期刊文献+
共找到1,312篇文章
< 1 2 66 >
每页显示 20 50 100
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
1
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
下载PDF
Efficacy of scleral buckling for the treatment of rhegmatogenous retinal detachment using a novel foldable capsular buckle
2
作者 Fang-Fang Fan Chang Xiao +5 位作者 Liang Wang Xin-Ting Wang Dan-Dan Liu Xing Ge Ya-Lu Liu Su-Yan Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期558-563,共6页
●AIM:To evaluate the effectiveness and safety of scleral buckling for the treatment of rhegmatogenous retinal detachment(RRD)using a novel foldable capsular buckle(FCB).●METHODS:This was a series of case observation... ●AIM:To evaluate the effectiveness and safety of scleral buckling for the treatment of rhegmatogenous retinal detachment(RRD)using a novel foldable capsular buckle(FCB).●METHODS:This was a series of case observation studies.Eighteen patients(18 eyes)who visited our ophthalmology department between August 2020 and August 2022 and were treated for RRD with scleral buckling using FCB were included.The procedure was similar to conventional scleral buckling,while a balloon-like FCB was placed onto the retinal break with balanced salt solution filling for a broad,external indentation instead of the silicone buckle.The retinal reattachment rate,best corrected visual acuity(BCVA),intraocular pressure(IOP),refractive dioptre and astigmatism degree,and complications were evaluated and recorded.●RESULTS:There were 7 males and 11 females aged 19-58y.The average time course of RRD was 12d,ranging from 7-20d.The retinal break was located in the superior quadrants in 8 eyes and in the inferior quadrants in 10 eyes,with macula-off detachments in 12 eyes.The patients were followed-up for at least 6mo.The final retinal reattachment rate was 100%.The BCVA was significantly improved compared with the baseline(P<0.05).There was no significant change in refractive dioptre or astigmatism degree at each follow-up(all P>0.05).Three patients had transiently high IOPs within one week after surgery.Mild diplopia occurred in 5 patients after surgery and then disappeared after the balloon fluid was removed.●CONCLUSION:The success rate of FCB scleral buckling for RRD is satisfactory.This procedure can be expected to be applied in new,uncomplicated cases of RRD. 展开更多
关键词 rhegmatogenous retinal detachment scleral buckling foldable capsular buckle
下载PDF
Nursing Care and Causative Analysis of Grade IV Capsular Contracture Following Breast Cancer Expander Implantation
3
作者 Rong Chen Nan Zhang Huiting Zhang 《Advances in Breast Cancer Research》 CAS 2024年第1期1-9,共9页
Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reason... Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reasons for the formation of capsular contracture after Stage I expander implantation and prevent its recurrence following Stage II reconstruction. Methods: In May 2020, the patient noticed an increase in the size of a breast mass. In August, she underwent AC-THP neoadjuvant chemotherapy, followed by a “right breast-conserving nipple-areolar subglandular excision + right axillary lymph node dissection + expander implantation” surgery in November 2020. Radiation therapy began in January 2021. During radiation therapy, the patient experienced severe breast hardening, distortion, tenderness, and was diagnosed with Grade IV capsular contracture. To relieve the capsular contracture, the patient underwent a “contracted capsule incision and release procedure + removal of the right breast expander + right breast implantation” surgery in July 2021. Postoperatively, measures were taken to prevent incision infection, emphasizing aseptic techniques, ensuring smooth negative pressure drainage, reducing skin flap tension, monitoring skin flap blood supply, actively preventing subcutaneous effusion and hematoma, and applying appropriate compression dressings. Results: The patient was discharged after the removal of the drainage tube. During the postoperative follow-up at 3 and 6 months, there was no recurrence of capsular contracture, and the breast appeared full, upright, and relatively soft. There were no complications such as hematoma, infection, breast implant rupture, breast sagging, or displacement. The patient had a good outcome without additional financial or surgical burdens. Conclusion: The occurrence of Grade IV capsular contracture in the patient is generally related to infection after Stage I expander implantation, improper compression dressing, excessive saline injection causing content infiltration, and radiation therapy. Therefore, it is recommended to enhance the intraoperative and postoperative prophylactic use of antibiotics after Stage I expander implantation. Intermittent saline injection after surgery, with the amount of saline gradually increasing rather than filling all at once, is advisable. This helps the breast tissue gradually adapt to expansion, reducing the risk of capsular contracture. Postoperatively, patients should be instructed to wear pressure garments and breast elastic bandages while intensifying breast monitoring during radiation therapy and increasing postoperative follow-up. 展开更多
