The heat transfer performance of the phase change materials used in free cooling and air conditioning applications is low,due to the poor thermal conductivity of the materials.The recent phenomenal advancement in nano...The heat transfer performance of the phase change materials used in free cooling and air conditioning applications is low,due to the poor thermal conductivity of the materials.The recent phenomenal advancement in nano technology provides an opportunity for an appreciable enhancement in the thermal conductivity of the phase change materials.In order to explore the possibilities of using nano technology for various applications,a detailed parametric study is carried out,to analyse the heat transfer enhancement potential with the thermal conductivity of the conventional phase change materials and nano enhanced phase change materials under various flow conditions of the heat transfer fluid.Initially,the theoretical equation,used to determine the time for outward cylindrical solidification of the phase change material,is validated with the experimental results.It is inferred from the parametric studies,that for paraffinic phase change materials with air as the heat transfer fluid,the first step should be to increase the heat transfer coefficient to the maximum extent,before making any attempt to increase the thermal conductivity of the phase change materials,with the addition of nano particles.When water is used as the phase change material,the addition of nano particles is recommended to achieve better heat transfer,when a liquid is used as the heat transfer fluid.展开更多
Deep Q Network(DQN)is an efficient model-free optimization method,and has the potential to be used in building cooling water systems.However,due to the high dimension of actions,this method requires a complex neural n...Deep Q Network(DQN)is an efficient model-free optimization method,and has the potential to be used in building cooling water systems.However,due to the high dimension of actions,this method requires a complex neural network.Therefore,both the required number of training samples and the length of convergence period are barriers for real application.Furthermore,penalty function based exploration may lead to unsafe actions,causing the application of this optimization method even more difficult.To solve these problems,an approach to limit the action space within a safe area is proposed in this paper.First of all,the action space for cooling towers and pumps are separated into two sub-regions.Secondly,for each type of equipment,the action space is further divided into safe and unsafe regions.As a result,the convergence speed is significantly improved.Compared with the traditional DQN method in a simulation environment validated by real data,the proposed method is able to save the convergence time by 1 episode(one cooling season).The results in this paper suggest that,the proposed DQN method can achieve a much quicker learning speed without any undesired consequences,and therefore is more suitable to be used in projects without pre-learning stage.展开更多
Night cooling of building is considered as a technology with a high potential of impact on air conditioning energy needs. Natural ventilation should be the first option for night cooling, for obvious reasons of energy...Night cooling of building is considered as a technology with a high potential of impact on air conditioning energy needs. Natural ventilation should be the first option for night cooling, for obvious reasons of energy savings. The evaluation of the capacity of the building to cool down its structures during night ventilation is of primary concern during preliminary design stage, even though night cooling with natural ventilation is among the most complex problem to be modelled in details. Some modelling options are available, assuming different simplifications in space and time. Among them, virtual sphere modelling has been proposed in the past as a quick way to perform dynamic simulation of the night cooling of buildings. In this paper, the theoretical origin of the virtual sphere model is recalled, underlining its limits in case of application to buoyancy driven night cooling of buildings. The limits can explain the disagreements of virtual sphere prediction with other methods reported in literature and may stimulate a more conscious application of the model and further improvements of the method.展开更多
The distributed energy system has achieved significant attention in respect of its application for singlebuilding cooling and heating.Researching on the life cycle environmental impact of distributed energy systems(DE...The distributed energy system has achieved significant attention in respect of its application for singlebuilding cooling and heating.Researching on the life cycle environmental impact of distributed energy systems(DES)is of great significance to encourage and guide the development of DES in China.However,the environmental performance of distributed energy systems in a building cooling and heating has not yet been carefully analyzed.In this study,based on the standards of ISO14040-2006 and ISO14044-2006,a life-cycle assessment(LCA)of a DES was conducted to quantify its environmental impact and a conventional energy system(CES)was used as the benchmark.GaBi 8 software was used for the LCA.And the Centre of Environmental Science(CML)method and Eco-indicator 99(EI 99)method were used for environmental impact assessment of midpoint and endpoint levels respectively.The results indicated that the DES showed a better life-cycle performance in the usage phase compared to the CES.The life-cycle performance of the DES was better than that of the CES both at the midpoint and endpoint levels in view of the whole lifespan.It is because the CES to DES indicator ratios for acidification potential,eutrophication potential,and global warming potential are 1.5,1.5,and 1.6,respectively at the midpoint level.And about the two types of impact indicators of ecosystem quality and human health at the endpoint level,the CES and DES ratios of the other indicators are greater than1 excepting the carcinogenicity and ozone depletion indicators.The human health threat for the DES was mainly caused by energy consumption during the usage phase.A sensitivity analysis showed that the climate change and inhalable inorganic matter varied by 1.3%and 6.1%as the electricity increased by 10%.When the natural gas increased by 10%,the climate change and inhalable inorganic matter increased by 6.3%and 3.4%,respectively.The human health threat and environmental damage caused by the DES could be significantly reduced by the optimization of natural gas and electricity consumption.展开更多
Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family...Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">chiller plants (HCPs)</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">using multiple chillers and different energy sources</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">are highly recommended in several energy applications in non-residential buildings such as hospitals and hotels. Time of use and cooling load profiles are significant factors that should be carefully considered either in chiller plant design or in chiller sequencing operation. This article aims to present an operation planning of HCP which consists of both electric and non-electric chillers. Four operational strategies are proposed and solved to compare their coefficients of performance and economics of running costs. A typical hotel building located on the Nile river in Egypt is selected to perform the current thermal and economic case study. The total cooling load profile of this hotel building is 4000 refrigeration tonnage (TR), which </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">is </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">simulated to optimize chiller sequence of operation and to select optimal design conditions of both numbers for electric and non-electric chillers used in HCP. The results of this comparative study for running cost are defined using various design configurations with different several chiller sequences available for each configuration. Then, the results of COPs, and operational running cost and initial cost are presented in this article also. The comparison aims to find the optimal design and operational sequencing for HCPs on thermal basis and economic analysis which were attached in this article. Recommendations and suggestions for future work are attached at the end of this article.</span></span></span>展开更多
The thermal properties of different clay samples obtained from locations in Akwa Ibom State, Nigeria were investigated and compared, and in order to establish their suitability as building material from energy conserv...The thermal properties of different clay samples obtained from locations in Akwa Ibom State, Nigeria were investigated and compared, and in order to establish their suitability as building material from energy conservation point of view. The results showed that stoneware clay has the highest solar radiation absorptivity of 22 32 m -1 while kaolin clay has the lowest radiation absoptivity of 14 46 m -1 A model for the prediction of temperature variation with thickness of the samples was developed. Results showed that kaolin would make the best choice for the design of a naturally cooled building.展开更多
Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy...Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy efficiency. The main contribution of this work is modeling the telecommunication building for the fabric cooling load to schedule the operation of air conditioners. The time series data of the fabric cooling load of the building envelope is taken by simulation by using Energy Plus, Building Control Virtual Test Bed (BCVTB), and Matlab. This pre-computed data and other internal thermal loads are used for scheduling in air conditioners. Energy savings obtained for the whole year are about 4% to 6% by simulation and the field study, respectively.展开更多
文摘The heat transfer performance of the phase change materials used in free cooling and air conditioning applications is low,due to the poor thermal conductivity of the materials.The recent phenomenal advancement in nano technology provides an opportunity for an appreciable enhancement in the thermal conductivity of the phase change materials.In order to explore the possibilities of using nano technology for various applications,a detailed parametric study is carried out,to analyse the heat transfer enhancement potential with the thermal conductivity of the conventional phase change materials and nano enhanced phase change materials under various flow conditions of the heat transfer fluid.Initially,the theoretical equation,used to determine the time for outward cylindrical solidification of the phase change material,is validated with the experimental results.It is inferred from the parametric studies,that for paraffinic phase change materials with air as the heat transfer fluid,the first step should be to increase the heat transfer coefficient to the maximum extent,before making any attempt to increase the thermal conductivity of the phase change materials,with the addition of nano particles.When water is used as the phase change material,the addition of nano particles is recommended to achieve better heat transfer,when a liquid is used as the heat transfer fluid.
文摘Deep Q Network(DQN)is an efficient model-free optimization method,and has the potential to be used in building cooling water systems.However,due to the high dimension of actions,this method requires a complex neural network.Therefore,both the required number of training samples and the length of convergence period are barriers for real application.Furthermore,penalty function based exploration may lead to unsafe actions,causing the application of this optimization method even more difficult.To solve these problems,an approach to limit the action space within a safe area is proposed in this paper.First of all,the action space for cooling towers and pumps are separated into two sub-regions.Secondly,for each type of equipment,the action space is further divided into safe and unsafe regions.As a result,the convergence speed is significantly improved.Compared with the traditional DQN method in a simulation environment validated by real data,the proposed method is able to save the convergence time by 1 episode(one cooling season).The results in this paper suggest that,the proposed DQN method can achieve a much quicker learning speed without any undesired consequences,and therefore is more suitable to be used in projects without pre-learning stage.
