CFG pile (i.e., pile constructed by granular materials of cement, fly-ash and gravel) composite foundation is applied in subsoil treatment widely and successfully. In order to have a further study of this kind of subs...CFG pile (i.e., pile constructed by granular materials of cement, fly-ash and gravel) composite foundation is applied in subsoil treatment widely and successfully. In order to have a further study of this kind of subsoil treatment technology, the influencing factors and calculation methods of the vertical bearing capacity of single CFG pile and the CFG pile composite foundation were discussed respectively. And based on the obtained solutions, effects by the cushion and measurements to reduce negative friction area were analyzed. Moreover, the developing law of settlement and bearing capacity eigenvalue controlled by the material strength with the increase of load were given for the CFG composite foundation. The in-situ static load test was tested for CFG pile. The results of test show that the maximum test load or half of the ultimate load is used from all the points of test, the average bearing capacity eigenvalue of single pile is 390 kN, and slightly greater than the design value of bearing capacity. The bearing capacity eigenvalues of composite foundation for 3 piles are greater than 300 kPa, and the mechanical properties of CFG pile composite foundation are almost identical in the case of the same load and cushion thickness. The pile-soil stress ratio and the load-sharing ratio can be adjusted through setting up cushion thickness.展开更多
The load transfer analytical method is applied to study the bearing mechanism of piles with vertical load in this paper. According to the different hardening rules of soil or rock around the pile shaft, such as work-s...The load transfer analytical method is applied to study the bearing mechanism of piles with vertical load in this paper. According to the different hardening rules of soil or rock around the pile shaft, such as work-softening, ideal elasto-plastic and work-hardening, a universal tri-linear load transfer model is suggested for the development of side and tip resistance by various types of soil (rock) with the consideration of sediment at the bottom of the pile. Based on the model, a formula is derived for the relationship between the settlement and load on the pile top to determine the vertical bearing capacity, taking into account such factors as the characteristics of the stratum, the side resistance along the shaft, and tip resistance under the pile tip. A close agreement of the calculated results with the measured data from a field test pile lends confidence to the future application of the present approach in engineering practice.展开更多
To optimize the distance between the bells in pile design,this paper reports a series of small scale tests on the uplift capacity of double belled piles embedded in dry dense sand considering different bell space rati...To optimize the distance between the bells in pile design,this paper reports a series of small scale tests on the uplift capacity of double belled piles embedded in dry dense sand considering different bell space ratios.Finite element modelling is also performed to evaluate the range of soil failure around the piles during pile uplift displacement.Test results show that when bell space ratio is 6 or 8,the uplift capacity reaches the peak value.The upper bell bears more load than the lower one for the piles with bell space ratio less than 6,while the lower bell bears more load than the upper one for the piles with bell space ratio larger than 8.展开更多
A pile foundation is commonly adopted in geotechnical engineering to support structures, and its application has been extended to cold-regions engineering. In past decades, a host of scholars investigated pile behavio...A pile foundation is commonly adopted in geotechnical engineering to support structures, and its application has been extended to cold-regions engineering. In past decades, a host of scholars investigated pile behaviors and proposed design guidelines for seasonally frozen ground or permafrost. This paper reviews the research with respect to pile performance and engineering practice in cold regions, organized as follows:(1) creep tests and bearing capacity,(2) frost-jacking hazards,(3) laterally loaded piles,(4) dynamic responses,(5) refreezing due to concrete-hydration heat, and(6) improved countermeasures and design methods. We first summarize previous research and recent progress; then, predict the development trend of pile foundations in cold regions and recommend further research.展开更多
In this study,we propose a drainage pipe pile under vacuum consolidation to integrate foundation treatment and pile foundation engineering in soft soil areas.To study its bearing capacity characteristics and foundatio...In this study,we propose a drainage pipe pile under vacuum consolidation to integrate foundation treatment and pile foundation engineering in soft soil areas.To study its bearing capacity characteristics and foundation treatment performance,single pile static load tests,vane shear tests,and water content tests were carried out for ordinary piles,perforated piles,and drainage pipe piles under conditions of static and vacuum consolidation.Based on the results,the concept of strong and weak reinforcement areas was proposed and used for bearing capacity prediction.The results showed that the drainage pipe pile did not become silted under vacuum consolidation.The single pile bearing capacity was much higher than that of an ordinary pile,and the pile side friction was exerted mainly in the middle and lower parts.Good results were achieved using the shear strength at the junction of the strong and weak reinforcement areas to estimate the ultimate bearing capacity of a single pile.This study provided important insights into the design and construction of drainage pipe piles in a soft soil foundation.展开更多
基金Project(08JJ3111) supported by the Natural Science Foundation of Hunan ProvinceProject(08B025) supported by Scientific Research Fund of Hunan Provincial Education DepartmentProject(2006AA11Z104) supported by the National High-Tech Research and Development Program of China
文摘CFG pile (i.e., pile constructed by granular materials of cement, fly-ash and gravel) composite foundation is applied in subsoil treatment widely and successfully. In order to have a further study of this kind of subsoil treatment technology, the influencing factors and calculation methods of the vertical bearing capacity of single CFG pile and the CFG pile composite foundation were discussed respectively. And based on the obtained solutions, effects by the cushion and measurements to reduce negative friction area were analyzed. Moreover, the developing law of settlement and bearing capacity eigenvalue controlled by the material strength with the increase of load were given for the CFG composite foundation. The in-situ static load test was tested for CFG pile. The results of test show that the maximum test load or half of the ultimate load is used from all the points of test, the average bearing capacity eigenvalue of single pile is 390 kN, and slightly greater than the design value of bearing capacity. The bearing capacity eigenvalues of composite foundation for 3 piles are greater than 300 kPa, and the mechanical properties of CFG pile composite foundation are almost identical in the case of the same load and cushion thickness. The pile-soil stress ratio and the load-sharing ratio can be adjusted through setting up cushion thickness.
