期刊文献+
共找到24篇文章
< 1 2 >
每页显示 20 50 100
Comparative Study on Structural Redundancy of Cable-Stayed and Extradosed Bridges Through Safety Assessment of Their Stay Cables 被引量:5
1
作者 Khawaja Ali Hiroshi Katsuchi Hitoshi Yamada 《Engineering》 SCIE EI 2021年第1期111-123,共13页
This study provides new insights into the comparison of cable-stayed and extradosed bridges based on the safety assessment of their stay cables.These bridges are often regarded as identical structures owing to the use... This study provides new insights into the comparison of cable-stayed and extradosed bridges based on the safety assessment of their stay cables.These bridges are often regarded as identical structures owing to the use of inclined cables;however,the international standards for bridge design stipulate different safety factors for stay cables of both types of bridges.To address this misconception,a comparative study was carried out on the safety factors of stay cables under fatigue and ultimate limit states by considering the effects of various untoward and damaging factors,such as overloading,cable loss,and corrosion.The primary goal of this study is to describe the structural disparities between both types of bridges and evaluate their structural redundancies by employing deterministic and nondeterministic methods.To achieve this goal,three-dimensional finite-element models of both bridges were developed based on the current design guidelines for stay cables in Japan.After the balanced states of the bridge models were achieved,static analyses were performed for different safety factors of stay cables in a parametric manner.Finally,the first-order reliability method and Monte Carlo method were applied to determine the reliability index of stay cables.The analysis results show that cable-stayed and extradosed bridges exhibit different structural redundancies for different safety factors under the same loading conditions.Moreover,a significant increase in structural redundancy occurs with an incremental increase in the safety factors of stay cables. 展开更多
关键词 cable-stayed bridge Extradosed bridge REDUNDANCY stay cable Safety factor Reliability analysis
下载PDF
Parametrically excited oscillation of stay cable and its control in cable-stayed bridges" 被引量:2
2
作者 孙炳楠 汪至刚 +1 位作者 高赞明 倪一清 《Journal of Zhejiang University Science》 EI CSCD 2003年第1期13-20,共8页
This paper presents a nonlinear dynamic model for simulation and analysis of a kind of parametrically excited vibration of stay cable caused by support motion in cable-stayed bridges. The sag, inclination angle of the... This paper presents a nonlinear dynamic model for simulation and analysis of a kind of parametrically excited vibration of stay cable caused by support motion in cable-stayed bridges. The sag, inclination angle of the stay cable are considered in the model, based on which, the oscillation mechanism and dynamic response characteristics of this kind of vibration are analyzed through numerical calculation. It is noted that parametrically excited oscillation of a stay cable with certain sag, inclination angle and initial static tension force may occur in cable-stayed bridges due to deck vibration under the condition that the natural frequency of a cable approaches to about half of the first model frequency of the bridge deck system. A new vibration control system installed on the cable anchorage is proposed as a possible damping system to suppress the cable parametric oscillation. The numerical calculation results showed that with the use of this damping system, the cable oscillation due to the vibration of the deck and/or towers will be considerably reduced. 展开更多
关键词 stay cable cable stayed bridge Parametric vibration Vibration control Support excitation
下载PDF
Nonlinear dynamic response of stay cables under axial harmonic excitation 被引量:2
3
作者 Xu XIE He ZHANG Zhi-cheng ZHANG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第9期1193-1200,共8页
This paper proposes a new numerical simulation method for analyzing the parametric vibration of stay cables based on the theory of nonlinear dynamic response of structures under the asynchronous support excitation. Th... This paper proposes a new numerical simulation method for analyzing the parametric vibration of stay cables based on the theory of nonlinear dynamic response of structures under the asynchronous support excitation. The effects of important pa- rameters related to parametric vibration of cables, i.e., characteristics of structure, excitation frequency, excitation amplitude, damping effect of the air and the viscous damping coefficient of the cables, were investigated by using the proposed method for the cables with significant length difference as examples. The analysis results show that nonlinear finite element method is a powerful technique in analyzing the parametric vibration of cables, the behavior of parametric vibration of the two cables with different Irvine parameters has similar properties, the amplitudes of parametric vibration of cables are related to the frequency and amplitude of harmonic support excitations and the effect of distributed viscous damping on parametric vibration of the cables is very small. 展开更多
