The major phytoplankton was investigated and analyzed in landscape water of six campuses in Nanjing Xianlin University Town,and water quality was evaluated by single factor assessment method and comprehensive weighted...The major phytoplankton was investigated and analyzed in landscape water of six campuses in Nanjing Xianlin University Town,and water quality was evaluated by single factor assessment method and comprehensive weighted evaluation method.The result showed that the major phytoplankton groups were Cyanophyta,Chlorophyta and Bacillariophyta.Besides,each evaluation indicator showed that waterbodies in four campuses were eutrophicated and result of single factor evaluation showed water quality all belonged to poor category V.The result of comprehensive weighted assessment showed that waters in Nanjing Normal University and Nanjing University of Posts and Telecommunications were seriously polluted,cyanobacterial bloom appearing.Waters in Nanjing University of Chinese Medicine and Nanjing Forest Police College hadn't been eutrophicated.展开更多
The pollution situation of different underlying surface and the change rule of each water quality index were researched,on the basis of rainwater quality monitoring by different approaches in a university campus. The ...The pollution situation of different underlying surface and the change rule of each water quality index were researched,on the basis of rainwater quality monitoring by different approaches in a university campus. The results showed that due to some factors,such as the underlying surface material pollution,road materials,road surface pollution condition and surrounding atmospheric environment quality,the pollution of different underlying surface rainwater would be different. Main pollutants of rainwater runoff in the city campus area were such as COD,SS,NH;-N,TP,etc. Ultimately,along with the increase of accumulated rainfall,the pollutants tended to gradually decrease. The road rain pollution was more serious than roof runoff pollution and the early rain pollution was serious,but the late rain water quality was much better. According to the rainwater conditions,subsequent rainwater recycling technology and processing technology were determined as a way to alleviate the problem of water shortage and water pollution.展开更多
Sound pond productivity accompanied with adequate fish health is maintained, when water quality parameters are conducive. The study evaluated the chemical composition of a pond feed from spring water, in Asaba Campus....Sound pond productivity accompanied with adequate fish health is maintained, when water quality parameters are conducive. The study evaluated the chemical composition of a pond feed from spring water, in Asaba Campus. Sampling was carried out from September 2011 to February 2012 on a monthly basis. Surface water samples were collected between the hours of 7:00-9:00 am from the pond on each sampling day. Hydrogen-ion-concentration was in the range of 6.5 to 8.0 units. Dissolved oxygen was the highest in February 2012 with a value of 11.0 mg/L while it was the lowest in December 2011 with a value of 9.0 mg/L. Biological oxygen demand ranged from 3.5 to 5.0 mg/L. The chemical oxygen demand was the highest in December (10.00 mg/L) and lowest between January and February (8.0mg/L). The highest alkalinity was observed in October with a value of 1.05 mg/L and lowest in December with a value of 0.042 mg/L. Conductivity values ranged from 0.075 to 0.12 μS/cm. Total phosphorus was the highest in October with a value of 1.01 mg/L and lowest in December with a value of 0.83 mg/L. Total dissolved solids ranged from 90 to 105 mg/L. Values of physco-chemical parameters revealed that the pond was not polluted. Water quality analysis of the aquatics is of economic advantage to the fish farmer, hence, the need for its assessment at regular intervals. This is a quality assurance process that assures early dictation of toxic substances and mitigation processes to adopt before problems arise. In this way, the good health of organisms in the aquatic ecosystem and those of human dependent on them are guaranteed.展开更多
This paper uses scenery complementary heating method to discuss a new type of scenery complementary water heater design. This product can be divided into two parts. The first part is the eddy current method wind power...This paper uses scenery complementary heating method to discuss a new type of scenery complementary water heater design. This product can be divided into two parts. The first part is the eddy current method wind power heating part, which is driven by wind power and vertical axis wind turbines and the design of magnet array rotor disc rotation, namely, magnetic field rotating, induced eddy current in the stator, so as to generate heat. The second part is the solar heating part. This works has broad market prospect, which provides a new idea for large-scaled heating method.展开更多
Based on the renovation of sponge and energy-saving facilities in a middle school in Nanning,this paper systematically studies the overall elevation of the campus,the composition of the drainage system and the layout ...Based on the renovation of sponge and energy-saving facilities in a middle school in Nanning,this paper systematically studies the overall elevation of the campus,the composition of the drainage system and the layout of space functions,and formulates a characteristic scheme for the renovation of sponge and energy-saving facilities according to the characteristics of the sloping campus.In order to control the total amount of rainwater runoff,the sponge transformation mainly adopts the transformation methods of partition catchment,upper storage and lower use,multi-stage detection and classification treatment.For the purpose of solar energy and wind energy utilization,solar photovoltaic panels and small-scale wind power generation system are adopted.The application effects of sponge and energy-saving facilities are estimated and evaluated.展开更多
基金Supported by National Foundation for Fostering Talents in Basic Science(J0730650)~~
文摘The major phytoplankton was investigated and analyzed in landscape water of six campuses in Nanjing Xianlin University Town,and water quality was evaluated by single factor assessment method and comprehensive weighted evaluation method.The result showed that the major phytoplankton groups were Cyanophyta,Chlorophyta and Bacillariophyta.Besides,each evaluation indicator showed that waterbodies in four campuses were eutrophicated and result of single factor evaluation showed water quality all belonged to poor category V.The result of comprehensive weighted assessment showed that waters in Nanjing Normal University and Nanjing University of Posts and Telecommunications were seriously polluted,cyanobacterial bloom appearing.Waters in Nanjing University of Chinese Medicine and Nanjing Forest Police College hadn't been eutrophicated.