关键词 Breast Cancer capsular Contracture Expander Implantation
下载PDF
Stability of neodymium:YAG laser posterior capsulotomy in eyes with capsular tension rings 被引量:1
4
作者 Yang Kyung Cho Min Sun Kim 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第6期891-896,共6页
·AIM: To evaluate the stability of neodymium(Nd):YAG laser posterior capsulotomy in eyes with capsular tension rings(CTRs).·METHODS: A total of 60 eyes that underwent cataract surgery and laser posterior cap... ·AIM: To evaluate the stability of neodymium(Nd):YAG laser posterior capsulotomy in eyes with capsular tension rings(CTRs).·METHODS: A total of 60 eyes that underwent cataract surgery and laser posterior capsulotomy postoperatively were included in this retrospective cohort study. To evaluate the safety and stability of capsulotomy, changes in the size of posterior capsulotomy and anterior chamber depth(ACD) in three groups: the group without CTR, the group with 12 mm CTRs, and the group with 13 mm CTRs, at 1wk, 3, 12, and 15mo after capsulotomy, were compared. ·RESULTS: In the group without CTR and the group with 12 mm CTR, there was no significant change in ACD at every post-laser follow-up. In the group with 13 mm CTR, the ACD change was significant until 3mo after capsulotomy. In all groups, there was a significant increase in the area of capsulotomy between 1wk and 3mo post-laser. Between 3 and 12mo post-laser, only the group with 13 mm CTR showed a significant increase in the area of capsulotomy(P<0.01). ·CONCLUSION: Laser posterior capsulotomy is safe in all three groups. The capsulotomy and ACD become stabilized and have not shown significant changes since 1y postlaser, even with larger CTRs. The maintenance of centrifugal capsular tension can last longer with larger CTRs, and the stability of the capsulotomy site can be reached about 12mo after capsulotomy in pseudophakic eyes with larger CTRs. 展开更多
关键词 Nd:YAG laser CAPSULOTOMY capsular tension ring
下载PDF
Technique of using Cionni-modified capsular tension ring in the management of severely traumatic lens subluxation
5
作者 Hao Jiang Wei Zhang Yan-Hua Chu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1078-1083,共6页
AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule... AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule support and underwent cataract surgery were retrospectively analyzed.Corrected distance visual acuity(CDVA),extent of zonulysis,intraocular lens(IOL)position,intraoperative presentation,and complications were assessed.The primary outcomes included IOL centration stability and other postoperative complications.RESULTS:Twenty patients(20 eyes)were included in this study.The mean age in this study was 58.0±11.3y,and the average follow-up time was 17.3±12.8mo.Capsule bags were saved by Cionni-modified CTR.Nine eyes(45%)underwent simultaneously anterior vitrectomy due to the presence of vitreous in the anterior chamber.The preoperative mean CDVA was 0.83±0.24 log MAR,and the postoperative average CDVA was 0.23±0.30 log MAR(P<0.05).The horizontal and vertical IOL decentration after surgery was 0.27±0.12 mm and 0.41±0.19 mm,respectively;the vertical and horizontal IOL tilt after surgery was 5.5°±2.5°and 6.1°±2.2°,respectively.None of the eyes had obvious IOL decentration during the follow-up time.Eight eyes(40%)had posterior capsule opacification(PCO)that was severe enough to cause poor vision.Neodymium:YAG laser capsulotomy were performed on these eyes when the CTR was stabilized.CONCLUSION:With the help of Cionni-modified CTR,capsular bag preservation and better IOL concentration can be achieved without major complications in patients with severely traumatic subluxated cataracts. 展开更多
关键词 Cionni-modified capsular tension ring subluxated traumatic cataracts surgical technique intraocular lens decentration intraocular lens tilt
下载PDF
Clinical Efficacy and Safety of Foldable Capsular Vitreous Body Implant Surgery in 22 Cases of Silicone Oil-dependent Eyes
6
作者 Yang-yu LIU Qi ZHANG +4 位作者 Yi-quan SHEN Pei-ru MA Rong CHENG Dan CAO Jian-bin CHEN 《Current Medical Science》 SCIE CAS 2023年第2期393-398,共6页