关键词 stay cables Parametric vibration Nonlinear vibration Viscous damping
下载PDF
A simplified fragility analysis of fan type cable stayed bridges 被引量:1
4
作者 R. A. Khan T. K. Datta S. Ahmad 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第1期83-94,共12页
A simplified fragility analysis of fan type cable stayed bridges usingProbabilistic Risk Analysis (PRA) procedure is presented for determining their failure probabilityunder random ground motion. Seismic input to the ... A simplified fragility analysis of fan type cable stayed bridges usingProbabilistic Risk Analysis (PRA) procedure is presented for determining their failure probabilityunder random ground motion. Seismic input to the bridge support is considered to be a riskconsistent response spectrum which is obtained from a separate analysis. For the response analysis,the bridge deck is modeled as a beam supported on springs at different points. The stiffnesses ofthe springs are determined by a separate 2D static analysis of cable-tower-deck system. The analysisprovides a coupled stiffness matrix for the spring system. A continuum method of analysis usingdynamic stiffness is Used to determine the dynamic properties of the bridges .The response of thebridge deck is obtained by the response spectrum method of analysis as applied to multi-degree offreedom system which duly takes into account the quasi - static component of bridge deck vibration.The fragility analysis includes uncertainties arising due to the variation in ground motion,material property, modeling, method of analysis, ductility factor and damage concentration effect.Probability of failure of the bridge deck is determined by the First Order Second Moment (FOSM)method of reliability. A three span double plane symmetrical fan type cable stayed bridge of totalspan 689 m, is used as an illustrative example. The fragility curves for the bridge deck failure areobtained under a number of parametric variations. Some of the important conclusions of the studyindicate that (ⅰ) not only vertical component but also the horizontal component of ground motionhas considerable effect on the probability of failure; (ⅱ) ground motion with no time lag betweensupport excitations provides a smaller probability of failure as compared to ground motion with verylarge time lag between support excitation; and (ⅲ) probability of failure may considerablyincrease for soft soil condition. 展开更多
关键词 probabilistic risk analysis fan type cable stayed bridge fragilityanalysis first order second moment
下载PDF
Calculation model and mechanism analysis for rain-wind-induced vibration of stay cable 被引量:1
5
作者 谢桂华 刘荣桂 +1 位作者 蔡东升 陈蓓 《Journal of Central South University》 SCIE EI CAS 2014年第3期1107-1114,共8页
Rain-wind-induced vibration of cable was studied based on previous research achievements. According to the quasi-steady assumption, the governing equation of vertical motion of the cable was derived and the criterion ... Rain-wind-induced vibration of cable was studied based on previous research achievements. According to the quasi-steady assumption, the governing equation of vertical motion of the cable was derived and the criterion for unstable motion and occurrence mechanism was studied. A comparison was performed between the oscillation responses of the stay cable obtained from calculated model and previous results. The results indicate that the analysis model can reflect the main characteristics of wind-rain-induced vibrationt of the cable which is amplitude- and velocity-restricted, and it is probably related with the periodic vortex shedding of wake flow. It is essential for the occurrence of rain-wind-induced or wind-induced vibration of cable that the derivative of lift coefficient with respect to transient angle of attack is less than zero. When rain-wind-induced vibration occurs, the aerodynamic force has a dual function for the vibration, and the maximum amplitude of stayed-cable is determined by the relative value of aerodynamic exciting force and aerodynamic damping force. 展开更多
