A radiant source with a large aperture at 5--95℃ in the wavelength bands of 8--12μm for calibrating infrared imaging systems has been designed. The effective emissivity of its flat bottom with concentric V-grooves w...A radiant source with a large aperture at 5--95℃ in the wavelength bands of 8--12μm for calibrating infrared imaging systems has been designed. The effective emissivity of its flat bottom with concentric V-grooves was evaluated by the Monte-Carlo method whose correctness was tested and accuracy was discussed. The structure of the source was completed by incorporating the simulation results with the blackbody cavity effect. The source was certificated via an optical measurement system. The source can provide a consistent radiant flux with temperature uniformity of ±0.1℃ over an area of diameter of φ80 mm.展开更多
In the surface imaging of underwater structures, long working distance will reduce image quality due to the turbidity of water. To acquire high definition and large field of view(FOV) images for surface detection, a s...In the surface imaging of underwater structures, long working distance will reduce image quality due to the turbidity of water. To acquire high definition and large field of view(FOV) images for surface detection, a short-working-distance underwater imaging system is proposed based on camera array. A multi-view calibration and rectification method is developed. A look-up table(LUT) method and a multi-resolution spline(MRS) method are applied to stitch array images real-time and seamlessly.Experiments both in the air and in the water are conducted. Strength and weakness of the LUT and MRS methods are discussed.Based on the results, the effectiveness in surface detection of underwater structures is verified.展开更多
基金This work was supported by the National Natural Science Foundation of China under Grant No. 50336010.
文摘A radiant source with a large aperture at 5--95℃ in the wavelength bands of 8--12μm for calibrating infrared imaging systems has been designed. The effective emissivity of its flat bottom with concentric V-grooves was evaluated by the Monte-Carlo method whose correctness was tested and accuracy was discussed. The structure of the source was completed by incorporating the simulation results with the blackbody cavity effect. The source was certificated via an optical measurement system. The source can provide a consistent radiant flux with temperature uniformity of ±0.1℃ over an area of diameter of φ80 mm.
基金supported by the National Key Technology R&D Program(Grant No.2014BAK11B04)the National Natural Science Foundation of China(Grant Nos.11272089,11327201,11532005&11602056)
文摘In the surface imaging of underwater structures, long working distance will reduce image quality due to the turbidity of water. To acquire high definition and large field of view(FOV) images for surface detection, a short-working-distance underwater imaging system is proposed based on camera array. A multi-view calibration and rectification method is developed. A look-up table(LUT) method and a multi-resolution spline(MRS) method are applied to stitch array images real-time and seamlessly.Experiments both in the air and in the water are conducted. Strength and weakness of the LUT and MRS methods are discussed.Based on the results, the effectiveness in surface detection of underwater structures is verified.