Objective This study aimed to evaluate the clinical efficacy and safety of foldable capsular vitreous body(FCVB)implant surgery in silicone oil-dependent eyes.Methods A total of 22 participants with silicone oil-depen... Objective This study aimed to evaluate the clinical efficacy and safety of foldable capsular vitreous body(FCVB)implant surgery in silicone oil-dependent eyes.Methods A total of 22 participants with silicone oil-dependent eyes who received treatment with FCVB implant surgery between January 2019 and June 2020 were included in this retrospective study.The intraocular pressure(IOP),best-corrected visual acuity(BCVA),demographic data,and any recorded complications were evaluated.Results The postoperative IOP(12.73±4.20 mmHg)was significantly improved(P=0.03)compared to the preoperative IOP(10.23±3.69 mmHg)(the main endpoint).There was no significant difference(P=0.33)in the final BCVA preoperation and 3rd month postoperation(the secondary endpoint).The most common postoperative complication was hyphema.Other common postoperative complications included corneal opacity,a shallow anterior chamber,and a low IOP.Conclusion FCVB implant surgery is a safe and effective method for treating silicone oil-dependent eyes;however,attention should be paid to the prevention and timely treatment of complications. 展开更多
关键词 foldable capsular vitreous body silicone oil-dependent eyes
下载PDF
Surgical treatment of severe anterior capsular organized hard core cataract: A case report
7
作者 Li-Wen Wang Shi-Feng Fang 《World Journal of Clinical Cases》 SCIE 2023年第29期7150-7155,共6页
BACKGROUND Complicated cataract surgery is challenging,especially in cases of hard nuclear cataract with severe anterior capsule organization.It is important to avoid the risk of surgery and improve the surgical skill... BACKGROUND Complicated cataract surgery is challenging,especially in cases of hard nuclear cataract with severe anterior capsule organization.It is important to avoid the risk of surgery and improve the surgical skills of surgeons.CASE SUMMARY A 60-year-old man presented with severe cataract and visual impairment.The anterior capsule of the lens was irregularly organized and pulled to the surrounding capsule,and white porcelain organized cord and brown-black lens nucleus were clearly visible.In phacoemulsification,maintaining the anterior capsule round and intact plays a key role in a successful surgery.In this case,if the conventional capsule treatment method was used,the anterior capsule would be torn.Therefore,we adopted a segmented anterior capsule treatment method,and a blasting method to release energy when dealing with the lens nucleus,and achieved good surgical results.CONCLUSION Complicated cataract surgery is challenging and requires precise skills.Operation plans should be made reasonably to predict the risk of surgery,and improve the visual quality of the patients. 展开更多
关键词 Complex cataract Surgery treatment Hard core cataract Clinical treatment Anterior capsular organized Case report
下载PDF
“NIR-triggered ROS storage”photodynamic intraocular implant for high-efficient and safe posterior capsular opacification prevention
8
作者 Yanjuan Huang Tao Zhang +5 位作者 Qin Wei Zishan Zeng Yujun Gong Xiaoyu Xu Meixu Chen Chunshun Zhao 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2022年第6期838-854,共17页
Posterior capsular opacification(PCO)is the leading cause of vision loss after cataract,mainly caused by the adhesion,proliferation and trans-differentiation of post-operative residual lens epithelial cells(LECs).Effe... Posterior capsular opacification(PCO)is the leading cause of vision loss after cataract,mainly caused by the adhesion,proliferation and trans-differentiation of post-operative residual lens epithelial cells(LECs).Effective PCO prevention remains a huge challenge to ophthalmologists and researches for decades.Herein,we developed a“NIR-triggered ROS storage”intraocular implant(CTR-Py-Pp IX)based on capsular tension ring(CTR),which is concurrently linked with photosensitizer protophorphyrin IX(Pp IX)and energy storage2-pyridone derivative(Py),to guarantee instantaneous and sustainable ROS generation for LECs killing,aiming to achieve more efficient and safer photodynamic therapy(PDT)to effectively prevent PCO.The silylated Pp IX-Si and Py-Si were covalently conjugated to the plasma activated CTR surface to obtain CTR-Py-Pp IX.Results demonstrated that CTR-Py-Pp IX had dual functions of PDT and battery,in which Pp IX could generate ROS extracellularly under irradiation,with one part directly inhibiting LECs by lipid peroxidation(LPO)induction of cell membranes.Meanwhile,the excess ROS stored in Py could be continuously released to amplify LPO levels after the irradiation was removed.Ultimately,the proliferation of LECs in capsular bag was completely inhibited under mild irradiation conditions,achieving a sustainable and controlled PDT effect for effective PCO prevention with good biocompatibility.This NIR-triggered ROS storage intraocular implant would provide a more efficient and safer approach for long-term PCO prevention. 展开更多
