LRFS)were estimated using the Kaplan Meier method.We identified patients who experienced an isolated IBTR.Concordance of hormone receptor status and location of tumor from primary to recurrence was evaluated.The effect of clinical and treatment parameters on disease outcomes was also evaluated.RESULTS We identified 2164 patients who met the eligibility criteria.The median follow-up for all patients was 3.73[interquartile range(IQR)2.27-6.07]years.Five-year OS was 97.7%(95%CI:96.8%-98.6%)with 28 deaths;5-year LRFS was 98.0%(97.2-98.8)with 31 IBTRs.We identified 37 patients with isolated IBTR,19(51.4%)as ductal carcinoma in situ and 18(48.6%)as invasive disease,of whom 83.3%had an in situ component.Median time from initial diagnosis to IBTR was 1.97(IQR:1.03-3.5)years.Radiotherapy information was available for 30 of 37 patients.Median whole-breast dose was 40.5 Gy and 23 patients received a boost to the tumor bed.Twenty-five of thirty-two(78.1%)patients had concordant hormone receptor status,HER-2 receptor status,and estrogen receptor(ER)(P=0.006)and progesterone receptor(PR)(P=0.001)status from primary to IBTR were significantly associated.There were no observed changes in HER-2 status from primary to IBTR.The concordance between quadrant of primary to IBTR was 10/19[(62.2%),P=0.008].Tumor size greater than 1.5 cm(HR=0.44,95%CI:0.22-0.90,P=0.02)and use of endocrine therapy upfront(HR=0.36,95%CI:0.18-0.73,P=0.004)decreased the risk of IBTR.CONCLUSION Among patients with early stage breast cancer who had breast conserving surgery treated with adjuvant RT,ER/PR status and quadrant were highly concordant from primary to IBTR.Tumor size greater than 1.5 cm and use of adjuvant endocrine therapy were significantly associated with decreased risk of IBTR.展开更多
BREAST fibromatosis is a rare kind of lesion. The average incidence is about 2-4 per million every year} So far there have been about 100 cases reported altogether.2 In this report, we describe a case of breast fibrom...BREAST fibromatosis is a rare kind of lesion. The average incidence is about 2-4 per million every year} So far there have been about 100 cases reported altogether.2 In this report, we describe a case of breast fibromatosis developed after hydrophilic polyacrylamide gel (HPG) injection for breast augmentation. By reviewing the literature, the possible pathogenesis of this case and the proper treatment strategy are investigated.展开更多
Mechanical microenvironment can strongly affect the metastatic efficiency of circulating tumor cells.However,the effect of suspension state on their extravasation and the mechanisms involved are still unclear.To explo...Mechanical microenvironment can strongly affect the metastatic efficiency of circulating tumor cells.However,the effect of suspension state on their extravasation and the mechanisms involved are still unclear.To explore the influence of suspension state on extravasation(including adhesion,spreading and transendothelial migration)of breast tumor cells and its relevant molecular mechanism,MDA-MB-231 cells were cultured on poly(2-hydroxyethyl methacrylate)coated 6-well plates to minic the suspension state.Suspension state promoted adhesion,spreading and transendothelial migration of MDA-MB-231 cells to EAhy926 endothelial cells(ECs)monolayer under both the static condition and 0.5 dyne/cm^(2) flow shear stress(FSS).The number of cells adhered to ECs monolayer reached 2.15(static condition,3 d)and 1.67(FSS,3 d)times,and the number of migration reached 10.60 times,respectively,as compared to that in adhesion state.Moreover,MDA-MB-231 cells knockdown of integrin β1 provoked poor adhesion and transendothelial migration,as compared with MDA-MB-231 cells.But it made no difference in cell spreading.Our results implied the increasing expression of integrin β1 induced by suspension culture promoted the adhesion and transendothelial migration of MDA-MB-231 cells,but had no significant influence on their spreading.展开更多
Objective: To investigate the expression of cyclin E in breast cancer tissues and its relationship with prognosis of the patients with breast cancer. Methods: The expression of cyclin E, HER-2/neu, nm23-H1 and actin...Objective: To investigate the expression of cyclin E in breast cancer tissues and its relationship with prognosis of the patients with breast cancer. Methods: The expression of cyclin E, HER-2/neu, nm23-H1 and actin was detected in 80 breast cancer tissues and 18 benign breast tumor tissues by immunohistochemical methods. The relationship between cyclin E and the remaining genes or the clinical data of the patients with breast cancer was analyzed. Results: The over expression rate of cyclin E in malignant tissues was obviously higher than that in benign tumor tissues (P〈0.01). The over expression of cyclin E in later stage of disease was higher than that in early stage of disease (P〈0.05). The expression of cyclin E in ER positive tissues was lower than that in ER negative tissues (P〈0.05). The expression of cyclin E in PR positive tissues and PR negative tissues had no significant difference (P〉0.05). The expression of cyclin E in HER-2/neu positive tissues was higher than that in HER-2/neu negative tissues (P〈0.05). And the expression of cyclin E in ER, PR and HER-2/neu all positive tissues was much higher (P〈0.01). There was no significant difference in the expression of cyclin E between nm23-H1 positive tissues and nm23-H1 negative tissues (P〉0.05). The expression of cyclin E in actin positive and continuous distribution tissues was lower than that in actin negative or discontinuous distribution tissues (P〈0.05). Conclusion: The expression of cyclin E has a strong correlation to the prognosis of the patients with breast cancer.展开更多
