期刊文献+
共找到550篇文章
< 1 2 28 >
每页显示 20 50 100
The Bell Inequality Is Satisfied by Quantum Correlations Computed Consistently with Quantum Non-Commutation
1
作者 Louis Sica 《Journal of Modern Physics》 2016年第4期404-412,共9页
In constructing his theorem, Bell assumed that correlation functions among non-commuting variables are the same as those among commuting variables. However, in quantum mechanics, multiple data values exist simultaneou... In constructing his theorem, Bell assumed that correlation functions among non-commuting variables are the same as those among commuting variables. However, in quantum mechanics, multiple data values exist simultaneously for commuting operations while for non-commuting operations data are conditional on prior outcomes, or may be predicted as alternative outcomes of the non-commuting operations. Given these qualitative differences, there is no reason why correlation functions among non-commuting variables should be the same as those among commuting variables, as assumed by Bell. When data for commuting and noncommuting operations are predicted from quantum mechanics, their correlations are different, and they now satisfy the Bell inequality. 展开更多
关键词 Bell’s Theorem Bell Inequality Hidden Variables CORRELATIONS commutation Noncommutation
下载PDF
Numerical Study on Arc Plasma Behavior During Arc Commutation Process in Direct Current Circuit Breaker 被引量:37
2
作者 杨飞 马瑞光 +3 位作者 吴翊 孙昊 纽春萍 荣命哲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第2期167-171,共5页
This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker (DCCB) contact system. A three-dimensional magneto-hydrodyna... This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker (DCCB) contact system. A three-dimensional magneto-hydrodynamic (MHD) model of air arc plasma in the contact system of a DCCB is developed, based on commercial software FLUENT. Coupled electromagnetic and gas dynamic interactions are considered as usual, and a thin layer of nonlinear electrical resistance elements is used to represent the voltage drop of plasma sheath and the formation of new arc root. The distributions of pressure, temperature, gas flow and current density of arc plasma in arc region are calculated. The simulation results indicate that the pressure distribution related to the contact system has a strong effect on the arc commutation process, arising from the change of electrical conductivity in the arc root region. In DCCB contact system, the pressure of arc root region will be concentrated and higher if the space above the moving contact is enclosed, which is not good for arc root commutation. However, when the region is opened, the pressure distribution would be lower and more evenly, which is favorable for the arc root commutation. 展开更多
关键词 arc plasma DC circuit breaker arc commutation PRESSURE simulation
下载PDF
Influence of PWM Modes on Commutation Torque Ripples in Sensorless Brushless DC Motor Control System 被引量:7
3
作者 ZHANG Xiang jun, CHEN Bo shi School of Electromechanical Engineering and Automation, Shanghai University, Shanghai 200072, China 《Journal of Shanghai University(English Edition)》 CAS 2001年第3期217-223,共7页
This paper introduces four PWM modes used in the sensorless brushless DC motor control system, analyzes their different influences on the commutation torque ripple in detail, and selects the best PWM mode in four give... This paper introduces four PWM modes used in the sensorless brushless DC motor control system, analyzes their different influences on the commutation torque ripple in detail, and selects the best PWM mode in four given types to reduce commutation torque ripple of Brushless OC(BLDC) motors. Simulation and experimental results show that the selection is correct and practical. 展开更多
关键词 sensorless BLDC motors PWM modes commutation torque ripple
下载PDF
Studies of commutation failures in hybrid LCC/MMC HVDC systems 被引量:9
4
作者 Gen Li Ting An +4 位作者 Jun Liang Wei Liu Tibin Joseph Jingjing Lu Yuanliang Lan 《Global Energy Interconnection》 2020年第3期193-204,共12页
A hybrid of line commutated converters(LCCs)and modular multi-level converters(MMCs)can provide the advantages of both the technologies.However,the commutation failure still exists if the LCC operates as an inverter i... A hybrid of line commutated converters(LCCs)and modular multi-level converters(MMCs)can provide the advantages of both the technologies.However,the commutation failure still exists if the LCC operates as an inverter in a hybrid LCC/MMC system.In this paper,the system behavior during a commutation failure is investigated.Both halfbridge and full-bridge MMCs are considered.Control strategies are examined through simulations conducted in PSCAD/EMTDC.Additionally,commutation failure protection strategies for multi-terminal hybrid LCC/MMC systems with AC and DC circuit breakers are studied.This paper can contribute to the protection design of future hybrid LCC/MMC systems against commutation failures. 展开更多