关键词 rain-wind-induced vibration stay cable governing equation STABILITY vortex shedding
下载PDF
NONLINEAR TRANSIENT RESPONSE OF STAY CABLE WITH VISCOELASTICITY DAMPER IN CABLE-STAYED BRIDGE 被引量:1
6
作者 陈水生 孙炳楠 冯义卿 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2004年第6期664-671,共8页
Taking the bending stiffness, static sag, and geometric non-linearity into consideration, the space nonlinear vibration partial differential equations were derived. The partical differential equations were discretized... Taking the bending stiffness, static sag, and geometric non-linearity into consideration, the space nonlinear vibration partial differential equations were derived. The partical differential equations were discretized in space by finite center difference approximation, then the nonlinear ordinal differential equations were obtained. A hybrid method involving the combination of the Newmark method and the pseudo-force strategy was proposed to analyze the nonlinear transient response of the inclined cable-dampers system subjected to arbitrary dynamic loading. As an example, two typical stay cables were calculated by the present method. The results reveal both the validity and the deficiency of the viscoelasticity damper for vibration control of stay cables. The efficiency and accuracy of the proposed method is also verified by comparing the results with those obtained by using Runge-Kutta direct integration technique. A new time history analysis method is provided for the research on the stay cable vibration control. 展开更多
关键词 stay cable transient response vibration control non-linearity
下载PDF
Study on longitudinal wind load calculation method of cables for cable-stayed bridge 被引量:2
7
作者 Pei Minshan Zhang Xigang Zhu Bin Hou Bin Liu Changpeng 《Engineering Sciences》 EI 2009年第1期18-22,58,共6页
Along with the expanding of span of cable-stayed bridge,wind load becomes a more and more important controlling factor for bridge the design.A very large proportion of the wind load acting on cables has exceeded that ... Along with the expanding of span of cable-stayed bridge,wind load becomes a more and more important controlling factor for bridge the design.A very large proportion of the wind load acting on cables has exceeded that acting on deck.There was not any detailed prescript in Chinese code for calculation of longitudinal wind load on cables due to lack of theoretical research and experiment,and conservative simplified calculation was adopted during design,which leads to conservative and uneconomical design of structures.To resolve this problem,cable force experiment was carried out during the design of Sutong Bridge.By comparing with international research results,the calculation formula of longitudinal wind drag coefficient for cables was advanced to fill the blank of bridge wind resistant code of China,and has already been adopted in the Highway Bridge Wind Resistant Design Code(JTG/T D60-01-2004)with great significance for bridge engineering. 展开更多
关键词 cable-stayed bridge stayed cable longitudinal wind load
下载PDF
Nonlinear Dynamic Reliability of Coupled Stay Cables and Bridge Tower
8
作者 余建星 田佳 +3 位作者 董文斌 丁宁 杨晓蓉 谭振东 《Transactions of Tianjin University》 EI CAS 2007年第5期334-339,共6页
Nonlinear vibration can cause serious problems in long span cable-stayed bridges.When the internal resonance threshold is reached between the excitation frequency and natural frequency,large amplitudes occur in the ca... Nonlinear vibration can cause serious problems in long span cable-stayed bridges.When the internal resonance threshold is reached between the excitation frequency and natural frequency,large amplitudes occur in the cable.Based on the current situation of lacking corresponding constraint criteria,a model was presented for analyzing the dynamic reliability of coupling oscillation between the cable and tower in a cable-stayed bridge.First of all,in the case of cable sag,the d'Alembert principle is applied to studying the nonlinear dynamic behavior of the structure,and resonance failure interval of parametric oscillation is calculated accordingly.Then the dynamic reliability model is set up using the JC method.An application of this model has been developed for the preliminary design of one cable-stayed bridge located on Hai River in Tianjin,and time histories analysis as well as reliability indexes have been obtained.When frequency ratio between the cable and tower is approaching 1∶2,the reliability index is 0.98,indicating high failure probability.And this is consistent with theoretical derivation and experimental results in reference.This model,which is capable of computing the reliability index of resonance failure,provides theoretical basis for the establishment of corresponding rule. 展开更多