OBJECTIVE GubenyiliuⅡ(GYⅡ),a traditional Chinese medicine(TCM)formula used in our hospital,has shown beneficial effects in cancer patients.In this study,we investigated the molecular mechanisms underlying the benefi...OBJECTIVE GubenyiliuⅡ(GYⅡ),a traditional Chinese medicine(TCM)formula used in our hospital,has shown beneficial effects in cancer patients.In this study,we investigated the molecular mechanisms underlying the beneficial effects of GYⅡon murine breast cancer models.METHODS Inhibition of tumor growth and metastasis was evaluated by assessment of tumor weight and analysis of bioluminescent signal after a homograft inoculation.Viability of cultured breast cancer cells was determined using MTT assay andreal-time cell analysis(RTCA).Cell migratory ability was evaluated by Transwell?assay and wound healing assay.Subsequently,the potential anti-tumor and anti-metastatic mechanism was investigated by Western blotting and Immunohistochemistry.RESULTS GYⅡshowed significant inhibitory effects on tumor growth and metastasis in the murine breast cancer model.And GYⅡsuppressed theproliferation of 4T1 and MCF-7 cells in a dose-dependent manner.A better inhibitory effect on 4T1 cells proliferation and migration was found in sub-fractions(SF)of GYⅡ.Moreover,heparanase expression and degree of angiogenesis were reduced in tumor tissues.Western blotting analysis showed decreased expression of heparanase and growth factors in the cells treated with GYⅡand its sub-fractions(SF2 and SF3),there by a reduction in phosphorylation of ERK and AKT.CONCLUSION GYⅡexerts anti-tumor growth and anti-metastatic effects on murine breast cancer model.Sub-fractions 2 and 3 exhibits higher potency of the anti-tumor activity that is,at least partly,associated with decreased heparanase and growth factor sexpression,which subsequently sup-pressed activation of ERK and AKT pathways.展开更多
A number of studies have been shown that retiniods can inhibit malignant cell growth including certain breast carcinoma cells. Its inhibitory effort is observed only in ER-positive but not in ER-negative breast cancer...A number of studies have been shown that retiniods can inhibit malignant cell growth including certain breast carcinoma cells. Its inhibitory effort is observed only in ER-positive but not in ER-negative breast cancer cells. We examined retinoic acid receptors (RARs) and retinoids X receptors (RXRs) levels in 6 breast carcinoma cell lines and 18 breast cancer biopsy specimens. We found that RAR-α mRNA level was significantly higher in ER positive cell lines and samples. RAR-γ mRNA was expressed at relatively high levels in majority of tumor samples independent of the ER-status while RAR-β mRNA was expressed at low levels. We also found high RXR-α mRNA levels in all of the tumor samples examined while RXR-γ mRNA could not be detected. Our study suggests a possibility that retinoids inhibit tumor cell growth through RAR-a and RAR-α levels may serve as a potential marker to determine responsiveness of patients to retinoids therapy.展开更多
基金funded by the National Natural Foundation of China under Grant No.61172167the Science Fund Project of Heilongjiang Province(LH2020F035).
文摘Nuclearmagnetic resonance imaging of breasts often presents complex backgrounds.Breast tumors exhibit varying sizes,uneven intensity,and indistinct boundaries.These characteristics can lead to challenges such as low accuracy and incorrect segmentation during tumor segmentation.Thus,we propose a two-stage breast tumor segmentation method leveraging multi-scale features and boundary attention mechanisms.Initially,the breast region of interest is extracted to isolate the breast area from surrounding tissues and organs.Subsequently,we devise a fusion network incorporatingmulti-scale features and boundary attentionmechanisms for breast tumor segmentation.We incorporate multi-scale parallel dilated convolution modules into the network,enhancing its capability to segment tumors of various sizes through multi-scale convolution and novel fusion techniques.Additionally,attention and boundary detection modules are included to augment the network’s capacity to locate tumors by capturing nonlocal dependencies in both spatial and channel domains.Furthermore,a hybrid loss function with boundary weight is employed to address sample class imbalance issues and enhance the network’s boundary maintenance capability through additional loss.Themethod was evaluated using breast data from 207 patients at RuijinHospital,resulting in a 6.64%increase in Dice similarity coefficient compared to the benchmarkU-Net.Experimental results demonstrate the superiority of the method over other segmentation techniques,with fewer model parameters.