关键词 LCC HVDC MMC HVDC Modular multilevel converter Hybrid LCC/MMC commutation failure multi-terminal DC Fault protection
下载PDF
A New Method for Reducing Commutation Torque Ripples in BLDC Motors 被引量:1
5
作者 ZHANG Xiang jun, CHEN Bo shi School of Electromechanical Engineering and Automation, Shanghai University, Shanghai 200072, China 《Journal of Shanghai University(English Edition)》 CAS 2001年第1期71-75,共5页
A new compensation method and an algorithm for compensating for the commutation torque ripples of the trapezoidal EMF brushless DC motor are put forward. Simulation and experimental results show that this method is co... A new compensation method and an algorithm for compensating for the commutation torque ripples of the trapezoidal EMF brushless DC motor are put forward. Simulation and experimental results show that this method is correct and practical. 展开更多
关键词 sensorless drive trapezoidal EMF brushless DC motor commutation torque ripple
下载PDF
Research of Three-Phase Unbalanced Treatment in Low-Voltage Distribution Network Based on New Commutation Switch 被引量:1
6
作者 Xue Liu Jun Jia Jian Wang 《World Journal of Engineering and Technology》 2019年第4期10-17,共8页
Low-voltage distribution systems in our country are mostly used in agricultural loads and household loads. The value and using time of these kinds of loads are uncontrollable, which lead to the three-phase imbalance i... Low-voltage distribution systems in our country are mostly used in agricultural loads and household loads. The value and using time of these kinds of loads are uncontrollable, which lead to the three-phase imbalance in low-voltage distribution system, and seriously affect the quality of power supply. A new type of the commutation system and an improved quantum genetic algorithm (IQGA) are proposed in the paper. At last, the rationality and the efficiency of the method are verified by a practical example. 展开更多
关键词 LOW-VOLTAGE DISTRIBUTION Network THREE-PHASE UNBALANCE commutation SWITCH IQGA
下载PDF
Current-Bounded Commutation of a Long-Stroke Magnetically Levitated Stage with Moving Coils
7
作者 ZHU Yu ZHANG Shengguo +2 位作者 YANG Kaiming MU Haihua YIN Wensheng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第6期1238-1244,共7页
Magnetically levitated stages(MLS) have potentials to obtain good motion performances in high vacuum environment. Yet the electromagnetic forces/torques corresponding to six degrees of freedom(DOF) motions have co... Magnetically levitated stages(MLS) have potentials to obtain good motion performances in high vacuum environment. Yet the electromagnetic forces/torques corresponding to six degrees of freedom(DOF) motions have coupling relationship with each current of coil array, and this coupling is still associated with the relative positions between the mover and the stator of the stage. So it is quite difficult to control the 6-DOF motions of the stage. By reasonable commutation of coil array, this complicated coupling relationship can be decoupled. The analytical force/torque-decomposing model of the stage is established first. Then the initial currents of coil array are commutated based on the pseudo inverse of the analytical force/torque-decomposing model matrix. And then the coil array currents are commutated again with different current bounds given to the initial currents as well as in the sense of minimum 2-norm of currents vector. Using the long stroke magnetically levitated stage with moving coils under investigation as examples, the currents of coil array are commutated with different current bounds adopting the proposed commutation method, the determination of current bound and the current bounds' influences on the heat-losses in coil array are analyzed, and the effectiveness of implementation algorithm of proposed commutation method is discussed. Simulation, analysis and discussion results indicate that the currents of coil array within the given current bound can be solved analytically by proposed commutation method, and the implementation algorithm does not need any searching or iteration. By the current-bounded commutation method proposed, the amplitude of coil array currents can be limited within an appropriate current bound(This is very beneficial to the improvement of the reliability and motion performance of the stage), as well as these currents can also generate the desired forces and torques. 展开更多
关键词 magnetic levitation current-bounded commutation current bound coil array electromagnetic forces/torques heat-loss.
