Environmental pollution and declining resources of fossil fuels in recent years,have increased demand for better fuel economy and less pollution for ground transportation.Among the alternative solutions provided by re...Environmental pollution and declining resources of fossil fuels in recent years,have increased demand for better fuel economy and less pollution for ground transportation.Among the alternative solutions provided by researchers in recent decades,hybrid electric vehicles consisted of an internal combustion engine and an electric motor have been considered as a promising solution in the short-term.In the present study,fuel economy characteristics of a parallel hybrid electric vehicle are investigated by using numerical simulation.The simulation methodology is based on a fast forward facing simulation model of a parallel hybrid and an internal combustion engine powertrains.The objective of this study is to present the main parameters which result in an optimum combination of hybrid powertrain components in order to obtain a better fuel economy of hybrid powertrains regarding different driven cycles and hybridization factors.Then,the fuel consumption of the parallel hybrid electric vehicles are compared considering various driven cycles and hybridization factors.The results showed that the better fuel economy of hybrid powertrains increases by decreasing average load of the test cycle and the point of the best fuel economy for a particular average load of the cycle moves towards higher hybridization factors when the average load of the test cycle is reduced.展开更多
Electric submersible pumps account for a considerable proportion in the development of the Bohai Oilfield. Improving the system efficiency of the electric submersible pump wells, ensuring that the units operate in the...Electric submersible pumps account for a considerable proportion in the development of the Bohai Oilfield. Improving the system efficiency of the electric submersible pump wells, ensuring that the units operate in the high-efficiency zone, is essential. Analysis shows that the efficiency of the electric submersible pump system depends on the wear and tear of each component of the submersible pump equipment, the setting of operational parameters, and more importantly, the production status and daily management level of the oil well. Therefore, improving the structural performance of the submersible pump product, optimizing the parameters setting of the oil well, strengthening daily management, establishing a scientific management system, and improving the production management process and system can effectively improve the production efficiency and economic benefits of the oil well, and further achieve the goal of energy saving and emission reduction. In addition, it is necessary to actively promote the concept and technology of energy saving and emission reduction, encourage oilfield enterprises to explore effective measures to reduce the energy consumption of the electric submersible pump system by strengthening the scientific management system, and achieve a green, low-carbon, and high-quality development of oilfield production to achieve the unity of economic benefits, social benefits, and environmental benefits. This article applies the above measures in the P oilfield to achieve energy optimization of submersible electric pump systems, reducing the daily power consumption of single well submersible electric pump systems by 371 kWh per day, increasing the submersible electric pump's lifespan by 200 days, generating considerable project benefits.展开更多
On average, long-haul trucks in the U.S. use approximately 667 million gallons of fuel each year just for idling. This idling primarily facilitates climate control operations during driver rest periods. To mitigate th...On average, long-haul trucks in the U.S. use approximately 667 million gallons of fuel each year just for idling. This idling primarily facilitates climate control operations during driver rest periods. To mitigate this, our study explored ways to diminish the electrical consumption of climate control systems in class 8 trucks through innovative load reduction technologies. We utilized the CoolCalc software, developed by the National Renewable Energy Laboratory (NREL), which integrates heat transfer principles with extensive weather data from across the U.S. to mimic the environmental conditions trucks face year-round. The analysis of the CoolCalc simulations was performed using MATLAB. We assessed the impact of various technologies, including white paint, advanced curtains, and Thinsulate insulation on reducing electrical demand compared to standard conditions. Our findings indicate that trucks operating in the eastern U.S. could see electrical load reductions of up to 40%, while those in the western regions could achieve reductions as high as 55%. Such significant decreases in energy consumption mean that a 10 kWh battery system could sufficiently manage the HVAC needs of these trucks throughout the year without idling. Given that many long-haul trucks are equipped with battery systems of around 800 Ah (9.6 kWh), implementing these advanced technologies could substantially curtail the necessity for idling to power air conditioning systems.展开更多
In the face of the climate change, energy consumption is one of the main issues to be solved. Energy audits are useful tools that may contribute to develop energy efficiency initiatives. The purpose of this paper is t...In the face of the climate change, energy consumption is one of the main issues to be solved. Energy audits are useful tools that may contribute to develop energy efficiency initiatives. The purpose of this paper is to provide insights into how energy audits, with a scope on air conditioning (AC) systems, contribute to develop energy efficiency options for a government building in the city of Hermosillo, Mexico. The methodology is based in the energy audit framework proposed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Results show that, in a typical day of maximum consumption, AC represents 64% of the total electrical consumption, while office equipment accounted for 22%, and lighting 14%. Additionally, AC system has a yearly consumption of 54,419.40 kWh with an emission estimate of 24.92 tons of CO2-eq/year. Three approaches for energy efficiency proposals were addressed through AC systems: Improvement of the operation and consumption habits, maintenance and reconditioning of facilities, and replacement of AC units. While Mexico has international commitments through environmental treaties related to contribute to climate change mitigation, this study shows that, at least one government building still produces potential impacts that can be deterred by addressing structural and behavioral changes related to AC operation. Finally, this study may be used as reference for energy efficiency practitioners or decision-making authorities in the public administration field for developing better energy policies for government buildings.展开更多