基金Research Center for Capital Health Management and Policy,No.2024JD09.
文摘BACKGROUND Breast cancer is one of the most common malignant tumors in women worldwide and poses a severe threat to their health.Therefore,this study examined patients who underwent breast cancer surgery,analyzed hospitalization costs and structure,and explored the impact of China Healthcare Security Diagnosis Related Groups(CHS-DRG)management on patient costs.It aimed to provide medical institutions with ways to reduce costs,optimize cost structures,reduce patient burden,and improve service efficiency.AIM To study the CHS-DRG payment system’s impact on breast cancer surgery costs.METHODS Using the CHS-DRG(version 1.1)grouping criteria,4073 patients,who underwent the radical resection of breast malignant tumors from January to December 2023,were included in the JA29 group;1028 patients were part of the CHS-DRG payment system,unlike the rest.Through an independent sample t-test,the length of hospital stay as well as total hospitalization,medicine and consumables,medical,nursing,medical technology,and management expenses were compared.Pearson’s correlation coefficient was used to test the cost correlation.RESULTS In terms of hospitalization expenses,patients in the CHS-DRG payment group had lower medical,nursing,and management expenses than those in the diagnosis-related group(DRG)non-payment group.For patients in the DRG payment group,the factors affecting the total hospitalization cost,in descending order of relevance,were medicine and consumable costs,consumable costs,medicine costs,medical costs,medical technology costs,management costs,nursing costs,and length of hospital stay.For patients in the DRG nonpayment group,the factors affecting the total hospitalization expenses in descending order of relevance were medicines and consumable expenses,consumable expenses,medical technology expenses,the cost of medicines,medical expenses,nursing expenses,length of hospital stay,and management expenses.CONCLUSION The CHS-DRG system can help control and reduce unnecessary medical expenses by controlling medicine costs,medical consumable costs,and the length of hospital stay while ensuring medical safety.
文摘Computer vision is one of the significant trends in computer science.It plays as a vital role in many applications,especially in the medical field.Early detection and segmentation of different tumors is a big challenge in the medical world.The proposed framework uses ultrasound images from Kaggle,applying five diverse models to denoise the images,using the best possible noise-free image as input to the U-Net model for segmentation of the tumor,and then using the Convolution Neural Network(CNN)model to classify whether the tumor is benign,malignant,or normal.The main challenge faced by the framework in the segmentation is the speckle noise.It’s is a multiplicative and negative issue in breast ultrasound imaging,because of this noise,the image resolution and contrast become reduced,which affects the diagnostic value of this imaging modality.As result,speckle noise reduction is very vital for the segmentation process.The framework uses five models such as Generative Adversarial Denoising Network(DGAN-Net),Denoising U-Shaped Net(D-U-NET),Batch Renormalization U-Net(Br-UNET),Generative Adversarial Network(GAN),and Nonlocal Neutrosophic ofWiener Filtering(NLNWF)for reducing the speckle noise from the breast ultrasound images then choose the best image according to peak signal to noise ratio(PSNR)for each level of speckle-noise.The five used methods have been compared with classical filters such as Bilateral,Frost,Kuan,and Lee and they proved their efficiency according to PSNR in different levels of noise.The five diverse models are achieved PSNR results for speckle noise at level(0.1,0.25,0.5,0.75),(33.354,29.415,27.218,24.115),(31.424,28.353,27.246,24.244),(32.243,28.42,27.744,24.893),(31.234,28.212,26.983,23.234)and(33.013,29.491,28.556,25.011)forDGAN,Br-U-NET,D-U-NET,GANand NLNWF respectively.According to the value of PSNR and level of speckle noise,the best image passed for segmentation using U-Net and classification usingCNNto detect tumor type.The experiments proved the quality ofU-Net and CNN in segmentation and classification respectively,since they achieved 95.11 and 95.13 in segmentation and 95.55 and 95.67 in classification as dice score and accuracy respectively.
基金National Institutes of Health,Grant/Award Number:EB023969 and HL154687。
文摘Background:As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues,a need has developed for reliable imaging phantoms for use in system design and component calibration.In advanced imaging modalities such as refraction-based methods,it is critical that developed phantoms capture the biological details seen in clinical precancerous and cancerous cases while minimizing artifacts that may be caused due to phantom production.This work presents the fabrication of a breast tissue imaging phantom from cadaveric breast tissue suitable for use in both transmission and refraction-enhanced imaging systems.Methods:Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into the fixed tissue while maintaining the native tumor/adipose tissue interface.Results:The resulting human–murine tissue hybrid phantom was mounted on a clear acrylic housing for absorption and refraction X-ray imaging.Digital breast tomosynthesis was also performed.Conclusion:Both attenuation-based imaging and refraction-based imaging of the phantom are presented to confirm the suitability of this phantom's use in both imaging modalities.
