It is of particular interest to investigate nuclear fusion reactions generated by high-intensity lasers in plasma environments that are similar to real astrophysical conditions.We have experimentally investigated2H(d,...It is of particular interest to investigate nuclear fusion reactions generated by high-intensity lasers in plasma environments that are similar to real astrophysical conditions.We have experimentally investigated2H(d,p)3H,one of the most crucial reactions in big bang nucleosynthesis models,at the Shenguang-Ⅱlaser facility.In this work,we present a new calibration of CR-39 solidstate track detectors,which are widely employed as the main diagnostics in this type of fusion reaction experiment.We measure the dependence of the track diameter on the proton energy.It is found that the track diameters of protons with different energies are likely to be identical.We propose that in this case,the energy of the reaction products can be obtained by considering both the diameters and gray levels of these tracks.The present results would be very helpful for analyzing the2 H(d,p)3H reaction products recorded with the same batch of CR-39 solid-state track detectors.展开更多
In this work, a simple and accurate method for U and Th determination in natural samples is proposed. This method is based on simplified calculations of the efficiency factor of the solid state track detector using a ...In this work, a simple and accurate method for U and Th determination in natural samples is proposed. This method is based on simplified calculations of the efficiency factor of the solid state track detector using a thin source approach. Samples were firstly saluted using a concentrated H2SO4 acid and then distributed on a glassy slide where the thickness of the sample was about 7 μm. CR-39 and LR-115 track detectors were exposed to the thin layer of the natural samples for few days and then the track densities were obtained. By the mean of originated track densities in CR-39 and LR-115 as a function of exposure time and sample weight, the concentration of U and Th in Bq/kg were obtained by the thin source approach of SSNTD.展开更多
Charged particle diagnosis is an important aspect of laser–plasma experiments conducted at super-intense laser facilities. In recent years, Columbia Resin #39 (CR- 39) detectors have been widely employed for detectin...Charged particle diagnosis is an important aspect of laser–plasma experiments conducted at super-intense laser facilities. In recent years, Columbia Resin #39 (CR- 39) detectors have been widely employed for detecting charged particles in laser–plasma experiments. This is because the CR-39 polymer does not respond to electromagnetic pulses or X-rays. This study presents a method for calibrating the relationship between particle energy and track diameter in a CR-39 detector (TasTrak■) using 3-8 MeV protons, 6-30 MeV carbon ions, and 1–5 MeV alpha particles. The particle tracks were compared under the manufacturer’s recommended etching conditions of 6.25 mol/l NaOH at 98℃ and under the widely adopted experimental conditions of 6.25 mol/l NaOH at 70℃. The results show that if the NaOH solution concentration is 6.25 mol/l, then the temperature of 70℃is more suitable for etching proton tracks than 98℃ and employing a temperature of 98 ℃ to etch alpha-particle and carbon-ion tracks can significantly reduce the etching time. Moreover, this result implies that C3+ ion or alpha-particle tracks can be distinguished from proton tracks with energy above 3 MeV by controlling the etching time. This calibration method for the CR-39 detector can be applied to the diagnosis of reaction products in laser–plasma experiments.展开更多
In this research we try to investigate the optimum etching time for the tracks originate in (CR-39) solid state nuclear track detector after irradiated with alpha source (<sup>241</sup>Am) using three diff...In this research we try to investigate the optimum etching time for the tracks originate in (CR-39) solid state nuclear track detector after irradiated with alpha source (<sup>241</sup>Am) using three different etching techniques: the traditional method (water bath), microwaves and ultrasound devices. The track etching parameters: bulk etch rate (V<sub>B</sub>), track etch rate (V<sub>T</sub>), track etch rate ratio evaluates (V), critical angle (θ<sub>C</sub>), and etching efficiency (η) were calculated in this research. It’s seen that the optimum etching time was ranging with (60 - 150 min), (20 - 30 min) and (60 - 120 min) when etching with water bath, microwave and ultrasound respectively. Also we observed that the critical angle was (24.29) when etching CR-39 detector with microwave. This value is lower than the critical angles values for the detector etched with water bath or ultrasound;thus it can be the optimum magnitude because its decrease leads to increasing the number of the tracks appeared in the detector and the etching efficiency.展开更多
In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of...In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of induced fission tracks. The results show that, the uranium concentrations ranged from 4.61 ppm, 56.93 Bq/kg (AL-Falluja AL-Jolan District) to 1.81 ppm 22.35 Bq/kg (Anah)with an average 3.42±0.79 ppm, 41.76±9.04 Bq/kg. The present results have shown that the uranium concentrations in the studied surface soil samples were less than the allowed limit 11.7 ppm recommended by UNSCEAR, 1993.展开更多
The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi m...The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples.展开更多
The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the ...The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the diameter square of alpha particle with different energies at constant bulk etch rate VB (1.45 μm/hr) by using TRACK_TEST program from Brun et al. function and Yu et al. function. Using the new equation, the maximum values of the track lengths of alpha particles measured in CR-39 detector have been found to be in a good agreement with the values measured by using Brun et al. function and Yu et al. function in TRACK_TEST program.展开更多
In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (...In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (CR-39). The results of measurements have shown that the highest average radon concentration in water samples is found in AL-Refai region which is equal to (0.223 ± 0.03 Bq/L), while the lowest average radon gas concentration is found in AL-Fajr region which is equal to (0.108 ± 0.01 Bq/L), with an average value of (0.175 ± 0.03 Bq/L). The highest value of annual effective dose (AED) in tap water samples is found in AL-Refai region, which is equal to (0.814 μSv/y), while the lowest value of (AED) is found in AL-Fajr region which is equal to (0.394 μSv/y), with an average value of (0.640 ± 0.1 μSv/y). The present results have shown that radon gas concentrations in tap water samples are less than the recommended international value (11.1 Bq/L). There for tap water in all the studied sites in Thi-Qar governorate is safe as for as radon concentration being concerned.展开更多
基金This work was supported by the National Key Research and Development Project(No.2016YFA0400502)the National Natural Science Foundation of China(No.11775312).
