Influence of Leachate Recirculation on Landfill Degradation and Biogas Production
1
作者 Kokou N’wuitcha Komlan Déla Donald Aoukou +2 位作者 Yawovi Nougbléga Magolmèèna Banna Xavier Chesneau 《Energy and Power Engineering》 CAS 2023年第1期37-51,共15页
Population growth combined with the rising standard of living of people around the world is the reason for the ever-increasing production of waste which management is costing states a lot of money for its disposal. Am... Population growth combined with the rising standard of living of people around the world is the reason for the ever-increasing production of waste which management is costing states a lot of money for its disposal. Among available waste treatment techniques, landfill is one of the most promoted waste management techniques with the emergence of the bioreactor concept. However, the control of biodegradation parameters in order to accelerate waste stabilization is an important issue. For environmental and economic reasons, the technique of leachate recirculation by injection into the waste is increasingly used to improve the degradation of landfilled waste. The injection of leachate is possible using vertical boreholes, horizontal pipes, infiltration ponds or a combination of these. Indeed, moisture is the main factor in waste degradation and biogas production. The migration of leachate to the bottom of the landfill creates low moisture in the upper areas of the landfill reducing the growth of microbial populations. This results in low or no biogas production. The main objective of the present work is to develop a numerical model of leachate recirculation by injection into the waste to rewet the waste and restart biological activity. The analysis of the results shows that the diffusion of the wet front increases with time and depth. The lateral widening of the wet front is slow in relation to the progression of the wet front towards the bottom of the waste cell. This indicates the predominance of gravity effects over diffusion phenomena. The results reveal that the distributed re-injection is the best mode of leachate recirculation because the moisture distribution on the whole waste mass is totally satisfactory and the biogas generation is more important. Leachate recirculation campaigns should be done periodically to rewet the waste, boost microbial activity and hope for a quicker stabilization of the landfill. 展开更多
关键词 MOISTURE Leachate recirculation BIOGAS Distributed Reinjection LANDFILL
下载PDF
Enhancing treatment efficiency of swine wastewater by effluent recirculation in vertical-flow constructed wetland 被引量:8
2
作者 HE Lian-sheng LIU Hong-liang +1 位作者 XI Bei-dou ZHU Ying-bo 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第2期221-226,共6页
Livestock wastewater has been a major contributor to Chinese cultural eutrophication of surface waters. Constructed wetlands are under study as a best management practice to treat wastewater from dairy and swine opera... Livestock wastewater has been a major contributor to Chinese cultural eutrophication of surface waters. Constructed wetlands are under study as a best management practice to treat wastewater from dairy and swine operations, but the removal efficiency of pollutants is relatively low. Enhancing the treatment efficiency of livestock wastewater by effluent recirculation was investigated in a pilot-scale vertical-flow constructed wetland. The wetland system was composed of downflow and upflow stages, on which narrow-leaf Phragmites communis and common reed Phragraites Typhia are planted, respectively; each stage has a dimension of 4 m^2 (2 m × 2 m). Wastewater from facultative pond was fed into the system intermittently at a flow rate of 0.4 m^3/d. Recirculation rates of 0, 25%, 50%, 100% and 150% were adopted to evaluate the effect of the recirculation rate on pollutants removal. It shows that with effluent recirculation the average removal efficiencies of NH4-N, biological oxygen demand (BOD5) and suspended solids(SS) obviously increase to 61.7%, 81.3%, and 77.1%, respectively, in comparison with the values of 35.6%, 50.2%, and 49.3% without effluent recirculation. But the improvement of TP removal is slight, only from 42.3% to 48.9%. The variations of NH4-N, dissolved oxygen(DO) and oxidation-reduction potential(ORP) of inflow and outflow reveal that the adoption of effluent recirculation is benefi- cial to the formation of oxide environment in wetland. The exponential relationships with excellent correlation coefficients (R2 〉0.93) are found between the removal rates of NH4-N and BOD5 and the recirculation rates. With recirculation the pH value of the outflow decreases as the alkalinity is consumed by gradually enhanced nitrification process. When recirculation rate is kept constant 100%, the ambient temperature appears to affect NH4-N removal, but does not have significant influence on BOD5 removal. 展开更多
