Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze it...Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze its clinical significance. Methods: Seven patients with lumbar joint dysfunction and 8 healthy subjects were tested twice by the CCD-based system with an interval of 10 min. Results: The ROM of the patients was obviously lesser than that of the healthy subjects. The measuring data of segmental ROM of lumbar spine by CCD system is correlated significantly to the same data checked later on the same subjects in every direction of the movements. The differences between two checks are usually less than 1 degree. Conclusion: Specially designed CCD based system for 3-dimensional real-time positioning could objectively reflect the segmental ROM of lumbar spine. The system would be of great clinical significance in the assessment of the biomechanical dysfunction of lumbar spine and the effect of the treatment applied.展开更多
The proposed multi-dimensional quantitative fluorescence microscopy for the CASLIBB single-particle microbeam II endstation is a CCD-based imaging system. We systematically analyse the theoretical and the practical co...The proposed multi-dimensional quantitative fluorescence microscopy for the CASLIBB single-particle microbeam II endstation is a CCD-based imaging system. We systematically analyse the theoretical and the practical considerations pertinent to choosing the right CCD camera and unveiling the principles underlying multifarious parameters. Therefore, this analysis can be a valuable tool in scrutinizing each parameter and clarifying proper usage of a scientific CCD camera.展开更多
Radiative imaging of combustion flame in furnace of power plant plays an increasingly important role in combustion diagnosis. This paper presents a new method for calculating the radiative imaging of three-dimensional...Radiative imaging of combustion flame in furnace of power plant plays an increasingly important role in combustion diagnosis. This paper presents a new method for calculating the radiative imaging of three-dimensional (3D) combustion flame based on Monte Carlo method and optical lens imaging. Numerical simulation case was used in this study. Radiative images were calculated and images obtained can not only present the energy distribution on the charge-coupled device (CCD) camera target plane but also reflect the energy distribution condition in the simulation furnace. Finally the relationships between volume ele- ments and energy shares were also discussed.展开更多
Morphological parameters of coarse aggregates,including the angularity index (Al),flat and elongated ratio,flatness ratio,and sphericity,strongly affect the performance of asphalt concrete.A device must be developed t...Morphological parameters of coarse aggregates,including the angularity index (Al),flat and elongated ratio,flatness ratio,and sphericity,strongly affect the performance of asphalt concrete.A device must be developed to efficiently and accurately measure these parameters.Herein,a charge-coupled device camera and a linear profile scanner are combined to evaluate the parameters.The Al is calculated using three methods.The results show that the fitted-ellipse method provides superior results among the three Al measurement methods.Moreover,the use of a linear profile scanner improves the Al measurement accuracy.Therefore,the proposed combination has high measurement efficiency and is suitable for batch inspections.展开更多
This paper applies digital image techniques to observe the slagging characteristics of blended coals in a pilot-scale furnace. Collected deposit samples were analyzed by scanning electron microscopy linked with energy...This paper applies digital image techniques to observe the slagging characteristics of blended coals in a pilot-scale furnace. Collected deposit samples were analyzed by scanning electron microscopy linked with energy-dispersive X-ray analysis (SEM-EDX), X-ray diffraction (XRD), and X-ray Fluorescence (XRF) to acquire the microstructure, chemical composition, and mineralogy. The deposit thickness of three blends was analyzed between their parent coal A (Datong) and coal B (Shan), and we noted that the time to reach a stable stage decreased with the ratio of coal B. The addition of coal A into coal B could remarkably restrained the growth and thickness of ash deposits. The results of XRD analysis indicated the initial layer was predominantly comprised of the crystalline minerals quartz, anorthite, or albite except for coal B. All of the blends and coals contained quartz and Ca- to Al-silicates (Ca0.68Na0.32)(All.68Si0.32)Si2O8 in the slag layer where iron-bearing minerals (e.g., ilvaite) were altered into an amorphous phase. The result of SEM-EDX suggested that there was an elemental disparity between the coal ash and deposit.展开更多
文摘Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze its clinical significance. Methods: Seven patients with lumbar joint dysfunction and 8 healthy subjects were tested twice by the CCD-based system with an interval of 10 min. Results: The ROM of the patients was obviously lesser than that of the healthy subjects. The measuring data of segmental ROM of lumbar spine by CCD system is correlated significantly to the same data checked later on the same subjects in every direction of the movements. The differences between two checks are usually less than 1 degree. Conclusion: Specially designed CCD based system for 3-dimensional real-time positioning could objectively reflect the segmental ROM of lumbar spine. The system would be of great clinical significance in the assessment of the biomechanical dysfunction of lumbar spine and the effect of the treatment applied.