关键词 Posterior capsular opacification capsular tension ring Photodynamic therapy ENDOPEROXIDE
下载PDF
Application of sustained delivery microsphere of cyclosporine A for preventing posterior capsular opacification in rabbits 被引量:6
9
作者 Cheng Pei Yi Xu +3 位作者 Jean Xin.Jiang Li-Jun Cui Li Li Li Qin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第1期1-7,共7页
AIM:To explore the inhibitory effect of a sustained cyclosporin A (CsA) delivery microsphere (CsA-MS) on posterior capsular opacification (PCO) in rabbit eyes after cataract extraction. ·METHODS:Twenty New Zealan... AIM:To explore the inhibitory effect of a sustained cyclosporin A (CsA) delivery microsphere (CsA-MS) on posterior capsular opacification (PCO) in rabbit eyes after cataract extraction. ·METHODS:Twenty New Zealand white rabbits accepted cataract extraction plus intraocular lens implantation and their left eyes were intraoperatively injected CsA-MS prepared using polymer polylactioglycolic acid (PLGA) as a carrier and their right eyes were injected with empty MS. The changes in cornea, anterior chamber reaction, intraocular pressure, PCO and CsA concentration in aqueous humor were examined postoperatively and all the eyes were enucleated 3 months after surgery for histopathological and morphological examination with light microscopy and electron microscopy. · RESULTS:Conjunctival hyperemia, corneal edema, intraocular pressure and anterior chamber response of experimental and control eyes were similar, while PCO in CsA MS injected eyes was greatly improved compared with that in control eyes. Posterior capsules in CsA-MS injected eyes were smooth and lens epithelial cells (LEC) did not proliferate significantly (P >0.05), while LEC in posterior capsule of control eyes had different degrees of proliferation and cortical regeneration. LEC in CsA-MS injected eyes were not functionally active and underwent apoptosis, whereas LEC in control eyes were functionally active (F-test, P =0.025). In addition, the cornealultrastructure showed no differences between CsA-MS and MS injected eyes. CONCLUSION:CsA-MS has high bioavailability in rabbit eyes and could inhibit postoperative PCO occurrence and development during the study period, suggesting that CsA-MS may be a promising, effective and safe administration route to prevent PCO in clinic. 展开更多
关键词 SUSTAINED CYCLOSPORINE A delivery mic-rosphere POSTERIOR capsular OPACIFICATION rabbit eyes
下载PDF
Comparative evaluation of rotational stability of toric IOLs with four-eyelet vs two-eyelet capsular tension rings in eyes with high myopia 被引量:7
10
作者 Hui-Min Jiang Kun Liang Li-Ming Tao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第3期378-382,共5页
AIM:To compare the rotational stability of Toric intraocular lens(IOLs)implantation combined with foureyelet or two-eyelet capsular tension rings(CTRs)in eyes with high myopia and cataract.METHODS:This prospective ran... AIM:To compare the rotational stability of Toric intraocular lens(IOLs)implantation combined with foureyelet or two-eyelet capsular tension rings(CTRs)in eyes with high myopia and cataract.METHODS:This prospective randomized controlled interventional study in cluded 33 eyes which had preoperative corneal astigmatism≥1.5 D and ocular axial length≥25.5 mm.These eyes were randomly divided into two groups to undergo phacoemulsification and toric IOL implantation with either four-eyelet CTR implantation(group A,n=16)or two-eyelet CTR implantation(group B,n=17).Uncorrected visual acuity(UCVA),best-corrected visual acuity(BCVA),phoropter examination results,and toric IOL rotation degrees were tested 6 mo after the surgery.RESULTS:In both groups,the toric IOL was in the capsular sac 6 mo after surgery.The difference between the two groups in terms of visual outcome was not found to be statistically significant(P>0.05)at a follow-up of 6 mo.The mean residual astigmatism values were 0.56±0.22 D and 0.92±0.24 D in A and B groups,respectively(P<0.001).The mean rotation degree of IOL was 1.00°±0.73°in group A and 3.53°±1.46°in group B(P<0.001).CONCLUSION:In cataract patients with high myopia and astigmatism,four-eyelet CTR can effectively increase the rotation stability of toric IOLs,achieving the desired goal of correcting corneal astigmatism. 展开更多