下载PDF
The Influence of Contact Space on Arc Commutation Process in Air Circuit Breaker
8
作者 纽春萍 丁炬文 +3 位作者 杨飞 董得龙 荣命哲 徐丹 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第5期460-464,共5页
In this paper, a 3D magneto-hydrodynamic (MHD) arc simulation model is applied to analyze the arc motion during current interruption in a certain air circuit breaker (ACB). The distributions of pressure, temperatu... In this paper, a 3D magneto-hydrodynamic (MHD) arc simulation model is applied to analyze the arc motion during current interruption in a certain air circuit breaker (ACB). The distributions of pressure, temperature, gas flow and current density of the arc plasma in the arc region are calculated, and the factors influencing the commutation process are analyzed according to the calculated results. Based on the airflow in the arc chamber, the causes of arc commutation asynchrony and the back commutation are investigated. It indicates that a reasonable contact space design is crucial to a successful arc commutation process. To verify the simulation results, the influence of contact space on arc voltage and arc commutation is tested. This research can provide methods and references to the optimization of ACB design. 展开更多
关键词 air circuit breaker arc simulation arc commutation arc chamber
下载PDF
Analysis of Commutation Failure in Multi-Infeed HVDC System under Different Load Models
9
作者 Chengjun Xia Zhongchao Yang +1 位作者 Kun Men Yong Zhao 《Journal of Power and Energy Engineering》 2014年第9期154-161,共8页
HVDC technology has been widely used in modern power system. On one hand, HVDC has the advantages of economy, high efficiency and strong controllability. While on the other hand, it makes the dynamic characteristics o... HVDC technology has been widely used in modern power system. On one hand, HVDC has the advantages of economy, high efficiency and strong controllability. While on the other hand, it makes the dynamic characteristics of the power system becoming more and more complex. That puts forward a new challenge to system stability and raises new questions for power system simulation. This paper focuses on the interaction between AC and DC systems, especially the problem of commutation failure caused by AC system fault. Based on the data of China Southern Power Grid, this paper calculates the fault regions that may cause commutation failure and calculates the system critical clearance time under different load models, analyzes the impacts of different load models on commutation failure and the stability of AC/DC hybrid system. 展开更多
关键词 AC/DC Hybrid SYSTEM commutation Failure VOLTAGE of CONVERTER BUS Load Model Power SYSTEM Simulation
下载PDF
New two chamber transfer switch for 6500 A commutation current
10
作者 Lutz-Rüdiger Jänicke Jörg Teichmann +2 位作者 Shibani Bose Weidong Han Xiaoming Wang 《Global Energy Interconnection》 2018年第3期344-351,共8页
HVDC transfer switches are used in different locations in electrode lines of HVDC transmission systems for their reconfigurations. They have to carry and commutate currents to the overload currents of HVDC transmissio... HVDC transfer switches are used in different locations in electrode lines of HVDC transmission systems for their reconfigurations. They have to carry and commutate currents to the overload currents of HVDC transmission systems, which increased to 6,400 A in the past years. Common designs of transfer switches use combinations of several switching units connected in series and parallel. This paper describes the design and development of a new DC commutation switch with two switching units only, but it is able to carry currents up to 10,000 A and has an actual tested commutation capability of 6,500 A. 展开更多
关键词 HVDC Switch Passive resonance 6 500 A commutation current 10 000 A nominal current
下载PDF
Research on the Commutation Revocation
11
《International English Education Research》 2015年第4期81-82,共2页
