Improved design and construction of an ionization chamber for the CSNS beam loss monitor (BLM)
1
作者 田建民 徐美杭 +5 位作者 赵中亮 陈昌 阮向东 陈元柏 徐韬光 陆双桐 《Chinese Physics C》 SCIE CAS CSCD 2012年第4期329-333,共5页
Based on the first ionization chamber (IC) prototype, the structure, working gas component and electrode material of the IC are improved. The test of the improved IC shows that the plateau length is about 2000 V, th... Based on the first ionization chamber (IC) prototype, the structure, working gas component and electrode material of the IC are improved. The test of the improved IC shows that the plateau length is about 2000 V, the plateau slope is less than 0.2%/100 V, the sensitivity is 19.6 pA/rad·h 1, the up-limitation of the linearity can be up to 3.6×105 rad/h, and the applied voltage can be operated to 3500 V. The test results show that the performance of the improved IC meets the requirements of the beam loss monitor. 展开更多
关键词 csns blm detector ionization chamber plateau curve