文摘Deep neural network(DNN)based computer-aided breast tumor diagnosis(CABTD)method plays a vital role in the early detection and diagnosis of breast tumors.However,a Brightness mode(B-mode)ultrasound image derives training feature samples that make closer isolation toward the infection part.Hence,it is expensive due to a metaheuristic search of features occupying the global region of interest(ROI)structures of input images.Thus,it may lead to the high computational complexity of the pre-trained DNN-based CABTD method.This paper proposes a novel ensemble pretrained DNN-based CABTD method using global-and local-ROI-structures of B-mode ultrasound images.It conveys the additional consideration of a local-ROI-structures for further enhan-cing the pretrained DNN-based CABTD method’s breast tumor diagnostic performance without degrading its visual quality.The features are extracted at various depths(18,50,and 101)from the global and local ROI structures and feed to support vector machine for better classification.From the experimental results,it has been observed that the combined local and global ROI structure of small depth residual network ResNet18(0.8 in%)has produced significant improve-ment in pixel ratio as compared to ResNet50(0.5 in%)and ResNet101(0.3 in%),respectively.Subsequently,the pretrained DNN-based CABTD methods have been tested by influencing local and global ROI structures to diagnose two specific breast tumors(Benign and Malignant)and improve the diagnostic accuracy(86%)compared to Dense Net,Alex Net,VGG Net,and Google Net.Moreover,it reduces the computational complexity due to the small depth residual network ResNet18,respectively.
文摘The present work proposed a simple model for breast cancer hyperthermia treatment at 2.45 GHz. The proposed model involves nine-element antennas alongside a numerical breast comprising multiple tumors. Using a coupled EM-Thermal simulation in the CST suite, the simulated results for a single antenna showed a reflection coefficient (S<sub>11</sub>) better than -47 dB and demonstrated a bandwidth of 78 MHz. The specific absorption rate (SAR) as a function of input powers was examined inside the breast tissues, where it exhibited a promising performance higher than 3 W/kg at the tumor volume when the applied power was at a reasonable level of 1.5 W whereas it was well attained under the recommend IEEE level of 1.6 W/kg through the surrounded health tissues. Taking into consideration nine-element antennas covering the breast containing two different located tumors, the maximum temperature as a function of treatment time was presented at which a resulting temperature of 43°C was obtainable within 10 minutes, favored for hyperthermia purposes. Considering the maximum power level of 1.5 W, the potential use of applying three-element antennas, simultaneously with 0.5 W, could be achieved.
文摘A 49-year-old woman was referred to the Department of Plastic and Breast Surgery under suspicion of breast cancer after a mammogram revealed a self-discovered tumor in the lower part of her left breast. Clinical examination, mammography, and histopathological examination revealed that the original tumor in the left breast was benign, and an incidental malignant tumor, a dermatofibrosarcoma protuberans (DFSP), was found in the contralateral breast. DFSP is a rare and highly malignant entity that is often silent and difficult to diagnose, making a biopsy essential. Surgical treatment must be aggressive due to the high risk of recurrence, which constitutes a technical challenge. The patient underwent surgery using an oncoplastic approach with a volume-reducing technique to achieve the best possible therapeutic and aesthetic results. Therapeutic breast reduction was performed on the right breast and the tumor was removed within the resected tissue. A contralateral symmetrizing mammoplasty was also performed simultaneously. The patient was discharged without major complications, and no recurrence of the tumor was seen during the 30-month follow-up period. The surgical approach included alternative solutions in addition to conventional lumpectomy or mastectomy. A multidisciplinary, open-minded, and creative approach resulted in a satisfying outcome for this patient.
文摘A novel approach to image hemoglobin concentration(△Dhb) and oxygen saturation (△Doxy) of breast tissue is presented. The scenograph of dual-wavelength (760 and 850 nm) near infrared lights through breast tissue is acquired by high sensitive charge coupled device (CCD) camera. The evaluation criterion of the difference of △Dhh and △Doxy between detected and referenced breast tissue can be obtained by a calculation formula without complicate caculation. This approach is applied to clinic detection in breast tissue. The ongoing clinical experiments indicate that malignant tumor usually exhibits characterize of "higher △Dhb and lower △Doxy", while benign lesion often shows "lower △Dhb and higher △Doxy" or other characters. So it is useful to assist the diagnosis of breast disease.