In order to resist some prisoner who have received rewards of commutation to implement some illegal or criminal behavior in the course of imprisonment, the system of commutation revocation must be established, which c... In order to resist some prisoner who have received rewards of commutation to implement some illegal or criminal behavior in the course of imprisonment, the system of commutation revocation must be established, which can advantage imprisonment and reduce the costs of imprisonment. The system of commutation revocation can obey to the criminal policy of temper justice with mercy and the principle of "collecting mistakes whenever discovered" and obtain the penalty goal of special prevention. In order to protect some prisoner' s benefit, the prisoner who be revoked the rewards of commutation can take part in the course of juice, the postbox which be opened only by the NPC and committee must be installed in prison. This will be advantage of some prisoner who be revoked the rewards of commutation appealing to the NPC and committee. Because of weakness of necessarily and execution, the system of commutation revocation cannot be established when the prisoner have been released currently. 展开更多
关键词 commutation revocation Penalty change measures Insufficient punishment
下载PDF
Calculation Method for Commutation Failure Fault Level in LCC-HVDC System Under Single-line-to-ground Faults Considering DC Current Variation
12
作者 Renlong Zhu Xiaoping Zhou +4 位作者 Hanhang Yin Lerong Hong An Luo Yandong Chen Hanting Peng 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第6期1995-2002,共8页
Earlier studies have reported some calculation methods for commutation failure fault level(CFFL) in line-commutated-converter based high-voltage direct current(LCCHVDC) system under single-line-to-ground(SLG) faults. ... Earlier studies have reported some calculation methods for commutation failure fault level(CFFL) in line-commutated-converter based high-voltage direct current(LCCHVDC) system under single-line-to-ground(SLG) faults. The accuracy of earlier methods is limited because they only consider the commutating voltage drop and phase shift, while neglecting the DC current variation. Hence, this paper proposes a CFFL calculation method under SLG faults considering DC current variation, for better planning and designing of LCC-HVDC systems. First, the fault commutating voltage magnitude and phase shift are calculated. Then, the fault DC voltage during different commutation processes is deduced. Based on the commutating voltage magnitude and phase shift, and DC voltage during different commutation processes under SLG faults, the characteristics of CFFL with different fault time are demonstrated and analyzed. Next, the transient time-domain response of the DC current after the fault is obtained based on the DC transmission line model. Discrete commutation processes are constructed based on the commutation voltage-time area rule to solve the extinction angle under different fault levels and fault time. Finally, the CFFL is calculated considering the fault time, commutating voltage drop, phase shift, and DC current variation. The accuracy of the proposed method compared with the traditional method is validated based on the CIGRE benchmark model in PSCAD/EMTDC. 展开更多
关键词 commutation failure(CF) commutation failure fault level(CFFL) line-commutated-converter-based highvoltage direct current(LCC-HVDC) single-line-to-ground(SLG)fault
原文传递
An improved prediction method of subsequent commutation failure of an LCC-HVDC considering sequential control response 被引量:2
13
作者 Jinxin Ouyang Xinyu Pan +3 位作者 Junjun Ye Chao Xiao Yanbo Diao Qingwu Zhang 《Protection and Control of Modern Power Systems》 SCIE EI 2023年第3期173-183,共11页
Subsequent commutation failure(SCF)can be easily generated during the first commutation failure(CF)recovery process in a line-commutated converter-based high voltage direct-current system.SCF poses a significant threa... Subsequent commutation failure(SCF)can be easily generated during the first commutation failure(CF)recovery process in a line-commutated converter-based high voltage direct-current system.SCF poses a significant threat to the safe and stable operation of power systems,and accurate prediction of CF is thus important.However,SCF is affected by the operating characteristics of the main circuit and the coupling effects of sequential control response in the inverter station.These are difficult to predict accurately.In this paper,a new SCF prediction method considering the control response is proposed based on the physical principle of SCF.The time sequence and switching conditions of the controllers at different stages of the first CF recovery process are described,and the corresponding equations of commutation voltage affected by different controllers are derived.The calculation method of the SCF threshold voltage is proposed,and the prediction method is established.Simulations show that the proposed method can predict SCF accurately and provide useful tools to suppress SCF. 展开更多
