Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, res...Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, resuscitation should achieve a central venous pressure (CVP) of 8-12 mmHg within the first 6 h. However, it is still uncertain about the sensitivity and specificity of CVP in reflecting the cardiac preload. Ultrasonography is a simple, rapid, non-invasive, and repeatable method for the measurement of sensitivity and specificity of CVP and has thus gradually attracted the increasing attention of physicians. It was reported that ultrasonography can show the inferior vena cava diameter, respiratory variability index, and blood volume in patients with sepsis or heart failure.展开更多
目的系统评价不同卧位对患者中心静脉压测量的影响。方法计算机检索Cochrane Library、MEDLINE、EMbase、中国生物医学文献服务系统、中国学术期刊全文数据库以及万方数据库中公开发表的相关文献,由3名研究者对文献进行评鉴,对纳入研究...目的系统评价不同卧位对患者中心静脉压测量的影响。方法计算机检索Cochrane Library、MEDLINE、EMbase、中国生物医学文献服务系统、中国学术期刊全文数据库以及万方数据库中公开发表的相关文献,由3名研究者对文献进行评鉴,对纳入研究使用Rev Man 5.3软件进行Meta分析。结果共纳入7篇文献,涉及406例患者。Meta分析显示:30°半卧位时测量中心静脉压值与平卧位时测量中心静脉压值间具有差异(WMD=-0.79,95%CI:-1.39^-0.18,P<0.01);45°半卧位时测量中心静脉压值与平卧位时测量中心静脉压值间具有差异(WMD=-0.96,95%CI:-1.30^-0.61,P<0.001)。结论患者可维持原30°半卧位进行中心静脉压值监测;在维持45°半卧位情况下可结合病情及中心静脉压值,指导下一步治疗及护理策略。展开更多
基于传感器技术、单片机技术、无线通信技术和LabVIEW虚拟仪器开发出的无线中心静脉压监护系统,采用NPC-1210作为压力传感器,STC89C52单片机作为接收器控制模块,通过通用串行总线(universal serial bus,USB)串口将压力数据传输至LabVIE...基于传感器技术、单片机技术、无线通信技术和LabVIEW虚拟仪器开发出的无线中心静脉压监护系统,采用NPC-1210作为压力传感器,STC89C52单片机作为接收器控制模块,通过通用串行总线(universal serial bus,USB)串口将压力数据传输至LabVIEW开发软件,实现对中心静脉压数据的采集和存储,并利用互联网技术将相关信息及时传送到医护人员手中.该系统使用了模块化的设计思路,通用性强、易于维护、操作简单、体积小,应用前景广阔,是一种用于替代医护人员执行繁琐的中心静脉压测量工作的可行系统.展开更多
文摘Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, resuscitation should achieve a central venous pressure (CVP) of 8-12 mmHg within the first 6 h. However, it is still uncertain about the sensitivity and specificity of CVP in reflecting the cardiac preload. Ultrasonography is a simple, rapid, non-invasive, and repeatable method for the measurement of sensitivity and specificity of CVP and has thus gradually attracted the increasing attention of physicians. It was reported that ultrasonography can show the inferior vena cava diameter, respiratory variability index, and blood volume in patients with sepsis or heart failure.
文摘目的系统评价不同卧位对患者中心静脉压测量的影响。方法计算机检索Cochrane Library、MEDLINE、EMbase、中国生物医学文献服务系统、中国学术期刊全文数据库以及万方数据库中公开发表的相关文献,由3名研究者对文献进行评鉴,对纳入研究使用Rev Man 5.3软件进行Meta分析。结果共纳入7篇文献,涉及406例患者。Meta分析显示:30°半卧位时测量中心静脉压值与平卧位时测量中心静脉压值间具有差异(WMD=-0.79,95%CI:-1.39^-0.18,P<0.01);45°半卧位时测量中心静脉压值与平卧位时测量中心静脉压值间具有差异(WMD=-0.96,95%CI:-1.30^-0.61,P<0.001)。结论患者可维持原30°半卧位进行中心静脉压值监测;在维持45°半卧位情况下可结合病情及中心静脉压值,指导下一步治疗及护理策略。
文摘基于传感器技术、单片机技术、无线通信技术和LabVIEW虚拟仪器开发出的无线中心静脉压监护系统,采用NPC-1210作为压力传感器,STC89C52单片机作为接收器控制模块,通过通用串行总线(universal serial bus,USB)串口将压力数据传输至LabVIEW开发软件,实现对中心静脉压数据的采集和存储,并利用互联网技术将相关信息及时传送到医护人员手中.该系统使用了模块化的设计思路,通用性强、易于维护、操作简单、体积小,应用前景广阔,是一种用于替代医护人员执行繁琐的中心静脉压测量工作的可行系统.