期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Development of sintered Ni-Cu wicks for loop heat pipes 被引量:11
1
作者 XIN GongMing CUI KeHang +1 位作者 ZOU Yong CHENG Lin 《Science China(Technological Sciences)》 SCIE EI CAS 2009年第6期1607-1612,共6页
The present study fabricated a series of capillary wicks for loop heat pipes (LHPs), using two different methods, the cold-pressing sintering and direct loose sintering, and experimentally investigated the effect of d... The present study fabricated a series of capillary wicks for loop heat pipes (LHPs), using two different methods, the cold-pressing sintering and direct loose sintering, and experimentally investigated the effect of different methods, compositions and sintering parameters on their properties in terms of porosity, permeability and pore radius. Porosity and pore radius were measured by the Archimedes method and Scanning Electron Microscope (SEM), respectively. Permeability of the wicks was compared by calculation using empirical equation. Results show that capillary wicks were successfully fabricated by using two different methods; the optimal capillary wick was found to be sintered at 650°C for 30 min, using direct loose sintering technique, with 90% nickel and 10% copper. The wicks could reach the porosity of 70.07% and the permeability of 10?13 m2 order, with mean pore radius of 0.54 μm. 展开更多
关键词 loop heat pipe capillary wick SINTERING POROSITY PERMEABILITY pore radius
原文传递
Experimental Studies on Condensation Heat Transferof the Moist Air outside the Horizontal Circular Pipe witha Porous Layer 被引量:1
2
作者 Liu Qiang Zhang Jiaxun Zhong Qi(Beting Institute of Spacecraft System Engineering, R.O. Box 9628-5, Beijing 100086, China) 《Journal of Thermal Science》 SCIE EI CAS CSCD 1999年第2期108-113,共6页
This paper presents the structure design of four kinds of circular pipes with porous layer and the experimental resultsof condensation heat transfer of the moist air outSide the horizontal choular pipes. By comparison... This paper presents the structure design of four kinds of circular pipes with porous layer and the experimental resultsof condensation heat transfer of the moist air outSide the horizontal choular pipes. By comparison with theexperiments on bare Pipes, it is concluded that, the designed pipes not only have good condensation heattransfer Performance, but also have the ability to collect and remove condensed liquid under zero gravity. They canbe aPPlied to the thermal control system for future large spacecraft. 展开更多
关键词 CONDENSATION capillary wick CONVECTION
原文传递
上一页 1 下一页 到第