A cable-in-conduit conductor(CICC ) production line was designed and constructed in Institute of Plasma Physics of Chinese Academy of Sciences (IPPCAS) by the end of 2000. It can produce a length of 600 meters and thr...A cable-in-conduit conductor(CICC ) production line was designed and constructed in Institute of Plasma Physics of Chinese Academy of Sciences (IPPCAS) by the end of 2000. It can produce a length of 600 meters and three kinds of sections of 20.8±0. 1×20.8±0.1, 20.4±0. 1×20.4± 0.1 and 18.6±0.1×18.6±0.1mm2. If the rollers of the shaping machine are changed, it can also produce other sizes of CICCs. So-called inserting-cable technology is adopted in this production line, where the procedures consist of tube pre-treatment (cleaning, pressure and leakage testing, end cutting), conduits butt-welding, six kinds of quality checking (endoscopy, dye penetration, pressure control, leakage testing, ultrasonic inspection and X-ray testing), cable inserting, shaping (compacting & squaring), pre-bending & winding and final checking. Now all the instruments and facilities required for these technologies have been installed and got ready. Some key technologies have been explored and good results obtained. Some short samples were produced and a 600 meters long sample was made out in August, 2001.展开更多
Conductor qualification will be carried out with four Cable-in-Conduit Conductor (CICC) samples made of superconducting strands. The direct current (DC) performance of these samples will be tested in the SULTAN fa...Conductor qualification will be carried out with four Cable-in-Conduit Conductor (CICC) samples made of superconducting strands. The direct current (DC) performance of these samples will be tested in the SULTAN facility. The critical current densities of the strands can be well simulated by empirical equations. In this paper, a model is illustrated to predict the DC behaviour of the cable in light of the single strand's experimental properties. The simulation results were compared with experimental results.展开更多
Cable-in-conduit conductor (CICC) conductor sample of the PF2 coil for ITER was tested in the SULTAN facility. According to the test results, the CICC conductor sample exhibited a stable performance regarding the cu...Cable-in-conduit conductor (CICC) conductor sample of the PF2 coil for ITER was tested in the SULTAN facility. According to the test results, the CICC conductor sample exhibited a stable performance regarding the current sharing temperature. Under the typical operational conditions of a current of 45 kA, a magnetic field of 4 T and a temperature of 5 K for PF2, the test result for the conductor current sharing temperature is 6.71 K, with a temperature margin of 1.71 K. For a comparison thermal-hydraulic analysis of the PF2 conductor was carried out using GANDALF code in a 1-D model, and the result is consistent with the test one.展开更多
The superconducting joint of the NbTi Cable-in -conduit Conductor (CICC) has been developed and tested on the magnet test facility at Institute of Plasma Physics, Chinese Academy of Sciences. The CICC is composed of (...The superconducting joint of the NbTi Cable-in -conduit Conductor (CICC) has been developed and tested on the magnet test facility at Institute of Plasma Physics, Chinese Academy of Sciences. The CICC is composed of (2NbTi+lCu)x3x3x(6+ltube) strands each with 0.85 mm in diameter, which has been developed for a central solenoid model coil. The effective length of the joint is about 500 mm. There have been two common fabrication modes, one of them is to integrate the 2 CICC terminals with the copper substrate via lead-soldering, and the other is to mechanically compress the above two parts into an integrated unit. In the current range from 2 kA to 10 kA the joint resistance changes slightly. Up to now, 11 TF magnets, a central solenoid model coil, a central solenoid prototype coil, and a large PF model coil of PF large coil have been completed via the latter joint in the test facility.展开更多
The CICC (cable-in-conduit conductor) in ITER (International Thermal-nuclear Experimental Reactor) will run in high-current, fast transient magnet field and complex environment. In response to the impact of magnet fie...The CICC (cable-in-conduit conductor) in ITER (International Thermal-nuclear Experimental Reactor) will run in high-current, fast transient magnet field and complex environment. In response to the impact of magnet fields above 10 T, the Nb3Sn conductor has been introduced. However, the AC (alternating current) loss mechanism of Nb3Sn conductor on strain has not been explored. So, it is necessary to study the AC loss calculation method with transient electromagnetic field and wide range of strain, the coupling current in complex field and current signal of field is simplified to the spectrum effects of coil excitation, and calculation technology of AC loss, which contains the frequency, magnet field, coil characteristics and other parameters, is constructed to meet the discrete Fourier transform (DFT). By comparative analysis of simulation, it is found that the AC loss calculation of the conductor with spectrum algorithm is closer to the actual project value than the traditional algorithm. For the rapid excitation, in particular plasma discharge and burst, spectrum algorithm and the traditional algorithm are consistent. For the relative error calculation of hysteresis loss and coupling loss, it is found that the coupling loss is cumulative linearly, where the hysteresis loss is not so. As a function of the amplitude, frequency and phase angle, the relative error is less than 40%. The results showed that the method of Fourier restructuring is satisfactory.展开更多
文摘A cable-in-conduit conductor(CICC ) production line was designed and constructed in Institute of Plasma Physics of Chinese Academy of Sciences (IPPCAS) by the end of 2000. It can produce a length of 600 meters and three kinds of sections of 20.8±0. 1×20.8±0.1, 20.4±0. 1×20.4± 0.1 and 18.6±0.1×18.6±0.1mm2. If the rollers of the shaping machine are changed, it can also produce other sizes of CICCs. So-called inserting-cable technology is adopted in this production line, where the procedures consist of tube pre-treatment (cleaning, pressure and leakage testing, end cutting), conduits butt-welding, six kinds of quality checking (endoscopy, dye penetration, pressure control, leakage testing, ultrasonic inspection and X-ray testing), cable inserting, shaping (compacting & squaring), pre-bending & winding and final checking. Now all the instruments and facilities required for these technologies have been installed and got ready. Some key technologies have been explored and good results obtained. Some short samples were produced and a 600 meters long sample was made out in August, 2001.