关键词 capsular tension ring toric intraocular lens CATARACT axial myopic astigmatism
下载PDF
Theoretical study on conformational conversion of 1,3-dioxane inside a capsular host 被引量:2
11
作者 Ju Wang Zuo Yin Yang +2 位作者 Xiu Li Wang Jing Chang Zhang Wei Liang Cao 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第2期244-246,共3页
The conformational conversion of 1,3-dioxane guest encapsulated inside a cylindrical capsular host was investigated with PM3 method and single point energies were evaluated by B3LYP method. When entrapped in the capsu... The conformational conversion of 1,3-dioxane guest encapsulated inside a cylindrical capsular host was investigated with PM3 method and single point energies were evaluated by B3LYP method. When entrapped in the capsule, the guest tumbles were slower than that in the free condition. The influences of the inner phase of the capsule on the guest conformational conversion were discussed in detail. 展开更多
关键词 Complex CYLINDRICAL capsular HOST Quantum CHEMISTRY Reaction mechanism
下载PDF
Evaluation of the long-term effect of foldable capsular vitreous bodies in severe ocular rupture 被引量:4
12
作者 Jin Deng Hu-Ping Song +3 位作者 Rong-Le Zhou Tao Chen Jian-Zhou Wang Zhao-Liang Zhu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第12期1935-1940,共6页
AIM:To evaluate the long-term effect of foldable capsular vitreous body(FCVB)in the treatment of severe ocular rupture to provide a practical basis for clinical selection.METHODS:A total of 26 patients(26 eyes),23 men... AIM:To evaluate the long-term effect of foldable capsular vitreous body(FCVB)in the treatment of severe ocular rupture to provide a practical basis for clinical selection.METHODS:A total of 26 patients(26 eyes),23 men and 3 women,with severe ocular rupture who underwent FCVB implantation between March 2018 and September 2018 were retrospectively analysed.All open ocular wounds located in zone III,with preoperative visual acuity grade IV and above(Snellen less than 4/200).The best corrected visual acuity(BCVA),intraocular pressure(IOP),cornea,anterior chamber,iris,lens,choroid,and retina were evaluated before and after the surgery.The subjective feeling and the location of FCVB were also assessed.RESULTS:The average age of the 26 patients was 36y(20-60y).Postoperative follow-up was from 10 to 14mo.At the end of follow up,BCVA was light perception(LP)in 10 cases,no light perception(NLP)in 13 cases,hand motions(HM)in 3 cases.IOP was 11±5 mm Hg.Corneal degeneration was in 3 cases and corneal endothelial dystrophy was in 7 cases.Shallow anterior chamber was in 8 cases and hyphema was in 8 cases.Organized membrane in the pupil was in 14 cases.Epiphora occurred in 3 cases.FCVB drainage tube exposed in 3 cases.All FCVBs were in their normal location and no rejection occurred.CONCLUSION:FCVB implantation is a long-term effective treatment and may provide a practical selection for severe ocular rupture. 展开更多
关键词 foldable capsular vitreous body severe ocular rupture long-term effect
下载PDF
Effect of capsular tension ring implantation on predicted refractive error after cataract surgery in patients with pseudoexfoliation syndrome 被引量:2
13
作者 Mohammad Malekahmadi Sadegh Kazemi +3 位作者 Farideh Sharifipour Farshad Ostadian Atefeh Mahdian Rad Mohammad Sadegh Mirdehghan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第4期587-590,共4页
AIM: To investigate the effect of capsular tension ring(CTR) implantation on predicted refractive error after cataract surgery in patients with pseudoexfoliation(PEX) syndrome.METHODS: This double-blind randomized cli... AIM: To investigate the effect of capsular tension ring(CTR) implantation on predicted refractive error after cataract surgery in patients with pseudoexfoliation(PEX) syndrome.METHODS: This double-blind randomized clinical trial was conducted on 60 patients with PEX syndrome referring to Imam Khomeini Hospital affiliated to Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran, for undergoing cataract surgery. The study population was divided into two groups, namely CTR group(n=30) and non-CTR group(control group;n=30). The refractive error and anterior chamber depth(ACD) were measured 1 wk, 1 mo, and 3 mo after phacoemulsification(PE) surgery.RESULTS: The results indicated no statistically significant difference between the two groups in terms of predicted refractive error(obtained by subtracting preoperative predicted refractive error from actual postoperative refractive error) 1 wk(P=0.47), 1 mo(P=0.30), and 3 mo(P=0.06) after the PE surgery. Regarding the CTR group, the changes of ACD was statistically significant 1 and 3 mo after the PE surgery, compared to those obtained 1 wk post-surgery(P=0.005).CONCLUSION: The CTR implantation in PEX cataractous patients without zonulysis has no statistically significant effect on the predicted refraction and ACD changes after PE. The predicted refraction error has a hyperopic shift in both groups. The results reveal the unnecessary of calculating modified IOL in CTR implantation. 展开更多