关键词 cable-stayed bridge stay cable nonlinear vibration internal resonance parametric vibration dynamic reliability
下载PDF
Study on Fatigue Behavior of Anchorage of Cable and Girder of Long Span Cable-Stayed Bridge
9
作者 刘庆宽 强士中 张强 《Journal of Modern Transportation》 2001年第1期42-49,共8页
A full scale model test is done and a FEM model is established to investigate the fatigue behavior of the Nancha cable stayed bridge of the Nanjing Second Yangtz River Bridge, a long span steel bridge with a main sp... A full scale model test is done and a FEM model is established to investigate the fatigue behavior of the Nancha cable stayed bridge of the Nanjing Second Yangtz River Bridge, a long span steel bridge with a main span of 628 m. The results of test and FEM are analyzed and compared. It is shown that they are in good agreement. It is verified that the fatigue characteristic of the anchorage structure of cable and girder of the bridge satisfies the requirements specified by Chinese, British and American codes. 展开更多
关键词 cable stayed bridges anchorage of cable and girder FATIGUE
下载PDF
Closure technique for the hybrid girder cable stayed bridge of Edong Bridge
10
作者 Liu Minghu Tan Hao +1 位作者 Xu GuoPing Zhao Canhui 《Engineering Sciences》 EI 2012年第4期51-56,共6页
Based on Edong Yangtze River Bridge, which is the second longest hybrid girder cable stayed bridge with 926 m long main span, the influencing factors and crucial techniques of the main span closure method for long spa... Based on Edong Yangtze River Bridge, which is the second longest hybrid girder cable stayed bridge with 926 m long main span, the influencing factors and crucial techniques of the main span closure method for long span hybrid girder cable stayed bridge are studied. After theoretical analysis, numerical evaluation and practical test, the loading assistant closure method is employed in Edong Yangtze River Bridge. The loading assistant closure method, with better thermal adaptability and less influence on bridge line and the forced status, can meet the requirements of the unstressed state control method. Based on the mentioned advantages, the loading assistant closure method is applicable to long span hybrid girder cable stayed bridges. The conclusion can provide a reference for the further design of the similar brid^es. 展开更多
关键词 Edong Bridge hybrid girder cable stayed bridge closure technique loading assistant closure method unstressed state control method
下载PDF
Hardware-in-the-Loop Simulation of Vibration Control of Stay Cables with Damper Based on dSPACE System
11
作者 ZHOU Qunmei CHENG Pengju PENG Wei 《Journal of Donghua University(English Edition)》 CAS 2021年第3期257-263,共7页
A simple and economical method based on dSPACE system is developed to measure the effect of cable vibration control.The experiments,numerical simulation and hardware-in-the-loop(HIL)simulation are carried out for the ... A simple and economical method based on dSPACE system is developed to measure the effect of cable vibration control.The experiments,numerical simulation and hardware-in-the-loop(HIL)simulation are carried out for the vibration control of stay cables with dampers.Firstly,the test results of solid cable vibration under harmonic excitation are compared with the numerical simulation results of cable vibration to ensure the correctness of the simulation of cable module.Then,the vibration test results of solid cable with damper under harmonic excitation are compared with the numerical simulation results of solid cable with damper to ensure the correctness of the relevant modules.Finally,the external load and the cable are imported into the real-time simulation system to simulate the control effect of the damper under the current excitation in real time.The results show that the simulation is correct and the HIL simulation is feasible in the bridge engineering. 展开更多
关键词 stay cable vibration control dSPACE system hardware-in-the-loop(HIL)simulation
下载PDF
Rain-Wind Induced Vibration Mitigation of Stay Cables by Aerodynamic Means
12
作者 赵军 李明水 廖海黎 《Journal of Southwest Jiaotong University(English Edition)》 2009年第1期54-57,共4页
