The first imported off-gas analysis system on 150 t BOF at Benxi Plates Co.Ltd. is presented and the continuous determination of bath carbon content has been studied. Thecomparison between the whole-course carbon inte...The first imported off-gas analysis system on 150 t BOF at Benxi Plates Co.Ltd. is presented and the continuous determination of bath carbon content has been studied. Thecomparison between the whole-course carbon integral model and the end-point carbon prediction modelhas been made. The results show that the regular change of CO, CO_2 and N_2 content in the off-gasduring blowing plays an important role in judging the smelting end-point of converter; the cubiccurve fitting model has a higher hit rate over 95 percent for the heats whose end-point carboncontent is lower than 0.10 percent with a precision of +-0.02 percent and has a large error for theheats whose end-point carbon content is more than 0.15 percent.展开更多
GB/T 13245-91 1 Theme and Scope This standard specifies the method abstract, reagents, apparatus, specimen, analyzing procedure, result calculation and permissible tolerance used for determination of the total carbon ...GB/T 13245-91 1 Theme and Scope This standard specifies the method abstract, reagents, apparatus, specimen, analyzing procedure, result calculation and permissible tolerance used for determination of the total carbon with combustion gravimetric method.展开更多
Nowadays, modified electrodes with metal nanoparticles have appeared as an alternative for the electroanalysis of various compounds. In this study, gold nanoparticles(GNPs) were chosen as interesting metal nanoparti...Nowadays, modified electrodes with metal nanoparticles have appeared as an alternative for the electroanalysis of various compounds. In this study, gold nanoparticles(GNPs) were chosen as interesting metal nanoparticles for modifying carbon paste electrode(CPE). GNPs and the gold nanoparticles-modified carbon paste electrode(GNPs/CPE) were characterized by UV–Vis spectroscopy, transmission electron microscopy(TEM) and scanning electron microscopy(SEM). GNPs/CPE as a simple and sensitive electrode was used to study three important biological molecules: folic acid(FA), uric acid(UA) and ascorbic acid(AA). Square wave voltammetry(SWV) was used as an accurate technique for quantitative measurements. A good linear relation was observed between anodic peak current(ipa) and FA(5.2 × 10(-6)– 2.5 × 10(-5)M), UA(1.2 × 10(-6)– 2.1 × 10(-5)M) and AA(1.2 × 10(-6)– 2.5 × 10(-5)M) concentrations in simultaneous determination of these molecules.展开更多
A new all-solid-state carbonate ion-selective electrode was fabricated via electrochemical and ion-exchange reactions with Ag nanoparticles and Ag2CO3-BaCO3 as ion-to-electron transducer and ion-selective layer, respe...A new all-solid-state carbonate ion-selective electrode was fabricated via electrochemical and ion-exchange reactions with Ag nanoparticles and Ag2CO3-BaCO3 as ion-to-electron transducer and ion-selective layer, respectively. This paper presented the detailed procedures of the construction of the electrode, the applications of the electrode in various experiments, and the corresponding chemical reaction principles involved. The fabricated electrode was characterized by means of scanning electron microscopy(SEM), energy dispersive spectrometer(EDS), and electrochemical analyses. The electrode exhibited stable linear responses to carbonate anions(10-5--10-1 mol/L) with average Slope of the curve being -26.56 mV per decade, and showed negligible responses to NO3, SO2-, and Sal- anions. The electrode was further used to measure the concentration of carbonate anions in boiler water. The measured concentration was lower than that determined via titration. Overall, the electrode exhibited the advantages of miniaturized size, robust construction, and compatibility with other equipment and thus could be ideally integrated into various sensor platforms to collect chemical data from industrial heat exchangers.展开更多
文摘The first imported off-gas analysis system on 150 t BOF at Benxi Plates Co.Ltd. is presented and the continuous determination of bath carbon content has been studied. Thecomparison between the whole-course carbon integral model and the end-point carbon prediction modelhas been made. The results show that the regular change of CO, CO_2 and N_2 content in the off-gasduring blowing plays an important role in judging the smelting end-point of converter; the cubiccurve fitting model has a higher hit rate over 95 percent for the heats whose end-point carboncontent is lower than 0.10 percent with a precision of +-0.02 percent and has a large error for theheats whose end-point carbon content is more than 0.15 percent.
文摘GB/T 13245-91 1 Theme and Scope This standard specifies the method abstract, reagents, apparatus, specimen, analyzing procedure, result calculation and permissible tolerance used for determination of the total carbon with combustion gravimetric method.
基金the Post-graduate Office of Guilan University(A-384579)for supporting
文摘Nowadays, modified electrodes with metal nanoparticles have appeared as an alternative for the electroanalysis of various compounds. In this study, gold nanoparticles(GNPs) were chosen as interesting metal nanoparticles for modifying carbon paste electrode(CPE). GNPs and the gold nanoparticles-modified carbon paste electrode(GNPs/CPE) were characterized by UV–Vis spectroscopy, transmission electron microscopy(TEM) and scanning electron microscopy(SEM). GNPs/CPE as a simple and sensitive electrode was used to study three important biological molecules: folic acid(FA), uric acid(UA) and ascorbic acid(AA). Square wave voltammetry(SWV) was used as an accurate technique for quantitative measurements. A good linear relation was observed between anodic peak current(ipa) and FA(5.2 × 10(-6)– 2.5 × 10(-5)M), UA(1.2 × 10(-6)– 2.1 × 10(-5)M) and AA(1.2 × 10(-6)– 2.5 × 10(-5)M) concentrations in simultaneous determination of these molecules.
文摘A new all-solid-state carbonate ion-selective electrode was fabricated via electrochemical and ion-exchange reactions with Ag nanoparticles and Ag2CO3-BaCO3 as ion-to-electron transducer and ion-selective layer, respectively. This paper presented the detailed procedures of the construction of the electrode, the applications of the electrode in various experiments, and the corresponding chemical reaction principles involved. The fabricated electrode was characterized by means of scanning electron microscopy(SEM), energy dispersive spectrometer(EDS), and electrochemical analyses. The electrode exhibited stable linear responses to carbonate anions(10-5--10-1 mol/L) with average Slope of the curve being -26.56 mV per decade, and showed negligible responses to NO3, SO2-, and Sal- anions. The electrode was further used to measure the concentration of carbonate anions in boiler water. The measured concentration was lower than that determined via titration. Overall, the electrode exhibited the advantages of miniaturized size, robust construction, and compatibility with other equipment and thus could be ideally integrated into various sensor platforms to collect chemical data from industrial heat exchangers.