关键词 PSEUDOEXFOLIATION syndrome capsular tension ring REFRACTION error ANTERIOR CHAMBER
下载PDF
Arthroscopic Capsular Release for Frozen Shoulder—Time to Thaw the Delay? 被引量:2
14
作者 Christopher Munro Scott L. Barker Kapil Kumar 《Surgical Science》 2013年第9期22-24,共3页
Introduction: Frozen shoulder is a common condition that affects the working population. Current management regimes are variable nationwide and the evidence base on which to base these decisions is poor. The longevity... Introduction: Frozen shoulder is a common condition that affects the working population. Current management regimes are variable nationwide and the evidence base on which to base these decisions is poor. The longevity and severity of symptoms often result in great economic burden, both to health services and in terms of absence from work. Early surgical intervention with arthroscopic capsular release may result in improved symptoms and earlier return to both work and leisure activities. Aims: The aim of our prospective cohort study was to investigate whether early intervention with arthroscopic capsular release resulted in improvement of symptoms and whether this would in turn provide overall economic benefit to society. Methods: Patients diagnosed with frozen shoulder at an elective orthopaedic specialist shoulder clinic were recruited prospectively. Data were gathered by way of questionnaire to ascertain the demographic information of the patient as well as their previous treatment in the primary care setting and absence from work. Initial Oxford Shoulder Score (OSS) was also calculated: Arthroscopic capsular release was then performed and further data gathered at four-week post-operative follow-up. Economic impact of delay to treatment and cost of intervention were calculated using government data from the national tariff which cost different forms of treatment. Statistical analysis was then performed on the results. Results: Twenty five patients were recruited. Mean results were: Age of patients: 53.5 years, duration of symptoms prior to intervention: 35.2 weeks, days absent from work: 31.5, number of previous physiotherapy sessions: 7.2, number of steroid injections: 1.3. Mean pre-operative OSS was 37.4 (range 27 - 58, SD 7.4). Mean post-operative OSS was 15.9 (range 12 - 22, SD 2.3), P 0.01. Mean improvement in OSS was 21.5 (range 12 - 38, SD 7.1). The cost of non-operative treatment per patient including absence from work to the point of surgical intervention was £3954. The overall cost of arthroscopic capsular release per patient was £1861, a difference of £2093. There were no surgical complications. Conclusion: Arthroscopic capsular release improved shoulder function on OSS within four weeks. This is significantly shorter than the natural history of frozen shoulder. The overall cost of arthroscopic capsular release is significantly less than the cost of treating the patients non-operatively up to the point of surgical intervention. Early surgical intervention may improve symptoms quickly and reduce economic burden of the disease. A randomised controlled trial comparing early with late intervention would further elucidate potential benefits. 展开更多
关键词 FROZEN SHOULDER ADHESIVE Capsulitis capsular Release ARTHROSCOPIC ECONOMICS
下载PDF
Genetic Characteristics of Lipooligosaccharide and Capsular Polysaccharide of Campylobacter jejuni from Different Sources in China 被引量:1
15
作者 WANG Jia Qi CHEN Xiao Li +5 位作者 ZHOU Gui Lan WANG Hai Rui GU Yi Xin ZHANG Jian Zhong SHAO Zhu Jun ZHANG Mao Jun 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2022年第12期1106-1114,共9页