文摘BACKGROUND The diagnostic specificity of conventional ultrasound for breast non-mass lesions(NMLs)is low at approximately 21%-43%.Shear wave elastography(SWE)can distinguish benign from malignant lesions by evaluating the internal and peripheral stiffness.SWE has good reproducibility and high diagnostic efficacy.However,there are very few independent studies on the diagnostic value of SWE in breast NMLs.AIM To determine the value of SWE in the differential diagnosis of breast NMLs.METHODS This study enrolled a total of 118 patients with breast NMLs who underwent SWE examinations in the Beijing Shijitan Hospital Affiliated to Capital Medical University and The Second Hospital of Shandong University from January 2019 to January 2020.The internal elastic parameters of the lesions were recorded,including maximum(Emax),mean(Emean)and minimum elastic values and the standard deviation.The following peripheral parameters were noted:Presence of a“stiff rim”sign;Emax,and Emean elasticity values within 1 mm,1.5 mm,2 mm,2.5 mm and 3 mm from the edge of NMLs.The receiver operating characteristic curve of each parameter was drawn,and the areas under the curve were calculated.RESULTS Emax,Emean and elastic values,and the standard deviation of the internal elastic values in malignant NMLs were significantly higher than those in benign NMLs(P<0.05).The percentage with the“stiff rim”sign in malignant NMLs was significantly higher than that in the benign group(P<0.05),and Emax and Emean at the shell of 1 mm,1.5 mm,2 mm,2.5 mm and 3 mm in the malignant group were all higher than those in the benign group(P<0.05).Of the surrounding elasticity values,Emax of the shell at 2.5 mm in malignant NMLs had maximum areas under the curve of 0.900,and the corresponding sensitivity and specificity were 94.57%and 85.86%,respectively.CONCLUSION The“stiff rim”sign and multiple quantitative elastic values within and around the lesion had good diagnostic performance in the differential diagnosis of breast NMLs.Emax in peripheral tissue had better diagnostic efficiency than other parameters.
文摘BACKGROUND Breast non-mass-like lesions(NMLs)account for 9.2%of all breast lesions.The specificity of the ultrasound diagnosis of NMLs is low,and it cannot be objectively classified according to the 5th Edition of the Breast Imaging Reporting and Data System(BI-RADS).Contrast-enhanced ultrasound(CEUS)can help to differentiate and classify breast lesions but there are few studies on NMLs alone.AIM To analyze the features of benign and malignant breast NMLs in grayscale ultrasonography(US),color Doppler flow imaging(CDFI)and CEUS,and to explore the efficacy of the combined diagnosis of NMLs and the effect of CEUS on the BI-RADS classification of NMLs.METHODS A total of 51 breast NMLs verified by pathology were analyzed in our hospital from January 2017 to April 2019.All lesions were examined by US,CDFI and CEUS,and their features from those examinations were analyzed.With pathology as the gold standard,binary logic regression was used to analyze the independent risk factors for malignant breast NMLs,and a regression equation was established to calculate the efficiency of combined diagnosis.Based on the regression equation,the combined diagnostic efficiency of US combined with CEUS(US+CEUS)was determined.The initial BI-RADS-US classification of NMLs was adjusted according to the independent risk factors identified by CEUS,and the diagnostic efficiency of CEUS combined with BI-RADS(CEUS+BI-RADS)was calculated based on the results.ROC curves were drawn to compare the diagnostic values of the three methods,including US,US+CEUS,and CEUS+BI-RADS,for benign and malignant NMLs.RESULTS Microcalcification,enhancement time,enhancement intensity,lesion scope,and peripheral blood vessels were significantly different between benign and malignant NMLs.Among these features,microcalcification,higher enhancement,and lesion scope were identified as independent risk factors for malignant breast NMLs.When US,US+CEUS,and CEUS+BI-RADS were used to identify the benign and malignant breast NMLs,their sensitivity rates were 82.6%,91.3%,and 87.0%,respectively;their specificity rates were 71.4%,89.2%,and 92.9%,respectively;their positive predictive values were 70.4%,87.5%,and 90.9%,respectively;their negative predictive values were 83.3%,92.6%,and 89.7%,respectively;their accuracy rates were 76.5%,90.2%,and 90.2%,respectively;and their corresponding areas under ROC curves were 0.752,0.877 and 0.903,respectively.Z tests showed that the area under the ROC curve of US was statistically smaller than that of US+CEUS and CEUS+BI-RADS,and there was no statistical difference between US+CEUS and CEUS+BI-RADS.CONCLUSION US combined with CEUS can improve diagnostic efficiency for NMLs.The adjustment of the BI-RADS classification according to the features of contrastenhanced US of NMLs enables the diagnostic results to be simple and intuitive,facilitates the management of NMLs,and effectively reduces the incidence of unnecessary biopsy.