关键词 Line-commutated converter based high-voltage direct-current(LCC-HVDC) Subsequent commutation failure(SCF) Converter station PREDICTION
原文传递
A Continuous Fault Ride-through Scheme for DFIGs Under Commutation Failures in LCC-HVDC Transmission Systems 被引量:1
14
作者 Zixuan Zheng Donghui Song +3 位作者 Kaijian Du Xianyong Xiao Jie Ren Qi Xie 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第4期1126-1135,共10页
Experimental and theoretical studies have confirmed that,relative to a one-shot voltage fault,a doubly-fed induction generator(DFIG)will suffer a greater transient impact during continuous voltage faults.This paper pr... Experimental and theoretical studies have confirmed that,relative to a one-shot voltage fault,a doubly-fed induction generator(DFIG)will suffer a greater transient impact during continuous voltage faults.This paper presents the design and application of an effective scheme for DFIGs when a commutation failure(CF)occurs in a line-commutated converter based high-voltage direct current(LCC-HVDC)transmission system.First,transient demagnetization control without filters is proposed to offset the electromotive force(EMF)induced by the natural flux and other low-frequency flux components.Then,a rotor-side integrated impedance circuit is designed to limit the rotor overcurrent to ensure that the rotor-side converter(RSC)is controllable.Furthermore,coordinated control of the demagnetization and segmented reactive currents is implemented in the RSC.Comparative studies have shown that the proposed scheme can limit rotor fault currents and effectively improve the continuous fault ride-through capability of DFIGs. 展开更多
关键词 Continuous fault commutation failure(CF) doubly-fed induction generator(DFIG) fault ride-through(FRT)capability high-voltage direct current(HVDC)
原文传递
Commutation of Geometry-Grids and Fast Discrete PDE Eigen-Solver GPA
15
作者 Jiachang SUN Jianwen CAO +1 位作者 Ya ZHANG Haitao ZHAO 《Chinese Annals of Mathematics,Series B》 SCIE CSCD 2023年第5期735-752,共18页
A geometric intrinsic pre-processing algorithm(GPA for short)for solving largescale discrete mathematical-physical PDE in 2-D and 3-D case has been presented by Sun(in 2022–2023).Different from traditional preconditi... A geometric intrinsic pre-processing algorithm(GPA for short)for solving largescale discrete mathematical-physical PDE in 2-D and 3-D case has been presented by Sun(in 2022–2023).Different from traditional preconditioning,the authors apply the intrinsic geometric invariance,the Grid matrix G and the discrete PDE mass matrix B,stiff matrix A satisfies commutative operator BG=GB and AG=GA,where G satisfies G^(m)=I,m<<dim(G).A large scale system solvers can be replaced to a more smaller block-solver as a pretreatment in real or complex domain.In this paper,the authors expand their research to 2-D and 3-D mathematical physical equations over more wide polyhedron grids such as triangle,square,tetrahedron,cube,and so on.They give the general form of pre-processing matrix,theory and numerical test of GPA.The conclusion that“the parallelism of geometric mesh pre-transformation is mainly proportional to the number of faces of polyhedron”is obtained through research,and it is further found that“commutative of grid mesh matrix and mass matrix is an important basis for the feasibility and reliability of GPA algorithm”. 展开更多
关键词 Mathematical-physical discrete eigenvalue problems Commutative operator Geometric pre-processing algorithm Eigen-polynomial factorization
原文传递
Improved Identification Method and Fault Current Limiting Strategy for Commutation Failure in LCC-HVDC 被引量:5
16
作者 Jian Liu Sheng Lin +1 位作者 Wenliang Zhong Lei Liu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第6期1761-1772,共12页