Objective To determine the distribution of two important virulence factors[lipooligosaccharide(LOS)and capsular polysaccharide(CPS)]in Campylobacter jejuni(C.jejuni)isolated from different sources in China and to deve... Objective To determine the distribution of two important virulence factors[lipooligosaccharide(LOS)and capsular polysaccharide(CPS)]in Campylobacter jejuni(C.jejuni)isolated from different sources in China and to develop a rapid screening method for Guillain–Barrésyndrome(GBS)-associated strains.Methods Whole-genome sequencing was carried out for 494 C.jejuni strains.The Ortho MCL software was used to define the LOS/CPS gene clusters.CPS genotyping was performed with serotype-specific sequence alignment using the BLAST software.Real-time Polymerase chain reaction(PCR)was developed with the unique sequences of specific CPS types.Results Nine novel and 29 previously confirmed LOS classes were identified.LOS classes A,B,and C were the most common(48.2%,238/494)among the 494 strains.Twenty-six capsular types were identified in 448 strains.HS2,HS4c,HS5/31,HS19,and HS8/17 were the most frequent CPS genotypes(58.7%,263/448).Strains of 17 CPS genotypes(strain number>5)had one or two prevalent LOS classes(P<0.05).Multiplex real-time PCR for rapid identification of HS2,HS19,and HS41 was developed and validated with strains of known serotypes.Conclusion Our results describe the genetic characteristics of the important virulence factors in C.jejuni strains in China.The multiplex real-time PCR developed in this study will facilitate enhanced surveillance of GBS-associated strains in China. 展开更多
关键词 Campylobacter jejuni LIPOOLIGOSACCHARIDE capsular polysaccharide Multiplex real-time PCR
下载PDF
Capsular polysaccarides of probiotics and their immunomodulatory roles 被引量:1
16
作者 Jing Li Saisai Feng +4 位作者 Leilei Yu Jianxin Zhao Fengwei Tian Wei Chen Qixiao Zhai 《Food Science and Human Wellness》 SCIE 2022年第5期1111-1120,共10页
Studies have determined the immunomodulatory activities of cell-surface polysaccharides of lactic acid bacteria(LAB)and Bacteroides;however,the mechanisms,synthesis,regulation,structure,and functional links have not b... Studies have determined the immunomodulatory activities of cell-surface polysaccharides of lactic acid bacteria(LAB)and Bacteroides;however,the mechanisms,synthesis,regulation,structure,and functional links have not been systematically discussed.We first introduce the structure of the capsular poly saccharides(CPS s)of commonly studied probiotics and Bacteroides.Wzx-Wzy dependent and ATP-binding cassette(ABC)transporter-dependent pathways are the two main biosynthesis and secretion of CPS pathways.The genes known to be associated with these two pathways are mainly those associated with priming glycosyltransferase(pGT);a variable number of genes encoding for different glycosyl transferases(GTs);Wzx/Wzy-encoding enzymes related to flippases and polymerases;and ABC-transporter genes.In addition,the effects of CPSs on host immunity as well as their related underlying mechanisms are described.Surface polysaccharides on probiotics can serve as a mask to aid in their escape from attacks from the host’s immune system.In turn,they also exhibit immunomodulatory activities,such as strengthening the functions of macrophages,promoting the maturation of antigen-presenting cells,and inducing regulatory T cells.All of these effects of cell-surface polysaccharides exhibit their significant protective properties in immunocompromised diseases,such as colitis,arthritis,and dermatitis.Finally,we focused on their structure and functional links. 展开更多
关键词 capsular polysaccharides PROBIOTICS BACTEROIDES IMMUNOMODULATION
下载PDF
Characterization of BellaGel SmoothFine<sup>&#174;</sup>Implant Surfaces and Correlation with Capsular Contracture 被引量:1
17
作者 Sun-Young Nam Miji Lee +5 位作者 Byung Ho Shin Bassem Elfeky Yang U. Lee Dae Hee Moon Daeun Seo Chan Yeong Heo 《Journal of Biomaterials and Nanobiotechnology》 2019年第4期196-211,共16页
BellaGel SmoothFine&#174;implant is a novel nanotextured silicone breast implant. The objective of this study was to characterize differences of BellaGel SmoothFine&#174;surfaces with commercial available impl... BellaGel SmoothFine&#174;implant is a novel nanotextured silicone breast implant. The objective of this study was to characterize differences of BellaGel SmoothFine&#174;surfaces with commercial available implant surfaces in terms of texture, topography, and wettability as well as the behavior of capsular contracture. The surface textures of breast implants from two different manufacturers (Hans Biomed and Motiva) were evaluated. The implants utilized in this study were BellaGel Smooth&#174;, BellaGel Textured&#174;, BellaGel SmoothFine&#174;?or Motiva SilkSurface&#174;. The shell textures of these implants were characterized using a scanning electron microscopy, three dimensional confocal laser scanning microscope, and contact angle goniometer. Silicone breast implants were emplaced beneath the panniculus carnosus muscle on the dorsum of Sprague Dawley rats and observed for up to 8 weeks postoperative days. The fibrous capsules around silicone implants were explanted for histological examination. BellaGel SmoothFine&#174;exhibits a relatively flat, with little or no depth in the texturing, 5.96 ± 0.41 μm surface roughness, and a contact angle of 103.14 ± 2.06 BellGel SmoothFine&#174;implant resulted in significant decreases in capsule thickness (P P &#174;and BellaGel Textured&#174;implant groups. Significant (P &#174;. Fibrous tissue formation markers (Vimentin and alpha-smooth muscle actin) were significantly reduced in BellaGel SmoothFine&#174;surfaces versus BellaGel Smooth&#174;surfaces (P &#174;groups (P &#174;implant is associated with less breast implant derived capsular contracture than other surfaces. 展开更多
