The subcooled water flow boiling is beneficial for removing the high heat flux from the divertor in the fusion reactor,for which an accurate critical heat flux(CHF)correlation is necessary.Up to now,there are many CHF...The subcooled water flow boiling is beneficial for removing the high heat flux from the divertor in the fusion reactor,for which an accurate critical heat flux(CHF)correlation is necessary.Up to now,there are many CHF correlations mentioned for subcooled water flow boiling in the open literatures.However,the CHF correlations’accuracies for the prediction of subcooled water flow boiling are not satisfactory at high heat flux and high pressure for reactor divertor.The present paper compiled 1356 CHF experimental data points from 15 independent open literatures and evaluated 10 existing CHF correlations in subcooled water flow boiling.From the evaluation,the W-2 CHF correlation performs best for the experimental CHF data in all existing critical heat flux correlations.However,the predicted mean absolute error(MAE)of the W-2 correlation is not very ideal for all database and the MAE of the W-2 correlation is from 30%to 50%for some database.In order to enhance the CHF prediction accuracy in subcooled water flow boiling at high heat flux and high pressure,the present paper developed a new CHF correlation.Compared with other existing CHF correlations,the new CHF correlation greatly enhances the prediction accuracy over a broad range of pressures and heat fluxes which are desired in the cooling of high heat flux devices,such as those in the fusion reactor divertor.The validation results show that the new correlation has a MAE of 10.05%and a root mean squared error(RMSE)of 16.61%,predicting 68.1%of the entire database within±10%and 81.5%within±15%.The MAE of the new CHF correlation is 7.4%less than that of the best existing one(W-2 correlation),further confirming its superior prediction accuracy and reliability.Besides,the new CHF correlation works well not only for a uniform power profile but also for a non-uniform power profile in subcooled water flow boiling at high pressure and high heat flux.展开更多
High heat dissipation is required for miniaturization and increasing the power of electronic systems.Pool boiling is a promising option for achieving efficient heat dissipation at low wall superheat without the need f...High heat dissipation is required for miniaturization and increasing the power of electronic systems.Pool boiling is a promising option for achieving efficient heat dissipation at low wall superheat without the need for moving parts.Many studies have focused on improving heat transfer efficiency during boiling by modifying the surface of the heating element.This paper presents an experimental investigation on improving pool boiling heat transfer using an open microchannel.The primary goal of this work is to investigate the impact of the channel geometry characteristics on boiling heat transfer.Initially,rectangular microchannels were prepared on a circular copper test piece with a diameter of 20 mm.Then,the boiling characteristics of these microchannels were compared with those of a smooth surface under saturated conditions using deionized water.In this investigation,a wire-cutting electrical discharge machine(EDM)machine was used to produce parallel microchannels with channel widths of 0.2,0.4,and 0.8 mm.The fin thicknesses were 0.2,0.4,and 0.6 mm,while the channel depth remained constant at 0.4 mm.The results manifested that the surface featuring narrower fins and broader channels achieved superior performance.The heat transfer coefficient(HTC)was enhanced by a maximum of 248%,and the critical heat flux(CHF)was enhanced by a maximum of 101%compared to a plain surface.Eventually,the obtained results were compared with previous research and elucidated a good agreement.展开更多
Gas-liquid two-phase flow and heat transfer can be encountered in numerous fields, such as chemical engineering, refrigeration, nuclear power reactor, metallurgical industry, spaceflight. Its critical heat flux (CHF) ...Gas-liquid two-phase flow and heat transfer can be encountered in numerous fields, such as chemical engineering, refrigeration, nuclear power reactor, metallurgical industry, spaceflight. Its critical heat flux (CHF) is one of the most important factors for the system security of engineering applications. Since annular flow is the most common flow pattern in gas-liquid two-phase flow, predicting CHF of annular two-phase flow is more significant. Many studies have shown that the liquid film dryout model is successful for that prediction, and determining the following parameters will exert predominant effects on the accuracy of this model: onset of annular flow, inception criterion for droplets entrainment, entrainment fraction, droplets deposition and entrainment rates. The main theoretical results achieved on the above five parameters are reviewed; also, limitations in the existing studies and problems for further research are discussed.展开更多