基金supported by the the National Major Technologies R&D Programme of China during the 10th Five-Year Plan Period(No.2001BA302B)the National Science Foundation for Distinguished Young Scholars(No.10225526)+1 种基金the Knowledge Innovation Programme of the Chinese Academy of Sciences(No.KSCX2-SW-324)the Foundation for University Key Teacher by the Ministry of Education(No.2005jq1135).
文摘The proposed multi-dimensional quantitative fluorescence microscopy for the CASLIBB single-particle microbeam II endstation is a CCD-based imaging system. We systematically analyse the theoretical and the practical considerations pertinent to choosing the right CCD camera and unveiling the principles underlying multifarious parameters. Therefore, this analysis can be a valuable tool in scrutinizing each parameter and clarifying proper usage of a scientific CCD camera.
基金Project supported by National Natural Science Foundation of China(No. 60534030)Program for Changjiang Scholars and InnovativeResearch Team in University (No. IRT0434)
文摘Radiative imaging of combustion flame in furnace of power plant plays an increasingly important role in combustion diagnosis. This paper presents a new method for calculating the radiative imaging of three-dimensional (3D) combustion flame based on Monte Carlo method and optical lens imaging. Numerical simulation case was used in this study. Radiative images were calculated and images obtained can not only present the energy distribution on the charge-coupled device (CCD) camera target plane but also reflect the energy distribution condition in the simulation furnace. Finally the relationships between volume ele- ments and energy shares were also discussed.
文摘Morphological parameters of coarse aggregates,including the angularity index (Al),flat and elongated ratio,flatness ratio,and sphericity,strongly affect the performance of asphalt concrete.A device must be developed to efficiently and accurately measure these parameters.Herein,a charge-coupled device camera and a linear profile scanner are combined to evaluate the parameters.The Al is calculated using three methods.The results show that the fitted-ellipse method provides superior results among the three Al measurement methods.Moreover,the use of a linear profile scanner improves the Al measurement accuracy.Therefore,the proposed combination has high measurement efficiency and is suitable for batch inspections.
基金the National Natural Science Foundation of China
文摘This paper applies digital image techniques to observe the slagging characteristics of blended coals in a pilot-scale furnace. Collected deposit samples were analyzed by scanning electron microscopy linked with energy-dispersive X-ray analysis (SEM-EDX), X-ray diffraction (XRD), and X-ray Fluorescence (XRF) to acquire the microstructure, chemical composition, and mineralogy. The deposit thickness of three blends was analyzed between their parent coal A (Datong) and coal B (Shan), and we noted that the time to reach a stable stage decreased with the ratio of coal B. The addition of coal A into coal B could remarkably restrained the growth and thickness of ash deposits. The results of XRD analysis indicated the initial layer was predominantly comprised of the crystalline minerals quartz, anorthite, or albite except for coal B. All of the blends and coals contained quartz and Ca- to Al-silicates (Ca0.68Na0.32)(All.68Si0.32)Si2O8 in the slag layer where iron-bearing minerals (e.g., ilvaite) were altered into an amorphous phase. The result of SEM-EDX suggested that there was an elemental disparity between the coal ash and deposit.