关键词 SILICONE Breast IMPLANT capsular CONTRACTURE TOPOGRAPHY Roughness iNOS
下载PDF
Posterior Capsular Rent: Risk Factors, Diagnosis and Management 被引量:1
18
作者 Nimmi Rani Prashant Gupta 《Surgical Science》 2014年第5期224-226,共3页
In spite of a steady improvement in the safety of cataract surgery since the inception of phacoemulsification, diagnosing and managing posterior capsular rent still remains a challenge. Identification of the pre-exist... In spite of a steady improvement in the safety of cataract surgery since the inception of phacoemulsification, diagnosing and managing posterior capsular rent still remains a challenge. Identification of the pre-existing risk factors is of utmost importance so that precautionary modifications are done in the surgery to prevent this complication. Once it happens, timely realization and appropriate management can have excellent outcomes. 展开更多
关键词 POSTERIOR capsular RENT Vitreous Loss Traumatic Cataract Small Pupil PSEUDOEXFOLIATION Vitrectomy TRIAMCINOLONE ACETONIDE
下载PDF
Unilateral spontaneous lens absorption and dislocation of the empty capsular bag into the anterior chamber 被引量:1
19
作者 Bo Hee Kim Deoksun Cha +3 位作者 Sunmin Yim Ji-Won Kwon Won Ryang Wee Young Keun Han 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第1期161-164,共4页
Dear Editor,C ases involving spontaneous aphakic change in the visual axis are rare in Outpatient Clinics.However,we can often ascertain the past events affecting the patient’s eye by examining its current status.The... Dear Editor,C ases involving spontaneous aphakic change in the visual axis are rare in Outpatient Clinics.However,we can often ascertain the past events affecting the patient’s eye by examining its current status.The placement of the 展开更多
关键词 Unilateral spontaneous lens absorption and dislocation of the empty capsular bag into the anterior chamber Figure IOL
下载PDF
Pasteurella multocida capsular:lipopolysaccharide types D:L6 and A:L3 remain to be the main epidemic genotypes of pigs in China 被引量:1
20
作者 Songtao Liu Lin Lin +12 位作者 Hao Yang Wenqing Wu Long Guo Yue Zhang Fei Wang Xueying Wang Wenbo Song Lin Hua Wan Liang Xibiao Tang Huanchun Chen Zhong Peng Bin Wu 《Animal Diseases》 2021年第4期262-267,共6页
Pasteurella multocida is a leading cause of respiratory disorders in pigs.This study was designed to understand the genotypical and antimicrobial resistant characteristics of P.multocida from pigs in China.To achieve ... Pasteurella multocida is a leading cause of respiratory disorders in pigs.This study was designed to understand the genotypical and antimicrobial resistant characteristics of P.multocida from pigs in China.To achieve this,we briefly investigated 158 P.multocida isolates from pigs with respiratory disorders in China between 2019 and 2020.Genotyping through multiplex PCR assays assigned these 158 isolates into capsular genotypes A(60.13%,95/158),D(35.44%,56/158),F(4.43%,7/158),and/or lipopolysaccharide(LPS)genotypes L3(28.48%,45/158)and L6(66.46%,105/158).In addition,eight isolates(5.06%,8/158)were found to be nontypable using the LPS genotyping method.When combining the capsular genotypes and the LPS genotypes,D:L6(34.81%,55/158)and A:L6(31.65%,50/158)were the predominant genotypes,followed by A:L3(24.05%,38/158).PCR detection of virulence factor-encoding genes showed that over 80%of the isolates were positive for exbB,tonB,exbD,ompH,ptfA,fimA,sodA,sodC,fur,ompA,oma87,plpB,hsf-2,nanH and hgbB,suggesting the presence of these genes were broad characteristics of P.multocida.We also found approximately 63.92%(101/158),51.27%(81/158),8.86%(14/158),7.59%(12/158),3.16%(5/158),0.63%(1/158),and 0.63%(1/158)of the isolates grew well in media with the presence of colistin(4μg/mL),tetracycline(16μg/mL),tigecycline(1μg/mL),ampicillin(32μg/mL),chloramphenicol(32μg/mL),cefepime(16μg/mL),and ciprofloxacin(1μg/mL),respectively.This study contributes to the understanding of genotypes and antimicrobial resistance profile of P.multocida currently circulation in pigs of China. 展开更多
关键词 Pasteurella multocida capsular and LPS genotypes Virulence factor-encoding genes Antimicrobial susceptibility PIGS China
下载PDF
上一页 1 2 66 下一页 到第