Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have ...Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have large gas concentration fluctuation,especially when the gas concentration is high.In this paper,we demonstrate an extension of the dynamic range of ICOS by using a detuned laser combined with an off-axis integrating cavity.With this,we improve the upper limit of the dynamic detection range from 0.1%(1000 ppm) to 20% of the gas concentration.This method provides a way of using ICOS in the applications with unpredictable gas concentrations such as gas leak detection,ocean acidification,carbon sequestration,etc.展开更多
Continuous-wave cavity ring-down spectroscopy(CW-CRDS)is an important technical means to monitor greenhouse gases in atmospheric environment.In this paper,a CW-CRDS system is built to meet the needs of atmospheric met...Continuous-wave cavity ring-down spectroscopy(CW-CRDS)is an important technical means to monitor greenhouse gases in atmospheric environment.In this paper,a CW-CRDS system is built to meet the needs of atmospheric methane monitoring.The problem of mode matching is explained from the perspective of transverse mode and longitudinal mode,and the influence of laser injection efficiency on measurement precision is further analyzed.The results of cavity ring-down time measurement show that the measurement precision is higher when the laser is coupled with the fundamental mode.In the experiment,DFB laser is used to calibrate the system with standard methane concentration,and the measurement residual is less than±4×10^(-4)μs^(-1).The methane concentration in the air is monitored in real time for two days.The results show the consistency of the concentration changes over the two days,which further demonstrates the reliability of the system for the measurement of trace methane.By analyzing the influence of mode matching,it not only assists the adjustment of the optical path,but also further improves the sensitivity of the system measurement.展开更多
Near-infrared continuous wave cavity ring-down spectroscopy was applied to mea- sure the OH radicals in dielectric barrier discharge plasmas, which play an important role in combustion systems, atmospheric chemistry a...Near-infrared continuous wave cavity ring-down spectroscopy was applied to mea- sure the OH radicals in dielectric barrier discharge plasmas, which play an important role in combustion systems, atmospheric chemistry and the removal of air pollutants by non-thermal plasmas. The P-branches of OH X2YIi (vI : 2 +-- it 0) bands were used for number density measurements. The OH number density and plasma temperature were determined for different applied voltages, gas pressures and concentrations of both oxygen and water. The temporal evolu- tion of the OH number density was obtained by using the "time window" method, which was used to extract individual ring-down times at different times in a half period of the sine wave applied voltage in dielectric barrier discharge plasmas.展开更多
NO3 and N2O5 are important participants in nocturnal atmospheric chemical processes,and their concentrations are of great significance in the study of the mechanism of nocturnal atmospheric chemical reactions.A two-ch...NO3 and N2O5 are important participants in nocturnal atmospheric chemical processes,and their concentrations are of great significance in the study of the mechanism of nocturnal atmospheric chemical reactions.A two-channel diode laser based cavity ring-down spectroscopy(CRDS)instrument was developed to monitor the concentrations of NO3 and N2O5 in the atmosphere.The effective absorption length ratio and the total loss coefficient of the instrument were calibrated using laboratory standard samples.The effective absorption cross section of NO3 at 662 nm was derived.A detection sensitivity of 1.1 pptv NO3 in air was obtained at a time resolution of 1 s.N2O5 was converted to NO3 and detected online in the second CRDS channel.The instrument was used to monitor the concentrations of NO3 and N2O5 in the atmosphere of winter in Hefei in real time.By comparing the concentration changes of pollutants such as nitrogen oxides,ozone,PM2:5 in a rapid air cleaning process,the factors affecting the concentrations of NO3 and N2O5 in the atmosphere were discussed.展开更多
Fast and accurate quantitative detection of ^(14)CO_(2) has impor-tant applications in many elds.The optical detection method based on the sensitive cavity ring-down spectroscopy technol-ogy has great potential.But cu...Fast and accurate quantitative detection of ^(14)CO_(2) has impor-tant applications in many elds.The optical detection method based on the sensitive cavity ring-down spectroscopy technol-ogy has great potential.But currently it has diffculties of insuffcient sensitivity and susceptibility to absorption of other isotopes/impurity molecules.We propose a stepped double-resonance spectroscopy method to excite ^(14)CO_(2) molecules to an intermediate vibrationally excited state,and use cavity ring-down spectroscopy to probe them.The two-photon process signi cantly improves the selectivity of detection.We derive the quantitative measurement capability of double-resonance absorption spectroscopy.The simulation results show that the double-resonance spectroscopy measurement is Doppler-free,thereby reducing the e ect of other molecular absorption.It is expected that this method can achieve high-selectivity detection of ^(14)CO_(2) at the sub-ppt level.展开更多
