Event plane determination from the zero degree calorimeter at the cooling storage ring external-target experiment
1
作者 Li-Ke Liu Hua Pei +3 位作者 Ya-Ping Wang Biao Zhang Nu Xu Shu-Su Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第7期113-121,共9页
The Cooling Storage Ring external-target experiment(CEE)spectrometer is used to study the nuclear matter created in heavy-ion collisions at√sNN=2.1-2.4 GeV with the aim to reveal the quantum chromodynamics phase stru... The Cooling Storage Ring external-target experiment(CEE)spectrometer is used to study the nuclear matter created in heavy-ion collisions at√sNN=2.1-2.4 GeV with the aim to reveal the quantum chromodynamics phase structure in the high-baryon-density region.Collective flow is considered an effective probe for evaluating the properties of media during high-energy nuclear collisions.One of the main functions of the zero-degree calorimeter(ZDC),a subdetector system in the CEE,is to determine the reaction plane in heavy-ion collisions.This step is crucial for measuring the collective flow and other reaction-plane-related analyses.In this paper,we illustrate the procedures for event plane determination using the ZDC.Finally,isospin-dependent quantum molecular dynamics model-based predictions of the rapidity dependence of the directed and elliptical flows for p,d,t,3He,and 4He,produced in 2.1 GeV U+U collisions,are presented. 展开更多
关键词 QCD phase structure Heavy-ion collisions Collective flow Reaction plane Zero-degree calorimeter
下载PDF
Design of a high-dynamic-range prototype readout system for VLAST calorimeter
2
作者 Qiang Wan Jian-Hua Guo +10 位作者 Xing Xu Shen Wang Yong-Qiang Zhang Yi-Ming Hu Yan Zhang Xu Pan Xiang Li Chuan Yue Wei Jiang Yu-Xin Cui Deng-Yi Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第10期47-59,共13页
In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-ene... In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6. 展开更多
关键词 VLAST calorimeter Readout system Front-end electronics Large dynamic range
下载PDF
Study of Complexes of Lanthanum with Amino Acids by Titration Calorimeter 被引量:2
3
作者 Ye Gang, Wang Cun-xin, Qu Song-sheng College of Chemistry and Environment Science, Wuhan University, Wuhan 430072, China 《Wuhan University Journal of Natural Sciences》 EI CAS 2000年第4期479-484,共6页
The stability constants and thermodynamic functions for complexes of lanthanum with eight kind of amino acids according to 1∶1 and 1∶2 in proportion have been determined by titration calorimeter at 298.15 K. The ent... The stability constants and thermodynamic functions for complexes of lanthanum with eight kind of amino acids according to 1∶1 and 1∶2 in proportion have been determined by titration calorimeter at 298.15 K. The enthalpy change makes a predominant contribution to the stability of these complexes. The ring in amino acid associated with lanthanum ion helps to enhance the stability of complexes. Steric effects between rings in complexes leads to that the equilibrium constants of reaction of the complexes (1∶2) is much less than that of the complexes (1∶1). 展开更多
关键词 titration calorimeter rare earth amino acid COMPLEXES steric effects
下载PDF
Energy calibration of laterally segmented electromagnetic calorimeters based on neutral pion detection 被引量:1
4
作者 Malek Mazouz 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第11期164-171,共8页
This paper describes a method for energy calibration of laterally segmented electromagnetic calorimeters based on the detection of two-photon decays of π~0 mesons.The calibration procedure performs a X^2 function min... This paper describes a method for energy calibration of laterally segmented electromagnetic calorimeters based on the detection of two-photon decays of π~0 mesons.The calibration procedure performs a X^2 function minimization between the measured π~0 energy in the calorimeter and its expected energy deduced from the π~0 momentum direction. The performance of this technique is demonstrated with a Monte Carlo simulation of an experimental case where biased calibration coefficients are employed. The real calibration coefficients are restored with less than 1% relative accuracy when a sufficient number of π~0 is detected. This technique is applied to monitor daily the calibration coefficients of the calorimeter used in the Jefferson Lab Hall A DVCS experiments. 展开更多