基金Supported by the"13th Five-year"Science and Technology Research Item of Jilin Education Department(Jijiaokehezi[2016]531)Student's Platform for Innovation and Entrepreneurship Training Program in Jilin Province in 2017(3430)
文摘The pollution situation of different underlying surface and the change rule of each water quality index were researched,on the basis of rainwater quality monitoring by different approaches in a university campus. The results showed that due to some factors,such as the underlying surface material pollution,road materials,road surface pollution condition and surrounding atmospheric environment quality,the pollution of different underlying surface rainwater would be different. Main pollutants of rainwater runoff in the city campus area were such as COD,SS,NH;-N,TP,etc. Ultimately,along with the increase of accumulated rainfall,the pollutants tended to gradually decrease. The road rain pollution was more serious than roof runoff pollution and the early rain pollution was serious,but the late rain water quality was much better. According to the rainwater conditions,subsequent rainwater recycling technology and processing technology were determined as a way to alleviate the problem of water shortage and water pollution.
文摘Sound pond productivity accompanied with adequate fish health is maintained, when water quality parameters are conducive. The study evaluated the chemical composition of a pond feed from spring water, in Asaba Campus. Sampling was carried out from September 2011 to February 2012 on a monthly basis. Surface water samples were collected between the hours of 7:00-9:00 am from the pond on each sampling day. Hydrogen-ion-concentration was in the range of 6.5 to 8.0 units. Dissolved oxygen was the highest in February 2012 with a value of 11.0 mg/L while it was the lowest in December 2011 with a value of 9.0 mg/L. Biological oxygen demand ranged from 3.5 to 5.0 mg/L. The chemical oxygen demand was the highest in December (10.00 mg/L) and lowest between January and February (8.0mg/L). The highest alkalinity was observed in October with a value of 1.05 mg/L and lowest in December with a value of 0.042 mg/L. Conductivity values ranged from 0.075 to 0.12 μS/cm. Total phosphorus was the highest in October with a value of 1.01 mg/L and lowest in December with a value of 0.83 mg/L. Total dissolved solids ranged from 90 to 105 mg/L. Values of physco-chemical parameters revealed that the pond was not polluted. Water quality analysis of the aquatics is of economic advantage to the fish farmer, hence, the need for its assessment at regular intervals. This is a quality assurance process that assures early dictation of toxic substances and mitigation processes to adopt before problems arise. In this way, the good health of organisms in the aquatic ecosystem and those of human dependent on them are guaranteed.
文摘This paper uses scenery complementary heating method to discuss a new type of scenery complementary water heater design. This product can be divided into two parts. The first part is the eddy current method wind power heating part, which is driven by wind power and vertical axis wind turbines and the design of magnet array rotor disc rotation, namely, magnetic field rotating, induced eddy current in the stator, so as to generate heat. The second part is the solar heating part. This works has broad market prospect, which provides a new idea for large-scaled heating method.
文摘Based on the renovation of sponge and energy-saving facilities in a middle school in Nanning,this paper systematically studies the overall elevation of the campus,the composition of the drainage system and the layout of space functions,and formulates a characteristic scheme for the renovation of sponge and energy-saving facilities according to the characteristics of the sloping campus.In order to control the total amount of rainwater runoff,the sponge transformation mainly adopts the transformation methods of partition catchment,upper storage and lower use,multi-stage detection and classification treatment.For the purpose of solar energy and wind energy utilization,solar photovoltaic panels and small-scale wind power generation system are adopted.The application effects of sponge and energy-saving facilities are estimated and evaluated.