文摘BACKGROUND The incidence rate of breast cancer has exceeded that of lung cancer,and it has become the most malignant type of cancer in the world.BI-RADS 4 breast nodules have a wide range of malignant risks and are associated with challenging clinical decision-making.AIM To explore the diagnostic value of artificial intelligence(AI)automatic detection systems for BI-RADS 4 breast nodules and to assess whether conventional ultrasound BI-RADS classification with AI automatic detection systems can reduce the probability of BI-RADS 4 biopsy.METHODS A total of 107 BI-RADS breast nodules confirmed by pathology were selected between June 2019 and July 2020 at Hwa Mei Hospital,University of Chinese Academy of Sciences.These nodules were classified by ultrasound doctors and the AI-SONIC breast system.The diagnostic values of conventional ultrasound,the AI automatic detection system,conventional ultrasound combined with the AI automatic detection system and adjusted BI-RADS classification diagnosis were statistically analyzed.RESULTS Among the 107 breast nodules,61 were benign(57.01%),and 46 were malignant(42.99%).The pathology results were considered the gold standard;furthermore,the sensitivity,specificity,accuracy,Youden index,and positive and negative predictive values were 84.78%,67.21%,74.77%,0.5199,66.10%and 85.42%for conventional ultrasound BI-RADS classification diagnosis,86.96%,75.41%,80.37%,0.6237,72.73%,and 88.46%for automatic AI detection,80.43%,90.16%,85.98%,0.7059,86.05%,and 85.94%for conventional ultrasound BI-RADS classification with automatic AI detection and 93.48%,67.21%,78.50%,0.6069,68.25%,and 93.18%for adjusted BI-RADS classification,respectively.The biopsy rate,cancer detection rate and malignancy risk were 100%,42.99%and 0%and 67.29%,61.11%,and 1.87%before and after BI-RADS adjustment,respectively.CONCLUSION Automatic AI detection has high accuracy in determining benign and malignant BI-RADS 4 breast nodules.Conventional ultrasound BI-RADS classification combined with AI automatic detection can reduce the biopsy rate of BI-RADS 4 breast nodules.
基金supported by grants from the National Natural Science Foundation of China(No.81172467)the Natural Science Foundation of Hubei Province(No.2012FFB02509)
文摘Over-expression of Fas ligand (FasL) on tumor cell surface can induce the apoptosis of spe- cific activated tumor infiltrating lymphocytes (TILs) via the Fas/FasL pathway, leading to the formation of a site of immune privilege surrounding the tumor mass for escaping immune surveillance and pro- moting tumor proliferation, invasion and metastasis. The blocking effect of miR-21 on FasL-mediated apoptosis in breast cancers was investigated in this study. The expression levels of miR-21 and FasL in human breast carcinoma cell lines were detected by using RT-PCR and Western blotting. FasL as a tar- get gene of miR-21 was identified by Luciferase assay. The apoptosis of Jurkat T lymphocytes induced by MCF-7 cells was determined by flow cytometry. It was found that in four human breast cancer cell lines, FasL expression level in MCF-7 cells was the highest, while miR-21 was down-regulated the most notably. After miR-21 expression in MCF-7 cells was up-regulated, FasL was identified as a target gene of miR-21. When the effector/target (E/T) ratio of MCF-7 cells and Jurkat cells was 10:1, 5:1 and 1:1, the inhibitory rate of apoptosis of Jurkat T lymphocytes induced by MCF-7 cells was 95.81%, 93.16% and 91.94%, respectively. It is suggested that in breast cancers miR-21 expression is negatively associ- ated with FasL expression, and FasL is a target gene of miR-21, miR-21 targeting and regulating FasL-mediated apoptosis will bring us the possibility of a new tumor immunotherapy via breaking tu- mor immune privilege.
基金a grant from the Medicine Scientific Development Foun-dation of Nanjing(No.zkx05021).
文摘Objective:To study the diagnostic value of T2*-weighted first-pass perfusion imaging in breast tumors.Methods: We analyzed the magnetic resonance imaging(MRI)information along with the pathological and immunohistochemistry re- sults.Magnetic resonance imaging was performed in 28 patients with breast tumor.The time to signal intensity curves were generated according to the T2*-weighted first-pass perfusion imaging.The curve’s maximal signal intensity drop rate and maximal signal intensity decrease time were analyzed and compared with the pathological diagnoses after surgery.Results: Malignant breast lesions showed higher maximal signal intensity drop rate(44.69%±17.07 vs.17.22%±7.49,P<0.001) than benign lesions,but there was no significant difference of maximal signal decrease time between those two lesions(23.94 s±4.92 vs.20.02 s±6.83,P>0.05).Conclusion:The T2*-weighted first-pass perfusion imaging has enough sensitivity and specificity in breast tumor diagnosis.
