Calibration of CR-39 solid-state track detectors for study of laser-driven nuclear reactions 被引量:2
1
作者 Yang-Fan He Xiao-Feng Xi +12 位作者 Shi-Lun Guo Bing Guo Chuang-Ye He Fu-Long Liu Di Wu Ji-Hong Wei Wan-Sha Yang Luo-Huan Wang Dong-Hai Zhang Meng-Lin Qiu Guang-Fu Wang Chao-Yang Li Xiao-Fei Lan 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第4期118-122,共5页
It is of particular interest to investigate nuclear fusion reactions generated by high-intensity lasers in plasma environments that are similar to real astrophysical conditions.We have experimentally investigated2H(d,... It is of particular interest to investigate nuclear fusion reactions generated by high-intensity lasers in plasma environments that are similar to real astrophysical conditions.We have experimentally investigated2H(d,p)3H,one of the most crucial reactions in big bang nucleosynthesis models,at the Shenguang-Ⅱlaser facility.In this work,we present a new calibration of CR-39 solidstate track detectors,which are widely employed as the main diagnostics in this type of fusion reaction experiment.We measure the dependence of the track diameter on the proton energy.It is found that the track diameters of protons with different energies are likely to be identical.We propose that in this case,the energy of the reaction products can be obtained by considering both the diameters and gray levels of these tracks.The present results would be very helpful for analyzing the2 H(d,p)3H reaction products recorded with the same batch of CR-39 solid-state track detectors. 展开更多
关键词 BIG bang NUCLEOSYNTHESIS LASER-DRIVEN nuclear reactions cr-39 detectors GRAY levels
下载PDF
U and Th Determination in Natural Samples Using CR-39 and LR-115 Track Detectors
2
作者 S. A. Eman S. H. Nageeb A. R. El-Sersy 《World Journal of Nuclear Science and Technology》 2012年第1期36-40,共5页
In this work, a simple and accurate method for U and Th determination in natural samples is proposed. This method is based on simplified calculations of the efficiency factor of the solid state track detector using a ... In this work, a simple and accurate method for U and Th determination in natural samples is proposed. This method is based on simplified calculations of the efficiency factor of the solid state track detector using a thin source approach. Samples were firstly saluted using a concentrated H2SO4 acid and then distributed on a glassy slide where the thickness of the sample was about 7 μm. CR-39 and LR-115 track detectors were exposed to the thin layer of the natural samples for few days and then the track densities were obtained. By the mean of originated track densities in CR-39 and LR-115 as a function of exposure time and sample weight, the concentration of U and Th in Bq/kg were obtained by the thin source approach of SSNTD. 展开更多