关键词 ELECTROMAGNETIC calorimeterS Energy CALIBRATION DETECTOR modeling and simulations Data processing methods
下载PDF
Adiabatic Decomposition of Two Kinds of Organic Peroxides by Accelerating Rate Calorimeter 被引量:1
5
作者 钱新明 刘萍 刘丽 《Journal of Beijing Institute of Technology》 EI CAS 2004年第S1期41-44,共4页
The accelerating rate calorimeter was applied to study the thermal hazard of two kinds of organic peroxides, i.e. methyl ethyl ketone peroxide (MEKPO) and benzoyl peroxide (BPO). And their thermal decomposition charac... The accelerating rate calorimeter was applied to study the thermal hazard of two kinds of organic peroxides, i.e. methyl ethyl ketone peroxide (MEKPO) and benzoyl peroxide (BPO). And their thermal decomposition characteristics were discussed. Meanwhile, thermal decomposition characteristics of MEKPO and BPO vvere compared. The result indicated that MEKPO is more sensitive to thermal effect than BPO. While once the thermal decomposition takes place. BPO will be more hazardous than MEKPO due to its serious pressure effect. Thermal kinetic analysis of these two kinds of organic peroxides was also taken, and the kinetic parameters for them were calculated. The study of thermal decomposition of MEKPO solution with different initial concentrations indicated that, the lower concentration MEKPO solution is, the higher onset temperature will be. And with the addition of organic solvent, it becomes more difficult for MEKPO to reach a thermal decomposition. Therefore, its thermal hazard is reduced. 展开更多
关键词 organic peroxide: thermal stability: chemical reaction kinetics accelerating rate calorimeter
下载PDF
Theoretical and experimental assessment of a novel method to establish the complete measurement range of the calorimeter and its limit of detection and quantification
6
作者 Vesna Krstic 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第4期466-473,共8页
For determining the accuracy of a calorimeter over the instrument’s entire measuring range,a novel method has been established.For this new approach,(a)benzoic acid(C_(6)H_(5)CO_(2)H) as a certified reference materia... For determining the accuracy of a calorimeter over the instrument’s entire measuring range,a novel method has been established.For this new approach,(a)benzoic acid(C_(6)H_(5)CO_(2)H) as a certified reference material(CRM),(b)SiO_(2) and(c)a mixture of CRM benzoic acid and SiO_(2) have been used.To illustrate the essential difference between 1)the novel analytical method for control of the entire measurement range and 2)the calorimeter calibration,both applications of benzoic acid(BA)have been demonstrated.An experimental result showed that BA was successfully used to check the whole calorimeter measurement range.The results also showed that the same new method was successfully applied to determine the limit of detection and quantification.A new instrument testing process and a new measurement technique have thus been established.In this way,the cost of using CRM to control the accuracy of measuring the entire measuring range of the calorimeter,as shown in this paper,is minimized.The requirements of the ISO/IEC 17025:2017 standard are satisfied.ISO/IEC 17025:2017,together with ISO 9001:2015(quality management systems),ISO 14001:2015(relate to environmental protection)and ISO45001:2018(occupational safety),constitute an integrated quality system by which a testing laboratory may also accredit. 展开更多
关键词 Benzoic acid Certified reference material The limit of detection/quantification Measurement range Quality control calorimeter Environmental protection
下载PDF
Study of Burning Behaviors and Fire Risk of Flame Retardant Plywood by Cone Calorimeter and TG Test
7