文摘BACKGROUND Adenomyoepithelioma(AME)of the breast is a rare type of benign breast tumor.Many AMEs show benign behavior,but reports of the malignant type are rare.We present the case of a patient with AME with repeated local recurrences and further malignant transformation.CASE SUMMARY A 53-year-old woman visited our hospital with a 16-mm palpable mass in the right breast.A core needle biopsy was performed.The pathological diagnosis was AME.Lumpectomy with a safety margin was performed without axillary lymph node dissection(ALND).Two years later,local recurrence developed,and the patient again underwent lumpectomy with a safety margin.The pathology showed malignant AME,and the margin was negative.Eight months later,local recurrence developed again in the same location,and a total mastectomy was performed without ALND.The pathological diagnosis was malignant AME.The patient was disease-free for three years posttreatment.CONCLUSION The treatment of AME requires caution,as it may exhibit repeated recurrences after local excision as well as malignant transformation.
文摘BACKGROUND Patients with an in-breast tumor recurrence(IBTR)after breast-conserving therapy have a high risk of distant metastasis and disease-related mortality.Classifying clinical parameters that increase risk for recurrence after IBTR remains a challenge.AIM To describe primary and recurrent tumor characteristics in patients who experience an IBTR and understand the relationship between these characteristics and disease outcomes.METHODS Patients with stage 0-II breast cancer treated with lumpectomy and adjuvant radiation were identified from institutional databases of patients treated from 2003-2017 at our institution.Overall survival(OS),disease-free survival,and local recurrence-free survival(LRFS)were estimated using the Kaplan Meier method.We identified patients who experienced an isolated IBTR.Concordance of hormone receptor status and location of tumor from primary to recurrence was evaluated.The effect of clinical and treatment parameters on disease outcomes was also evaluated.RESULTS We identified 2164 patients who met the eligibility criteria.The median follow-up for all patients was 3.73[interquartile range(IQR)2.27-6.07]years.Five-year OS was 97.7%(95%CI:96.8%-98.6%)with 28 deaths;5-year LRFS was 98.0%(97.2-98.8)with 31 IBTRs.We identified 37 patients with isolated IBTR,19(51.4%)as ductal carcinoma in situ and 18(48.6%)as invasive disease,of whom 83.3%had an in situ component.Median time from initial diagnosis to IBTR was 1.97(IQR:1.03-3.5)years.Radiotherapy information was available for 30 of 37 patients.Median whole-breast dose was 40.5 Gy and 23 patients received a boost to the tumor bed.Twenty-five of thirty-two(78.1%)patients had concordant hormone receptor status,HER-2 receptor status,and estrogen receptor(ER)(P=0.006)and progesterone receptor(PR)(P=0.001)status from primary to IBTR were significantly associated.There were no observed changes in HER-2 status from primary to IBTR.The concordance between quadrant of primary to IBTR was 10/19[(62.2%),P=0.008].Tumor size greater than 1.5 cm(HR=0.44,95%CI:0.22-0.90,P=0.02)and use of endocrine therapy upfront(HR=0.36,95%CI:0.18-0.73,P=0.004)decreased the risk of IBTR.CONCLUSION Among patients with early stage breast cancer who had breast conserving surgery treated with adjuvant RT,ER/PR status and quadrant were highly concordant from primary to IBTR.Tumor size greater than 1.5 cm and use of adjuvant endocrine therapy were significantly associated with decreased risk of IBTR.
文摘BREAST fibromatosis is a rare kind of lesion. The average incidence is about 2-4 per million every year} So far there have been about 100 cases reported altogether.2 In this report, we describe a case of breast fibromatosis developed after hydrophilic polyacrylamide gel (HPG) injection for breast augmentation. By reviewing the literature, the possible pathogenesis of this case and the proper treatment strategy are investigated.
基金supported in part by grants from the National Natural Science Foundation of China(11672051)Fundamental Research Funds for the Central Universities(2018CDQYSG0015).
文摘Mechanical microenvironment can strongly affect the metastatic efficiency of circulating tumor cells.However,the effect of suspension state on their extravasation and the mechanisms involved are still unclear.To explore the influence of suspension state on extravasation(including adhesion,spreading and transendothelial migration)of breast tumor cells and its relevant molecular mechanism,MDA-MB-231 cells were cultured on poly(2-hydroxyethyl methacrylate)coated 6-well plates to minic the suspension state.Suspension state promoted adhesion,spreading and transendothelial migration of MDA-MB-231 cells to EAhy926 endothelial cells(ECs)monolayer under both the static condition and 0.5 dyne/cm^(2) flow shear stress(FSS).The number of cells adhered to ECs monolayer reached 2.15(static condition,3 d)and 1.67(FSS,3 d)times,and the number of migration reached 10.60 times,respectively,as compared to that in adhesion state.Moreover,MDA-MB-231 cells knockdown of integrin β1 provoked poor adhesion and transendothelial migration,as compared with MDA-MB-231 cells.But it made no difference in cell spreading.Our results implied the increasing expression of integrin β1 induced by suspension culture promoted the adhesion and transendothelial migration of MDA-MB-231 cells,but had no significant influence on their spreading.
