Based on the Chinese thermal coal and power generation data,such as ultimate analysis,proximate analysis,low heat value(LHV)on as received basis,power generation volume,thermal coal consumption volume and net coal con...Based on the Chinese thermal coal and power generation data,such as ultimate analysis,proximate analysis,low heat value(LHV)on as received basis,power generation volume,thermal coal consumption volume and net coal consumption rate,several mathematical models for calculating CO 2 reduction by Chinese coal-fired power plants are established.Calculations of the CO 2 emission factor(CEF),the CO 2 emission volume and reduction volume are made according to these models.The calculation results reveal that between 1993 and 2010,the CO 2 emission volume reached 31.069 Gt,reduced by 0.439 Gt,averaging 28.83 Mt each year.展开更多
Carbon emissions from forest fires are considered an important factor of ecosystem carbon balance and global climate change. Carbon emissions from Japanese red pine stands (Pinus densiflora S. et Z.) burned by crown...Carbon emissions from forest fires are considered an important factor of ecosystem carbon balance and global climate change. Carbon emissions from Japanese red pine stands (Pinus densiflora S. et Z.) burned by crown fire were estimated at Mt. Palgong in Daegu Metropolitan City, and crown fuel characteristics, including crown bulk density, crown base height, and fuel moisture content of Japanese red pine, were analyzed. Total biomass combusted was calculated by subtracting the biomass of burned stands from that of unburned stands exhibiting similar stand structures and site environments. Ten trees in the unburned area and five trees in the burned area were cut by using direct harvesting techniques to estimate crown layer biomass. All biomass sampled was oven-dried and weighed. The dry weight ratios of stems, branches, and needles were 7o%, 21%, and 9%, respectively. The available fuel load susceptible to combustion during the crown fire spread was equivalent to 55% of the crown layer biomass. The crown bulk density was 0.24 kg/m3 on average. The estimated amount of CO2 was 23,454 kg CO2/ha for the crown layer. These results will be useful for calculating the amount of CO2 emitted from forest fires and for developing a forest carbon model in P. densiflora forests.展开更多
This is a greenhouse ecological parameters measurement and control system, the system implements the data collection of field temperature, humidity and carbon dioxide by using the 1-wire bus network which consist of 1...This is a greenhouse ecological parameters measurement and control system, the system implements the data collection of field temperature, humidity and carbon dioxide by using the 1-wire bus network which consist of 1-wire bus temperature sensor, 1-wire bus humidity sensor, Analog-to-Digital Converter(ADC), CO2 sensor and intelligent battery monitor.展开更多
文摘Based on the Chinese thermal coal and power generation data,such as ultimate analysis,proximate analysis,low heat value(LHV)on as received basis,power generation volume,thermal coal consumption volume and net coal consumption rate,several mathematical models for calculating CO 2 reduction by Chinese coal-fired power plants are established.Calculations of the CO 2 emission factor(CEF),the CO 2 emission volume and reduction volume are made according to these models.The calculation results reveal that between 1993 and 2010,the CO 2 emission volume reached 31.069 Gt,reduced by 0.439 Gt,averaging 28.83 Mt each year.
文摘Carbon emissions from forest fires are considered an important factor of ecosystem carbon balance and global climate change. Carbon emissions from Japanese red pine stands (Pinus densiflora S. et Z.) burned by crown fire were estimated at Mt. Palgong in Daegu Metropolitan City, and crown fuel characteristics, including crown bulk density, crown base height, and fuel moisture content of Japanese red pine, were analyzed. Total biomass combusted was calculated by subtracting the biomass of burned stands from that of unburned stands exhibiting similar stand structures and site environments. Ten trees in the unburned area and five trees in the burned area were cut by using direct harvesting techniques to estimate crown layer biomass. All biomass sampled was oven-dried and weighed. The dry weight ratios of stems, branches, and needles were 7o%, 21%, and 9%, respectively. The available fuel load susceptible to combustion during the crown fire spread was equivalent to 55% of the crown layer biomass. The crown bulk density was 0.24 kg/m3 on average. The estimated amount of CO2 was 23,454 kg CO2/ha for the crown layer. These results will be useful for calculating the amount of CO2 emitted from forest fires and for developing a forest carbon model in P. densiflora forests.
文摘This is a greenhouse ecological parameters measurement and control system, the system implements the data collection of field temperature, humidity and carbon dioxide by using the 1-wire bus network which consist of 1-wire bus temperature sensor, 1-wire bus humidity sensor, Analog-to-Digital Converter(ADC), CO2 sensor and intelligent battery monitor.