Stay cables with various surface profiles were tested in wind tunnel. Dimples and helical fillets were applied to mitigate the rain- wind induced vibration. The rain-wind excited responses of the cable with smooth sur... Stay cables with various surface profiles were tested in wind tunnel. Dimples and helical fillets were applied to mitigate the rain- wind induced vibration. The rain-wind excited responses of the cable with smooth surface were larger than those of the cables with dimples and helical fillets. At high Reynolds number, the drag coefficients of cables with dimples and helical fillets are much larger than those of smooth surface cable. 展开更多
关键词 Rain-wind induced vibration Wind tunnel test stay cable MITIGATION
下载PDF
Study on Vibration Characteristics of Stay Cable-Nonlinear Viscous Damper System
13
作者 Xiaolong Li Kai Zhao 《Open Journal of Civil Engineering》 2022年第2期153-168,共16页
Tension cables are easily prone to generating varied vibrations under the action of external loads, which adversely affects the safety of bridges. Therefore, it is necessary to take effective measures to suppress the ... Tension cables are easily prone to generating varied vibrations under the action of external loads, which adversely affects the safety of bridges. Therefore, it is necessary to take effective measures to suppress the vibrations of tension cables. Cable end dampers are widely used in vibration reduction for cable-stayed bridges due to their convenient installation and low costs. However, the previous studies on the tension cable-viscous damper systems mostly adopt the linear method, and the weakening effect of the flexibility of mounting brackets on the damper vibration reduction is not sufficiently taken into account. Therefore, this paper adopts the improved Kelvin model to conduct the derivation, solution, and parametric analysis of vibration equations for the stay cable-nonlinear viscous damper systems. The results of parametric analysis show that the maximum modal damping ratio that can be obtained by cables and the corresponding optimal damping coefficient of dampers are correlated with the damping nonlinear coefficient α, stiffness nonlinear coefficient β, vibration order n, installation position a/L, and stiffness coefficient μ, etc.;among them, n damping nonlinear coefficient α and stiffness nonlinear coefficient β are the key parameters that affect the parameter design of dampers, where damping nonlinear coefficient α mainly controls the optimal damping coefficient and stiffness nonlinear coefficient β mainly controls the maximum damping ratio. Based on the parametric analysis, the design principles of dampers and value requirements of key parameters under different vibration suppression objectives are presented. 展开更多
关键词 stay cable VIBRATION Nonlinear Viscous Damper Damper Design Method Parametric Analysis
下载PDF
Wind-Tunnel Investigation of the Aerodynamic Performance of Surface-Modification Cables 被引量:2
14
作者 Hiroshi Katsuchi Hitoshi Yamada +1 位作者 Ippei Sakaki Eiichi Okado 《Engineering》 SCIE EI 2017年第6期817-822,共6页
The wind-induced vibration of stay cables of cable-stayed bridges, which includes rain-wind-induced vibration (RWIV) and dry galloping (DG), has been studied for a considerable amount of time. In general, mechanic... The wind-induced vibration of stay cables of cable-stayed bridges, which includes rain-wind-induced vibration (RWIV) and dry galloping (DG), has been studied for a considerable amount of time. In general, mechanical dampers or surface modification are applied to suppress the vibration. In particular, several types of surface-modification cable, including indentation, longitudinally parallel protuberance, helical fillet, and U-shaped grooving, have been developed. Recently, a new type of aerodynamically stable cable with spiral protuberances was developed. It was confirmed that the cable has a low drag force coefficient, like an indented cable, and that it prevented the formation of water rivulets on the cable surface. In this study, the stability for RWIV of this cable was investigated with various flow angles and protuberance dimensions in a wind-tunnel test. It was found that the spiral protuberance cable is aerodynamically stable against both RWIV and DG for all test wind angles. The effects of the protuberance dimensions were also clarified. 展开更多
关键词 Rain-wind-induced vibration Dry galloping stay cable Wind-tunnel test
下载PDF
Modeling and Experiments of Spray System for Cable Painting Robot
15
作者 张家梁 吕恬生 李蓓智 《Journal of Donghua University(English Edition)》 EI CAS 2008年第4期355-360,共6页