作者 Liping Yu Zhongyou Luo +3 位作者 Lifen Li Xuedong Xi Zhigang Wu Bengang Zhang 《Journal of Renewable Materials》 SCIE EI 2021年第12期2143-2157,共15页
A flame retardant composition was prepared by using phosphoguanidine,guanidine sulfamate,disodium octaborate tetrahydrate and dodecyl dimethyl benzyl ammonium chloride.Veneers were immersed in such flame retardant mix... A flame retardant composition was prepared by using phosphoguanidine,guanidine sulfamate,disodium octaborate tetrahydrate and dodecyl dimethyl benzyl ammonium chloride.Veneers were immersed in such flame retardant mixture to prepare plywood.The combustion characteristics and thermal stability of plywood were assessed using a cone calorimeter and TG.Results showed that:(1)High concentration and loading of flame retardant were beneficial for the fire resistance of the plywood.(2)The limiting oxygen index(LOI)and residual mass of plywood processed using the flame retardant was increased by 87.52%and 58.66%compared to those of the untreated plywood,while the average heat release rate(av-HRR),total heat release(THR),effective heat of combustion(EHC),total smoke release(TSR),CO yield(COY),CO_(2) yield(CO_(2)Y)and oxygen consumption were decreased by 44.3%,82.9%,47.0%,86.0%,89.9%,50.1%and 83.1%,respectively.(3)Treated plywood which had a low fire growth index(FGI)displayed a later combustion heat release rate peak and slower flame spread than observed for the untreated material.Combustion of treated plywood displayed a higher fire performance index(FPI),indicating a longer time to ignition.This suggests that burning structures from this material would be subject to a longer time for escape from the structure and would present lower fire risk than similar structures containing treated plywood.(4)TG results demonstrated that the presence of the flame retardant can decrease the pyrolysis temperature for hemicellulose and cellulose,change the decomposition and reaction progress for plywood degradation and promote dehydration carbonization and accelerated charformation.Moreover,the formed char was more stable than that combustion of untreated plywood.(5)The flame retardant contains nitrogen(N),phosphorus(P),boron(B),chlorine(Cl)and guanidine(Gu)compounds.The adhesive also contains N and P compounds.These substances display flame resistance and supplement each other to generate flame retardance than any one used alone.By changing the thermolysis and thermal decomposition processes,the heat release and smoke release from plywood,undergoing combustion was reduced.This controlled generation of combustible substances and promoted dehydration and carbonization to form char.As a result,the flame resistance of plywood was improved significantly.The probability of smoke asphyxia or poisoning death of those trapped in structures containing treated plywood during fire accidents can be decreased dramatically. 展开更多
关键词 Flame retardant PLYWOOD cone calorimeter burning behaviors fire risk
下载PDF
Heat of Boron Trifluoride–Methanol System Determined by Bunsen Ice Calorimeter
8
作者 Weijiang Zhang Yace Zhang +1 位作者 Yuvaraja Gutha Jiao Xu 《Transactions of Tianjin University》 EI CAS 2018年第4期370-374,共5页
The complex heat of BF_3 with methanol was measured by utilizing the principle of the Bunsen ice calorimeter. The complex heat of BF_3 –methanol was found to be 49.2 and 58.1 kJ/mol when the molar ratio of BF_3 to me... The complex heat of BF_3 with methanol was measured by utilizing the principle of the Bunsen ice calorimeter. The complex heat of BF_3 –methanol was found to be 49.2 and 58.1 kJ/mol when the molar ratio of BF_3 to methanol was 1:2 and 1:1,respectively. In addition,the complex heat of BF_3 –anisole was also measured to test the apparatus error. The BF_3 –anisole result showed a calorimeter value of 53.1 kJ/mol with a system error of 2.3% as compared with the value reported in the literature. The mechanism of the reaction of BF_3 and methanol was interpreted based on our obtained results. This apparatus is useful and suitable for measuring the heat of other liquid–gas and liquid–liquid reactions. 展开更多