Frequency shifts of the acetylene saturated absorption lines at 1.5μm with temperature, gas pressure and laser power have been investigated in detail. The second-order Doppler effect, the recoil effect, the Zeeman ef...Frequency shifts of the acetylene saturated absorption lines at 1.5μm with temperature, gas pressure and laser power have been investigated in detail. The second-order Doppler effect, the recoil effect, the Zeeman effect, the pressure shift and the power shift are taken into consideration. The magnitudes of those shifts caused by various effects are evaluated. In order to reproduce the stability of 5.7 × 10^-14 obtained by Edwards, all necessary conditions are given. The results show that when there is a larger external magnetic field, the Zeeman shift could not be neglected, so that the shield should be employed. And the design of a long cavity is advantageous to reduce the influence of the second-order Doppler effect. The results also show that at least 4-2.5℃ temperature control for cavity can effectively prevent several effects and improve the frequency stability.展开更多
Direct-comb spectroscopy techniques uses optical frequency combs(OFCs)as spectroscopic light source.They deliver high sensitivity,high frequency resolution and precision in a broad spectral range.Due to these features...Direct-comb spectroscopy techniques uses optical frequency combs(OFCs)as spectroscopic light source.They deliver high sensitivity,high frequency resolution and precision in a broad spectral range.Due to these features,the field has burgeoned in recent years.In this work we constructed an OFC-based cavity-enhanced Fourier-transform spectrometer in the nearinfrared region and used it for a line-shape study of rovibrational transitions of CO perturbed by Ar.The highly sensitive measurements spanned the wavenumber range from 6270 cm^-1 to 6410 cm^-1,which covered both P and R branch of the second overtone band of CO.The spectrometer delivers high-resolution surpassing the Fourier-transform resolution limit determined by interferogram length,successfully removing ringing and broadening effects caused by instrumental line shape function.The instrumental-line-shape-free method and high signal-to-noise ratio in the measurement allowed us to observe collisional effects beyond those described by the Voigt profile.We retrieved collisional line-shape parameters by fitting the speed-dependent Voigt profile and found good agreement with the values given by precise cavity ring-down spectroscopy measurements that used a continuous-wave laser referenced to a stabilized OFC.The results demonstrate that OFC-based cavity-enhanced Fouriertransform spectroscopy is a strong tool for accurate line-shape studies that will be crucial for future spectral databases.展开更多
基金Project supported by the National Key Research and Development Program of China(Grant No.2017YFC0209700)the National Natural Science Foundation of China(Grant No.41730103)。
文摘Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have large gas concentration fluctuation,especially when the gas concentration is high.In this paper,we demonstrate an extension of the dynamic range of ICOS by using a detuned laser combined with an off-axis integrating cavity.With this,we improve the upper limit of the dynamic detection range from 0.1%(1000 ppm) to 20% of the gas concentration.This method provides a way of using ICOS in the applications with unpredictable gas concentrations such as gas leak detection,ocean acidification,carbon sequestration,etc.
基金This research is financial supported by the Natural National Science Foundation of China(Grant Nos.11874364,41877311,and 42005107)the National Key Research and Development Program of China(Grant No.2017YFC0805004)the CAS&Bengbu Technology Transfer Project(Grant No.ZKBB202102).
文摘Continuous-wave cavity ring-down spectroscopy(CW-CRDS)is an important technical means to monitor greenhouse gases in atmospheric environment.In this paper,a CW-CRDS system is built to meet the needs of atmospheric methane monitoring.The problem of mode matching is explained from the perspective of transverse mode and longitudinal mode,and the influence of laser injection efficiency on measurement precision is further analyzed.The results of cavity ring-down time measurement show that the measurement precision is higher when the laser is coupled with the fundamental mode.In the experiment,DFB laser is used to calibrate the system with standard methane concentration,and the measurement residual is less than±4×10^(-4)μs^(-1).The methane concentration in the air is monitored in real time for two days.The results show the consistency of the concentration changes over the two days,which further demonstrates the reliability of the system for the measurement of trace methane.By analyzing the influence of mode matching,it not only assists the adjustment of the optical path,but also further improves the sensitivity of the system measurement.
基金supported by National Natural Science Foundation of China (Nos.10475015, 10975029)
文摘Near-infrared continuous wave cavity ring-down spectroscopy was applied to mea- sure the OH radicals in dielectric barrier discharge plasmas, which play an important role in combustion systems, atmospheric chemistry and the removal of air pollutants by non-thermal plasmas. The P-branches of OH X2YIi (vI : 2 +-- it 0) bands were used for number density measurements. The OH number density and plasma temperature were determined for different applied voltages, gas pressures and concentrations of both oxygen and water. The temporal evolu- tion of the OH number density was obtained by using the "time window" method, which was used to extract individual ring-down times at different times in a half period of the sine wave applied voltage in dielectric barrier discharge plasmas.