关键词 U TH cr-39 and LR-115
下载PDF
CO_(2)预处理对CR-39中子个人剂量计增敏特性的研究
3
作者 赵阳 王勰 +5 位作者 夏斌元 李硕 王亮 彭微颖 刘柯钊 熊忠华 《核技术》 EI CAS CSCD 北大核心 2024年第10期115-125,共11页
本文研究了CO_(2)预处理对CR-39探测器灵敏度及径迹特征形成影响。以经^(252)Cf中子源照射的CR-39探测器为研究对象,通过统计探测器记录径迹数与径迹尺寸,分析了不同CO_(2)预处理时间和压力对CR-39探测器灵敏度及径迹尺寸分布的影响规... 本文研究了CO_(2)预处理对CR-39探测器灵敏度及径迹特征形成影响。以经^(252)Cf中子源照射的CR-39探测器为研究对象,通过统计探测器记录径迹数与径迹尺寸,分析了不同CO_(2)预处理时间和压力对CR-39探测器灵敏度及径迹尺寸分布的影响规律。研究结果表明:经CO_(2)预处理后CR-39探测器灵敏度及最大径迹尺寸得到显著提高,灵敏度最大提升870%,最大径迹尺寸由20μm增大至40μm;探测器灵敏度与预处理压力时间存在特定正相关关系,灵敏度随CO_(2)压力线性增大;最大径迹尺寸在40μm附近增长达到饱和,继续提高预处理时间和压力,径迹包含的中子能谱特征不再被保留;本实验获得的CO_(2)预处理下CR-39形成径迹保留能谱特征的最佳灵敏度为6.25 tracks·mm^(-2)·mSv^(-1)。这项研究对于提高CR-39中子个人剂量计灵敏度及选择合适CO_(2)预处理条件方面具有重要意义,同时也提供了一种在提升径迹可读性时保留径迹能谱特征信息的预处理方法,可应用于基于中子能谱特征优化中子个人剂量当量评估。 展开更多
关键词 cr-39探测器 CO_(2)预处理 增敏作用 中子剂量 径迹尺寸分布
下载PDF
Optical Properties of CR-39 Track Etch Detectors Irradiated by Alpha Particles with Different Energies
4
作者 Mostafa Fawzy Eissa 《材料科学与工程(中英文版)》 2011年第1期26-31,共6页
关键词 径迹探测器 光学特性 径迹蚀刻 粒子辐照 能量通量 CR 阿尔法 光学性质
下载PDF
The Effect of (x-Radiation Dose on CR-39 Polymer Track Detectors Using Positron Annihilation Lifetime and UV-Spectroscopy
5
作者 Mostafa Fawzy Eissa Esmat Mohamed Hassan Emad A. Badawi 《材料科学与工程(中英文版)》 2010年第11期48-52,共5页
关键词 正电子湮没寿命谱 光谱探测器 剂量效应 CR X射线 紫外线 聚合物 跟踪
下载PDF
Energy calibration of a CR-39 nuclear-track detector irradiated by charged particles 被引量:1
6
作者 Yue Zhang Hong-Wei Wang +5 位作者 Yu-Gang Ma Long-Xiang Liu Xi-Guang Cao Gong-Tao Fan Guo-Qiang Zhang De-Qing Fang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第6期1-9,共9页
Charged particle diagnosis is an important aspect of laser–plasma experiments conducted at super-intense laser facilities. In recent years, Columbia Resin #39 (CR- 39) detectors have been widely employed for detectin... Charged particle diagnosis is an important aspect of laser–plasma experiments conducted at super-intense laser facilities. In recent years, Columbia Resin #39 (CR- 39) detectors have been widely employed for detecting charged particles in laser–plasma experiments. This is because the CR-39 polymer does not respond to electromagnetic pulses or X-rays. This study presents a method for calibrating the relationship between particle energy and track diameter in a CR-39 