关键词 HEAT of reaction BF 3–methanol BF 3–anisole Bunsen ICE calorimeter Gas–liquid SYSTEM measurement apparatus
下载PDF
Comparison of Proton Shower Developments in the BGO Calorimeter of the Dark Matter Particle Explorer between GEANT4 and FLUKA Simulations
9
作者 蒋维 岳川 +30 位作者 崔明阳 李翔 袁强 Francesca Alemanno Paolo Bernardini Giovanni Catanzani 陈占方 Ivan De Mitri 董铁矿 Giacinto Donvito David Francois Droz Piergiorgio Fusco Fabio Gargano 郭东亚 Dimitrios Kyratzis 雷仕俊 刘杨 Francesco Loparco 马鹏雄 Giovanni Marsella Mario Nicola Mazziotta 潘旭 彭文溪 Antonio Surdo Andrii Tykhonov 魏逸丰 余玉洪 藏京京 张亚鹏 张永杰 张云龙 《Chinese Physics Letters》 SCIE CAS CSCD 2020年第11期114-120,共7页
The DArk Matter Particle Explorer(DAMPE)is a satellite-borne detector for high-energy cosmic rays and y-rays.To fully understand the detector performance and obtain reliable physical results,extensive simulations of t... The DArk Matter Particle Explorer(DAMPE)is a satellite-borne detector for high-energy cosmic rays and y-rays.To fully understand the detector performance and obtain reliable physical results,extensive simulations of the detector are necessary.The simulations are particularly important for the data analysis of cosmic ray nuclei,which relies closely on the hadronic and nuclear interactions of particles in the detector material.Widely adopted simulation softwares include the GEANT4 and FLUKA,both of which have been implemented for the DAMPE simulation tool.Here we describe the simulation tool of DAMPE and compare the results of proton shower properties in the calorimeter from the two simulation softwares.Such a comparison gives an estimate of the most significant uncertainties of our proton spectral analysis. 展开更多
关键词 material. GEANT4 calorimeter
下载PDF
Proposed Cone Calorimeter for Woven Carpet
10
作者 Sanaa M. Enany 《Journal of Textile Science and Technology》 2019年第3期61-68,共8页
It is necessary to achieve the best specifications in carpets that provide safety to human health in establishments and buildings. This can be achieved by reducing the emissions of toxic gases from combustion via cont... It is necessary to achieve the best specifications in carpets that provide safety to human health in establishments and buildings. This can be achieved by reducing the emissions of toxic gases from combustion via controlling the carpets composition. This research presents a study on carpets behavior when burning samples with different mixing specifications to determine the combustion products by conducting a test using cone Calorimeter to determine the effect of different structures of the carpet on combustion products. The study includes the effect of both the quality of the material used and their different densities and thicknesses. The research provides an analysis of carpet combustion products from different emissions, such as the amount of carbon monoxide CO, the amount of carbon dioxide CO2, smoke density, heat of combustion, and the heat released rate. It is clear that the rate of heat released is uneven in samples with different percentages of mixing. The samples with higher mixing percentage of synthetic fibers give lower temperature while the samples with higher wool percentage give higher temperature. The temperature of combustion increases gradually with the increase of the percentage of wool while the density of the smoke decreases which achieves the required safety of carpets. In addition to this, the research proves the increase of both CO and CO2 as the percentage of synthetic fibers in products which confirms the necessity to avoid the adverse effects of these emissions on human health. 展开更多
关键词 CARPETS CONE calorimeter COMBUSTION Products EMISSIONS
下载PDF
Refractory Materials-Determination of Thermal Conductivity(Calorimeter)YB/T 4130-2005
11
作者 Zhang Xiaohui Wang Jing Yu Lingyan 《China's Refractories》 CAS 2013年第1期38-40,共3页
1 Scope This standard specifies the definition, theory, equipment, samples, test procedures, test error, etc. of test method (calorimeter) for thermal conductivity of refractories.
