Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter 被引量:9
1
作者 Hasan Ali Bayhan Seray Aslan Bayhan Iz.zet Can 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期302-308,共7页
AIM:To compare the RTVue spectral optical coherence tomography(SD-OCT),Sirius Scheimpflug-Placido topographer,Lenstar optical low coherence reflectometry(OLCR)and ultrasound pachymetry(USP)devices in terms of their ag... AIM:To compare the RTVue spectral optical coherence tomography(SD-OCT),Sirius Scheimpflug-Placido topographer,Lenstar optical low coherence reflectometry(OLCR)and ultrasound pachymetry(USP)devices in terms of their agreement and repeatability of measuring central corneal thickness(CCT).METHODS:In this prospective study,50 eyes of 50patients were included.Three repeated measures were obtained using SD-OCT,Scheimpflug-Placido topographer and USP and five measurements were determined with the OLCR.Bland-Altman plots were used to assess agreement among the instruments,and 95%limits of agreement(LoA)for each comparison were calculated.Intra-examiner repeatability was assessed using intraclass correlation coefficients(ICCs).RESULTS:The mean CCT by SD-OCT,ScheimpflugPlacido topographer,OLCR,and USP were 525.90±34.08μm,525.92±34.10μm,530.30±35.62μm,and543.50±37.11μm respectively.All 4 modalities of CCT measurements correlated closely with each other,with Pearson correlation coefficients ranging from 0.977 to0.995.The mean differences(and upper/lower LoA)for CCT measurements were-0.05±6.77μm(13.3/-13.3)between SD-OCT and Scheimpflug-Placido topographer,4.38±3.79μm(11.8/-3.1)between OLCR and SD-OCT,4.38±6.03μm(16.2/-7.5)between OLCR and ScheimpflugPlacido topographer,13.20±6.46μm(25.9/0.5)between USP and OLCR,17.59±6.76μm(30.8/4.3)between USP and SD-OCT,and 17.58±8.13μm(33.5/1.6)between USP and Scheimpflug-Placido topographer.Intra-examiner repeatability was excellent for all devices with ICCs】0.98.CONCLUSION:For most practical purposes,CCT measurements with the RTVue,Sirius and Lenstar can be used interchangeably.Although highly correlated,CCTmeasurement differences between USP and these 3optical instruments can be significant depending on the clinical situation. 展开更多
关键词 central corneal thickness optical low coherence reflectometry spectral optical coherence tomography Scheimpflug-Placido topographer
下载PDF
Distribution of central corneal thickness and intraocular pressure in emmetropic eyes of healthy children of Palestine: a representative cross-sectional study 被引量:3
2
作者 Hamed Tm Alkhodari 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第3期496-503,共8页
AIM: To determine the distributions of central corneal thickness(CCT) and intraocular pressure(IOP) in emmetropic eyes of healthy children of Palestine.METHODS: This representative cross sectional study included a tot... AIM: To determine the distributions of central corneal thickness(CCT) and intraocular pressure(IOP) in emmetropic eyes of healthy children of Palestine.METHODS: This representative cross sectional study included a total of 1156 eyes from 578 healthy school children aged 7-15 y. Inclusion criteria included emmetropia, no previous history of ocular or systemic diseases, no previous history of contact lens use, and the availability of both eyes. CCT and IOP were measured using ultrasound pachymeter and Goldmann applanation tonometer, respectively. The relationship of the results with age and gender was investigated.RESULTS: The mean age of school children was 11.13±2.8 y. Mean CCT was 542.2±37.4 and 544.3±39.2 μm for right and left eyes, respectively. Mean IOP was 12.5±2.2 and 12.3±2.2 mm Hg for right and left eyes, respectively. A positive correlation was observed between CCT and IOP of the right eye(P<0.001, R=0.358) and CCT and IOP of the left eye(P<0.001, R=0.324). No significant differences were observed in CCT and IOP due to age or gender(P>0.05). There were significant differences in mean CCT and IOP between right and left eyes(P=0.004, P=0.001, respectively).CONCLUSION: A population profile of CCT and IOP is established in Palestinian children for the first time. Mean CCT is comparable to some studies but differ from others. Mean IOP is considerably lower than that of majority children of other ethnic groups. Intereye difference of more than 36 μm in CCT, and 5 mm Hg in IOP should prompt evaluation for potential ocular disorders. 展开更多
关键词 central corneal thickness INTRAOCULAR pressure intereye asymmetry GOLDMANN applanation TONOMETER ultrasound pachymeter
下载PDF
Changes of corneal central thickness of aphakia following congenital cataract surgery under the first six months of life 被引量:3
3
作者 Wei Xiao Xiao-Fang Liang and Jia-Jun Sun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第1期78-80,共3页
