The extraction kinetics of Ce(Ⅳ) and Ce(Ⅳ)-F^- mixture systems from sulfuric solutions to n-heptane solution containing Bif-ILE[A336][P204]([trialkylmethylammonium][di-2-ethylhewanxylphosphinate]) with a const...The extraction kinetics of Ce(Ⅳ) and Ce(Ⅳ)-F^- mixture systems from sulfuric solutions to n-heptane solution containing Bif-ILE[A336][P204]([trialkylmethylammonium][di-2-ethylhewanxylphosphinate]) with a constant interfacial area cell with laminar flow were studied,just to elucidate the extraction mechanism and the mass transfer models.The data were analyzed in terms of pseudo-first-order constants.The effects of stirring speed,specific interfacial area and temperature on the extraction rate in both systems were discussed,suggesting that the extractions were mixed bulk phases-interfacial control process.Supported by the experimental data,the corresponding rate equations for Ce(Ⅳ) extraction system and Ce(Ⅳ)-F^- mixture extraction system were obtained.The experimental results indicated the rate-controlling step.The kinetics model was deduced from the rate-controlling step and consistent with the rate equation.展开更多
目的:探讨全髋关节置换术的CroweⅢ-Ⅳ型发育性髋关节发育不良(developmental dysplasia of the hip,DDH)患者的满意度及造成不满意的相关因素。方法:回顾性分析2013年3月至2018年3月行全髋关节置换术的169例CroweⅢ-Ⅳ型DDH患者,通过...目的:探讨全髋关节置换术的CroweⅢ-Ⅳ型发育性髋关节发育不良(developmental dysplasia of the hip,DDH)患者的满意度及造成不满意的相关因素。方法:回顾性分析2013年3月至2018年3月行全髋关节置换术的169例CroweⅢ-Ⅳ型DDH患者,通过微信进行调查问卷,调查患者对手术总体满意度、10项日常功能满意度和患者认为对自己日常生活影响比较大的前5个问题。手术前后采用髋关节Harris评分进行功能评价。结果:收到完整调查问卷145份,所有患者获随访,时间1~5(3.23±1.22)年。145例患者分成两组,其中对手术疗效满意的118例,不满意的27例,手术总体满意率81.38%(118/145)。患者认为对生活影响比较大的前5个问题分别是术后髋部疼痛,肢体明显不等长、行走、上下楼梯、蹲起。两组术前Harris评分比较,差异无统计学意义(P>0.05),不满意组术后Harris评分较低。术后髋关节疼痛、肢体不等长是影响手术不满意的直接因素。结论:采用全髋关节置换术治疗CroweⅢ-Ⅳ型DDH患者手术难度大;术后髋关节疼痛(轻度以上),肢体不等长(>2 cm)是术后不满意的独立危险因素。展开更多
A new chemiluminescence (CL) method for the determination of tetracycline and oxytetracycline is developed, hased on the CL reaction of tetracycline and oxytetracycline with Ru(bipy)_3~2+ and Ce(IV). In sulfuric acid ...A new chemiluminescence (CL) method for the determination of tetracycline and oxytetracycline is developed, hased on the CL reaction of tetracycline and oxytetracycline with Ru(bipy)_3~2+ and Ce(IV). In sulfuric acid medium, the CL emission is generated upon continuous oxidation of Ru(bipy)_3~2+ by cerium (IV ). The emission intensity is greatly enhanced when tetracycline and oxytetracycline are introduced into the reaction system after acid degradation. Under the optimum conditions, the calibration curves are linear over the range of 8. 0 X 10^-8^-4. 0 X 10^-6 mol/L for tetracycline and of 2. 0 X 10^-7~4. 0 X 10^-5 mol/L for oxytetracycline, with the detection limits are 4. 2 X 10^-8 mol/L for tetracycline and 1. 5 X 10^-7 mol/L for oxytetracycline, respectively. The proposed method was used for the determination of tetracycline and oxytetracycline in pharmaceutical formulations with good results.展开更多
Tributyl phosphate (TBP) solvent was used for impregnation into Amberlite XAD-16 nonionic polymeric resin beads using the wet method to prepare solvent impregnated resin (SIR). Undiluted TBP in a ratio to the resi...Tributyl phosphate (TBP) solvent was used for impregnation into Amberlite XAD-16 nonionic polymeric resin beads using the wet method to prepare solvent impregnated resin (SIR). Undiluted TBP in a ratio to the resin support (volume to mass) of 6.0 at room temperature (RT) in 24 h was impregnated the resin with a mass ratio