关键词 VERTICAL-FLOW constructed wetland swine wastewater effluent recirculation recirculation rate NITRIFICATION
下载PDF
Inlet Recirculation Influence to the Flow Structure of Centrifugal Impeller 被引量:10
3
作者 YANG Ce CHEN Shan +2 位作者 LI Du YANG Changmao WANG Yidi 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2010年第5期647-654,共8页
Inlet recirculation is proved as an effective way for centrifugal compressor surge margin extension,and is successively used in some engineering applications.Unfortunately its working mechanism is still not being well... Inlet recirculation is proved as an effective way for centrifugal compressor surge margin extension,and is successively used in some engineering applications.Unfortunately its working mechanism is still not being well understood,which leads to redesigning of inlet recirculation mostly by experience.Also,most study about inlet recirculation is steady to date.It is necessary to study surge margin extension mechanism about inlet recirculation.To expose the mechanism in detail,steady and unsteady numerical simulations were performed on a centrifugal compressor with and without inlet recirculation.The results showed that,with inlet recirculation,the inlet axial velocity is augmented,relative Mach number around blade tip leading edge area is significantly reduced and so is the flow angle.As the flow angle decreased,the incidence angle reduced which greatly improves the flow field inside the impeller.Moreover,inlet recirculation changes the blade loading around blade tip and restrains the flow separation on the blade suction side at the leading edge area.The unsteady results of static pressure around blade surface,entropy at inlet crossflow section and vorticity distributions at near tip span surface indicated that,at near stall condition,strong fluctuation exists in the vicinity of tip area due to the interaction between tip leakage flow and core flow.By inlet recirculation these strong flow fluctuations are eliminated so the flow stability is greatly enhanced.All these improvements mentioned above are the reason for inlet recirculation delays compressor stall.This research reveals the surge margin extension reason of inlet recirculation from an unsteady flow viewpoint and provides important reference for inlet recirculation structure design. 展开更多
关键词 centrifugal compressor inlet recirculation flow field calculation flow structure UNSTEADY
下载PDF
Landfill leachate production, quality and recirculation treatment in northeast China 被引量:1
4
作者 ZHAO Qing-liang LIU Xue-yan QI Xu-dong LIU Zhi-gang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第4期625-628,共4页
Landfill leachate recirculation treatment process is a promising and economic way in northeast China due to the distinct season variation. In order to study the impact of recirculation on leachate production and its q... Landfill leachate recirculation treatment process is a promising and economic way in northeast China due to the distinct season variation. In order to study the impact of recirculation on leachate production and its quality, two simulated sanitary landfill reactors, one with leachate recirculation and the other without, were placed outdoor in Harbin. The two-year experimental results indicated that leachate production was reduced by 86% with leachate recirculation and less or no facility for leachate treatment required. Recirculation could improve the leachate quality dramatically with lower COD, SS, NF4-N and higher pH level. Recirculation also could enhance waste degradation and stabilization and improve the efficiency of landfill. This study confirmed that leachate recirculation was a very feasible way for on-site landfill leachate treatment in cold areas. 展开更多
关键词 cold area sanitary landfill LEACHATE recirculation solid waste
下载PDF
