Thunderstorms of pre-monsoon season (April – May) over Kolkata (22° 32’N, 88° 20’E), India are invariably accompanied with lightning flashes, high wind gusts, torrential rainfall, occasional hail and torn...Thunderstorms of pre-monsoon season (April – May) over Kolkata (22° 32’N, 88° 20’E), India are invariably accompanied with lightning flashes, high wind gusts, torrential rainfall, occasional hail and tornadoes which significantly affect the life and property on the ground and aviation aloft. The societal and economic impact due to such storms made accurate prediction of the weather phenomenon a serious concern for the meteorologists of India. The initiation of such storms requires sufficient moisture in lower troposphere, high surface temperature, conditional instability and a source of lift to initiate the convection. Convective available potential energy (CAPE) is a measure of the energy realized when conditional instability is released. It plays an important role in meso-scale convective systems. Convective inhibition energy (CINE) on the other hand acts as a possible barrier to the release of convection even in the presence of high value of CAPE. The main idea of the present study is to see whether a consistent quantitative range of CAPE and CINE can be identified for the prevalence of such thunderstorms that may aid in operational forecast. A statistical – fuzzy coupled method is implemented for the purpose. The result reveals that a definite range of CINE within 0 – 150 Jkg-1 is reasonably pertinent whereas no such range of CAPE depicts any consistency for the occurrence of severe thunderstorms over Kolkata. The measure of CINE mainly depends upon the altitude of the level of free convection (LFC), surface temperature (T) and surface mixing ratio (q). The box-and-whisker plot of LFC, T and q are drawn to select the most dependable parameter for the consistency of CINE in the prevalence of such thunderstorms. The skills of the parameters are evaluated through skill score analyses. The percentage error during validation with the observation of 2010 is estimated to be 0% for the range of CINE and 3.9% for CAPE.展开更多
9月22日,索尼中国专业系统集团在北京AIT索尼影像技术学院隆重举行Cine Alta V电影摄影机发布会,作为索尼Cine Alta摄影机系统的新一代产品,同时也是影视行业的第一款采用全画幅CMOS(36.2×24.1mm)的摄影机,Cine Alta V面世的消息...9月22日,索尼中国专业系统集团在北京AIT索尼影像技术学院隆重举行Cine Alta V电影摄影机发布会,作为索尼Cine Alta摄影机系统的新一代产品,同时也是影视行业的第一款采用全画幅CMOS(36.2×24.1mm)的摄影机,Cine Alta V面世的消息自9月发布以来便引发了影视行业用户持续的关注和讨论。发布会上,索尼专家和产品经理详解其性能优势、研发背景和多项突破性的"业界第一",并与媒体、业界用户以现场问答、网络直播的方式进行互动,力求全面、精确、展开更多
Background: Recently faster cardiac magnetic resonance (CMR) cine sequences basing on k-t compressed sensing have been developed. Purpose: To compare two compressed sensing CMR sequences-one in breath-hold technique a...Background: Recently faster cardiac magnetic resonance (CMR) cine sequences basing on k-t compressed sensing have been developed. Purpose: To compare two compressed sensing CMR sequences-one in breath-hold technique and one during free breathing—with the standard SSFP sequence with respect to regional left ventricular function assessment. Material and Methods: Left ventricular short-axis stacks of two compressed sensing sequences in breath-hold technique (sparse_HB) and during free breathing (sparse_FB;both spatial resolution, 1.8 × 1.8 × 8 mm3) and a standard SSFP cine sequence (spatial resolution, 1.9 × 1.9 × 8 mm3) were acquired in 50 patients on a 1.5 T MR system. Regional wall motion abnormalities (RWMA) were rated qualitatively (normal/hypo-/a-/dyskinesia) by two experienced readers in consensus for all cardiac segments (American Heart Association’s segment model) and sequences. RWMA detection rates were compared between sequences by kappa statistic. Results: In 13 patients, RWMA were detected in at least one cardiac segment. The RWMA detection rates were similar between CMR sequences (hypokinesia, 7.2% to 7.9%;akinesia, 0.8% to 1.3%;dyskinesia 0.3% to 0.4%) and kappa statistics revealed an almost perfect agreement in RWMA detection between both sparse and the standard SSFP sequence (standard versus sparse_HB: kappa, 0.918, p value, p value, Conclusion: Compressed sensing cine CMR acquired during breath-hold or free-breathing allows reliable RWMA detection, thus, might alternatively be used in cine CMR for regional left ventricular function assessment.展开更多