Line-commutated converter based high-voltage direct-current(LCC-HVDC)transmission systems are prone to subsequent commutation failure(SCF),which consequently leads to the forced blocking of HVDC links,affecting the op... Line-commutated converter based high-voltage direct-current(LCC-HVDC)transmission systems are prone to subsequent commutation failure(SCF),which consequently leads to the forced blocking of HVDC links,affecting the operation of the power system.An accurate commutation failure(CF)identification is fairly vital to the prevention of SCF.However,the existing CF identification methods cause CF misjudge or detection lag,which can limit the effect of SCF mitigation strategy.In addition,earlier approaches to suppress SCF do not clarify the key factor that determines the evolution of extinction angle during system recovery and neglect the influence.Hence,this paper firstly analyzes the normal commutation process and CF feature based on the evolution topology of converter valve conduction in detail.Secondly,the energy in the leakage inductance of converter transformer is presented to characterize the commutation state of the valves.Then a CF identification method is proposed utilizing the leakage inductance energy.Thirdly,taking the key variable which is crucial to the tendency of extinction angle during the recovery process into account,a fault current limiting strategy for SCF mitigation is put forward.Compared with the original methods,the proposed methods have a better performance in CF identification and mitigation in terms of detection accuracy and mitigation effect.Finally,case study on PSCAD/EMTDC validates the proposed methods. 展开更多
关键词 Line commutated converter based high-voltage direct current(LCC-HVDC)transmission commutation failure identification commutation failure mitigation HVDC transmission control
原文传递
Quantitative Assessment for Commutation Security Based on Extinction Angle Trajectory 被引量:3
17
作者 Qi Tao Yusheng Xue 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第2期328-337,共10页
In order to reduce the risk of commutation failure(CF)in the AC/DC hybrid power system,the quantitative analysis on CF is required for on-line assessment and optimal control.This paper presents an accurate and reliabl... In order to reduce the risk of commutation failure(CF)in the AC/DC hybrid power system,the quantitative analysis on CF is required for on-line assessment and optimal control.This paper presents an accurate and reliable method to quantify the commutation security based on the trajectory due to the complexity of the high-voltage direct current(HVDC)model.Firstly,the characteristics of the extinction angle trajectory are analyzed under both commutation success and failure conditions.The commutation security margin index(CSMI)is then proposed for the HVDC systems.Moreover,a search strategy for parameter limits is put forward based on the sensitivity analysis of CSMI to accelerate the search speed with a guaranteed accuracy level.A modified IEEE 39-bus power system and an actual large-scale power system with 46 generators and 821 buses are utilized to verify the validity and robustness of the proposed index and strategy. 展开更多
关键词 AC/DC hybrid power system commutation failure(CF) commutation security margin high-voltage direct current(HVDC) security limit
原文传递
Commutation Failure Mitigation Method Based on Imaginary Commutation Process 被引量:3
18
作者 Renlong Zhu Xiaoping Zhou +4 位作者 Haitao Xia Lerong Hong Hanhang Yin Lingfeng Deng Yifeng Liu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第5期1413-1422,共10页
The commutation failure(CF) mitigation effectiveness is normally restricted by the delay of extinction angle(EA)measurement or the errors of existing prediction methods for EA or firing angle(FA). For this purpose, th... The commutation failure(CF) mitigation effectiveness is normally restricted by the delay of extinction angle(EA)measurement or the errors of existing prediction methods for EA or firing angle(FA). For this purpose, this paper proposes a CF mitigation method based on the imaginary commutation process. For each sample point, an imaginary commutation process is constructed to simulate the actual commutation process.Then, the imaginary EA is calculated by comparing the imaginary supply voltage-time area and the imaginary demand voltage-time area, which can update the imaginary EA earlier than the measured EA. In addition, the proposed method considers the impacts of commutation voltage variation, DC current variation, and phase angle shift of commutation voltage on the commutation process, which can ensure a more accurate EA calculation. Moreover, the DC current prediction is proposed to improve the CF mitigation performance under the single-phase AC faults. Finally, the simulation results based on CIGRE model prove that the proposed method has a good performance in CF mitigation. 展开更多