Performance of the Full-scale Loop Hybrid Reactor Treating Coal Gasification Wastewater under Different Recirculation Modes 被引量:1
5
作者 Qian Zhao Hongjun Han +1 位作者 Fang Fang Wang Bing 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第5期31-37,共7页
This paper aims to investigate the simultaneous removal efficiencies of both COD and nitrogen in a single reactor treating coal gasification wastewater( CGW). A novel loop hybrid reactor was developed and operated und... This paper aims to investigate the simultaneous removal efficiencies of both COD and nitrogen in a single reactor treating coal gasification wastewater( CGW). A novel loop hybrid reactor was developed and operated under different recirculation modes in order to achieve simultaneous removal of refractory compounds and total nitrogen( TN) in a full-scale CGW treatment plant. Mid-ditch recirculation was superior to other operational modes in terms of the NH3-N and TN removal,resulting in a TN removal efficiency of 52. 3%.Although the system achieved equal COD removal rates under different recirculation modes,hydrophobic acid( HPO-A) fraction of effluent dissolved organic matter( DOMef) in mid-ditch recirculation mode accounted for35.7%,compared to the proportions of 59. 2%,45. 3% and 39. 4% for the other modes. The ultraviolet absorbance to dissolved organic carbon ratio test revealed that effluent under mid-ditch recirculation mode contained more non-aromatic hydrophilic components. Furthermore,appropriate recirculation and anoxic / oxic( A/O) partitions were also demonstrated to remove some refractory metabolites( phenols,alkanes,aniline,etc.),which reduced the chromaticity and improved the biodegradability. 展开更多
关键词 coal gasification wastewater refractory COD total nitrogen recirculation mode DOM fractionation
下载PDF
Effects of Flue Gas Internal Recirculation on NOx and SOx Emissions in a Co-Firing Boiler 被引量:2
6
作者 Jun Li Xiaolei Zhang +1 位作者 Weihong Yang Wlodzimierz Blasiak 《International Journal of Clean Coal and Energy》 2013年第2期13-21,共9页
Volumetric combustion has been developed to realize a high substitution ratio of biomass in co-firing boilers, which features an intensive flue gas internal recirculation inside furnace. However, the characteristics o... Volumetric combustion has been developed to realize a high substitution ratio of biomass in co-firing boilers, which features an intensive flue gas internal recirculation inside furnace. However, the characteristics of NOx and SOx emissions in large-scale boilers with volumetric combustion were not fully clear. In this paper, an Aspen Plus model of volumetric combustion system was built up based on a co-firing boiler. In order to characterize the reductions of NOx and SOx, three biomass substitution ratios were involved, namely, 100% biomass, 45% biomass with 55% coal, and 100% coal. The effects of flue gas recirculation ratio, air preheating temperature, oxygen concentration, and fuel types on pollutants emission in the volumetric combustion system were investigated. According to the results, it was concluded the higher substitution ratio of biomass in a co-firing boiler, the lower emissions of NOx and SOx. Moreover, flue gas internal recirculation is an effective pathway for NOx reduction and an increased recirculation ratio resulted in a significant decreasing of NOx emission;however, the SOx increased slightly. The influences of air preheating temperature and O2 concentration on NOx emission were getting weak with increasing of recirculation ratio. When 10% or even higher of flue gas was recycled, it was observed that almost no NOx formed thermodynamically under all studied conditions. Finally, to reach a low emission level of NOx, less energy would be consumed during biomass combustion than coal combustion process for internal recirculation of flue gas. 展开更多
关键词 FLUE Gas INTERNAL recirculation CO-FIRING NOx SOX
下载PDF
EFFECTS OF COOLED EXTERNAL EXHAUST GAS RECIRCULATION ON DIESEL HOMOGENEOUS CHARGE COMPRESSION IGNITION ENGINE 被引量:2
7
作者 SHI Lei CUI Yi DENG Kangyao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第1期21-24,共4页