基金Hao Wu,Jian Chen,An-wen Liu,and Shui-ming Hu acknowledge the supports from the Ministry of Science and Technology of China(No.2013BAK12B00)the National Natural Science Foundation of China(No.21427804).
文摘NO3 and N2O5 are important participants in nocturnal atmospheric chemical processes,and their concentrations are of great significance in the study of the mechanism of nocturnal atmospheric chemical reactions.A two-channel diode laser based cavity ring-down spectroscopy(CRDS)instrument was developed to monitor the concentrations of NO3 and N2O5 in the atmosphere.The effective absorption length ratio and the total loss coefficient of the instrument were calibrated using laboratory standard samples.The effective absorption cross section of NO3 at 662 nm was derived.A detection sensitivity of 1.1 pptv NO3 in air was obtained at a time resolution of 1 s.N2O5 was converted to NO3 and detected online in the second CRDS channel.The instrument was used to monitor the concentrations of NO3 and N2O5 in the atmosphere of winter in Hefei in real time.By comparing the concentration changes of pollutants such as nitrogen oxides,ozone,PM2:5 in a rapid air cleaning process,the factors affecting the concentrations of NO3 and N2O5 in the atmosphere were discussed.
基金This work was jointly supported by the National Natural Science Foundation of China(No.21688102 and No.11974328)the Chinese Academy of Sci-ences(XDB21020100 and XDC07010000)An-hui Initiative in Quantum Information Technologies(AHY110000).
文摘Fast and accurate quantitative detection of ^(14)CO_(2) has impor-tant applications in many elds.The optical detection method based on the sensitive cavity ring-down spectroscopy technol-ogy has great potential.But currently it has diffculties of insuffcient sensitivity and susceptibility to absorption of other isotopes/impurity molecules.We propose a stepped double-resonance spectroscopy method to excite ^(14)CO_(2) molecules to an intermediate vibrationally excited state,and use cavity ring-down spectroscopy to probe them.The two-photon process signi cantly improves the selectivity of detection.We derive the quantitative measurement capability of double-resonance absorption spectroscopy.The simulation results show that the double-resonance spectroscopy measurement is Doppler-free,thereby reducing the e ect of other molecular absorption.It is expected that this method can achieve high-selectivity detection of ^(14)CO_(2) at the sub-ppt level.
基金Project supported by the Provincial Natural Science Funds of Shanxi Province, China (Grant No 20041037)the Industrial R&D Programme of Shanxi Province, China (Grant No 2006031118-04)
文摘Frequency shifts of the acetylene saturated absorption lines at 1.5μm with temperature, gas pressure and laser power have been investigated in detail. The second-order Doppler effect, the recoil effect, the Zeeman effect, the pressure shift and the power shift are taken into consideration. The magnitudes of those shifts caused by various effects are evaluated. In order to reproduce the stability of 5.7 × 10^-14 obtained by Edwards, all necessary conditions are given. The results show that when there is a larger external magnetic field, the Zeeman shift could not be neglected, so that the shield should be employed. And the design of a long cavity is advantageous to reduce the influence of the second-order Doppler effect. The results also show that at least 4-2.5℃ temperature control for cavity can effectively prevent several effects and improve the frequency stability.
文摘Direct-comb spectroscopy techniques uses optical frequency combs(OFCs)as spectroscopic light source.They deliver high sensitivity,high frequency resolution and precision in a broad spectral range.Due to these features,the field has burgeoned in recent years.In this work we constructed an OFC-based cavity-enhanced Fourier-transform spectrometer in the nearinfrared region and used it for a line-shape study of rovibrational transitions of CO perturbed by Ar.The highly sensitive measurements spanned the wavenumber range from 6270 cm^-1 to 6410 cm^-1,which covered both P and R branch of the second overtone band of CO.The spectrometer delivers high-resolution surpassing the Fourier-transform resolution limit determined by interferogram length,successfully removing ringing and broadening effects caused by instrumental line shape function.The instrumental-line-shape-free method and high signal-to-noise ratio in the measurement allowed us to observe collisional effects beyond those described by the Voigt profile.We retrieved collisional line-shape parameters by fitting the speed-dependent Voigt profile and found good agreement with the values given by precise cavity ring-down spectroscopy measurements that used a continuous-wave laser referenced to a stabilized OFC.The results demonstrate that OFC-based cavity-enhanced Fouriertransform spectroscopy is a strong tool for accurate line-shape studies that will be crucial for future spectral databases.
基金jointly supported by the National Natural Science Foundation of China(No.22273093,No.41905018,No.21903080)the Ministry of Science and Technology of China(No.2022YFF0606500)。