Many cable-stayed bridges have been built in the world in the past decades,and cable-stayed structures have been adopted in many large constructions.The cable painting robot is safe and economically efficient for stay... Many cable-stayed bridges have been built in the world in the past decades,and cable-stayed structures have been adopted in many large constructions.The cable painting robot is safe and economically efficient for stay cable maintenance.In order to satisfy the need for spraying cables in high attitude,an automatic cable spray system for cable painting robots is presented in this paper.Using the β distribution,paint thickness distribution on a cylinder surface is modeled.The spray gun's number,angle and movement are analyzed to get coat evenness.Then a robotic spray system engineering prototype has been developed,which includes a cable electric running climbing base,a spray cover,four airless spray guns and a pressurized paint container.Experiments indicate that four airless spray guns can guarantee good coat quality for general stay cables.The field tests have been successfully conducted on Nanpu Bridge,Shanghai. 展开更多
关键词 ROBOT stay cable spray painting MODELLING
下载PDF
Stochastic optimal control of cable vibration in plane by using axial support motion
16
作者 Ming Zhao Wei-Qiu Zhu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2011年第4期578-586,共9页
A stochastic optimal control strategy for a slightly sagged cable using support motion in the cable axial direction is proposed. The nonlinear equation of cable motion in plane is derived and reduced to the equations ... A stochastic optimal control strategy for a slightly sagged cable using support motion in the cable axial direction is proposed. The nonlinear equation of cable motion in plane is derived and reduced to the equations for the first two modes of cable vibration by using the Galerkin method. The partially averaged Ito equation for controlled system energy is further derived by applying the stochastic averaging method for quasi-non-integrable Hamiltonian systems. The dynamical programming equation for the controlled system energy with a performance index is established by applying the stochastic dynamical programming principle and a stochastic optimal control law is obtained through solving the dynamical programming equation. A bilinear controller by using the direct method of Lyapunov is introduced. The comparison between the two controllers shows that the proposed stochastic optimal control strategy is superior to the bilinear control strategy in terms of higher control effectiveness and efficiency. 展开更多
关键词 stay cable Active control - Stochastic optimalcontrol Dynamical programming principle
下载PDF
Vehicle-bridge coupled vibrations in different types of cable stayed bridges 被引量:3
17
作者 Lingbo WANG Peiwen JIANG +3 位作者 Zhentao HUI Yinping MA Kai LIU Xin KANG 《Frontiers of Structural and Civil Engineering》 EI CSCD 2016年第1期81-92,共12页
Numerical analyses of the coupled vibrations of vehicle-bridge system and the effects of different types of cable stayed bridges on the coupled vibration responses have been presented in this paper using ANSYS. The br... Numerical analyses of the coupled vibrations of vehicle-bridge system and the effects of different types of cable stayed bridges on the coupled vibration responses have been presented in this paper using ANSYS. The bridge model and vehicle model were independently built which have no internal relationship in the ANSYS. The vehicle-bridge coupled vibration relationship was obtained by using the APDL program which subsequently imposed on the vehicle and bridge models during the numerical analysis. The proposed model was validated through a field measurements and literature data. The judging method, possibility, and criterion of the vehicle-bridge resonance (coupled vibrations) of cable stayed bridges (both the floating system and half floating system) under traffic flows were presented. The results indicated that the interval time between vehicles is the main influence factor on the resonance excitation frequency under the condition of equally spaced traffic flows. Compared to other types of cable stayed bridges, the floating bridge system has relatively high possibility to cause vehicle-bridge resonance. 展开更多
关键词 vehicle-bridge coupled vibration cable stayed bridge resonances of vehicle-bridge system
原文传递
A videogrammetric technique for measuring the vibration displacement of stay cables 被引量:2
18
作者 ZHOU Xiaoqing XIA Yong +1 位作者 WEI Zelong WU Qingxiong 《Geo-Spatial Information Science》 SCIE EI 2012年第2期135-141,共7页