文摘Night cooling of building is considered as a technology with a high potential of impact on air conditioning energy needs. Natural ventilation should be the first option for night cooling, for obvious reasons of energy savings. The evaluation of the capacity of the building to cool down its structures during night ventilation is of primary concern during preliminary design stage, even though night cooling with natural ventilation is among the most complex problem to be modelled in details. Some modelling options are available, assuming different simplifications in space and time. Among them, virtual sphere modelling has been proposed in the past as a quick way to perform dynamic simulation of the night cooling of buildings. In this paper, the theoretical origin of the virtual sphere model is recalled, underlining its limits in case of application to buoyancy driven night cooling of buildings. The limits can explain the disagreements of virtual sphere prediction with other methods reported in literature and may stimulate a more conscious application of the model and further improvements of the method.
基金Projects(51676209,22008265)supported by the National Natural Science Foundation of ChinaProjects(2020JJ6072,2021JJ50007)supported by the Hunan Province Natural Science Foundation,China。
文摘The distributed energy system has achieved significant attention in respect of its application for singlebuilding cooling and heating.Researching on the life cycle environmental impact of distributed energy systems(DES)is of great significance to encourage and guide the development of DES in China.However,the environmental performance of distributed energy systems in a building cooling and heating has not yet been carefully analyzed.In this study,based on the standards of ISO14040-2006 and ISO14044-2006,a life-cycle assessment(LCA)of a DES was conducted to quantify its environmental impact and a conventional energy system(CES)was used as the benchmark.GaBi 8 software was used for the LCA.And the Centre of Environmental Science(CML)method and Eco-indicator 99(EI 99)method were used for environmental impact assessment of midpoint and endpoint levels respectively.The results indicated that the DES showed a better life-cycle performance in the usage phase compared to the CES.The life-cycle performance of the DES was better than that of the CES both at the midpoint and endpoint levels in view of the whole lifespan.It is because the CES to DES indicator ratios for acidification potential,eutrophication potential,and global warming potential are 1.5,1.5,and 1.6,respectively at the midpoint level.And about the two types of impact indicators of ecosystem quality and human health at the endpoint level,the CES and DES ratios of the other indicators are greater than1 excepting the carcinogenicity and ozone depletion indicators.The human health threat for the DES was mainly caused by energy consumption during the usage phase.A sensitivity analysis showed that the climate change and inhalable inorganic matter varied by 1.3%and 6.1%as the electricity increased by 10%.When the natural gas increased by 10%,the climate change and inhalable inorganic matter increased by 6.3%and 3.4%,respectively.The human health threat and environmental damage caused by the DES could be significantly reduced by the optimization of natural gas and electricity consumption.
文摘Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">chiller plants (HCPs)</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">using multiple chillers and different energy sources</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">are highly recommended in several energy applications in non-residential buildings such as hospitals and hotels. Time of use and cooling load profiles are significant factors that should be carefully considered either in chiller plant design or in chiller sequencing operation. This article aims to present an operation planning of HCP which consists of both electric and non-electric chillers. Four operational strategies are proposed and solved to compare their coefficients of performance and economics of running costs. A typical hotel building located on the Nile river in Egypt is selected to perform the current thermal and economic case study. The total cooling load profile of this hotel building is 4000 refrigeration tonnage (TR), which </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">is </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">simulated to optimize chiller sequence of operation and to select optimal design conditions of both numbers for electric and non-electric chillers used in HCP. The results of this comparative study for running cost are defined using various design configurations with different several chiller sequences available for each configuration. Then, the results of COPs, and operational running cost and initial cost are presented in this article also. The comparison aims to find the optimal design and operational sequencing for HCPs on thermal basis and economic analysis which were attached in this article. Recommendations and suggestions for future work are attached at the end of this article.</span></span></span>
文摘The thermal properties of different clay samples obtained from locations in Akwa Ibom State, Nigeria were investigated and compared, and in order to establish their suitability as building material from energy conservation point of view. The results showed that stoneware clay has the highest solar radiation absorptivity of 22 32 m -1 while kaolin clay has the lowest radiation absoptivity of 14 46 m -1 A model for the prediction of temperature variation with thickness of the samples was developed. Results showed that kaolin would make the best choice for the design of a naturally cooled building.
基金support and facilities provieded by Bharat Sanchar Nigam Limited Chennai Telephones and Department of Telecommunications,India for this study
文摘Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy efficiency. The main contribution of this work is modeling the telecommunication building for the fabric cooling load to schedule the operation of air conditioners. The time series data of the fabric cooling load of the building envelope is taken by simulation by using Energy Plus, Building Control Virtual Test Bed (BCVTB), and Matlab. This pre-computed data and other internal thermal loads are used for scheduling in air conditioners. Energy savings obtained for the whole year are about 4% to 6% by simulation and the field study, respectively.