of 1.944, while the prepared gross sample of SIR at the ratio of solvent to resin of 3.0 was impregnated with a mass ratio of 1.88. Cerium(Ⅳ) oxide concentrate, prepared from crude Egyptian monazite sand, containing 37% cerium, 1.6% thorium and about 40% the other trivalent rare earth oxides, was used to prepare cerium(Ⅳ) nitrate solution for extraction using the prepared SIR. The impregnated resin was satisfactory for Ce(Ⅳ) extraction from nitric acid medium at room temperature. Cerium loading capacity of the impregnated resin reached 95.6% of the calculated theoretical capacity (173 g/kg (Ce/SIR)) under the conditions of 51.57 g/L cerium and 2.48 g/L thorium, 5.0 mol/L free nitric acid, solution to resin ratio of 10.0 and contacting the phases for 5.0 min. The loading capacity reached 98.75% when cerium concentration was increased to 91.43 g/L under the same conditions.展开更多
In this study, the kinetics and mechanism of the iridium( Ⅲ ) -catalyzed oxidation of ethanol amine(EAN) by cerium(Ⅳ) in a sulfuric acid medium was investigated using titrimetric technique of redox in a temper...In this study, the kinetics and mechanism of the iridium( Ⅲ ) -catalyzed oxidation of ethanol amine(EAN) by cerium(Ⅳ) in a sulfuric acid medium was investigated using titrimetric technique of redox in a temperature range of 298--313 K. It was found that the reaction is of first order with respect to Ce( Ⅳ ) and It( Ⅲ ), and a positive fractional order with respect to EAN. It was also found that the pseudo-first-order ( [EAN ] 〉〉 [ Ce ( Ⅳ) ] ) rate constant koba decreases with the increase of [ H^+ ] and [ HSO^-4 ]. Under the protection of nitrogen gas, the reaction system can initiate the polymerization of acrylonitrile, indicating the generation of free radicals. On the basis of the experimental results, a suitable mechanism was proposed. From the dependence of koba on the concentration of hydrogen sulfate, Ce(SO4)2 was found to be the kinetically active species. The rate constants of the rote-determining step together with the activation parameters were evaluated.展开更多
基金Project (2012CBA01202) supported by the National Basic Research Program of ChinaProject (51174184) supported by the National Natural Science Foundation of China+2 种基金Project (KGZD-EW-201-1) supported by the Key Research Program of the Chinese Academy of SciencesProject (BK2013030) supported by Science and Technology Plan of Nantong City,ChinaProject (RERU2014016) supported by Open Subject of Changchun Institute of Applied Chemistry,Chinese Academy of Sciences,China
文摘The extraction kinetics of Ce(Ⅳ) and Ce(Ⅳ)-F^- mixture systems from sulfuric solutions to n-heptane solution containing Bif-ILE[A336][P204]([trialkylmethylammonium][di-2-ethylhewanxylphosphinate]) with a constant interfacial area cell with laminar flow were studied,just to elucidate the extraction mechanism and the mass transfer models.The data were analyzed in terms of pseudo-first-order constants.The effects of stirring speed,specific interfacial area and temperature on the extraction rate in both systems were discussed,suggesting that the extractions were mixed bulk phases-interfacial control process.Supported by the experimental data,the corresponding rate equations for Ce(Ⅳ) extraction system and Ce(Ⅳ)-F^- mixture extraction system were obtained.The experimental results indicated the rate-controlling step.The kinetics model was deduced from the rate-controlling step and consistent with the rate equation.