关键词 Refractory Materials-Determination of Thermal Conductivity calorimeter)YB/T 4130-2005
下载PDF
Geant4 application for efficiency simulation of PbF2 based calorimeters
12
作者 A.A.Savchenko A.A.Tishchenko 《Radiation Detection Technology and Methods》 CSCD 2023年第3期435-446,共12页
Purpose This study aims to create a new tool for fast computer simulations allowing one to design advanced electromagnetic calorimeters with the required properties.The application must calculate the calorimeter effic... Purpose This study aims to create a new tool for fast computer simulations allowing one to design advanced electromagnetic calorimeters with the required properties.The application must calculate the calorimeter efficiency and measure the particles'energies,momenta and interaction time to detect the particles.This application should become the basis for a new technology of positron emission tomography.Methods To solve the problem,a new C++application based on Geant4 simulation toolkit has been developed.To monitor the response of calorimeters to different types of primary particles,we used different auxiliary Geant4 classes.In addition,we compare the simulation results for the detectors of three different setups,taking into account the detection of both electrons and gamma-quanta,and analyze their efficiency.To evaluate the capability of calorimeters to work under radiation load,we use an experimentally measured transmission function of radiation-damaged PbF_(2).Results Three calorimeter setups exploiting PbF_(2)were simulated with a new C++application based on Geant4.We showed that such type of calorimeter has an energy resolution of 4.1%√E^(e+)[GeV]and good linearity of response for GeV positrons measurements.The efficiency of such structures is found to be approximately 20%for gamma photons’detection.The multilayered structure based on gamma-quanta detection has been proven to be more efficient.It was shown that for the total ionizing dose of 30 krad the Cherenkov light yield decreases by up to two times for 14 cm long PbF_(2)crystals,while for the shorter ones(2.5 and 1.5 cm)this effect is almost negligible.Conclusions We present a new user application in Geant4 for fast simulation of complex structures designed for detection of different high-energy neutral and charged particles.Simulation of calorimeter interaction with 10^(3) of 3 GeV positrons takes 20 min on usual laptop,while for 105511 keV gamma photons it takes 1 min on average.This application allows one to evaluate the efficiency of electromagnetic calorimeters exploiting lead fluoride crystals.Our results pave the way for advanced particle energy measurements,including those used in rapidly developing medical applications such as positron emission tomography,single-photon emission computed tomography etc. 展开更多
关键词 GEANT4 Cherenkov radiation Positron emission tomography Electromagnetic calorimeter PbF_(2)
原文传递
Equalization for the low-response cells of the AMS-02 electromagnetic calorimeter
13
作者 Jia-Yu Hu Ze-Tong Sun +9 位作者 Zu-Hao Li Zhi-Cheng Tang Cheng Zhang Feng-Ze Zhang Shang-Lin Li Mei-Jun Liang Hao-Tian Yang Yu-Hang You Meng Wang He-Sheng Chen 《Radiation Detection Technology and Methods》 CSCD 2023年第3期350-354,共5页
Purpose Performing precision equalization on the low-response detection units of electromagnetic calorimeter(ECAL),it is essential for precision energy measurements of Alpha Magnetic Spectrometer(AMS-02).Methods Cosmi... Purpose Performing precision equalization on the low-response detection units of electromagnetic calorimeter(ECAL),it is essential for precision energy measurements of Alpha Magnetic Spectrometer(AMS-02).Methods Cosmic helium nuclei are used instead of protons to perform the equalization.During the equalization,temperature effects are analyzed and corrected to improve the accuracy.Results The results of helium equalization are consistent with proton equalization,and the precision of helium equalization is about 1.5%.Conclusions The precision of helium equalization is better than that of proton equalization,which provides a reliable alternative to ECAL on-orbit equalization. 展开更多