The effects of cooled external exhaust gas recirculation (EGR) on the combustion and emission performance of diesel fuel homogeneous charge compression ignition (HCCI) are studied. Homogeneous mixture is formed by... The effects of cooled external exhaust gas recirculation (EGR) on the combustion and emission performance of diesel fuel homogeneous charge compression ignition (HCCI) are studied. Homogeneous mixture is formed by injecting fuel in-cylinder in the negative valve overlap (NVO) period. So, the HCCI combustion which has low NOx and smoke emission is achieved. Cooled external EGR can delay the start of combustion effectively, which is very useful for high cetane fuel (diesel) HCCI, because these fuels can easily self-ignition, which makes the start of combustion more early. External EGR can avoid the knock combustion of HCCI at high load which means that the EGR can expand the high load limit. HCCI maintains low smoke emission at various EGR rate and various load compared with conventional diesel engine because there is no fuel-rich area in cylinder. 展开更多
关键词 Homogeneous charge compression ignition (HCC1) Combustion Cooled exhaust gas recirculation (EGR) Emission
下载PDF
Combustion behavior and influence mechanism of CO on iron ore sintering with flue gas recirculation 被引量:9
8
作者 范晓慧 余志元 +2 位作者 甘敏 陈许玲 季志云 《Journal of Central South University》 SCIE EI CAS 2014年第6期2391-2396,共6页
The properties of circulating gas have a significant effect on sintering with flue gas recirculation,and the influence of CO in sintering process was investigated.The results show that the post-combustion of CO conduc... The properties of circulating gas have a significant effect on sintering with flue gas recirculation,and the influence of CO in sintering process was investigated.The results show that the post-combustion of CO conducts in sinter zone when flue gas passes through the sintering bed,which releases much heat and reduces the consumption of solid fuel.The ratio of coke breeze can be reduced from 5% to 4.7% with 2% CO in circulating flue gas.In addition,with the increase of CO content in circulating flue gas,the combustion efficiency of fuel is improved,and the flame front is increased slightly while still matches with the heat transfer front.These are beneficial to increasing the maximum temperature and prolonging the high temperature duration,especially in the upper layer of sintering bed.As a consequence,the productivity,vertical sintering velocity and quality of sinter are improved. 展开更多
关键词 烟气再循环 矿石烧结 CO含量 燃烧行为 机制 垂直烧结速度 固体燃料 循环气体
下载PDF
Process Simulation of a 620 Mw-Natural Gas Combined Cycle Power Plant with Optimum Flue Gas Recirculation 被引量:1
9
作者 Ahmed Badr Al Hashmi Abdel Aziz Abdulla Mohamed Zin Eddine Dadach 《Open Journal of Energy Efficiency》 2018年第2期33-52,共20页
The main objective of this investigation is to obtain an optimum value for the flue gas recirculation ratio in a 620 MW-Natural Gas Combined Cycle (NGCC) power plant with a 100% excess air in order to have a compositi... The main objective of this investigation is to obtain an optimum value for the flue gas recirculation ratio in a 620 MW-Natural Gas Combined Cycle (NGCC) power plant with a 100% excess air in order to have a composition of the exhaust gas suitable for an effective absorption by amine solutions. To reach this goal, the recirculated flue gas is added to the secondary air (dilution air) used for cooling the turbine. The originality of this work is that the optimum value of a Flue Gas Recirculation (FGR) ratio of 0.42 is obtained from the change of the slope related to the effects of flue gas recirculation ratio on the molar percentage of oxygen in the exhaust gas. Compared to the NGCC power plant without flue gas recirculation, the molar percentage of carbon dioxide in the flue gas increases from 5% to 9.2% and the molar percentage of oxygen decreases from 10.9% to 3.5%. Since energy efficiency is the key parameter of energy conversion systems, the impact of the flue gas recirculation on the different energy inputs and outputs and the overall efficiency of the power plant are also investigated. It is found the positive effects of the flue gas recirculation on the electricity produced by the steam turbine generator (STG) are more important than its cooling effects on the power output of the combustion turbine generator (CTG). The flue gas recirculation has no effects on the water pump of the steam cycle and the increase of energy consumed by the compressor of flue gas is compensated by the decrease of energy consumed by the compressor of fresh air. Based on the Low heating value (LHV) of the natural gas, the flue gas recirculation increases the overall efficiency of the power plant by 1.1% from 57.5% from to 58.2%. 展开更多
