胸部X射线CT扫描中的放射防护最优化 被引量:1
1
作者 李士骏 朱晓华 《辐射防护》 CAS CSCD 北大核心 2006年第3期129-136,共8页
X射线螺旋CT机不同扫描条件下,用有机玻璃均匀模体测量多层扫描的CT剂量指数值,用均匀水模体测量CT值的均匀性及其噪声。比较了不同扫描条件下,患者肺部肿块影及片状影的CT图像质量。结果表明:曝露量为402、5、7.5 mAs时的CT剂量指数值... X射线螺旋CT机不同扫描条件下,用有机玻璃均匀模体测量多层扫描的CT剂量指数值,用均匀水模体测量CT值的均匀性及其噪声。比较了不同扫描条件下,患者肺部肿块影及片状影的CT图像质量。结果表明:曝露量为402、5、7.5 mAs时的CT剂量指数值分别不超过曝露量为115 mAs时的40%、30%和15%。本文用CT扫描“优化因子”作为图像质量、病人所受剂量的综合评价指标,实现了CT扫描条件优化的定量分析。虽然,随X射线曝露量减少,均匀模体断层内CT值噪声增加、正常图像百分率下降,但从图像质量、病人剂量综合考虑,X射线胸部CT扫描的曝露量宜取25 mAs。 展开更多
关键词 X射线ct 胸部扫描 曝露量 ct剂量指数 ct均匀性 ct值噪声 ct扫描优化因子
下载PDF
Clinical Value of Dual-energy CT in Detection of Pancreatic Adenocarcinoma: Investigation of the Best Pancreatic Tumor Contrast to Noise Ratio 被引量:2
2
作者 Yong-lan He Da-ming Zhang +1 位作者 Hua-dan Xue Zheng-yu Jin 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期207-212,共6页
Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 m... Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 male, 7 female, average age 59.4±13.2 years) with pathologically diagnosed pancreatic cancer were enrolled. All patients received an abdominal scan using a dual source CT scanner 7 to 31 days before biopsy or surgery. After injection of iodine contrast agent, arterial and pancreatic parenchyma phase were scanned consequently, using a dual-energy scan mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs) in the pancreatic parenchyma phase. A series of derived dual-energy datasets were evaluated including non-liner blending (non-linear blending width 0-500 HU; blending center -500 to 500 HU), mono-energetic (40-190 keV), 100 kVp and 140 kVp. On each datasets, mean CT values of the pancreatic parenchyma and tumor, as well as standard deviation CT values of subcutaneous fat and psoas muscle were measured. Regions of interest of cutaneous fat and major psoas muscle of 100 kVp and 140 kVp images were calculated. Best CNR of subcutaneous fat (CNR F ) and CNR of the major psoas muscle (CNR M ) of non-liner blending and mono-energetic datasets were calculated with the optimal mono-energetic keV setting and the optimal blending center/width setting for the best CNR. One Way ANOVA test was used for comparison of best CNR between different dual-energy derived datasets. Results The best CNR F (4.48±1.29) was obtained from the non-liner blending datasets at blending center -16.6±103.9 HU and blending width 12.3±10.6 HU. The best CNR F (3.28±0.97) was obtained from the mono-energetic datasets at 73.3±4.3 keV. CNR F in the 100 kVp and 140 kVp were 3.02±0.91 and 1.56±0.56 respectively. Using fat as the noise background, all of these images series showed significant differences (P<0.01) except best CNR F of mono-energetic image sets vs. CNR F of 100 kVp image (P=0.460). Similar results were found using muscle as the noise background (mono-energetic image vs. 100 kVp image: P=0.246; mono-energetic image vs. non-liner blending image: P=0.044; others: P<0.01). Conclusion Compared with mono-energetic datasets and low kVp datasets, non-linear blending image at automatically chosen blending width/window provides better tumor to the pancreas CNR, which might be beneficial for better detection of pancreatic tumors. 展开更多
关键词 pancreatic adenocarcinoma DUAL-ENERGY contrast to noise ratio non-linear blending