关键词 Electromagnetic calorimeter EQUALIZATION Helium MIP Temperature effect
原文传递
A high dynamic range readout unit for a calorimeter 被引量:3
14
作者 张云龙 李冰 +8 位作者 封常青 蔡先利 汪晓莲 许咨宗 郭建华 蔡明生 胡一鸣 伍健 常进 《Chinese Physics C》 SCIE CAS CSCD 2012年第1期71-73,共3页
A high dynamic range readout system,consisting of a multi-dynode readout PMT and a VA32 chip,is presented.An LED system is set up to calibrate the relative gains between the dynodes,and the ADC counts per MIPs from dy... A high dynamic range readout system,consisting of a multi-dynode readout PMT and a VA32 chip,is presented.An LED system is set up to calibrate the relative gains between the dynodes,and the ADC counts per MIPs from dynode 7 are determined under cosmic-ray calibration.A dynamic range from 0.5 MIPs to 1×10 5 MIPs is achieved. 展开更多
关键词 BGO calorimeter VA32 chip PMT LED high dynamic readout
原文传递
Study of backward terahertz radiation from intense picosecond laser–solid interactions using a multichannel calorimeter system 被引量:2
15
作者 H. Liu G.-Q. Liao +12 位作者 Y.-H. Zhang B.-J. Zhu Z. Zhang Y.-T. Li G. G. Scott D. Rusby C. Armstrong E. Zemaityte P. Bradford N. Woolsey P. Huggard P. McKenna D. Neely 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2019年第1期47-53,共7页
A multichannel calorimeter system is designed and constructed which is capable of delivering single-shot and broadband spectral measurement of terahertz(THz) radiation generated in intense laser–plasma interactions. ... A multichannel calorimeter system is designed and constructed which is capable of delivering single-shot and broadband spectral measurement of terahertz(THz) radiation generated in intense laser–plasma interactions. The generation mechanism of backward THz radiation(BTR) is studied by using the multichannel calorimeter system in an intense picosecond laser–solid interaction experiment. The dependence of the BTR energy and spectrum on laser energy, target thickness and pre-plasma scale length is obtained. These results indicate that coherent transition radiation is responsible for the low-frequency component(<1 THz) of BTR. It is also observed that a large-scale pre-plasma primarily enhances the high-frequency component(>3 THz) of BTR. 展开更多
关键词 MULTICHANNEL calorimeter BACKWARD TERAHERTZ radiation generation MECHANISMS
原文传递
The flame retardancy of alginate/flame retardant viscose fibers investigated by vertical burning test and cone calorimeter 被引量:6
16
作者 Xian-Sheng Zhang Yan-Zhi Xia +1 位作者 Mei-Wu Shi Xiong Yan 《Chinese Chemical Letters》 SCIE CAS CSCD 2018年第3期489-492,共4页
In this research, the flame retardancy of neat alginate fiber, flame retardant viscose fiber (FRV) and alginate/FRV (50/50) blending fibers were investigated by vertical burning and cone calorimeter tests. The ver... In this research, the flame retardancy of neat alginate fiber, flame retardant viscose fiber (FRV) and alginate/FRV (50/50) blending fibers were investigated by vertical burning and cone calorimeter tests. The vertical burning test showed that the afterflame time of alginate fiber was 0 s, but alginate presented serious smoldering behavior with the afterglow time of 605 s and damaged length of 85 mm, while the afterglow time of FRV was 0 s. When the FRV was incorporated into alginate with the weight ratio of 50/ 50, the afterglow time and damaged length were significantly reduced to 85 s and 35 mm, indicating the smoldering of alginate can be effectively decreased. The morphology and chemical structure of the alginate residual demonstrated that it was seriously destroyed during smoldering process, which was ascribed to its relative low initial thermal degradation temperature. Based on the thermal properties analysis, alginate and FRV fibers shared the concurrence of rapid degradation in the same temperature region of 250-300 ℃, through which, the compact and stable char formed by FRV can prevent the heat transmission and suppress the smoldering of alginate. Further, the cone calorimeter results demonstrated that the time to ignition (TTI) significantly increased and peak heat release rate (PHRR) decreased for alginate/FRV (50/50) compared with FRV. With this research, a new method to overcome the smoldering of alginate was proposed by blending with FRV 展开更多