AIM: To observe the central corneal thickness (CCT) changes in infants and young children who had been undergone bilateral congenital cataract surgery, and to compare the changes with normal control group which was se... AIM: To observe the central corneal thickness (CCT) changes in infants and young children who had been undergone bilateral congenital cataract surgery, and to compare the changes with normal control group which was selected from healthy population. METHODS: A cross section case-control study contained 28 cases (56 eyes) of bilateral aphakia (aphakic group) due to congenital cataract surgery combining with posterior continuous curvilinear capsulorhexis and with anterior vitrectomy during 2-6 months after birth. Fourteen children (28 eyes) of age-sex matched with the aphalic group were selected as normal control group. CCT and intraocular pressure (TOP) were measured postoperatively and the results were compared between groups. RESULTS: The mean CCT was 653.5 +/- 82.4 mu m in the aphakic group and 579.6 +/- 39.2 mu m in the control group, with a significant difference (P=0.000). The mean value of TOP in aphakic group (22.0 +/- 1.6mmHg) was greater than that of control group (16.9 +/- 2.1mmHg), P=0.023. There was a negative correlation between age and CCT in normal control group (r=-0.531, P=0.026), and there was no correlation in bilateral aphakia group (r=-0.324, P=0.165). CONCLUSION: Aphakic children due to congenital cataract surgery have a greater CCT than normal children. It is necessary to consider CCT in evaluating IOP for children after congenital cataract surgery. 展开更多
关键词 congenital cataract surgery aphaka central corneal thickness introcular pressure
下载PDF
Changes in intraocular pressure and central corneal thickness during pregnancy:a systematic review and Meta-analysis 被引量:2
4
作者 Chao Wang Ai-Ling Li +2 位作者 Yu Pang Ying-Qing Lei Ling Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1573-1579,共7页
AIM:To conduct a Meta-analysis for investigating the variations in intraocular pressure(IOP)and central corneal thickness(CCT)during normal pregnancy.METHODS:We searched for clinical trials published up to Novem... AIM:To conduct a Meta-analysis for investigating the variations in intraocular pressure(IOP)and central corneal thickness(CCT)during normal pregnancy.METHODS:We searched for clinical trials published up to November 2015 without language or region restrictions in Pub Med,EMBASE,Web of Science,the Cochrane Central Register of Controlled Trials,Ovid,EBSCO,Elsevier,the Chinese Biomedicine Database,Wan Fang,CNKI,CQVIP and Google Scholar.Studies of the ocular changes observed in pregnant women were selected.The main outcomes were assessed by changes in IOP and CCT.RESULTS:Fifteen studies were included.In subgroup analyses,IOP was significantly decreased during the second MD=-1.53,95%CI(-2.19,-0.87);P〈0.00001,and third MD=-2.91,95%CI(-3.74,-2.08);P〈0.00001 trimesters of pregnancy.CCT was increased during the second MD=10.12,95%CI(2.01,18.22);P=0.01,trimester of pregnancy;moreover,during the third trimester of pregnancy,the CCT displayed an increasing trend,but the difference was not significant MD=5.98,95%CI(-1.11,13.07);P=0.1.CONCLUSION:A decrease in IOP is accompanied by an increase in CCT in the second and third trimesters of a normal pregnancy in women. 展开更多
关键词 intraocular pressure central corneal thickness PREGNANCY META-ANALYSIS
下载PDF
Corneal endothelial cell density and morphology and central corneal thickness in Guangxi Maonan and Han adolescent students of China 被引量:2
5
作者 Hao Liang Hui-Yi Zuo +6 位作者 Jin-Mao Chen Jie Cai Yu-Zhua Qin Yu-Ping Huang Ying-Ying Chen Dong-Yong Tang Shao-Jian Tan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第3期608-611,共4页
AIM: To investigate the corneal endothelial cell density and morphology and central corneal thickness in the Guangxi Maonan and Han adolescent students of China.METHODS: Noncontact specular microscope(Topcon SP3000 P,... AIM: To investigate the corneal endothelial cell density and morphology and central corneal thickness in the Guangxi Maonan and Han adolescent students of China.METHODS: Noncontact specular microscope(Topcon SP3000 P, Tokyo, Japan) was performed in 133 adolescent students of Maonan nationality(M:F 54:79)and 105 adolescent students of Han nationality(M:F 50:55),5 to 20 y of age, who were randomly selected from 3schools in Huanjiang Maonan Autonomous County of Guangxi Zhuang Autonomous Region of China.Parameters studied included endothelial cell density,mean cell area, coefficient of variation in cell size,percentage hexagonality and central corneal thickness. RESULTS: Endothelial cell density, mean cell area,coefficient of variation in cell size, percentage hexagonality and central corneal thickness in the study population were(2969.50 ±253.93) cells/mm2,(339.23 ±29.44) μm2,(29.96 ±4.07) %,(64.58 ±9.41) % and(523.71 ±32.82) μm in Maonan and(2998.26 ±262.65) cells/mm2,(336.11±30.07) μm2,(29.89±5.03) %,(64.91±11.64) % and(524.39 ±33.15) μm in Han, respectively. No significant differences were observed in endothelial cell density,mean cell area, coefficient of variation in cell size,percentage hexagonality and central corneal thickness between Maonan and Han(P =0.615, 0.659, 0.528, 0.551,0.999). In Maonan and Han, we found age was negatively correlated with endothelial cell density and percentagehexagonality and positively correlated with mean cell area and coefficient of variation in cell size. Negative correlation was also found between central corneal thickness and age in Han, whereas no correlation was found in Maonan. CONCLUSION: There were no differences between Maonan and Han in corneal endothelial cell density and morphology and central corneal thickness. In these two nationalities, there were statistically significant decrease in endothelial cell density and percentage hexagonality with increasing age and statistically significant increase in cell area and coefficient of variation in cell size with increasing age. Central corneal thinned with increasing age in Han, whereas difference did not attain statistical significance in Maonan. 展开更多
关键词 endothelial cell density MORPHOLOGY central corneal thickness Maonan
下载PDF
Central corneal thickness measurements in premature infants 被引量:1
6
作者 Murat Gunay Gokhan Celik +3 位作者 Betul Onal Gunay Mahmut Dogru Tugba Gursoy Husnu Fahri Ovali 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期496-500,共5页
AIM:To evaluate the central corneal thickness(CCT)measurements of premature infantsMETHODS:The premature infants who were born between 25-34wk of gestational age(GA)were retrieved for the study.All CCT measurements we... AIM:To evaluate the central corneal thickness(CCT)measurements of premature infantsMETHODS:The premature infants who were born between 25-34wk of gestational age(GA)were retrieved for the study.All CCT measurements were performed within the first 2d of their life under topical anesthesia by using an ultrasonic pachymeter.RESULTS:The mean CCT of 200 eyes was 647.79±63.94μm.The mean CCT of the right and left eyes were similar(647.30±64.72μm and 648.29±63.47μm consecutively).The mean CCT of the girls was 642.08±54.89μm and the boys was 653.07±71.14μm,with no statistically significant difference(P】0.05).But there was a negative correlation of the CCT with GA and birth weight(BW)(P【0.01).CONCLUSION:The CCT values of premature babies were negatively correlated with GA and BW. 展开更多
关键词 central corneal thickness MEASUREMENT PREMATURITY
下载PDF
The Influence of Central Corneal Thickness and Corneal Curvature and Axial Length on the Measurement of Intraocular Pressure 被引量:2
7
作者 QingLi ZhigangFan 《眼科学报》 2002年第3期176-180,共5页
Purpose: To examine the influence of central corneal thickness (CCT), corneal curvature (CC), and axial length (AL) on intraocular pressure (IOP).Methods: Eighty-one clinically normal eyes were included in our study. ... Purpose: To examine the influence of central corneal thickness (CCT), corneal curvature (CC), and axial length (AL) on intraocular pressure (IOP).Methods: Eighty-one clinically normal eyes were included in our study. The IOP, CCT, CC, AL were measured using a Goldmann applanation tonometer, optical pachymeter, keratometer and A-scan ultrasound biometer respectively in all subjects.Results: A highly significant positive correlation was identified between IOP and CCT. Linear regression analysis suggests that an increase in CCT of 0. 010 mm is associated with a 4. 946 mmHg increment in IOP. No significant positive correlation was identified between IOP and CC. P values are 0. 724 and 0.414 respectively for vertical and horizontal readings. A paradoxically reversed correlation was present between IOP and axial length.Conclusion: Corneal thickness is a very important confounding factor in the measurement of intraocular pressure, which warrants further attention in our clinical practice. 展开更多
关键词 角膜中央厚度 角膜曲度 视轴长度 眼内压测量 影响
下载PDF
Measurement of central corneal thickness and precorneal tear film thickness of rabbits using the Scheimpflug system
8
作者 Jing Dong Qiang Wu Xiao-Gang Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期584-587,共4页
AIMTo measure central corneal thickness (CCT) and pre-corneal tear film thickness using the Galilei dual-Scheimpflug analyzer (GSA) in New Zealand white rabbits.
关键词 tear film SCHEIMPFLUG RABBITS central corneal thickness FLUORESCEIN
下载PDF
Central Corneal Thickness in Adult Chinese
9
作者 李鹏程 胡燕华 +2 位作者 徐茜 张光明 麦才铿 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期141-144,共4页
The central corneal thickness (CCT) in age 48 years or less of Chinese was characterized and its relationship with gender, age, refraction and intraocular pressure (IOP) was investigated. Right eyes of 1669 partic... The central corneal thickness (CCT) in age 48 years or less of Chinese was characterized and its relationship with gender, age, refraction and intraocular pressure (IOP) was investigated. Right eyes of 1669 participants were included in this study (880 men, 52.7 % and 789 women, 47.3 %). Mean age of the samples was 23.8±5.9 years. After the examination of corneal topography and refraction, Goldman applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter. Six measurements were made at the center of the cornea of each eye. The mean value was used for analysis. The results showed that mean CCT of male participants was 551.33±34.62 μm, 5.79μm more than that of female participants. Linear regression analyses revealed that CCT was negatively related with age only in female and no association was found between refractive status and CCT. IOP was positively related to CCT, and there was a difference in IOP of 1.5 mmHg (1 mmHg=0. 133 kPa) per 100 μm difference in CCT. Ocular hypertension group was prone to have thicker cornea than average. The results indicated that in adult Chinese CCT tended to decrease with aging in female only. IOP measured by Goldmann tonometry was positively related with CCT so that CCT should be measured a- long with IOP. 展开更多
关键词 central corneal thickness intraocular pressure GENDER age REFRACTION
下载PDF
Effect of silicone oil removal on central corneal thickness
10
作者 Gul Arikan Zeynep Ozbek +2 位作者 F Hakan Oner Ismet Durak A Osman Saatci 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第3期374-376,共3页
AIM:To evaluate the effect of silicone oil removal(SOR) on central corneal thickness(CCT) in aphakic and pseudophakic eyes prospectively.· METHODS:Patients who underwent SOR surgery between June 2005-August 2007 ... AIM:To evaluate the effect of silicone oil removal(SOR) on central corneal thickness(CCT) in aphakic and pseudophakic eyes prospectively.· METHODS:Patients who underwent SOR surgery between June 2005-August 2007 were included in this study.Silicon oil was actively removed behind the posterior capsule through the pars plana sclerotomy site(posterior approach) in pseudophakic eyes and through the pupil and the corneal tunnel incision(anterior approach) in aphakic eyes with the 18-gauge cannula.CCT was assessed with Orbscan II corneal topography system preoperatively and at one month and three months postoperatively.A total of 34 eyes of 34 patients(26 males,8 females) comprised the study group.Mean age was(55.6±12.3) years(Range:25-80 years).Twenty-six eyes(76.5%) were pseudophakic and 8(23.5%) aphakic.Mean time between silicone oil injection and removal was(15.1±13.6) months(Range:5-54 months).At baseline,CCT was 576.4±46.0μm in pseudophakic eyes and 611.6±36.2μm in aphakic eyes.· RESULTS:At the first postoperative month CCT was(573.3±40.1)μm and(630.9±72.9)μm in pseudophakic and aphakic eyes respectively.At the third postoperative month,CCT was(582.7±49.5)μm and(614.5±82.4)μm in pseudophakic and aphakic eyes respectively.There was no statistically significant difference in CCT measurements one month and 3 months after SOR when compared to preoperative values in both aphakic and pseudophakic eyes(P> 0.05).· CONCLUSION:Active SOR either by anterior or posterior approach did not affect the CCT.· 展开更多
关键词 APHAKIA central corneal thickness silicone oil PSEUDOPHAKIA
下载PDF
Effect of 2% fluorescein on Scheimpflug central corneal thickness measurements
11
作者 Stella Briggs Marwa Bin Moammar 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第2期239-242,共4页
AIM: To assess central corneal thickness (CCT) changes measured with Scheimpflug device following instillation of 2% fluorescein in normal subjects. ~ METHODS: This was a prospective randomized study of 60 hospita... AIM: To assess central corneal thickness (CCT) changes measured with Scheimpflug device following instillation of 2% fluorescein in normal subjects. ~ METHODS: This was a prospective randomized study of 60 hospital volunteers. After baseline CCT measurements of both eyes of 40 subjects were obtained using Scheimpflug system, a drop of preservative-free 2% fluorescein, was instilled in one eye and in other eye, one drop of normal saline (control). Measurements were repeated after 1, 2, 5, 10, 20, 30, 40, 50 and 60min (continuous assessment group). Twenty subjects had baseline CCT taken, then fluorescein was instilled in one eye and measurements were taken at lmin. Ten eyes had saline rinse after lmin and 10 other eyes did not, measurements were repeated at 2min (eye rinse group). RESULTS: The mean baseline CCT for continuous assessment group was 546.2±32.1um (range, 489.0-606.0), control eyes was 546.6~±30.7 um (range, 489.0-602.0). At lmin after fluorescein instillation, CCT significantly increased by 37.0±34.0um (P〈0.001), then decreased gradually, reaching baseline at 60min. CCT variations were not significant in control group (P〉0.05). For eye rinse group, CCT mean differences between baseline and 2min were 18.2um (95 % Ch -54.7 to 18.3) with rinse and 26.5um (95% CI: -62.9 to 9.9) without rinse; paired sample tests were not significant (P〉0.05). CONCLUSION: The presence of fluorescein increased CCT value to a clinically relevant level of 6.8%. Eye rinse did not significantly reduce the effect at 2min post fluorescein timepoint. 展开更多
关键词 central corneal thickness FLUORESCEIN Scheimpflug device
下载PDF
Variation in Central Corneal Thickness during Open- or Closed-Eye Riboflavin Instillation for Corneal Collagen Cross-linking
12
作者 Na Li Xiujun Peng +2 位作者 Zhengjun Fan Xu Pang Yu Xia 《Eye Science》 CAS 2013年第4期185-189,共5页
Purpose:To assess the effect of having an open or closed eye on the variation in central corneal thickness during riboflavin instillation for corneal collagen cross-linking (CXL).Methods:.Thirty eyes of 15 New Zealand... Purpose:To assess the effect of having an open or closed eye on the variation in central corneal thickness during riboflavin instillation for corneal collagen cross-linking (CXL).Methods:.Thirty eyes of 15 New Zealand White rabbits underwent an in vivo anterior segment optical coherence tomography (OCT) examination at 0,10,20,and 30 min after riboflavin instillation on the de-epithelialized corneal surface.Each eye of every rabbit was randomly placed into one of two different treatment groups(open-eye or closed-eye)during the instillation;.the examinations were performed one after the other.After instillation for 30 min,the changes in the corneal stroma and anterior chamber were observed by slit lamp.Results:.A significant decrease in the central corneal thickness(CCT).was demonstrated during riboflavin instillation;.the variations were smaller in the measurements performed with the eye closed than with the eye open.(81.36±15.13μm and129.20±12.05μm respectively)..Both methods turned the corneal stroma and anterior chamber yellow.Conclusion:Keeping the eye closed during riboflavin instillation reduced the decrease in the CCT..The same yellow change in the corneal stroma and anterior chamber occurred,but the exposure time of the ocular surface was shorter.Therefore,.keeping the eye closed was a more effective and safer method than keeping the eye open. 展开更多
关键词 核黄素 膜厚度 角膜 滴注 中央 交联 胶原 新西兰白兔
下载PDF
Comparison of Central Corneal Thickness using Ultrasound Pachymetry during Corneal Collagen Cross-linking
13
作者 Xu Pang Xiujun Peng +2 位作者 Zhengjun Fan Hongzhen Jia Tengfei Wu 《Eye Science》 CAS 2013年第1期15-19,共5页
Purpose:To study variation in central corneal thickness (CCT) during corneal collagen cross-linking(CXL) using ultrasound pachymetry. Methods:Twenty patients (26 eyes) with progressing keratoconus undergoing riboflavi... Purpose:To study variation in central corneal thickness (CCT) during corneal collagen cross-linking(CXL) using ultrasound pachymetry. Methods:Twenty patients (26 eyes) with progressing keratoconus undergoing riboflavin-UVA-induced CXL were involved in this study. Intraoperative CCT measurement using ultrasonic pachymetry was performed during the procedure.Measurements were obtained before operation, after epithelial removal, after riboflavin drop instillation, and after UVA irradiation. Results:Mean CCT was 495±56 and 450±52 μm before and after epithelial removal, respectively. Mean CCT was 443±42 and 411±39 μm after riboflavin drop instillation and after UVA irradiation, respectively. Statistically significant decreases in CCT occurred between the preoperative period and after epithelial removal, after riboflavin drop instillation and after UVA irradiation. Twenty-six eyes from 20 patients undergoing CXL were divided into 2 groups (I with CCT≥400 μm after UVA irradiation and II with CCT<400 μm after UVA irradiation). No statistically significant difference was noted between I and II in preoperative endothelial cell count, but a statistically greater postoperative endothelial cell count was noted in I compared to II. A statistically significant difference was evident between preoperative and postoperative endothelial cell counts in Group II (P<0.05). Conclusion:Performing CXL with the use of riboflavin and UVA irradiation resulted in a statistically significant decrease in CCT, to a level where the corneal endothelium may be damaged.(Eye Science 2013; 28:15-19) 展开更多
关键词 角膜内皮细胞 超声测厚仪 交联过程 膜厚度 中央 胶原 超声波测厚仪 细胞计数
下载PDF
Difference in normal corneal thickness and curvature between Mongolian and Han nationalities 被引量:1
14
作者 Hai-Xia Zhao Li Zhang Wen-Ying Guan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第2期399-402,共4页
AIM: To investigate the differences in central corneal thickness(CCT) and curvature in myopic patients with different genders between Mongolian and Han nationalities in the Inner Mongolia region.METHODS: Patients with... AIM: To investigate the differences in central corneal thickness(CCT) and curvature in myopic patients with different genders between Mongolian and Han nationalities in the Inner Mongolia region.METHODS: Patients with myopia, among whom 122cases(244 eyes) were Mongolian and 150 cases(300eyes) were Han, were selected. Pentacam was used to measure the corneal curvature, whereas CCT was determined by Pentacam, Orbscan and ultrasound pachymetry.RESULTS: Comparisons of the curvature of men and women in Mongolia showed a significant difference(P 【0.05) by comparing of the CCT values measured by three methods in Han and Mongolian in Inner Mongolia, we can draw a conclusion that the CCT values measured by Pentacam are less than the values by Orbscan and ultrasound pachymetry, and there are statistically significant difference in CCT measurement among the instruments except between the Orbscan and ultrasound pachymetry. The CCT values of Mongolians are more than Han people, and the analysis exhibited statistical significance. The CCT values measured by Orbscan in Mongolia of women are more than men, the difference showed statistical significance.CONCLUSION: Corneal curvature in Mongolian females was significantly higher than that in males. However, no significant difference was observed among Han males and females. The CCT values of Mongolian females were higher than those of males. The normal CCT values measured by Pentacam in Mongolian myopic patients were smaller than those obtained by Orbscan or ultrasound. The normal CCT values of Mongolian patients with myopia were higher than those reported for domestic people. 展开更多
关键词 PENTACAM ORBSCAN mongolian nationality Han nationality GENDER central corneal thickness
下载PDF
Manifestations of type 2 diabetes in corneal endothelial cell density,corneal thickness and intraocular pressure 被引量:3
15
作者 Stella Briggs Uchechukwu L Osuagwu Essam M AlHarthi 《The Journal of Biomedical Research》 CAS CSCD 2016年第1期46-51,共6页
We sought to evaluate central corneal thickness(CCT),corneal endothelial cell density(ECD)and intraocular pressure(IOP)in patients with type 2 diabetes mellitus(DM)and to associate potential differences with d... We sought to evaluate central corneal thickness(CCT),corneal endothelial cell density(ECD)and intraocular pressure(IOP)in patients with type 2 diabetes mellitus(DM)and to associate potential differences with diabetes duration and treatment modality in a prospective,randomized study.We measured ECD,CCT and IOP of125 patients with type 2 DM(mean age 57.1±11.5 years)and compared them with 90 age-matched controls.Measured parameters were analyzed for association with diabetes duration and glucose control modalities(insulin injection or oral medication)while controlling for age.In the diabetic group,the mean ECD(2511±252 cells/mm^2),mean CCT(539.7±33.6μm)and mean IOP(18.3±2.5 mmHg)varied significantly from those the control group[ECD:2713±132 cells/mm^2(P〈0.0001),CCT:525.0±45.3μm(P=0.003)and IOP:16.7±1.8 mmHg(P〈0.0001)].ECD was significantly reduced by about 32 cell/mm^2 for diabetics with duration of〉10 years when compared with those with duration of〈10 years(P〈0.05).CCT was thicker and IOP was higher for diabetics with duration of〉10 years than those with duration of〈10 years(P〉0.05).None of the measured parameters was significantly associated with diabetes duration and treatment modality(P〉0.05).In conclusion,subjects with type 2DM exhibit significant changes in ECD,IOP and CCT,which,however,are not correlated with disease duration or if the patients receive on insulin injection or oral medications. 展开更多
关键词 type 2 diabetes corneal endothelial cells central corneal thickness diabetes duration and control
下载PDF
Blue-on-yellow perimetry and corneal thickness in patients with ocular hypertension
16
作者 Yi-Sheng Zhong Li-Ping Chen and Yu Cheng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第6期623-626,共4页
AIM: To evaluate the frequency of blue-on-yellow perimetry (B/YP) deficits in ocular hypertension (OHT) patients and to correlate these findings with central corneal thickness (CCT), and to investigate the influence o... AIM: To evaluate the frequency of blue-on-yellow perimetry (B/YP) deficits in ocular hypertension (OHT) patients and to correlate these findings with central corneal thickness (CCT), and to investigate the influence of age, refraction and gender on the B/YP results in OHT patients. METHODS: The B/YP and CCT were checked respectively in 72 OHT patients with normal white-on-white perimetry (W/WP) and normal optic nerve head. The B/YP was tested by Octopus 101 automated perimetry using G2 strategy, while the CCT was checked with DGH-550 ultrasound pachymeter. All patients were chosen randomly one eye for statistical analysis, a binary regression model was used to determine the independent contribution of variables included in the model, and the differences of the intraocular pressure (TOP), CCT, age, refraction and gender between the normal B/YP group and abnormal B/YP group were compared. RESULTS: Forty-nine out of 72 patients with OHT showed normal B/YP results, whereas 23 of 72 patients (31.9%) demonstrated abnormal B/YP results. CCT showed a correlation with the B/YP results (B=-0.038, SE=0.019, P=0.044), whereas none of the TOP, age, refraction and gender was found to be correlated with the B/YP results. The mean CCT in OHT patients with abnormal B/YP group was lower than that with normal B/YP group (t=2.066, P=0.043). There was a significant positive correlation between TOP and CCT (R(2)=0.513, P=0.000). CONCLUSION: The mean CCT in OHT patients with abnormal B/YP results was lower than that with normal B/YP results. There was a significant positive correlation between TOP and CCT in OHT patients. The age, refraction and gender didn't influence the B/YP results in OHT patients. 展开更多
关键词 ocular hypertension blue-on-yellow perimetry central corneal thickness visual function
下载PDF
Comparison of Corneal Thickness of Young People with Middle and High Myopia between Shantou and Zhengzhou
17
作者 Lixia Sun Yue Song +2 位作者 Riping Zhang Zhongren Zheng Yang Wang 《Eye Science》 CAS 2012年第1期41-43,共3页