基金supported by National Natural Science Foundation of China(Grant No.11805005)National Natural Science Foundation of China(Grant No.11705234)+4 种基金Visiting and Research Project at Home and Abroad for Outstanding Youth Talents of Anhui Province University(Grant No.gxgwfx2018024)National Magnetic Confinement Fusion Science Program of China(Grant No.2014GB101001)Key University Science Research Project of Anhui Province(Grant No.KJ2018A0080)Key project of excellent young talent support program of Anhui Province of China(Grant No.gxyq ZD2016087)Provincial Natural Science Foundation of Anhui(Grant No.1608085ME89)。
文摘The subcooled water flow boiling is beneficial for removing the high heat flux from the divertor in the fusion reactor,for which an accurate critical heat flux(CHF)correlation is necessary.Up to now,there are many CHF correlations mentioned for subcooled water flow boiling in the open literatures.However,the CHF correlations’accuracies for the prediction of subcooled water flow boiling are not satisfactory at high heat flux and high pressure for reactor divertor.The present paper compiled 1356 CHF experimental data points from 15 independent open literatures and evaluated 10 existing CHF correlations in subcooled water flow boiling.From the evaluation,the W-2 CHF correlation performs best for the experimental CHF data in all existing critical heat flux correlations.However,the predicted mean absolute error(MAE)of the W-2 correlation is not very ideal for all database and the MAE of the W-2 correlation is from 30%to 50%for some database.In order to enhance the CHF prediction accuracy in subcooled water flow boiling at high heat flux and high pressure,the present paper developed a new CHF correlation.Compared with other existing CHF correlations,the new CHF correlation greatly enhances the prediction accuracy over a broad range of pressures and heat fluxes which are desired in the cooling of high heat flux devices,such as those in the fusion reactor divertor.The validation results show that the new correlation has a MAE of 10.05%and a root mean squared error(RMSE)of 16.61%,predicting 68.1%of the entire database within±10%and 81.5%within±15%.The MAE of the new CHF correlation is 7.4%less than that of the best existing one(W-2 correlation),further confirming its superior prediction accuracy and reliability.Besides,the new CHF correlation works well not only for a uniform power profile but also for a non-uniform power profile in subcooled water flow boiling at high pressure and high heat flux.
文摘High heat dissipation is required for miniaturization and increasing the power of electronic systems.Pool boiling is a promising option for achieving efficient heat dissipation at low wall superheat without the need for moving parts.Many studies have focused on improving heat transfer efficiency during boiling by modifying the surface of the heating element.This paper presents an experimental investigation on improving pool boiling heat transfer using an open microchannel.The primary goal of this work is to investigate the impact of the channel geometry characteristics on boiling heat transfer.Initially,rectangular microchannels were prepared on a circular copper test piece with a diameter of 20 mm.Then,the boiling characteristics of these microchannels were compared with those of a smooth surface under saturated conditions using deionized water.In this investigation,a wire-cutting electrical discharge machine(EDM)machine was used to produce parallel microchannels with channel widths of 0.2,0.4,and 0.8 mm.The fin thicknesses were 0.2,0.4,and 0.6 mm,while the channel depth remained constant at 0.4 mm.The results manifested that the surface featuring narrower fins and broader channels achieved superior performance.The heat transfer coefficient(HTC)was enhanced by a maximum of 248%,and the critical heat flux(CHF)was enhanced by a maximum of 101%compared to a plain surface.Eventually,the obtained results were compared with previous research and elucidated a good agreement.
基金Project (No. 2006C24G2010027) supported by the Science and Technology Department of Zhejiang Province, China
文摘Gas-liquid two-phase flow and heat transfer can be encountered in numerous fields, such as chemical engineering, refrigeration, nuclear power reactor, metallurgical industry, spaceflight. Its critical heat flux (CHF) is one of the most important factors for the system security of engineering applications. Since annular flow is the most common flow pattern in gas-liquid two-phase flow, predicting CHF of annular two-phase flow is more significant. Many studies have shown that the liquid film dryout model is successful for that prediction, and determining the following parameters will exert predominant effects on the accuracy of this model: onset of annular flow, inception criterion for droplets entrainment, entrainment fraction, droplets deposition and entrainment rates. The main theoretical results achieved on the above five parameters are reviewed; also, limitations in the existing studies and problems for further research are discussed.