detector (TasTrak■) using 3-8 MeV protons, 6-30 MeV carbon ions, and 1–5 MeV alpha particles. The particle tracks were compared under the manufacturer’s recommended etching conditions of 6.25 mol/l NaOH at 98℃ and under the widely adopted experimental conditions of 6.25 mol/l NaOH at 70℃. The results show that if the NaOH solution concentration is 6.25 mol/l, then the temperature of 70℃is more suitable for etching proton tracks than 98℃ and employing a temperature of 98 ℃ to etch alpha-particle and carbon-ion tracks can significantly reduce the etching time. Moreover, this result implies that C3+ ion or alpha-particle tracks can be distinguished from proton tracks with energy above 3 MeV by controlling the etching time. This calibration method for the CR-39 detector can be applied to the diagnosis of reaction products in laser–plasma experiments. 展开更多
关键词 cr-39 detector Energy calibration BULK ETCH rate ETCHING temperature
下载PDF
Studying Different Etching Methods Using CR-39 Nuclear Track Detector 被引量:1
7
作者 Nada Farhan Kadhum Layth Abdulhakeem Jebur Ali A. Ridha 《Detection》 2016年第3期45-53,共9页
In this research we try to investigate the optimum etching time for the tracks originate in (CR-39) solid state nuclear track detector after irradiated with alpha source (<sup>241</sup>Am) using three diff... In this research we try to investigate the optimum etching time for the tracks originate in (CR-39) solid state nuclear track detector after irradiated with alpha source (<sup>241</sup>Am) using three different etching techniques: the traditional method (water bath), microwaves and ultrasound devices. The track etching parameters: bulk etch rate (V<sub>B</sub>), track etch rate (V<sub>T</sub>), track etch rate ratio evaluates (V), critical angle (θ<sub>C</sub>), and etching efficiency (η) were calculated in this research. It’s seen that the optimum etching time was ranging with (60 - 150 min), (20 - 30 min) and (60 - 120 min) when etching with water bath, microwave and ultrasound respectively. Also we observed that the critical angle was (24.29) when etching CR-39 detector with microwave. This value is lower than the critical angles values for the detector etched with water bath or ultrasound;thus it can be the optimum magnitude because its decrease leads to increasing the number of the tracks appeared in the detector and the etching efficiency. 展开更多
关键词 Chemical Etching MICROWAVE ULTRASOUND cr-39 Track Etching Parameters
下载PDF
