Biochemistry weapon is raising new tools of war and terror.This research is an experiment about portable system for CWAs (chemical warfare agents) detection using micro array gas system.CWAs were divided into four typ...Biochemistry weapon is raising new tools of war and terror.This research is an experiment about portable system for CWAs (chemical warfare agents) detection using micro array gas system.CWAs were divided into four types such as blood, nerve,vesicant,and choking agent.To detect various CWAs,semiconductor thick film sensor array based on tin oxide was fabricated and their gas responses were examined.Operating temperature was range of 250℃to 350℃and gas concentration was range of 0.1μg/g to 10μg/g.Sensor array was measured as operating temperatures,concentrations for four simulant agents of CWAs.Extracted parameters from results were carried out classification among CWAs through the principal component analysis (PCA).Also,classification of gases is studied using adaptive resonance theory (ART) that is one of neural network algorithm.Results displayed using PDA system.展开更多
In this review, we summaries the past few year work on the chemistry of CWA’s and their simulants on various heterogeneous surfaces of zeolites, composites of zeolites and doped zeolite with transition metal oxides. ...In this review, we summaries the past few year work on the chemistry of CWA’s and their simulants on various heterogeneous surfaces of zeolites, composites of zeolites and doped zeolite with transition metal oxides. This review elaborates an updated literature overview on the degradation of CWA’s and its simulants. The data written in this review were collected from the peer-reviewed national and international literature.展开更多
We present in this paper a numerical study of the validity limit of the geometrical optics approximation compared with a differential method which is established according to rigorous formalisms based on the electroma...We present in this paper a numerical study of the validity limit of the geometrical optics approximation compared with a differential method which is established according to rigorous formalisms based on the electromagnetic theory. The precedent studies show that this method is adapted to the study of diffraction by periodic rough surfaces. We determine by two methods the emissivity of gold and tungsten for surfaces with a rectangular or sinusoidal profile, for a wavelength equal to 0.55 microns. The monochromatic directional emissivity of these surfaces clearly depends on the angle of incidence, the surface profile, height, period and the nature of the material. We perform our calculations by a method of coupled wave analysis (CWA) and a geometric optics method (GOA). The latter method is theoretically valid only when the dimensions of the cavities are very large compared to the wavelength, while the CWA is theoretically correct whatever these dimensions. The main purpose of this work is to investigate the validity limit of GOA compared with CWA. The obtained results for a fixed height of the grating, allowed us to delimit the validity domain of the optic geometrical approximation for the treated cases. Finally, the agreement between the emissivity calculated by the differential method and that given on the basis of the homogenization theory is satisfactory when the period is much smaller than the wavelength.展开更多
To enhance the expressive power and the declarative ability of a deductive database, various CWA (Closed World Assumption) formalizations including the naive CWA, the generalized CWA and the careful CWA are extended ...To enhance the expressive power and the declarative ability of a deductive database, various CWA (Closed World Assumption) formalizations including the naive CWA, the generalized CWA and the careful CWA are extended to multi-valued logics. The basic idea is to embed logic formulas into some polynomial ring. The extensions can be applied in a uniform manner to any finitely multi-valued logics. Therefore they are also of computational significance.展开更多
文摘Biochemistry weapon is raising new tools of war and terror.This research is an experiment about portable system for CWAs (chemical warfare agents) detection using micro array gas system.CWAs were divided into four types such as blood, nerve,vesicant,and choking agent.To detect various CWAs,semiconductor thick film sensor array based on tin oxide was fabricated and their gas responses were examined.Operating temperature was range of 250℃to 350℃and gas concentration was range of 0.1μg/g to 10μg/g.Sensor array was measured as operating temperatures,concentrations for four simulant agents of CWAs.Extracted parameters from results were carried out classification among CWAs through the principal component analysis (PCA).Also,classification of gases is studied using adaptive resonance theory (ART) that is one of neural network algorithm.Results displayed using PDA system.
文摘In this review, we summaries the past few year work on the chemistry of CWA’s and their simulants on various heterogeneous surfaces of zeolites, composites of zeolites and doped zeolite with transition metal oxides. This review elaborates an updated literature overview on the degradation of CWA’s and its simulants. The data written in this review were collected from the peer-reviewed national and international literature.
文摘We present in this paper a numerical study of the validity limit of the geometrical optics approximation compared with a differential method which is established according to rigorous formalisms based on the electromagnetic theory. The precedent studies show that this method is adapted to the study of diffraction by periodic rough surfaces. We determine by two methods the emissivity of gold and tungsten for surfaces with a rectangular or sinusoidal profile, for a wavelength equal to 0.55 microns. The monochromatic directional emissivity of these surfaces clearly depends on the angle of incidence, the surface profile, height, period and the nature of the material. We perform our calculations by a method of coupled wave analysis (CWA) and a geometric optics method (GOA). The latter method is theoretically valid only when the dimensions of the cavities are very large compared to the wavelength, while the CWA is theoretically correct whatever these dimensions. The main purpose of this work is to investigate the validity limit of GOA compared with CWA. The obtained results for a fixed height of the grating, allowed us to delimit the validity domain of the optic geometrical approximation for the treated cases. Finally, the agreement between the emissivity calculated by the differential method and that given on the basis of the homogenization theory is satisfactory when the period is much smaller than the wavelength.
文摘To enhance the expressive power and the declarative ability of a deductive database, various CWA (Closed World Assumption) formalizations including the naive CWA, the generalized CWA and the careful CWA are extended to multi-valued logics. The basic idea is to embed logic formulas into some polynomial ring. The extensions can be applied in a uniform manner to any finitely multi-valued logics. Therefore they are also of computational significance.