文摘目的:探讨全髋关节置换术的CroweⅢ-Ⅳ型发育性髋关节发育不良(developmental dysplasia of the hip,DDH)患者的满意度及造成不满意的相关因素。方法:回顾性分析2013年3月至2018年3月行全髋关节置换术的169例CroweⅢ-Ⅳ型DDH患者,通过微信进行调查问卷,调查患者对手术总体满意度、10项日常功能满意度和患者认为对自己日常生活影响比较大的前5个问题。手术前后采用髋关节Harris评分进行功能评价。结果:收到完整调查问卷145份,所有患者获随访,时间1~5(3.23±1.22)年。145例患者分成两组,其中对手术疗效满意的118例,不满意的27例,手术总体满意率81.38%(118/145)。患者认为对生活影响比较大的前5个问题分别是术后髋部疼痛,肢体明显不等长、行走、上下楼梯、蹲起。两组术前Harris评分比较,差异无统计学意义(P>0.05),不满意组术后Harris评分较低。术后髋关节疼痛、肢体不等长是影响手术不满意的直接因素。结论:采用全髋关节置换术治疗CroweⅢ-Ⅳ型DDH患者手术难度大;术后髋关节疼痛(轻度以上),肢体不等长(>2 cm)是术后不满意的独立危险因素。
基金the National Natural Science Foundation of China the Natural Science Foundation of Hubei Province
文摘A new chemiluminescence (CL) method for the determination of tetracycline and oxytetracycline is developed, hased on the CL reaction of tetracycline and oxytetracycline with Ru(bipy)_3~2+ and Ce(IV). In sulfuric acid medium, the CL emission is generated upon continuous oxidation of Ru(bipy)_3~2+ by cerium (IV ). The emission intensity is greatly enhanced when tetracycline and oxytetracycline are introduced into the reaction system after acid degradation. Under the optimum conditions, the calibration curves are linear over the range of 8. 0 X 10^-8^-4. 0 X 10^-6 mol/L for tetracycline and of 2. 0 X 10^-7~4. 0 X 10^-5 mol/L for oxytetracycline, with the detection limits are 4. 2 X 10^-8 mol/L for tetracycline and 1. 5 X 10^-7 mol/L for oxytetracycline, respectively. The proposed method was used for the determination of tetracycline and oxytetracycline in pharmaceutical formulations with good results.
文摘Tributyl phosphate (TBP) solvent was used for impregnation into Amberlite XAD-16 nonionic polymeric resin beads using the wet method to prepare solvent impregnated resin (SIR). Undiluted TBP in a ratio to the resin support (volume to mass) of 6.0 at room temperature (RT) in 24 h was impregnated the resin with a mass ratio of 1.944, while the prepared gross sample of SIR at the ratio of solvent to resin of 3.0 was impregnated with a mass ratio of 1.88. Cerium(Ⅳ) oxide concentrate, prepared from crude Egyptian monazite sand, containing 37% cerium, 1.6% thorium and about 40% the other trivalent rare earth oxides, was used to prepare cerium(Ⅳ) nitrate solution for extraction using the prepared SIR. The impregnated resin was satisfactory for Ce(Ⅳ) extraction from nitric acid medium at room temperature. Cerium loading capacity of the impregnated resin reached 95.6% of the calculated theoretical capacity (173 g/kg (Ce/SIR)) under the conditions of 51.57 g/L cerium and 2.48 g/L thorium, 5.0 mol/L free nitric acid, solution to resin ratio of 10.0 and contacting the phases for 5.0 min. The loading capacity reached 98.75% when cerium concentration was increased to 91.43 g/L under the same conditions.
基金Supported by the Doctoral Foundation of Education Department of Hebei Province(NoB2004205) Hebei University Re-search Foundation(No2003Z09)
文摘In this study, the kinetics and mechanism of the iridium( Ⅲ ) -catalyzed oxidation of ethanol amine(EAN) by cerium(Ⅳ) in a sulfuric acid medium was investigated using titrimetric technique of redox in a temperature range of 298--313 K. It was found that the reaction is of first order with respect to Ce( Ⅳ ) and It( Ⅲ ), and a positive fractional order with respect to EAN. It was also found that the pseudo-first-order ( [EAN ] 〉〉 [ Ce ( Ⅳ) ] ) rate constant koba decreases with the increase of [ H^+ ] and [ HSO^-4 ]. Under the protection of nitrogen gas, the reaction system can initiate the polymerization of acrylonitrile, indicating the generation of free radicals. On the basis of the experimental results, a suitable mechanism was proposed. From the dependence of koba on the concentration of hydrogen sulfate, Ce(SO4)2 was found to be the kinetically active species. The rate constants of the rote-determining step together with the activation parameters were evaluated.