Uranium Concentrations in Surface Soil Samples for Selected Regionsin AI-Anbar Governorate (Iraq) Using CR-39 Track Detector
8
作者 Nada Fadhil Tawfiq Hazim Louis Mansour Mahmood Salim Karim 《Journal of Physical Science and Application》 2016年第1期67-70,共4页
In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of... In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of induced fission tracks. The results show that, the uranium concentrations ranged from 4.61 ppm, 56.93 Bq/kg (AL-Falluja AL-Jolan District) to 1.81 ppm 22.35 Bq/kg (Anah)with an average 3.42±0.79 ppm, 41.76±9.04 Bq/kg. The present results have shown that the uranium concentrations in the studied surface soil samples were less than the allowed limit 11.7 ppm recommended by UNSCEAR, 1993. 展开更多
关键词 Uranium concentration cr-39 track detector fission tracks surface soil.
下载PDF
Determination of Alpha Particles Concentration in Toothpaste Using CR-39 Track Detector
9
作者 Fouad A. Majeed Inaam H. Kadhim +1 位作者 Ali O. Muhsen Khalid H. Abass 《Detection》 2015年第2期9-13,共5页
The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi m... The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples. 展开更多
关键词 ALPHA CONCENTRATION cr-39 detector FISSION TRACK Technique TOOTHPASTE
下载PDF
A New Method to Determine the Maximum Value of the Track Length of Alpha Particle in CR-39 Detector
10
作者 Hussein A. Ahmed A. Mohammed A. Said Ahmad 《Materials Sciences and Applications》 2015年第2期145-151,共7页
The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the ... The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the diameter square of alpha particle with different energies at constant bulk etch rate VB (1.45 μm/hr) by using TRACK_TEST program from Brun et al. function and Yu et al. function. Using the new equation, the maximum values of the track lengths of alpha particles measured in CR-39 detector have been found to be in a good agreement with the values measured by using Brun et al. function and Yu et al. function in TRACK_TEST program. 展开更多
关键词 Maximum Value of TRACK LENGTH cr-39 Range of ALPHA Particle Nuclear TRACK detector (NTD)
下载PDF
Measurement of Radon Gas Concentrations in Tap Water Samples for Thi-Qar Governorate Using Nuclear Track Detector (CR-39)
11
作者 Liath Ahmed Najam Hazim Louis Mansour +1 位作者 Nada Fadhil Tawfiq Mahmood Salim Karim 《Detection》 2016年第1期1-8,共8页