文摘It is of particular interest to investigate nuclear fusion reactions generated by high-intensity lasers in plasma environments that are similar to real astrophysical conditions.We have experimentally investigated2H(d,p)3H,one of the most crucial reactions in big bang nucleosynthesis models,at the Shenguang-Ⅱlaser facility.In this work,we present a new calibration of CR-39 solidstate track detectors,which are widely employed as the main diagnostics in this type of fusion reaction experiment.We measure the dependence of the track diameter on the proton energy.It is found that the track diameters of protons with different energies are likely to be identical.We propose that in this case,the energy of the reaction products can be obtained by considering both the diameters and gray levels of these tracks.The present results would be very helpful for analyzing the2 H(d,p)3H reaction products recorded with the same batch of CR-39 solid-state track detectors.
文摘In this work, a simple and accurate method for U and Th determination in natural samples is proposed. This method is based on simplified calculations of the efficiency factor of the solid state track detector using a thin source approach. Samples were firstly saluted using a concentrated H2SO4 acid and then distributed on a glassy slide where the thickness of the sample was about 7 μm. CR-39 and LR-115 track detectors were exposed to the thin layer of the natural samples for few days and then the track densities were obtained. By the mean of originated track densities in CR-39 and LR-115 as a function of exposure time and sample weight, the concentration of U and Th in Bq/kg were obtained by the thin source approach of SSNTD.
基金supported in part by the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB160203)the National Natural Science Foundation of China(Nos.11875311,11421505,and 11475245)
文摘Charged particle diagnosis is an important aspect of laser–plasma experiments conducted at super-intense laser facilities. In recent years, Columbia Resin #39 (CR- 39) detectors have been widely employed for detecting charged particles in laser–plasma experiments. This is because the CR-39 polymer does not respond to electromagnetic pulses or X-rays. This study presents a method for calibrating the relationship between particle energy and track diameter in a CR-39 detector (TasTrak■) using 3-8 MeV protons, 6-30 MeV carbon ions, and 1–5 MeV alpha particles. The particle tracks were compared under the manufacturer’s recommended etching conditions of 6.25 mol/l NaOH at 98℃ and under the widely adopted experimental conditions of 6.25 mol/l NaOH at 70℃. The results show that if the NaOH solution concentration is 6.25 mol/l, then the temperature of 70℃is more suitable for etching proton tracks than 98℃ and employing a temperature of 98 ℃ to etch alpha-particle and carbon-ion tracks can significantly reduce the etching time. Moreover, this result implies that C3+ ion or alpha-particle tracks can be distinguished from proton tracks with energy above 3 MeV by controlling the etching time. This calibration method for the CR-39 detector can be applied to the diagnosis of reaction products in laser–plasma experiments.
文摘In this research we try to investigate the optimum etching time for the tracks originate in (CR-39) solid state nuclear track detector after irradiated with alpha source (<sup>241</sup>Am) using three different etching techniques: the traditional method (water bath), microwaves and ultrasound devices. The track etching parameters: bulk etch rate (V<sub>B</sub>), track etch rate (V<sub>T</sub>), track etch rate ratio evaluates (V), critical angle (θ<sub>C</sub>), and etching efficiency (η) were calculated in this research. It’s seen that the optimum etching time was ranging with (60 - 150 min), (20 - 30 min) and (60 - 120 min) when etching with water bath, microwave and ultrasound respectively. Also we observed that the critical angle was (24.29) when etching CR-39 detector with microwave. This value is lower than the critical angles values for the detector etched with water bath or ultrasound;thus it can be the optimum magnitude because its decrease leads to increasing the number of the tracks appeared in the detector and the etching efficiency.
文摘In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of induced fission tracks. The results show that, the uranium concentrations ranged from 4.61 ppm, 56.93 Bq/kg (AL-Falluja AL-Jolan District) to 1.81 ppm 22.35 Bq/kg (Anah)with an average 3.42±0.79 ppm, 41.76±9.04 Bq/kg. The present results have shown that the uranium concentrations in the studied surface soil samples were less than the allowed limit 11.7 ppm recommended by UNSCEAR, 1993.
文摘The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples.
文摘The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the diameter square of alpha particle with different energies at constant bulk etch rate VB (1.45 μm/hr) by using TRACK_TEST program from Brun et al. function and Yu et al. function. Using the new equation, the maximum values of the track lengths of alpha particles measured in CR-39 detector have been found to be in a good agreement with the values measured by using Brun et al. function and Yu et al. function in TRACK_TEST program.
文摘In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (CR-39). The results of measurements have shown that the highest average radon concentration in water samples is found in AL-Refai region which is equal to (0.223 ± 0.03 Bq/L), while the lowest average radon gas concentration is found in AL-Fajr region which is equal to (0.108 ± 0.01 Bq/L), with an average value of (0.175 ± 0.03 Bq/L). The highest value of annual effective dose (AED) in tap water samples is found in AL-Refai region, which is equal to (0.814 μSv/y), while the lowest value of (AED) is found in AL-Fajr region which is equal to (0.394 μSv/y), with an average value of (0.640 ± 0.1 μSv/y). The present results have shown that radon gas concentrations in tap water samples are less than the recommended international value (11.1 Bq/L). There for tap water in all the studied sites in Thi-Qar governorate is safe as for as radon concentration being concerned.