An ultrasensitive electrochemical sensor based on polydopamine/carboxylic multi-walled carbon nanotubes(MWCNTs à COOH) nanocomposites modified glassy carbon electrode(GCE) was presented in this work, which has be...An ultrasensitive electrochemical sensor based on polydopamine/carboxylic multi-walled carbon nanotubes(MWCNTs à COOH) nanocomposites modified glassy carbon electrode(GCE) was presented in this work, which has been developed for highly selective and highly sensitive determination of an antimicrobial drug, metronidazole. The preparation of polydopamine/MWCNTs–COOH nanocomposites/GCE sensor is simple and possesses high reproducible, where polydopamine can be coated on the surface of MWCNTs–COOH via a simple electropolymerization process. Under optimized conditions, the proposed sensor showed ultrasensitive determination for metronidazole with a wide linear detection range from5 to 5000 mmol/dm^3 and a low detection limit of 0.25 mmol/dm^3(S/N=3). Moreover, the proposed sensor has been successfully applied for the quantitative determination of metronidazole in real drug samples. This work may provide a novel and effective analytical platform for determination of metronidazole in application of real pharmaceutical and biological samples analysis.展开更多
Due to its properties of mutagenic,teratogenic,and carcinogenic,the detection of furazolidone(FZD)in aquaculture is of great importance for food safety and human health.In this study,molecularly imprinted fi lms modif...Due to its properties of mutagenic,teratogenic,and carcinogenic,the detection of furazolidone(FZD)in aquaculture is of great importance for food safety and human health.In this study,molecularly imprinted fi lms modifi ed with carboxylated multi-walled carbon nanotube-phosphomolybdic acid composite were used to fabricate an electrochemical sensor for the determination of FZD.The nanocomposites were characterized using infrared spectroscopy,scanning electron microscopy,energy-dispersive X-ray spectroscopy,and X-ray diff raction.The electrochemical characteristics of the modifi ed electrodes were examined using electrochemical impedance spectroscopy,cyclic voltammetry,and diff erential pulse voltammetry.The sensor exhibited exceptional catalytic performance.The calibration curves were acquired in the concentration range of 6 nmol·L^(−1)to 0.6μmol·L^(−1),with a limit of detection of 3.38 nmol·L^(−1).Additionally,the sensor proved successful in recognizing FZD in shrimp samples with satisfactory recoveries and precision.The method provides a strategy to construct a molecularly imprinted electrochemical sensing platform using nanomaterials,which has great promise in the field of food safety.展开更多
The wear behavior of multi-walled carbon nano-tubes(MWCNTs)reinforced copper metal matrix composites(MMCs)processed through powder metallurgy(PM)route was focused on and further investigated for varying MWCNT quantity...The wear behavior of multi-walled carbon nano-tubes(MWCNTs)reinforced copper metal matrix composites(MMCs)processed through powder metallurgy(PM)route was focused on and further investigated for varying MWCNT quantity viaexperimental,statistical and artificial neural network(ANN)techniques.Microhardness increases with increment in MWCNTquantity.Wear loss against varying load and sliding distance was analyzed as per L16orthogonal array using a pin-on-disctribometer.Process parameter optimization by Taguchi’s method revealed that wear loss was affected to a greater extent by theintroduction of MWCNT;this wear resistant property of newer composite was further analyzed and confirmed through analysis ofvariance(ANOVA).MWCNT content(76.48%)is the most influencing factor on wear loss followed by applied load(12.18%)andsliding distance(9.91%).ANN model simulations for varying hidden nodes were tried out and the model yielding lower MAE valuewith3-7-1network topology is identified to be reliable.ANN model predictions with R value of99.5%which highly correlated withthe outcomes of ANOVA were successfully employed to investigate individual parameter’s effect on wear loss of Cu?MWCNTMMCs.展开更多
The effects of different cation concentrations and types on rheological property and stability of Guar, Xanthan, and Partially Hydrolyzed Polyacrylamide(HPAM) cross-linked gels were analyzed through experiments. Also,...The effects of different cation concentrations and types on rheological property and stability of Guar, Xanthan, and Partially Hydrolyzed Polyacrylamide(HPAM) cross-linked gels were analyzed through experiments. Also, a new approach was developed to reduce the negative effects of cation by application of multi-walled carbon nano-tubes(MWCNTs). The presence of cations in cross-linked gel system will reduce the viscosity of gel, the higher the cation concentration is, the lower the viscosity will be. The bivalent cation has a greater viscosity reduction effect on gel than monovalent cation. The stability of cross-linked gels is worse with cations, this situation becomes more serious under higher salinity. MWCNTs were added to HPAM gel, cross-linked by(3-Aminopropyl) triethoxysilane(APTES), they surrounded cations and removed them from polymers and reduced the reaction possibility. This method enhances the viscosity and breakdown pressure of cross-linked gels, improves the stability of HPAM cross-linked gel under different operating conditions, and can be applied to related drilling projects.展开更多
基金financially supported by the National Natural Science Foundation of China(Grant Nos.21475046,21427809)
文摘An ultrasensitive electrochemical sensor based on polydopamine/carboxylic multi-walled carbon nanotubes(MWCNTs à COOH) nanocomposites modified glassy carbon electrode(GCE) was presented in this work, which has been developed for highly selective and highly sensitive determination of an antimicrobial drug, metronidazole. The preparation of polydopamine/MWCNTs–COOH nanocomposites/GCE sensor is simple and possesses high reproducible, where polydopamine can be coated on the surface of MWCNTs–COOH via a simple electropolymerization process. Under optimized conditions, the proposed sensor showed ultrasensitive determination for metronidazole with a wide linear detection range from5 to 5000 mmol/dm^3 and a low detection limit of 0.25 mmol/dm^3(S/N=3). Moreover, the proposed sensor has been successfully applied for the quantitative determination of metronidazole in real drug samples. This work may provide a novel and effective analytical platform for determination of metronidazole in application of real pharmaceutical and biological samples analysis.