关键词 commutation failure(CF) commutation failure mitigation extinction angle line commutated converter based high-voltage direct current(LCC-HVDC)
原文传递
Analysis on Local and Concurrent Commutation Failure of Multi-infeed HVDC Considering Inter-converter Interaction 被引量:3
19
作者 Bilawal Rehman Chongru Liu +2 位作者 Huan Li Chuang Fu Wei Wei 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第4期1050-1059,共10页
This paper provides a comprehensive analysis of local and concurrent commutation failure(CF)of multi-infeed high-voltage direct current(HVDC)system considering multi-infeed interaction factor(MIIF).The literature indi... This paper provides a comprehensive analysis of local and concurrent commutation failure(CF)of multi-infeed high-voltage direct current(HVDC)system considering multi-infeed interaction factor(MIIF).The literature indicates that the local CF is not influenced by MIIF,whereas this paper concludes that both the local CF and concurrent CF are influenced by MIIF.The ability of remote converter to work under reduced reactive power enables its feature to support local converter via inter-connection link.The MIIF measures the strength of electrical connectivity between converters.Higher MIIF gives a clearer path to remote converter to support local converter,but at the same time,it provides an easy path to local converter to disturb remote converter under local fault.The presence of nearby converter increases the local commutation failure immunity index(CFII)while reducing concurrent CFII.Higher MIIF causes reactive power support to flow from remote converter to local converter,which reduces the chances of CF.A mathematical approximation to calculate the increase in local CFII for multi-infeed HVDC configurations is also proposed.A power flow approach is used to model the relation between MIIF and reactive power support from remote end.The local and concurrent CFIIs are found to be inverse to each other over MIIF;therefore,it is recommended that there is an optimal value of MIIF for all converters in close electric proximity to maintain CFII at a certain level.The numerical results of established model are compared with PSCAD/EMTDC simulations.The simulation results show the details of the influence of MIIF on local CF and concurrent CF of multi-infeed HVDC,which validates the analysis presented. 展开更多
关键词 commutation failure(CF) multi-infeed highvoltage direct current(HVDC)system multi-infeed interaction factor commutation failure immunity index(CFII)
原文传递
A Commutation Failure Prediction and Mitigation Method 被引量:2
20
作者 Renlong Zhu Xiaoping Zhou +2 位作者 Haitao Xia Lerong Hong Hanhang Yin 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第3期779-787,共9页
The mitigation of commutation failure(CF)depends on the accuracy of CF prediction.In terms of the large error of the existing extinction angle(EA)calculation during the fault transient period,a method for CF predictio... The mitigation of commutation failure(CF)depends on the accuracy of CF prediction.In terms of the large error of the existing extinction angle(EA)calculation during the fault transient period,a method for CF prediction and mitigation is proposed.Variations in both DC current and overlap angle(OA)are considered in the proposed method to predict the EA rapidly.In addition,variations in critical EA and the effect of firing angle(FA)on both DC current and OA are considered in the proposed method to obtain the accurate FA order for the control system.The proposed method can achieve good performance in terms of CF mitigation and reduce reactive consumption at the inverter side when a fault occurs.Simulation results based on the PSCAD/EMTDC show that the proposed method predicts CF rapidly and exhibits good performance in terms of CF mitigation. 展开更多
关键词 commutation failure prediction commutation failure mitigation line commutated converter based high-voltage direct current(LCC-HVDC) extinction angle(EA) overlap angle(OA) firing angle(FA)
原文传递
上一页 1 2 28 下一页 到第
使用帮助 返回顶部