关键词 Natural GAS Combined Cycle (NGCC) FLUE GAS recirculation Absorption by AMINE CCS
下载PDF
Fundamental study on iron ore sintering new process of flue gas recirculation together with using biochar as fuel 被引量:3
10
作者 甘敏 范晓慧 +3 位作者 姜涛 陈许玲 余志元 季志云 《Journal of Central South University》 SCIE EI CAS 2014年第11期4109-4114,共6页
It is of great significance for cleaner production to substitute bio-energy for fossil fuels in iron ore sintering. However, with the replacement ratio increasing, the consistency of heat front and flame front is brok... It is of great significance for cleaner production to substitute bio-energy for fossil fuels in iron ore sintering. However, with the replacement ratio increasing, the consistency of heat front and flame front is broken, and the thermal utilizing efficiency of fuel is reduced, which results in the decrease of yield and tumble index of sinter. Circulating flue gas to sintering bed as biochar replacing 40% coke, CO in flue gas can be reused so as to increase the thermal utilizing efficiency of fuels, and the consistency of two fronts is recovered for the circulating flue gas containing certain CO2, H2 O and lower O2, which contributes to increasing the maximum temperature, extending the high temperature duration time of sintering bed, and results in improving the output and quality of sinter. In the condition of circulating 40% flue gas, the sintering with biomass fuels is strengthened, and the sintering indexes with biomass fuel replacing 40% coke breeze are comparative to those of using coke breeze completely. 展开更多
关键词 烟气再循环 矿石烧结 化石燃料 生物炭 基础研究 生物质燃料 利用效率
下载PDF
Fuzzy Control of Nitrate Recirculation and External Carbon Addition in A/O Nitrogen Removal Process 被引量:6
11
作者 马勇 彭永臻 +1 位作者 王淑莹 王晓莲 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2005年第2期244-249,共6页
Nitrogen and phosphorous concentrations of effluent water must be taken into account for the design and operation of wastewater treatment plants. In addition, the requirement for effluent quality is becoming strict.Th... Nitrogen and phosphorous concentrations of effluent water must be taken into account for the design and operation of wastewater treatment plants. In addition, the requirement for effluent quality is becoming strict.Therefore, intelligent control approaches are recently required in removing biological nutrient. In this study, fuzzy control has been successfully applied to improve the nitrogen removal. Experimental results showed that a close relationship between nitrate concentration and oxidation-reduction potential (ORP) at the end of anoxic zone was found for anoxic/oxic (A/O) nitrogen removal process treating synthetic wastewater. ORP can be used as online fuzzy control parazneter of nitrate recirculation and external carbon addition. The established fuzzy logic controller that includes two inputs and one output can maintain ORP value at-86 mV and -90 mV by adjusting the nitrate recirculation flow and external carbon dosage respectively to realize the optimal control of nitrogen removal, improving the effluent quality and reducing the operating cost. 展开更多
关键词 脱氮工艺 模糊控制系统 硝酸盐 回收技术 富营养化 环境污染 水处理工艺 厌氧/耗氧处理技术
下载PDF
Coupled simulation of recirculation zonal firebox model and detailed kinetic reactor model in an industrial ethylene cracking furnace 被引量:8
12
作者 Zhou Fang Tong Qiu Weiguo Zhou 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第8期1091-1100,共10页
A coupled system simulating both firebox and reactor is established to study the naphtha pyrolysis in an industrial tubular furnace.The firebox model is based on zone method including combustion,radiation,and convecti... A coupled system simulating both firebox and reactor is established to study the naphtha pyrolysis in an industrial tubular furnace.The firebox model is based on zone method including combustion,radiation,and convection to simulate heat transfer in the furnace.A two-dimensional recirculation model is proposed to estimate the flow field in furnace.The reactor model integrates the feedstock reconstruction model,an auto-generator of detail kinetic schemes,and the reactor simulation model to simulate the reaction process in the tubular coil.The coupled simulation result is compared with industrial process and shows agreement within short computation time. 展开更多