基金Supported by the National Natural Science Foundation of China(Grant No.22271119).
文摘Due to its properties of mutagenic,teratogenic,and carcinogenic,the detection of furazolidone(FZD)in aquaculture is of great importance for food safety and human health.In this study,molecularly imprinted fi lms modifi ed with carboxylated multi-walled carbon nanotube-phosphomolybdic acid composite were used to fabricate an electrochemical sensor for the determination of FZD.The nanocomposites were characterized using infrared spectroscopy,scanning electron microscopy,energy-dispersive X-ray spectroscopy,and X-ray diff raction.The electrochemical characteristics of the modifi ed electrodes were examined using electrochemical impedance spectroscopy,cyclic voltammetry,and diff erential pulse voltammetry.The sensor exhibited exceptional catalytic performance.The calibration curves were acquired in the concentration range of 6 nmol·L^(−1)to 0.6μmol·L^(−1),with a limit of detection of 3.38 nmol·L^(−1).Additionally,the sensor proved successful in recognizing FZD in shrimp samples with satisfactory recoveries and precision.The method provides a strategy to construct a molecularly imprinted electrochemical sensing platform using nanomaterials,which has great promise in the field of food safety.
文摘The wear behavior of multi-walled carbon nano-tubes(MWCNTs)reinforced copper metal matrix composites(MMCs)processed through powder metallurgy(PM)route was focused on and further investigated for varying MWCNT quantity viaexperimental,statistical and artificial neural network(ANN)techniques.Microhardness increases with increment in MWCNTquantity.Wear loss against varying load and sliding distance was analyzed as per L16orthogonal array using a pin-on-disctribometer.Process parameter optimization by Taguchi’s method revealed that wear loss was affected to a greater extent by theintroduction of MWCNT;this wear resistant property of newer composite was further analyzed and confirmed through analysis ofvariance(ANOVA).MWCNT content(76.48%)is the most influencing factor on wear loss followed by applied load(12.18%)andsliding distance(9.91%).ANN model simulations for varying hidden nodes were tried out and the model yielding lower MAE valuewith3-7-1network topology is identified to be reliable.ANN model predictions with R value of99.5%which highly correlated withthe outcomes of ANOVA were successfully employed to investigate individual parameter’s effect on wear loss of Cu?MWCNTMMCs.
文摘The effects of different cation concentrations and types on rheological property and stability of Guar, Xanthan, and Partially Hydrolyzed Polyacrylamide(HPAM) cross-linked gels were analyzed through experiments. Also, a new approach was developed to reduce the negative effects of cation by application of multi-walled carbon nano-tubes(MWCNTs). The presence of cations in cross-linked gel system will reduce the viscosity of gel, the higher the cation concentration is, the lower the viscosity will be. The bivalent cation has a greater viscosity reduction effect on gel than monovalent cation. The stability of cross-linked gels is worse with cations, this situation becomes more serious under higher salinity. MWCNTs were added to HPAM gel, cross-linked by(3-Aminopropyl) triethoxysilane(APTES), they surrounded cations and removed them from polymers and reduced the reaction possibility. This method enhances the viscosity and breakdown pressure of cross-linked gels, improves the stability of HPAM cross-linked gel under different operating conditions, and can be applied to related drilling projects.