极端湿热环境对CFRP/钢界面性能的影响
1
作者 李传习 司睹英胡 高有为 《建筑材料学报》 EI CAS CSCD 北大核心 2024年第8期757-763,共7页
为掌握极端湿热环境下CFRP/钢界面性能的退化机理,用Sika-30胶黏剂制作了12个CFRP/钢双搭接试件,并在70℃的模拟海水中浸泡不同时间后进行拉伸剪切试验.结果表明:CFRP/钢双搭接试件的破坏模式受浸泡时长的影响较小;CFRP/钢界面平均抗剪... 为掌握极端湿热环境下CFRP/钢界面性能的退化机理,用Sika-30胶黏剂制作了12个CFRP/钢双搭接试件,并在70℃的模拟海水中浸泡不同时间后进行拉伸剪切试验.结果表明:CFRP/钢双搭接试件的破坏模式受浸泡时长的影响较小;CFRP/钢界面平均抗剪强度随浸泡时长呈先上升后下降趋势;浸泡90 d后,CFRP/钢界面平均抗剪强度较未浸泡试件下降了35.6%. 展开更多
关键词 cfrp/钢 破坏模式 黏结滑移本构关系 抗剪强度
下载PDF
Behavior of RC two-way slabs strengthened with CFRP-steel grid under concentrated loading
2
作者 Lu Yiyan Zhu Tao +1 位作者 Li Shan Zhang Haojun 《Journal of Southeast University(English Edition)》 EI CAS 2018年第3期331-339,共9页
A novel composite technique of orthogonally bonding carbon fiber-reinforced polymer (CFRP) strips and steel strips is proposed to improve the performance of reinforced concrete (RC) structures based on co-working ... A novel composite technique of orthogonally bonding carbon fiber-reinforced polymer (CFRP) strips and steel strips is proposed to improve the performance of reinforced concrete (RC) structures based on co-working of CFRP strips and steel strips. To verify the effectiveness of the method for strengthening RC two-way slabs, seven flat slabs with the dimensions of i 500 mm x 1 500 mm x 70 mm and an internal reinforcement ratio of 0.22% were prepared and tested until failure under concentrated loading, of which one was unstrengthened, one was strengthened with CFRP strips bonded to its soffit making a grid pattern (termed the CFRP grid), and five were strengthened with a hybrid grid of CFRP strips and steel strips in two orthogonal directions (termed the CFRP-steel grid) to the bottom with steel bolt anchorage. The investigation parameters are the strengthening method, the strip spacing (150, 200, and 250 mm) and the layers of CFRP strips (one layer, two layers, and three layers of CFRP strips are applied for CFRP-steel grid). The experimental results show that the strengthening RC two-way slabs with CFRP-steel grid are effective in delaying concrete cracking and enhancing the load-carrying capacity and deformability in comparison to the CFRP grid strengthening. The yield-line analysis model is proposed to predict the load-carrying capacity of the strengthened slabs. The prediction results are in good agreement with the experimental results. 展开更多
关键词 reinforced concrete two-way slab strengtheningmethod carbon fiber-reinforced polymer cfrp)-steel grid load-carrying capacity DEFLECTION yield-line
下载PDF
医院应急建筑与特殊结构用碳纤维复合材料的性能研究 被引量:1
3
作者 王姣 赵立华 《粘接》 CAS 2023年第7期167-170,共4页
基于医院基建工程中项目质量管控的需要,研究了医院基建用碳纤维增强复合材料(CFRP)/钢复合结构在静载剪切作用下的应力应变曲线,并考察了电偶腐蚀和非对称疲劳对CFRP/钢试件承载能力和断裂模式的影响。结果表明,在电偶腐蚀和疲劳条件下... 基于医院基建工程中项目质量管控的需要,研究了医院基建用碳纤维增强复合材料(CFRP)/钢复合结构在静载剪切作用下的应力应变曲线,并考察了电偶腐蚀和非对称疲劳对CFRP/钢试件承载能力和断裂模式的影响。结果表明,在电偶腐蚀和疲劳条件下,粘接层中含有芳纶纤维和不含芳纶纤维试件的载荷-位移曲线与无腐蚀+无疲劳试件相似;相较于不含芳纶纤维的试件,无腐蚀+无疲劳、腐蚀和疲劳试件的峰值荷载都相对含有芳纶纤维试件较大。无腐蚀+无疲劳条件下含有芳纶纤维和不含芳纶纤维试件的平均峰值荷载都高于腐蚀和疲劳条件下试件,且含有芳纶纤维的平均峰值荷载都高于不含芳纶纤维试件,腐蚀或者疲劳时间越长,则对应试件的平均峰值荷载越小。 展开更多
关键词 医院基建 cfrp/钢 腐蚀 疲劳 粘接性能
下载PDF