关键词 乙烯裂解炉 耦合模拟 反应模型 循环模型 工业过程 燃烧室 动力学 反应器模型
下载PDF
Automation in detection of recirculation in a booster fan ventilation network 被引量:1
13
作者 Mahesh Shriwas Felipe Calizaya 《International Journal of Mining Science and Technology》 EI CSCD 2018年第3期513-517,共5页
Recirculation is prohibited in many coal mining countries because of the fear that the re-use of return air would allow the build-up of air contaminants at the workings. The incorrect design and location of a booster ... Recirculation is prohibited in many coal mining countries because of the fear that the re-use of return air would allow the build-up of air contaminants at the workings. The incorrect design and location of a booster fan in any ventilation network can create unsafe condition due to recirculation. The current approach to investigating recirculation using simulation software requires manual effort which becomes tedious in a complex and a large network. An algorithm-based C++ program was designed to detect the recirculation in a booster fan ventilation networks. This program needed an input file prepared from output file generated by any ventilation simulator. This program created an output file for recirculation. This program demonstrated the strong capability to detect the recirculation in a sample network and a coal mine ventilation network. The outcomes of this program were documented in this paper. 展开更多
关键词 通风网络 模拟软件 扇子 自动化 C++程序 建筑群 空气 设计
下载PDF
Effect of exhaust gas recirculation and intake pre-heating on performance and emission characteristics of dual fuel engines at part loads 被引量:6
14
作者 A.Paykani R.Khoshbakhti Saray +1 位作者 M.T.Shervani-Tabar A.Mohammadi-Kousha 《Journal of Central South University》 SCIE EI CAS 2012年第5期1346-1352,共7页
Achieving simultaneous reduction of NOx,CO and unburned hydrocarbon(UHC) emissions without compromising engine performance at part loads is the current focus of dual fuel engine research.The present work focuses on an... Achieving simultaneous reduction of NOx,CO and unburned hydrocarbon(UHC) emissions without compromising engine performance at part loads is the current focus of dual fuel engine research.The present work focuses on an experimental investigation conducted on a dual fuel(diesel-natural gas) engine to examine the simultaneous effect of inlet air pre-heating and exhaust gas recirculation(EGR) ratio on performance and emission characteristics at part loads.The use of EGR at high levels seems to be unable to improve the engine performance at part loads.However,it is shown that EGR combined with pre-heating of inlet air can slightly increase thermal efficiency,resulting in reduced levels of both unburned hydrocarbon and NOx emissions.CO and UHC emissions are reduced by 24% and 31%,respectively,The NOx emissions decrease by 21% because of the lower combustion temperature due to the much inert gas brought by EGR and decreased oxygen concentration in the cylinder. 展开更多
关键词 双燃料发动机 发动机性能 废气再循环 排放特性 进气预热 部分负载 氮氧化物排放量 部分负荷性能
下载PDF
Research and Application of Airflow Recirculation System in Working Faces with Leaking Airflow
15
作者 朱红青 杜木民 赵伟芝 《International Journal of Mining Science and Technology》 SCIE EI 1999年第2期176-178,共3页
In order to develop the technology of the controlled recircuIation of airflow in the world, some formulas about the airflow recirculation system in the working face with leaking airflow are deduced,which reduces the e... In order to develop the technology of the controlled recircuIation of airflow in the world, some formulas about the airflow recirculation system in the working face with leaking airflow are deduced,which reduces the error between calculating and real values. on the base of the application of the formulas mentioned above, the problem about lack of airflow in the working face 2712 was solved successfully in Xiandewang Coal Mine. 展开更多
关键词 CONTROLLED recirculation of AIRFLOW leaking SOURCE of AIRFLOW working FACE
下载PDF
Investigation over the recirculation influence on the combustion of micro organic dust particles
16
作者 M. BIDABADI A. FANAEE A. RAHBARI 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2010年第6期685-696,共12页