文摘Thunderstorms of pre-monsoon season (April – May) over Kolkata (22° 32’N, 88° 20’E), India are invariably accompanied with lightning flashes, high wind gusts, torrential rainfall, occasional hail and tornadoes which significantly affect the life and property on the ground and aviation aloft. The societal and economic impact due to such storms made accurate prediction of the weather phenomenon a serious concern for the meteorologists of India. The initiation of such storms requires sufficient moisture in lower troposphere, high surface temperature, conditional instability and a source of lift to initiate the convection. Convective available potential energy (CAPE) is a measure of the energy realized when conditional instability is released. It plays an important role in meso-scale convective systems. Convective inhibition energy (CINE) on the other hand acts as a possible barrier to the release of convection even in the presence of high value of CAPE. The main idea of the present study is to see whether a consistent quantitative range of CAPE and CINE can be identified for the prevalence of such thunderstorms that may aid in operational forecast. A statistical – fuzzy coupled method is implemented for the purpose. The result reveals that a definite range of CINE within 0 – 150 Jkg-1 is reasonably pertinent whereas no such range of CAPE depicts any consistency for the occurrence of severe thunderstorms over Kolkata. The measure of CINE mainly depends upon the altitude of the level of free convection (LFC), surface temperature (T) and surface mixing ratio (q). The box-and-whisker plot of LFC, T and q are drawn to select the most dependable parameter for the consistency of CINE in the prevalence of such thunderstorms. The skills of the parameters are evaluated through skill score analyses. The percentage error during validation with the observation of 2010 is estimated to be 0% for the range of CINE and 3.9% for CAPE.
文摘9月22日,索尼中国专业系统集团在北京AIT索尼影像技术学院隆重举行Cine Alta V电影摄影机发布会,作为索尼Cine Alta摄影机系统的新一代产品,同时也是影视行业的第一款采用全画幅CMOS(36.2×24.1mm)的摄影机,Cine Alta V面世的消息自9月发布以来便引发了影视行业用户持续的关注和讨论。发布会上,索尼专家和产品经理详解其性能优势、研发背景和多项突破性的"业界第一",并与媒体、业界用户以现场问答、网络直播的方式进行互动,力求全面、精确、
文摘Background: Recently faster cardiac magnetic resonance (CMR) cine sequences basing on k-t compressed sensing have been developed. Purpose: To compare two compressed sensing CMR sequences-one in breath-hold technique and one during free breathing—with the standard SSFP sequence with respect to regional left ventricular function assessment. Material and Methods: Left ventricular short-axis stacks of two compressed sensing sequences in breath-hold technique (sparse_HB) and during free breathing (sparse_FB;both spatial resolution, 1.8 × 1.8 × 8 mm3) and a standard SSFP cine sequence (spatial resolution, 1.9 × 1.9 × 8 mm3) were acquired in 50 patients on a 1.5 T MR system. Regional wall motion abnormalities (RWMA) were rated qualitatively (normal/hypo-/a-/dyskinesia) by two experienced readers in consensus for all cardiac segments (American Heart Association’s segment model) and sequences. RWMA detection rates were compared between sequences by kappa statistic. Results: In 13 patients, RWMA were detected in at least one cardiac segment. The RWMA detection rates were similar between CMR sequences (hypokinesia, 7.2% to 7.9%;akinesia, 0.8% to 1.3%;dyskinesia 0.3% to 0.4%) and kappa statistics revealed an almost perfect agreement in RWMA detection between both sparse and the standard SSFP sequence (standard versus sparse_HB: kappa, 0.918, p value, p value, Conclusion: Compressed sensing cine CMR acquired during breath-hold or free-breathing allows reliable RWMA detection, thus, might alternatively be used in cine CMR for regional left ventricular function assessment.