基金supported by the National Basic Research Program of China (No.151J00035602)
文摘Conductor qualification will be carried out with four Cable-in-Conduit Conductor (CICC) samples made of superconducting strands. The direct current (DC) performance of these samples will be tested in the SULTAN facility. The critical current densities of the strands can be well simulated by empirical equations. In this paper, a model is illustrated to predict the DC behaviour of the cable in light of the single strand's experimental properties. The simulation results were compared with experimental results.
基金supported by the Priority Base Research Development Project of China (No. 0559730532)
文摘Cable-in-conduit conductor (CICC) conductor sample of the PF2 coil for ITER was tested in the SULTAN facility. According to the test results, the CICC conductor sample exhibited a stable performance regarding the current sharing temperature. Under the typical operational conditions of a current of 45 kA, a magnetic field of 4 T and a temperature of 5 K for PF2, the test result for the conductor current sharing temperature is 6.71 K, with a temperature margin of 1.71 K. For a comparison thermal-hydraulic analysis of the PF2 conductor was carried out using GANDALF code in a 1-D model, and the result is consistent with the test one.
文摘The superconducting joint of the NbTi Cable-in -conduit Conductor (CICC) has been developed and tested on the magnet test facility at Institute of Plasma Physics, Chinese Academy of Sciences. The CICC is composed of (2NbTi+lCu)x3x3x(6+ltube) strands each with 0.85 mm in diameter, which has been developed for a central solenoid model coil. The effective length of the joint is about 500 mm. There have been two common fabrication modes, one of them is to integrate the 2 CICC terminals with the copper substrate via lead-soldering, and the other is to mechanically compress the above two parts into an integrated unit. In the current range from 2 kA to 10 kA the joint resistance changes slightly. Up to now, 11 TF magnets, a central solenoid model coil, a central solenoid prototype coil, and a large PF model coil of PF large coil have been completed via the latter joint in the test facility.
基金supported by the Major International (Regional) Joint Research Program of China (Grant No. 2004CB720704) the Excellent Young Teachers Program for Higher Education of Henan Province (Grant No. 2010GGJS-088)
文摘The CICC (cable-in-conduit conductor) in ITER (International Thermal-nuclear Experimental Reactor) will run in high-current, fast transient magnet field and complex environment. In response to the impact of magnet fields above 10 T, the Nb3Sn conductor has been introduced. However, the AC (alternating current) loss mechanism of Nb3Sn conductor on strain has not been explored. So, it is necessary to study the AC loss calculation method with transient electromagnetic field and wide range of strain, the coupling current in complex field and current signal of field is simplified to the spectrum effects of coil excitation, and calculation technology of AC loss, which contains the frequency, magnet field, coil characteristics and other parameters, is constructed to meet the discrete Fourier transform (DFT). By comparative analysis of simulation, it is found that the AC loss calculation of the conductor with spectrum algorithm is closer to the actual project value than the traditional algorithm. For the rapid excitation, in particular plasma discharge and burst, spectrum algorithm and the traditional algorithm are consistent. For the relative error calculation of hysteresis loss and coupling loss, it is found that the coupling loss is cumulative linearly, where the hysteresis loss is not so. As a function of the amplitude, frequency and phase angle, the relative error is less than 40%. The results showed that the method of Fourier restructuring is satisfactory.