The pollution of aquatic ecosystem by heavy metals has assumed serious proportions due to their toxicity and accumulative behavior. The toxicity metal is dependent on its chemical form and therefore removal of metal i...The pollution of aquatic ecosystem by heavy metals has assumed serious proportions due to their toxicity and accumulative behavior. The toxicity metal is dependent on its chemical form and therefore removal of metal is more meaningful than the estimation of its concentrations. In this study, the batch experiments were carried out under 30℃ to study the effect of pH, initial Cr concentration, adsorbent dose and contact time on the removal of Cr (lII). The maximum adsorption efficiency (99%) was observed when 1.5 g of pond mud was used for removal ofCr (Ⅲ) from test solution containing 150 mg·Cr / 100 ml. The optimal pH and contact time recorded during the study were 6 and 10.0, respectively.展开更多
With the constantly changing engineering construction sector,the detection accuracy of conventional electrical resistivity tomography(ERT)is no longer suffi cient.A multichannel electrode design(MERT)-based ERT is int...With the constantly changing engineering construction sector,the detection accuracy of conventional electrical resistivity tomography(ERT)is no longer suffi cient.A multichannel electrode design(MERT)-based ERT is introduced in this paper to address the growing need for resolution.The imaging accuracy of the ERT method is improved through the collection of apparent resistivity data in various directions by measuring the potential diff erence between diff erent channels.Numerical simulation results of the inclined high-resistivity anomaly model reveal that MERT is a precise representation of the shape,inclined direction,and buried depth of the anomaly,with thoroughfare M2N2 producing the most precise forward and inverse results.Based on the analysis results of the model resolution matrix,when the buried depth of power supply points and the gap between potential acquisition points are 30%-90%and 30%-60%of the electrode distance,respectively,the MERT approach yields superior detection outcomes.The detection eff ect of the MERT method on anomalous bodies with diff erent burial depths under the optimal parameters also indicates that the MERT method can obtain richer potential change information with higher resolution in deep areas compared to the ERT method.With the implementation of the MERT approach,the scope of applications for ERT is expanded,the accuracy of ERT detection is increased,and the progress of near-surface fi ne detection is positively infl uenced.展开更多
文摘The pollution of aquatic ecosystem by heavy metals has assumed serious proportions due to their toxicity and accumulative behavior. The toxicity metal is dependent on its chemical form and therefore removal of metal is more meaningful than the estimation of its concentrations. In this study, the batch experiments were carried out under 30℃ to study the effect of pH, initial Cr concentration, adsorbent dose and contact time on the removal of Cr (lII). The maximum adsorption efficiency (99%) was observed when 1.5 g of pond mud was used for removal ofCr (Ⅲ) from test solution containing 150 mg·Cr / 100 ml. The optimal pH and contact time recorded during the study were 6 and 10.0, respectively.
基金supported by the National Key Research and Development Program of China(Grant No.2021YFC3000103)the National Natural Science Foundation of China(Grant No.41504081)。
文摘With the constantly changing engineering construction sector,the detection accuracy of conventional electrical resistivity tomography(ERT)is no longer suffi cient.A multichannel electrode design(MERT)-based ERT is introduced in this paper to address the growing need for resolution.The imaging accuracy of the ERT method is improved through the collection of apparent resistivity data in various directions by measuring the potential diff erence between diff erent channels.Numerical simulation results of the inclined high-resistivity anomaly model reveal that MERT is a precise representation of the shape,inclined direction,and buried depth of the anomaly,with thoroughfare M2N2 producing the most precise forward and inverse results.Based on the analysis results of the model resolution matrix,when the buried depth of power supply points and the gap between potential acquisition points are 30%-90%and 30%-60%of the electrode distance,respectively,the MERT approach yields superior detection outcomes.The detection eff ect of the MERT method on anomalous bodies with diff erent burial depths under the optimal parameters also indicates that the MERT method can obtain richer potential change information with higher resolution in deep areas compared to the ERT method.With the implementation of the MERT approach,the scope of applications for ERT is expanded,the accuracy of ERT detection is increased,and the progress of near-surface fi ne detection is positively infl uenced.