This paper presents the results of an experimental study carried out using large scale equipment to observe the effect of geometry on gas distribution properties of a high capacity corrugated sheet structured packing ...This paper presents the results of an experimental study carried out using large scale equipment to observe the effect of geometry on gas distribution properties of a high capacity corrugated sheet structured packing (Montz-pak B 1-250M) and to compare it with that of its conventional counterpart (Montz-pak B1-250). Although the high capacity packing exhibits a significantly lower overall pressure drop, the gas distribution performance is similar to that of the conventional packing, and in both cases consistently good one.展开更多
This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Vali...This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis.展开更多
文摘This paper presents the results of an experimental study carried out using large scale equipment to observe the effect of geometry on gas distribution properties of a high capacity corrugated sheet structured packing (Montz-pak B 1-250M) and to compare it with that of its conventional counterpart (Montz-pak B1-250). Although the high capacity packing exhibits a significantly lower overall pressure drop, the gas distribution performance is similar to that of the conventional packing, and in both cases consistently good one.
文摘This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis.