This work investigates the performance of combined hybrid high concentrated photovoltaic/thermal collector (HCPV/T) in Kuwait harsh climate. The proposed system consists of triple junction solar cells (InGaP/InGaAs/Ge...This work investigates the performance of combined hybrid high concentrated photovoltaic/thermal collector (HCPV/T) in Kuwait harsh climate. The proposed system consists of triple junction solar cells (InGaP/InGaAs/Ge) attached to heat source to discharge thermal energy to cooling media. Published HCPV/T models do not consider the effect of shunt resistance which greatly affects the system performance. So, a single diode model employing five parameters including the effect of shunt resistance is adapted to analyze the proposed system. To analyze the thermal performance of the proposed system, a two-dimensional thermal model based on the technique of finite difference is introduced to determine the efficiency of the hybrid HCPV/T system. The present developed subroutines are integrated with other involved codes in TRNSYS software to calculate HCPV/T system efficiency. Electrical and thermal as well as the whole system efficiency at different weather circumstances are evaluated and assessed. The effect of different weather conditions, cell temperature, concentration ratio and the temperatures of the coolant fluid on system performance are studied. Current results indicate that the model of single diode is a reliable one rather than using the two-diode complex model. Compared to measurements provided by high concentrated PV manufacturer, the current results revealed a total root mean square error of approximately 1.94%. Present predictions show that PV cell temperature has logarithmic increase with the rise in concentration ratio but with low values till concentration ratio of 400 suns after that the rise is faster at higher concentration values up to 1500 suns. Results also revealed that hybrid HCPV/T system works effectively specially in severe hot climate where thermal efficiency increases with high surrounding temperature for higher values of concentration ratio. In addition, an increase of approximately 15% in thermal efficiency and 10% in total efficiency can be achieved by utilizing active cooling device in HCPV/T system.展开更多
Nowadays Quantum Cellular Automata (QCA) as the leading technology in design of microelectronic systems has been raised. With respect to high velocity and density in low power and also simple concepts, this technology...Nowadays Quantum Cellular Automata (QCA) as the leading technology in design of microelectronic systems has been raised. With respect to high velocity and density in low power and also simple concepts, this technology is a viable alternative to CMOS technology. In collector design, the primary component of each processor is very important. Due to the small elements in this technology, failure rate in manufacturing process technology is very high. In the other hand, the simulation shows that the intersection point of two wires is one of the critical points in QCA circuits. This means that defects in the manufacturing process around these points can cause malfunction in the circuit performance. In this paper, a collector in cross sections of wire in his new method used higher reliability against defects during manufacturing has been developed. QCA Designer software is used to simulate the case study system.展开更多
文摘This work investigates the performance of combined hybrid high concentrated photovoltaic/thermal collector (HCPV/T) in Kuwait harsh climate. The proposed system consists of triple junction solar cells (InGaP/InGaAs/Ge) attached to heat source to discharge thermal energy to cooling media. Published HCPV/T models do not consider the effect of shunt resistance which greatly affects the system performance. So, a single diode model employing five parameters including the effect of shunt resistance is adapted to analyze the proposed system. To analyze the thermal performance of the proposed system, a two-dimensional thermal model based on the technique of finite difference is introduced to determine the efficiency of the hybrid HCPV/T system. The present developed subroutines are integrated with other involved codes in TRNSYS software to calculate HCPV/T system efficiency. Electrical and thermal as well as the whole system efficiency at different weather circumstances are evaluated and assessed. The effect of different weather conditions, cell temperature, concentration ratio and the temperatures of the coolant fluid on system performance are studied. Current results indicate that the model of single diode is a reliable one rather than using the two-diode complex model. Compared to measurements provided by high concentrated PV manufacturer, the current results revealed a total root mean square error of approximately 1.94%. Present predictions show that PV cell temperature has logarithmic increase with the rise in concentration ratio but with low values till concentration ratio of 400 suns after that the rise is faster at higher concentration values up to 1500 suns. Results also revealed that hybrid HCPV/T system works effectively specially in severe hot climate where thermal efficiency increases with high surrounding temperature for higher values of concentration ratio. In addition, an increase of approximately 15% in thermal efficiency and 10% in total efficiency can be achieved by utilizing active cooling device in HCPV/T system.
文摘Nowadays Quantum Cellular Automata (QCA) as the leading technology in design of microelectronic systems has been raised. With respect to high velocity and density in low power and also simple concepts, this technology is a viable alternative to CMOS technology. In collector design, the primary component of each processor is very important. Due to the small elements in this technology, failure rate in manufacturing process technology is very high. In the other hand, the simulation shows that the intersection point of two wires is one of the critical points in QCA circuits. This means that defects in the manufacturing process around these points can cause malfunction in the circuit performance. In this paper, a collector in cross sections of wire in his new method used higher reliability against defects during manufacturing has been developed. QCA Designer software is used to simulate the case study system.