Stay cables in cable-stayed bridges are prone to large amplitude oscillations under external excitations.The vibration of the cables is predominantly measured by using accelerometers to measure the acceleration.The dy... Stay cables in cable-stayed bridges are prone to large amplitude oscillations under external excitations.The vibration of the cables is predominantly measured by using accelerometers to measure the acceleration.The dynamic displacement is then usually obtained indirectly from the double integration of the acceleration data.This paper reports an experimental method of measuring the displacement of stayed cables using a digital video camera.With the newly developed videogrammetric technique,the video clips are transferred into image frames,from which the shape and location of the target are identified.The displacement time history is then captured.The technique is applied to a cable-stayed bridge to measure the dynamic displacement of stay cables.The displacement is compared with the acceleration data in the frequency and time domains.The results show that the displacement measured by the digital video camera is comparable to the counterparts integrated from the acceleration data.The vibration frequencies identified from the acceleration are finally used to estimate the tension forces of the cables.The results show that the tension forces have insignificant changes after one year’s operation. 展开更多
关键词 stay cable VIBRATION displacement measurement videogrammetric technique tension force
原文传递
Vortex-induced vibration of stay cable under profile velocity using CFD numerical simulation method 被引量:1
19
作者 Wenli CHEN Hui LI 《Frontiers of Structural and Civil Engineering》 SCIE EI 2009年第4期357-363,共7页
Vortex-induced vibration(VIV)of a stay cablesubjected to a wind profile is numerically simulatedthrough combining computational fluid dynamics(CFD)code CFX 10.0 and computational structural dynamics(CSD)code ANSYS 10.... Vortex-induced vibration(VIV)of a stay cablesubjected to a wind profile is numerically simulatedthrough combining computational fluid dynamics(CFD)code CFX 10.0 and computational structural dynamics(CSD)code ANSYS 10.0.A stay cable with the inclinedangle of 30°is used as the numerical model.Under aprofile of mean wind speed,unsteady aerodynamic liftcoefficients of the cable have been analyzed in both timedomain and frequency domain when VIV occurs.Theresults indicate that the lift coefficient wave response of thestay cable under a wind profile is different from that of aninfinitely long cable under a uniform flow in water(i.e.,without consideration of profile)obtained by directnumerical simulation.Cable oscillations can severelyaffect the unsteady aerodynamic frequencies,changeflow field distribution near the cable and affect the vortexshedding in the wake. 展开更多
关键词 stay cable fluid-structure interaction numerical simulation vortex-induced vibration
原文传递
Key Technologies for Design of Changqing Yellow River Super-long Bridge of Zhengzhou Ji'nan HSR
20
作者 ZUO Jiaqiang ZHANG Shang +3 位作者 MA Chenlong WANG Zongfeng ZHANG Hai ZHENG Mingda(Translated) 《Chinese Railways》 2023年第2期3-11,共9页
Changqing Yellow River Super-long Bridge of Zhengzhou-Ji'nan HSR is a partial cable-stayed bridge with concrete main girder and a unit length of 1,080 m.Studies are carried out on the key technologies of bridge de... Changqing Yellow River Super-long Bridge of Zhengzhou-Ji'nan HSR is a partial cable-stayed bridge with concrete main girder and a unit length of 1,080 m.Studies are carried out on the key technologies of bridge design,and the main conclusions are as follows:The whole unit adopts the supporting system of tower pier consolidation and tower-beam separation,and each pier is provided with seismic mitigation and isolation bearing;shaped-steel reinforced concrete bridge tower is adopted to bring into full play the tensile performance of steel and the compressive performance of concrete,and avoid the construction challenges of setting up multi-layer and multi-stirrup reinforcement while improving the bearing capacity of section;a new type of double-side and bi-directional anti-skid anchorage device is adopted for the cable saddle of wire divider pipe in order to withstand the unbalanced cable force,and verify the reliability of the anti-skid anchorage device by solid model test;and large-segment cantilever pouring design is adopted for the main girder with a maximum segment length of 8 m to effectively shorten the construction period of the bridge. 展开更多
关键词 Zhengzhou-Ji'nan HSR Changqing Yellow River Super-long Bridge partial cable stayed bridge multi-tower cable-stayed bridge multiple span and long connection bridge design
下载PDF
上一页 1 2 下一页 到第