基金Supported by the Ministry of Health Science Foundation for Distinguished Youth Scholar (No.97028).
文摘Objective: To investigate the expression of cyclin E in breast cancer tissues and its relationship with prognosis of the patients with breast cancer. Methods: The expression of cyclin E, HER-2/neu, nm23-H1 and actin was detected in 80 breast cancer tissues and 18 benign breast tumor tissues by immunohistochemical methods. The relationship between cyclin E and the remaining genes or the clinical data of the patients with breast cancer was analyzed. Results: The over expression rate of cyclin E in malignant tissues was obviously higher than that in benign tumor tissues (P〈0.01). The over expression of cyclin E in later stage of disease was higher than that in early stage of disease (P〈0.05). The expression of cyclin E in ER positive tissues was lower than that in ER negative tissues (P〈0.05). The expression of cyclin E in PR positive tissues and PR negative tissues had no significant difference (P〉0.05). The expression of cyclin E in HER-2/neu positive tissues was higher than that in HER-2/neu negative tissues (P〈0.05). And the expression of cyclin E in ER, PR and HER-2/neu all positive tissues was much higher (P〈0.01). There was no significant difference in the expression of cyclin E between nm23-H1 positive tissues and nm23-H1 negative tissues (P〉0.05). The expression of cyclin E in actin positive and continuous distribution tissues was lower than that in actin negative or discontinuous distribution tissues (P〈0.05). Conclusion: The expression of cyclin E has a strong correlation to the prognosis of the patients with breast cancer.
基金The project supported by National Natural Science Foundation of China(81202840,81373815)Specialized Research Fund for the Doctoral Program of Higher Education of China(20131107110014)+1 种基金Beijing Natural Science Foundation(7162084)Swedish Cancer Foundation(150815)
文摘OBJECTIVE GubenyiliuⅡ(GYⅡ),a traditional Chinese medicine(TCM)formula used in our hospital,has shown beneficial effects in cancer patients.In this study,we investigated the molecular mechanisms underlying the beneficial effects of GYⅡon murine breast cancer models.METHODS Inhibition of tumor growth and metastasis was evaluated by assessment of tumor weight and analysis of bioluminescent signal after a homograft inoculation.Viability of cultured breast cancer cells was determined using MTT assay andreal-time cell analysis(RTCA).Cell migratory ability was evaluated by Transwell?assay and wound healing assay.Subsequently,the potential anti-tumor and anti-metastatic mechanism was investigated by Western blotting and Immunohistochemistry.RESULTS GYⅡshowed significant inhibitory effects on tumor growth and metastasis in the murine breast cancer model.And GYⅡsuppressed theproliferation of 4T1 and MCF-7 cells in a dose-dependent manner.A better inhibitory effect on 4T1 cells proliferation and migration was found in sub-fractions(SF)of GYⅡ.Moreover,heparanase expression and degree of angiogenesis were reduced in tumor tissues.Western blotting analysis showed decreased expression of heparanase and growth factors in the cells treated with GYⅡand its sub-fractions(SF2 and SF3),there by a reduction in phosphorylation of ERK and AKT.CONCLUSION GYⅡexerts anti-tumor growth and anti-metastatic effects on murine breast cancer model.Sub-fractions 2 and 3 exhibits higher potency of the anti-tumor activity that is,at least partly,associated with decreased heparanase and growth factor sexpression,which subsequently sup-pressed activation of ERK and AKT pathways.
文摘A number of studies have been shown that retiniods can inhibit malignant cell growth including certain breast carcinoma cells. Its inhibitory effort is observed only in ER-positive but not in ER-negative breast cancer cells. We examined retinoic acid receptors (RARs) and retinoids X receptors (RXRs) levels in 6 breast carcinoma cell lines and 18 breast cancer biopsy specimens. We found that RAR-α mRNA level was significantly higher in ER positive cell lines and samples. RAR-γ mRNA was expressed at relatively high levels in majority of tumor samples independent of the ER-status while RAR-β mRNA was expressed at low levels. We also found high RXR-α mRNA levels in all of the tumor samples examined while RXR-γ mRNA could not be detected. Our study suggests a possibility that retinoids inhibit tumor cell growth through RAR-a and RAR-α levels may serve as a potential marker to determine responsiveness of patients to retinoids therapy.