文摘The load transfer analytical method is applied to study the bearing mechanism of piles with vertical load in this paper. According to the different hardening rules of soil or rock around the pile shaft, such as work-softening, ideal elasto-plastic and work-hardening, a universal tri-linear load transfer model is suggested for the development of side and tip resistance by various types of soil (rock) with the consideration of sediment at the bottom of the pile. Based on the model, a formula is derived for the relationship between the settlement and load on the pile top to determine the vertical bearing capacity, taking into account such factors as the characteristics of the stratum, the side resistance along the shaft, and tip resistance under the pile tip. A close agreement of the calculated results with the measured data from a field test pile lends confidence to the future application of the present approach in engineering practice.
基金Project(51778346) supported by the National Natural Science Foundation of ChinaProject(2019GSF111007) supported by the Key Research and Development Project of Shandong Province of China+1 种基金Project(ZR201808040034) supported by the Natural Science Foundation of Shandong Province of ChinaProject(2015RCJJ010) supported by the Talent Introduction Research Start-up Fund Project of Shandong University of Science and Technology,China。
文摘To optimize the distance between the bells in pile design,this paper reports a series of small scale tests on the uplift capacity of double belled piles embedded in dry dense sand considering different bell space ratios.Finite element modelling is also performed to evaluate the range of soil failure around the piles during pile uplift displacement.Test results show that when bell space ratio is 6 or 8,the uplift capacity reaches the peak value.The upper bell bears more load than the lower one for the piles with bell space ratio less than 6,while the lower bell bears more load than the upper one for the piles with bell space ratio larger than 8.
基金supported by the National Natural Science Foundation of China(Grant Nos.41731281and 41771073)
文摘A pile foundation is commonly adopted in geotechnical engineering to support structures, and its application has been extended to cold-regions engineering. In past decades, a host of scholars investigated pile behaviors and proposed design guidelines for seasonally frozen ground or permafrost. This paper reviews the research with respect to pile performance and engineering practice in cold regions, organized as follows:(1) creep tests and bearing capacity,(2) frost-jacking hazards,(3) laterally loaded piles,(4) dynamic responses,(5) refreezing due to concrete-hydration heat, and(6) improved countermeasures and design methods. We first summarize previous research and recent progress; then, predict the development trend of pile foundations in cold regions and recommend further research.
基金supported by the Key Water Science and Technology Project of Zhejiang Province(No.RB2027)the Zhejiang Provincial Public Welfare Technology Application Research Project(No.LGG22E080002),China。
文摘In this study,we propose a drainage pipe pile under vacuum consolidation to integrate foundation treatment and pile foundation engineering in soft soil areas.To study its bearing capacity characteristics and foundation treatment performance,single pile static load tests,vane shear tests,and water content tests were carried out for ordinary piles,perforated piles,and drainage pipe piles under conditions of static and vacuum consolidation.Based on the results,the concept of strong and weak reinforcement areas was proposed and used for bearing capacity prediction.The results showed that the drainage pipe pile did not become silted under vacuum consolidation.The single pile bearing capacity was much higher than that of an ordinary pile,and the pile side friction was exerted mainly in the middle and lower parts.Good results were achieved using the shear strength at the junction of the strong and weak reinforcement areas to estimate the ultimate bearing capacity of a single pile.This study provided important insights into the design and construction of drainage pipe piles in a soft soil foundation.