Purpose:To compare the corneal thickness of young subjects (aged 18 to 30 years).with moderate and high myopia living in Shantou and Zhengzhou.Methods:One hundred and forty myopic subjects from Shantou (Guangdong,sout... Purpose:To compare the corneal thickness of young subjects (aged 18 to 30 years).with moderate and high myopia living in Shantou and Zhengzhou.Methods:One hundred and forty myopic subjects from Shantou (Guangdong,southern China) and 101 from Zhengzhou (Henan,central China)were selected and divided into 2 groups (moderate-myopic group and high-myopic group).The participants were sex-and age-matched.The central corneal thickness (CCT) and thinnest corneal thickness (TCT) were measured by Orbscan and compared between the two groups.Results:In the high-myopic group,CCT (515.47±40.39 μm) and TCT (510.22±40.95 μm) of the Shantou subjects (mean spherical equivalent.[SE]-7.56±1.35),were thinner than those of their Zhengzhou counterparts.(mean SE-7.47 ±0.88).In the moderate-myopic group.(Shantou mean SE-4.52 ±0.83;Zhengzhou-4.67 ± 0.77),CCT and TCT did not differ between the two cities.Conclusion:The corneal thickness of high-myopic eyes may differ between Shantou and Zhengzhou. 展开更多
关键词 膜厚度 汕头市 近视 郑州 年轻人 中国南方 中部地区 cct
下载PDF
Relationship between Corneal Thickness,Corneal Curvature,and Intraocular Pressure before and after Laser Treatment for Simple Myopia
18
作者 Ahmad M.A Edrees M.H Jafarzadehpur E 《Eye Science》 CAS 2014年第2期70-73,共4页
Purpose:.To determine the relationship of central corneal thickness(CCT), curvature(CC), and intraocular pressure(IOP) as determinative factors for corneal biomechanics and in refractive surgery.Methods:.The study inv... Purpose:.To determine the relationship of central corneal thickness(CCT), curvature(CC), and intraocular pressure(IOP) as determinative factors for corneal biomechanics and in refractive surgery.Methods:.The study investigated 48 eyes from subjects who visited the Excimer Laser Surgery Clinic at the Department of Ophthalmology. The refractive error, IOP, CCT, and CC were measured in all participants. After 3 months, all examinations were repeated.Results:.Linear regression demonstrated a significant positive relationship between pre- and postoperative CCT,.CC,.and IOP values..The IOP showed a significant correlation with CCT(P=0.033) for pre-PRK, but no significant relationship was seen post-PRK. The CCT also correlated significantly with CC both pre- and post-PRK(P<0.05).Conclusion:.The IOP was significantly correlated with CCT before PRK, but its behavior differed after surgery. Nearly the same correlation was seen between CCT and CC before and after the PRK;.nevertheless,.IOP measurements should be calculated or estimated more precisely after PRK based on CCT corrections. 展开更多
关键词 膜厚度 激光治疗 角膜 内压 激光手术 曲率 近视 线性回归分析
下载PDF
不同光学测量设备测量近视眼中央角膜厚度的一致性评估
19
作者 杨兰 何玉枚 +3 位作者 赵芳 韩媛 夏桂花 徐曼 《中华实验眼科杂志》 CAS CSCD 北大核心 2024年第9期814-819,共6页
目的比较角膜内皮镜SP-1P、IOLMaster 700、Pentacam HR三维眼前节分析诊断系统及RTVue XR-OCT 4种不同设备测量中央角膜厚度(CCT)的差异和一致性。方法采用诊断试验研究方法,连续选取2022年1—5月于武汉爱尔眼科汉阳医院拟行角膜屈光... 目的比较角膜内皮镜SP-1P、IOLMaster 700、Pentacam HR三维眼前节分析诊断系统及RTVue XR-OCT 4种不同设备测量中央角膜厚度(CCT)的差异和一致性。方法采用诊断试验研究方法,连续选取2022年1—5月于武汉爱尔眼科汉阳医院拟行角膜屈光手术的低中度近视患者50例50眼,由同一检查者分别采用角膜内皮镜SP-1P、IOLMaster 700、Pentacam HR和RTVue XR-OCT测量CCT,比较4种仪器测量CCT值的差异;分别采用Pearson线性相关分析和Bland-Altman一致性检验评估各种仪器测量CCT值之间的相关性和一致性。结果角膜内皮镜SP-1P、IOLMaster 700、Pentacam HR和RTVue XR-OCT测得的CCT平均值分别为(522.68±30.08)、(544.06±32.85)、(541.00±31.75)和(528.86±31.60)μm,总体比较差异有统计学意义(F=5.09,P=0.002),其中角膜内皮镜SP-1P测量值低于IOLMaster 700和Pentacam HR,IOLMaster 700测量值高于RTVue XR-OCT,差异均有统计学意义(均P<0.05)。Pearson相关分析显示,角膜内皮镜SP-1P与IOLMaster 700、角膜内皮镜SP-1P与Pentacam HR、角膜内皮镜SP-1P与RTVue XR-OCT、IOLMaster 700与Pentacam HR、IOLMaster 700与RTVue XR-OCT、Pentacam HR与RTVue XR-OCT测量的CCT值均呈显著正相关(r=0.988、0.980、0.988、0.981、0.982、0.973,均P<0.01)。Bland-Altman一致性分析结果显示,角膜内皮镜SP-1P与RTVue XR-OCT、IOLMaster 700与Pentacam HR测量CCT值的95%一致性界限(95%LoA)分别为-16.46~6.14、-10.56~14.48μm,分别有3个(6%)、2个(4%)点落在95%LoA外,测量CCT差异均值线与0距离较小,一致性较好,差异均无统计学意义,在临床上可以接受。结论角膜内皮镜SP-1P与RTVue XR-OCT、IOLMaster 700与Pentacam HR测量低中度近视患者CCT的值较接近,一致性好,可相互替代。 展开更多
关键词 中央角膜厚度 角膜内皮镜 IOLMASTER Pentacam HR RTVue XR-OCT
下载PDF
Sirius Scheimpflug-Placido versus. ultrasound pachymetry for central corneal thickness: meta-analysis
20
作者 Yili Jin Colm McAlinden +8 位作者 Yong Sun Daizong Wen Yiran Wang Jinjin Yu Ke Feng Benhao Song Qinmei Wang Shihao Chen Jinhai Huang 《Eye and Vision》 SCIE CSCD 2023年第4期1-11,共11页
Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound ... Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was-11.26μm with a 95%confidence interval(CI)(-16.92μm,-5.60μm).The heterogeneity Was IP=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference. 展开更多
关键词 META-ANALYSIS central corneal thickness Scheimpflug-Placido topographer Ultrasound pachymetry