关键词 Alginate fibers Flame retardant viscose fibers Blending Flame retardancy Vertical burning test Cone calorimeter
原文传递
Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter 被引量:1
17
作者 李祖豪 王玲玉 +3 位作者 许伟伟 陈国明 吕雨生 陈和生 《Chinese Physics C》 SCIE CAS CSCD 2013年第2期64-67,共4页
The position effect of the photoelectron multiplier tube (PMT) of the electromagnetic calorimeter (ECAL) of Alpha Magnetic Spectrometer-02 (AMS-02) has been studied with beam-test data. The reconstructed deposit... The position effect of the photoelectron multiplier tube (PMT) of the electromagnetic calorimeter (ECAL) of Alpha Magnetic Spectrometer-02 (AMS-02) has been studied with beam-test data. The reconstructed deposited energy in a layer versus incidence position in the cell can be described by Gaussian distribution, maximum and minimum value can be obtained when the particle passes across the center and the edge of a cell respectively. The distribution can be used to correct the effect of incidence position on energy reconstruction. Much better energy resolution was acquired be got with the correction, for 100 GeV electrons, energy resolution improved from 3% to 2%. 展开更多
关键词 electromagnetic calorimeter photo multiplier tube position effect energy resolution
原文传递
Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter 被引量:1
18
作者 李祖豪 许伟伟 +7 位作者 王玲玉 张诚 唐志成 严琪 杨民 吕雨生 陈国明 陈和生 《Chinese Physics C》 SCIE CAS CSCD 2014年第5期76-81,共6页
The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was... The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters. 展开更多
关键词 electromagnetic calorimeter angular resolution lateral fit Neighbor Cell Deposited Energy Ratio
原文传递
Monte Carlo study on the low momentum μ-π identification of the BESⅢ EM calorimeter 被引量:1
19
作者 王志刚 吕军光 +15 位作者 何康林 安正华 蔡啸 董明义 方建 胡涛 刘万金 吕绮雯 宁飞鹏 孙丽君 孙希磊 王晓东 薛镇 俞伯祥 章爱武 周莉 《Chinese Physics C》 SCIE CAS CSCD 2009年第10期880-886,共7页
Abstract The BESⅢ detector has a high-resolution electromagnetic calorimeter which can be used for low momentum μ-π identification. Based on Monte Carlo simulations, μ-π separation was studied. A multilayer perce... Abstract The BESⅢ detector has a high-resolution electromagnetic calorimeter which can be used for low momentum μ-π identification. Based on Monte Carlo simulations, μ-π separation was studied. A multilayer perceptron neural network making use of the defined variables was used to do the identification and a good μ-π separation result was obtained. 展开更多
关键词 BESⅢ calorimeter particle identification artificial neural network
原文传递
Design and assembly of the CsI(Tl) crystal module of the BESⅢ electro-magnetic calorimeter 被引量:1
20
作者 董明义 蔡啸 +11 位作者 方建 胡涛 赖元芬 刘春秀 吕军光 刘万金 尚雷 孙丽君 王志刚 夏小米 俞伯祥 周莉 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第11期908-911,共4页
The CsI(T1) crystal modules of the Beijing Spectrometer Ⅲ (BESⅢ) electro-magnetic calorimeter (EMC) were designed and assembled through Monte Carlo simulation and experiments. After the assembly was finished, ... The CsI(T1) crystal modules of the Beijing Spectrometer Ⅲ (BESⅢ) electro-magnetic calorimeter (EMC) were designed and assembled through Monte Carlo simulation and experiments. After the assembly was finished, the performance of each crystal module was tested by cosmic rays. All crystal modules were found to work well before the installation of EMC. 展开更多
关键词 BESⅢ electro-magnetic calorimeter CsI(T1) crystal crystal module