This paper investigates the role of recircnlation and non-unity Lewis number on the combustion of organic dust particles. Since recirculation effect is more noticeable in micro-combustors, it is necessary to propose a... This paper investigates the role of recircnlation and non-unity Lewis number on the combustion of organic dust particles. Since recirculation effect is more noticeable in micro-combustors, it is necessary to propose a modeling approach of this phenomenon to better simulate the performance of micro-combustors. In this research, in order to model the combustion of organic dust particles, it is assumed that the dust particles va- porize first to yield a known chemical structure which is oxidized in the gas phase, and the chemical structure of this gaseous fuel is assumed methane. To study the flame structure and solve the governing equations, it is considered that the flame structure consists of three zones titled the preheat-vaporization zone, the narrow reaction zone and finally the post flame zone. The recirculation phenomenon is evaluated by entering the exhausted heat from the post flame zone into the preheat zone. The solution is based on the follow- ing approach. First, the governing equations in each zone are nondimensionalized. Then the needed boundary and matching conditions are applied in each zone. After that, these equations and the required boundary and matching conditions are simultaneously solved with the analytical model. Consequently, the remarkable effects of recirculation and non- unity Lewis number on the combustion characteristics of the organic dust particles such as burning velocity and temperature profiles for different particle radii are obtained. The results show reasonable agreement with published experimental data. 展开更多
关键词 recirculation non-unity Lewis number organic dust particles flame temperature burning velocity
下载PDF
Effects of Biogas Slurry Recirculation on Anaerobic Digestion Performance of Maize Straw Silage
17
作者 Xinhe LIU Nan LI +4 位作者 Mengya YANG Benyue ZHANG Guangbo XU Renzhe PIAO Hongyan ZHAO 《Asian Agricultural Research》 2018年第12期49-51,54,共4页
In order to investigate the effects of slurry recirculation technology on anaerobic digestion performance of maize straw silage,maize straw silage was fermented with recirculated biogas slurry,and the gas production,p... In order to investigate the effects of slurry recirculation technology on anaerobic digestion performance of maize straw silage,maize straw silage was fermented with recirculated biogas slurry,and the gas production,p H value,methane content,volatile organic acids( VFAs)contents,chemical oxygen demand( COD) removal rate and other indicators were studied. The results showed that the fermentation time was positively correlated with daily gas production,methane content,cumulative gas production,VFAs and COD removal rate. Although the p H value fluctuated,it was still in the normal reaction range. The daily gas production was about 1. 26 L. The acetic acid content increased first,then decreased,then increased,and finally stabilized. The biogas slurry recirculation technology saves water resources by 40 m L/d without affecting the normal gas production of anaerobic fermentation,and reduces the consumption of environmental resources. It has important development significance for the sustainable use of biomass resources. 展开更多
关键词 BIOGAS slurry recirculation Maize STRAW SILAGE Anaerobic DIGESTION PERFORMANCE Biomass resources
下载PDF
The Experimental Investigation of Recirculation of Air-Cooled System for a Large Power Plant
18
作者 Wanli Zhao Qiyue Wang Peiqing Liu 《Energy and Power Engineering》 2010年第4期291-297,共7页
The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV... The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV experiments are carried out and recirculation ratio of each condition is calculated. Results show that the thermal flow field of the cooling tower has great influence on the recirculation under the cooling tower. Ameliorating the thermal flow field of the cooling tower can reduce the recirculation under the cooling tower and improve the efficiency of air-cooled condenser also. 展开更多
关键词 DIRECT Air-Cooled CONDENSER Thermal Flow Field recirculation PIV EXPERIMENT Power PLANT
下载PDF
Reverse Osmosis Performance in MBR-RO Process with Recirculation of RO Concentrate to MBR for Water Reclamation
19
作者 Hui Deng Matthieu Jacob +2 位作者 Manon Montaner Jean-Stéphane Pic Christelle Guigui 《Journal of Water Resource and Protection》 2020年第9期800-824,共25页