In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (... In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (CR-39). The results of measurements have shown that the highest average radon concentration in water samples is found in AL-Refai region which is equal to (0.223 ± 0.03 Bq/L), while the lowest average radon gas concentration is found in AL-Fajr region which is equal to (0.108 ± 0.01 Bq/L), with an average value of (0.175 ± 0.03 Bq/L). The highest value of annual effective dose (AED) in tap water samples is found in AL-Refai region, which is equal to (0.814 μSv/y), while the lowest value of (AED) is found in AL-Fajr region which is equal to (0.394 μSv/y), with an average value of (0.640 ± 0.1 μSv/y). The present results have shown that radon gas concentrations in tap water samples are less than the recommended international value (11.1 Bq/L). There for tap water in all the studied sites in Thi-Qar governorate is safe as for as radon concentration being concerned. 展开更多
关键词 RADON Solid State Nuclear Track detectors cr-39 Radon in Water
下载PDF
CR-39探测器对α粒子入射角度和能量响应的实验研究 被引量:9
12
作者 卓维海 陈波 +1 位作者 李德红 季华钧 《原子能科学技术》 EI CAS CSCD 北大核心 2008年第B09期322-325,共4页
为掌握固体径迹探测器CR-39对α粒子的入射角度和能量响应特性,通过建立1个可调节α粒子的入射角度和入射能量的241Am源照射系统,进行了不同入射角度和入射能量的α粒子照射CR-39探测器的实验研究,比较了不同照射条件下的径迹密度。实... 为掌握固体径迹探测器CR-39对α粒子的入射角度和能量响应特性,通过建立1个可调节α粒子的入射角度和入射能量的241Am源照射系统,进行了不同入射角度和入射能量的α粒子照射CR-39探测器的实验研究,比较了不同照射条件下的径迹密度。实验结果表明,CR-39对α粒子的能量响应下限约为0.5 MeV,对入射角度响应的上限约为70°。本研究结果可为优化设计测氡的扩散杯(瓶)、提高其对氡的探测效率等提供科学的指导依据。 展开更多
关键词 cr-39探测器 Α粒子 角度响应 能量响应
下载PDF
CR-39固体核径迹探测器蚀刻技术新进展 被引量:8
13
作者 王丽琴 屈喜梅 +4 位作者 焦玲 丁艳秋 武权 张仲健 张文艺 《核技术》 CAS CSCD 北大核心 2012年第11期863-868,共6页
固体核径迹探测器在辐射研究和放射防护剂量学方面有着非常广泛的应用前景,CR-39探测器作为其中必不可少的一员,近年来也广受科研工作者的偏爱。本文简要介绍和对比了几种常用的中子固体核径迹探测器,并着重介绍了CR-39探测器及其蚀刻方... 固体核径迹探测器在辐射研究和放射防护剂量学方面有着非常广泛的应用前景,CR-39探测器作为其中必不可少的一员,近年来也广受科研工作者的偏爱。本文简要介绍和对比了几种常用的中子固体核径迹探测器,并着重介绍了CR-39探测器及其蚀刻方法,同时总结了影响CR-39中子探测器蚀刻速率的基本因素,阐述了CR-39探测器蚀刻技术的重要性并展望了其在其它领域的应用。 展开更多
关键词 cr-39探测器 蚀刻 影响因素
下载PDF
CR-39固体核径迹探测器用于中子测量化学蚀刻参数的优化 被引量:8
14
作者 王兴功 骆亿生 +2 位作者 张红 周郁 郭勇 《核技术》 EI CAS CSCD 北大核心 2005年第4期319-323,共5页
通过实验确定了CR-39固体核径迹探测器用于中子测量的化学蚀刻条件。根据有关资料和经验,对蚀刻结果影响较大的三个因子——蚀刻溶液的浓度(mol/L)、温度(℃)和蚀刻时间(h),采用正交试验法,并对正交试验进行补充和验证;通过对实验结果... 通过实验确定了CR-39固体核径迹探测器用于中子测量的化学蚀刻条件。根据有关资料和经验,对蚀刻结果影响较大的三个因子——蚀刻溶液的浓度(mol/L)、温度(℃)和蚀刻时间(h),采用正交试验法,并对正交试验进行补充和验证;通过对实验结果综合分析比较,在NaOH溶液浓度为5.5mol/L、温度70℃和时间24h的蚀刻条件下,CR-39固体核径迹探测器对中子所形成的径迹轮廓清晰、大小适度,蚀刻效率高,易于识别和测读,能满足中子测量的需要。 展开更多
关键词 cr-39固体核径迹探测器 正交试验 化学蚀刻 径迹
下载PDF
CR-39固体核径迹探测器观测方法 被引量:4
15
作者 黄三玻 魏志勇 +6 位作者 方美华 杨永常 张紫霞 雷升杰 陈国云 黎光武 郭刚 《核电子学与探测技术》 CAS CSCD 北大核心 2011年第9期1008-1013,共6页
