To explore the effect of particle size on the quality uniformity and in vitro release performance of Strychnos nux-vomica powder, seven samples of Strychnos nux-vomica powder with different particle sizes were prepare...To explore the effect of particle size on the quality uniformity and in vitro release performance of Strychnos nux-vomica powder, seven samples of Strychnos nux-vomica powder with different particle sizes were prepared.Microstructures and particle sizes were analyzed, and high performance liquid chromatography(HPLC) was used to test the contents and in vitro release performances of brucine and strychnine in the samples. Results showed that the contents and the in vitro release rates of brucine(or strychnine) in different samples were different since there are different proportions of endosperms to epidermal cells in Strychnos nux-vomica powder with different particle sizes. Brucine and strychnine in each sample were promptly released in the first ten minutes and their cumulative release rates were higher than 70% after ten minutes. Eighty minutes later, the cumulative release rate tended to be a constant. Considering the quality uniformity and safety of Strychnos nux-vomica powder used as traditional Chinese medicine, it would be better to control the particle size of Strychnos nux-vomica powder between 100 and 140 mesh in which the maximum cumulative release rate in vitro of brucine and strychnine can be relatively low within this range.展开更多
A novel micelle to solvent stacking on-line sample preconcentration technique in capillary zone electrophoresis(MSS-CZE) has been developed to determine the strychnine and brucine in traditional Chinese medicine pre...A novel micelle to solvent stacking on-line sample preconcentration technique in capillary zone electrophoresis(MSS-CZE) has been developed to determine the strychnine and brucine in traditional Chinese medicine preparations.The optimal running buffer was 30 mmol/L H_3PO_4 containing 20%acetonitrile at pH 4.0.The sample matrix was 8 mmol/L H_3PO_4 containing 5 mmol/L sodium dodecyl sulfate(SDS) at pH 3.0.The established MSS-CZE method afforded more than 50-fold improvements in concentration sensitivity compared with typical CZE-UV analysis.The calibration curve was linear in the range from 0.2 to 15.0μg/ mL for both strychnine and brucine,with correlation coefficients of 0.9984 and 0.9976,respectively.The limits of detection(5/ N = 3:1) for strychnine and brucine were 0.02 and 0.05μg/mL,respectively.The MSS-CZE method has been successfully applied to the analysis of strychnine and brucine in Chinese medicinal preparations.展开更多
OBJECTIVE:To investigate the antagonistic effect of the extract of Baizhu(Rhizoma Atractylodis Macrocephalae)(RAM)on the intestinal absorption of brucine and strychnine in Strychnos nux-vomica(NUX)and propose the mech...OBJECTIVE:To investigate the antagonistic effect of the extract of Baizhu(Rhizoma Atractylodis Macrocephalae)(RAM)on the intestinal absorption of brucine and strychnine in Strychnos nux-vomica(NUX)and propose the mechanism of these effects.METHODS:The apparent permeability value(Papp)and absorption rate constant(Ka)were chosen as indices.The everted intestinal sac model and in situ single-pass intestinal perfusion model were used to study the effects of the RAM extract on the absorption of brucine and strychnine.To confirm the results,the brucine and strychnine concentrations in hepatic portal venous blood were determined.Western blotting was used to study P-glycoprotein(P-gp)expression in the Caco-2 cell line.RESULTS:Papp and Ka of brucine and strychnine were significantly increased in the presence of a P-gp inhibitor,but no significant increase was noted in the presence of a tight junction regulator.The RAM extract inhibited the absorption of brucine and strychnine and enhanced P-gp expression.CONCLUSION:The primary absorption mechanism for brucine and strychnine is passive transport,which is affected by P-gp.展开更多
基金Supported by the Plan Issue of Shanghai Science &Technology Committee(No.13401901100)
文摘To explore the effect of particle size on the quality uniformity and in vitro release performance of Strychnos nux-vomica powder, seven samples of Strychnos nux-vomica powder with different particle sizes were prepared.Microstructures and particle sizes were analyzed, and high performance liquid chromatography(HPLC) was used to test the contents and in vitro release performances of brucine and strychnine in the samples. Results showed that the contents and the in vitro release rates of brucine(or strychnine) in different samples were different since there are different proportions of endosperms to epidermal cells in Strychnos nux-vomica powder with different particle sizes. Brucine and strychnine in each sample were promptly released in the first ten minutes and their cumulative release rates were higher than 70% after ten minutes. Eighty minutes later, the cumulative release rate tended to be a constant. Considering the quality uniformity and safety of Strychnos nux-vomica powder used as traditional Chinese medicine, it would be better to control the particle size of Strychnos nux-vomica powder between 100 and 140 mesh in which the maximum cumulative release rate in vitro of brucine and strychnine can be relatively low within this range.
基金supported by the Natural Science Foundations of Hebei(NoB2010000657)
文摘A novel micelle to solvent stacking on-line sample preconcentration technique in capillary zone electrophoresis(MSS-CZE) has been developed to determine the strychnine and brucine in traditional Chinese medicine preparations.The optimal running buffer was 30 mmol/L H_3PO_4 containing 20%acetonitrile at pH 4.0.The sample matrix was 8 mmol/L H_3PO_4 containing 5 mmol/L sodium dodecyl sulfate(SDS) at pH 3.0.The established MSS-CZE method afforded more than 50-fold improvements in concentration sensitivity compared with typical CZE-UV analysis.The calibration curve was linear in the range from 0.2 to 15.0μg/ mL for both strychnine and brucine,with correlation coefficients of 0.9984 and 0.9976,respectively.The limits of detection(5/ N = 3:1) for strychnine and brucine were 0.02 and 0.05μg/mL,respectively.The MSS-CZE method has been successfully applied to the analysis of strychnine and brucine in Chinese medicinal preparations.
基金the National Natural Science Foundation of China(No.81660757 and No.81303237)the Academic and Technological Foregoer Funds of Jiangxi Province,China(No.20162BCB22015)+3 种基金the Project on Cultivation of Medical Elite(Gan Po Ying Cai 555)(2013296)the Youth Science Funds of Jiangxi Province,China(No.20153BCB23019)the National Natural Science Foundation of Jiangxi Province(No.20161ACB21020)the Natural Science Research Project of Huaian(No.HAB201716)。
文摘OBJECTIVE:To investigate the antagonistic effect of the extract of Baizhu(Rhizoma Atractylodis Macrocephalae)(RAM)on the intestinal absorption of brucine and strychnine in Strychnos nux-vomica(NUX)and propose the mechanism of these effects.METHODS:The apparent permeability value(Papp)and absorption rate constant(Ka)were chosen as indices.The everted intestinal sac model and in situ single-pass intestinal perfusion model were used to study the effects of the RAM extract on the absorption of brucine and strychnine.To confirm the results,the brucine and strychnine concentrations in hepatic portal venous blood were determined.Western blotting was used to study P-glycoprotein(P-gp)expression in the Caco-2 cell line.RESULTS:Papp and Ka of brucine and strychnine were significantly increased in the presence of a P-gp inhibitor,but no significant increase was noted in the presence of a tight junction regulator.The RAM extract inhibited the absorption of brucine and strychnine and enhanced P-gp expression.CONCLUSION:The primary absorption mechanism for brucine and strychnine is passive transport,which is affected by P-gp.