An integrated membrane system, membrane bioreactor-reverse osmosis (MBR-RO), has become highly efficient in producing high-quality water for municipal wastewater reclamation. However, disposal of a highly concentrated... An integrated membrane system, membrane bioreactor-reverse osmosis (MBR-RO), has become highly efficient in producing high-quality water for municipal wastewater reclamation. However, disposal of a highly concentrated waste stream (RO concentrate or RO retentate) generated in this combination is an important issue. This work investigated RO behaviour in an integrated pilot scale MBR-RO system for municipal wastewater reuse with the continuous recycling of RO retentate to the MBR influent. RO membrane retention and the fouling propensity were studied. RO concentrate, produced by the RO process at a fixed concentration factor (CF) of 3, was recycled continuously to the MBR, leading to water recovery of the entire process around 92%. Osmotic pressure model, saturation index method, high performance liquid chromatography equipped with size exclusion column (HPLC-SEC) and specific filtration test were used to analyse the fouling potential of the RO membrane. The results obtained showed that even though RO concentrate recycling changed remarkably, the compositions of both MBR permeate and RO concentrate, the quality of RO permeate remained almost constant in terms of organic matters, conductivity, and ionic salts. However, these high concentrations of organic or inorganic substances in RO concentrate were major factors leading to the RO membrane fouling. Before RO concentrate recycling, a decline of approximately 30% of the initial RO permeate flux was observed in the period when the CF was increasing to 3, mainly due to the osmotic pressure effect of retained ions and the deposits of organic matters at the RO membrane surface. After RO concentrate addition to the MBR, due to the continuous accumulation of ionic salts on the RO membrane surface, a gradual reduction in RO permeate flux (additional 19%) was also mainly attributed to the osmotic pressure effect of the retained ions. These observations showed that the continuous addition of RO concentrate to the MBR was successful in a combined MBR and RO process in terms of the excellent quality of RO permeate. 展开更多
关键词 High-Quality Water Reuse MBR-RO Combination RO Concentrate recirculation RO Fouling
下载PDF
Sexual Reversal with 17α-Methyltestosterone in Oreochromis sp.:Comparison between Recirculation Aquaculture System(RAS)and Biofloc Technology(BFT)
20
作者 Carlos Arturo David-Ruales Eliana Marcela Betancur-Gonzalez Ruben Dario Valbuena-Villareal 《Journal of Agricultural Science and Technology(A)》 2019年第2期131-139,共9页
Precocity in tilapia implies the use of several methods of obtaining monosex seed;the most common tends to use masculinizing hormone 17α-methyltestosterone(17αMT),with variable results.Thus the objective of this stu... Precocity in tilapia implies the use of several methods of obtaining monosex seed;the most common tends to use masculinizing hormone 17α-methyltestosterone(17αMT),with variable results.Thus the objective of this study was to compare the efficiency of the sexual reversion process using 17αMT,in a recirculation system and in biofloc.In a totally randomized design,three tanks for recirculation(T-RAS)and three tanks for biofloc(T-BIO)with a capacity of 200 L effective volume were taken and filled with 1,056 larvae of Oreochromis sp.,without reversing and with an initial weight of 0.02 g and an initial total length of 1.4 mm.The study was carried out during 65 d,the fish were fed(10%biomass,adjusted every 15 d)by a commercial diet at 45%of crude protein that included 17αMT(60 mg/kg).Water quality,microbiology,zootechnical and gonadal analysis were monitored.Consequently the water quality results showed that just dissolved oxygen(DO),temperature(T-°C)and alkalinity did not show significant differences.Additionally,in the productive parameters there were significant differences in the final length,the gain in length and in K which were better in T-BIO.The microbiological ones did not present significant differences between the treatments.Lastly,the percentage of reversion was significantly better in T-RAS.Then,this study suggests that settleable solids concentrations above 35 cm decrease the efficiency of the sexual reversion for this species. 展开更多
关键词 OREOCHROMIS sp. biofloc recirculation AQUACULTURE system 17α-methyltestosterone