针对重离子辐射的CR-39固体核径迹探测器中的微观径迹结构特点和剂量特征研究的必要步骤———探测器观测,从CR-39中粒子潜径迹形成和发展出发,探讨了影响粒子径迹的因素,选取两种径迹观测方法———光学显微镜观测和电子显微镜观测进... 针对重离子辐射的CR-39固体核径迹探测器中的微观径迹结构特点和剂量特征研究的必要步骤———探测器观测,从CR-39中粒子潜径迹形成和发展出发,探讨了影响粒子径迹的因素,选取两种径迹观测方法———光学显微镜观测和电子显微镜观测进行对比分析。在此基础上进行了试验,用不同通量的100 MeV Si离子照射CR-39探测器,将实验样品用NaOH溶液(70℃6,.25 N)分别进行6h和5 min的刻蚀。刻蚀后,用光学显微镜和原子力显微镜进行观察,得到了放大的径迹和纳米尺度的微观径迹。此外,局部覆盖刻蚀后用台阶仪进行观测,得到了体刻蚀速率为Vb=1.53μm/h。 展开更多
关键词 cr-39固体核径迹探测器 刻蚀速率 光学显微镜 原子力显微镜
下载PDF
CR-39对各向同性中子的能量响应研究 被引量:1
16
作者 李义国 赵修良 +5 位作者 朱庆福 曹健 夏普 史永谦 罗璋琳 骆亿生 《核技术》 EI CAS CSCD 北大核心 2005年第9期704-706,共3页
建立了由聚乙烯、铅和CR-39组成的叠层探测器探测各向同性中子能谱模型,计算了叠层探测器对各向同性中子的能量响应以及叠层探测器的能量分辨率。计算结果表明,叠层探测器的响应和能量分辨率与中子能量、聚乙烯以及铅衰减层厚度有关。... 建立了由聚乙烯、铅和CR-39组成的叠层探测器探测各向同性中子能谱模型,计算了叠层探测器对各向同性中子的能量响应以及叠层探测器的能量分辨率。计算结果表明,叠层探测器的响应和能量分辨率与中子能量、聚乙烯以及铅衰减层厚度有关。聚乙烯厚度不变,响应峰值和能量分辨率随铅的厚度增加而变小;铅的厚度不变,响应峰值和能量分辨率随聚乙烯厚度增加而变大,且响应函数形状改变。 展开更多
关键词 各向同性中子 能量响应 cr-39 叠层探测器
下载PDF
纳米尺度上CR-39径迹蚀刻动力学研究 被引量:1
17
作者 方美华 魏志勇 +6 位作者 黄三玻 杨永常 张紫霞 陈国云 雷升杰 黎光武 郭刚 《核科学与工程》 CSCD 北大核心 2011年第3期263-269,共7页
在对CR-39探测器蚀刻6 h后发现照射区域与未照射区域的体蚀刻速率明显不同,因此用传统的几何模型无法正确得到几何量和物理量之间的对应联系。本文在以往辐射粒子固体径迹研究基础上,利用新的AFM观测手段得到纳米尺度的CR-39三维蚀刻径... 在对CR-39探测器蚀刻6 h后发现照射区域与未照射区域的体蚀刻速率明显不同,因此用传统的几何模型无法正确得到几何量和物理量之间的对应联系。本文在以往辐射粒子固体径迹研究基础上,利用新的AFM观测手段得到纳米尺度的CR-39三维蚀刻径迹坑,并对探测器蚀刻几何模型进行了修正,提出了新的蚀刻速率比:V′=Vt/Virr对几何模型中各个参数进行计算。用修正的几何模型对100 MeV的Si离子的AFM观测结果进行分析。研究表明,100 MeV Si离子的径迹蚀刻速率:Vt=4.12μm/h,Virr=2.55μm/h,V′=1.62,Si离子入射角度为61.03°。同时我们通过局部覆盖法和台阶仪,得到本实验用CR-39的体蚀刻速率Vb=1.58μm/h。两者结合得到100 MeV Si离子的蚀刻速率比:V=2.61>V′。本研究采用传统的几何模型方法经过合理修正应用于新的观测手段,并得到了纳米尺度上蚀刻动力学关键参量。 展开更多
关键词 固体径迹 AFM cr-39 纳米尺度 蚀刻速率比
下载PDF
湿度对CR-39固体核径迹探测器测量^(220)Rn/^(222)Rn水平的影响研究 被引量:6
18
作者 肖拥军 周青芝 汤凌志 《南华大学学报(自然科学版)》 2010年第2期12-14,共3页
在可调控温度、湿度及氡浓度的南华大学氡实验室对不同的湿度条件下CR-39固体核径迹探测器测量220Rn2、22Rn的探测效率进行了测定,分析了湿度对CR-39固体核径迹探测器测量220Rn、222Rn探测效率的影响.实验结果表明:相对湿度在35%-95%范... 在可调控温度、湿度及氡浓度的南华大学氡实验室对不同的湿度条件下CR-39固体核径迹探测器测量220Rn2、22Rn的探测效率进行了测定,分析了湿度对CR-39固体核径迹探测器测量220Rn、222Rn探测效率的影响.实验结果表明:相对湿度在35%-95%范围内,当湿度为50%左右时,CR-39固体核径迹探测器测222Rn,探测效率最高,标准偏差为2.0%;相对湿度在30%-100%范围内,当湿度为75%时,CR-39固体核径迹探测器测220Rn的探测效率最低,标准偏差达到78.4%. 展开更多
关键词 220Rn/222Rn累积测量 固体径迹探测器 cr-39 湿度效应 探测效率
下载PDF
CR-39中子个人剂量计在石油企业中应用的概况与进展 被引量:1
19
作者 李俊雯 《中国预防医学杂志》 CAS 2002年第3期228-229,共2页
中子剂量的计算与测量,特别是中子个人剂量的监测,是一项技术相当复杂的工作.然而,对中子,特别是快中子,由于具有较高的品质因数,往往成为在某些中子-γ混合辐射场中工作人员所受剂量当量的重要贡献.所以,在这些场所快中子剂量的监测是... 中子剂量的计算与测量,特别是中子个人剂量的监测,是一项技术相当复杂的工作.然而,对中子,特别是快中子,由于具有较高的品质因数,往往成为在某些中子-γ混合辐射场中工作人员所受剂量当量的重要贡献.所以,在这些场所快中子剂量的监测是必须的. 展开更多
关键词 cr-39 中子个人剂量计 石油企业 辐射防护学
下载PDF
CR-39中子探测器刻度系数的测定
20
作者 李涤 张谦 李鑫 《中国辐射卫生》 2003年第4期245-245,共1页
目的 为了工作人员的身体健康,对油田的工作人员进行中子个人剂量计的监测。方法 用CR-39中子探测器测量中子剂量。结果 刻度系数为K=11.5×10^(-3) mSv/tr·cm^2。结论 用CR-39测量中子剂量切实可行。
关键词 cr-39中子探测器 刻度系数 个人剂量 放射卫生