文摘Environmental pollution and declining resources of fossil fuels in recent years,have increased demand for better fuel economy and less pollution for ground transportation.Among the alternative solutions provided by researchers in recent decades,hybrid electric vehicles consisted of an internal combustion engine and an electric motor have been considered as a promising solution in the short-term.In the present study,fuel economy characteristics of a parallel hybrid electric vehicle are investigated by using numerical simulation.The simulation methodology is based on a fast forward facing simulation model of a parallel hybrid and an internal combustion engine powertrains.The objective of this study is to present the main parameters which result in an optimum combination of hybrid powertrain components in order to obtain a better fuel economy of hybrid powertrains regarding different driven cycles and hybridization factors.Then,the fuel consumption of the parallel hybrid electric vehicles are compared considering various driven cycles and hybridization factors.The results showed that the better fuel economy of hybrid powertrains increases by decreasing average load of the test cycle and the point of the best fuel economy for a particular average load of the cycle moves towards higher hybridization factors when the average load of the test cycle is reduced.
文摘Electric submersible pumps account for a considerable proportion in the development of the Bohai Oilfield. Improving the system efficiency of the electric submersible pump wells, ensuring that the units operate in the high-efficiency zone, is essential. Analysis shows that the efficiency of the electric submersible pump system depends on the wear and tear of each component of the submersible pump equipment, the setting of operational parameters, and more importantly, the production status and daily management level of the oil well. Therefore, improving the structural performance of the submersible pump product, optimizing the parameters setting of the oil well, strengthening daily management, establishing a scientific management system, and improving the production management process and system can effectively improve the production efficiency and economic benefits of the oil well, and further achieve the goal of energy saving and emission reduction. In addition, it is necessary to actively promote the concept and technology of energy saving and emission reduction, encourage oilfield enterprises to explore effective measures to reduce the energy consumption of the electric submersible pump system by strengthening the scientific management system, and achieve a green, low-carbon, and high-quality development of oilfield production to achieve the unity of economic benefits, social benefits, and environmental benefits. This article applies the above measures in the P oilfield to achieve energy optimization of submersible electric pump systems, reducing the daily power consumption of single well submersible electric pump systems by 371 kWh per day, increasing the submersible electric pump's lifespan by 200 days, generating considerable project benefits.
文摘On average, long-haul trucks in the U.S. use approximately 667 million gallons of fuel each year just for idling. This idling primarily facilitates climate control operations during driver rest periods. To mitigate this, our study explored ways to diminish the electrical consumption of climate control systems in class 8 trucks through innovative load reduction technologies. We utilized the CoolCalc software, developed by the National Renewable Energy Laboratory (NREL), which integrates heat transfer principles with extensive weather data from across the U.S. to mimic the environmental conditions trucks face year-round. The analysis of the CoolCalc simulations was performed using MATLAB. We assessed the impact of various technologies, including white paint, advanced curtains, and Thinsulate insulation on reducing electrical demand compared to standard conditions. Our findings indicate that trucks operating in the eastern U.S. could see electrical load reductions of up to 40%, while those in the western regions could achieve reductions as high as 55%. Such significant decreases in energy consumption mean that a 10 kWh battery system could sufficiently manage the HVAC needs of these trucks throughout the year without idling. Given that many long-haul trucks are equipped with battery systems of around 800 Ah (9.6 kWh), implementing these advanced technologies could substantially curtail the necessity for idling to power air conditioning systems.
文摘In the face of the climate change, energy consumption is one of the main issues to be solved. Energy audits are useful tools that may contribute to develop energy efficiency initiatives. The purpose of this paper is to provide insights into how energy audits, with a scope on air conditioning (AC) systems, contribute to develop energy efficiency options for a government building in the city of Hermosillo, Mexico. The methodology is based in the energy audit framework proposed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Results show that, in a typical day of maximum consumption, AC represents 64% of the total electrical consumption, while office equipment accounted for 22%, and lighting 14%. Additionally, AC system has a yearly consumption of 54,419.40 kWh with an emission estimate of 24.92 tons of CO2-eq/year. Three approaches for energy efficiency proposals were addressed through AC systems: Improvement of the operation and consumption habits, maintenance and reconditioning of facilities, and replacement of AC units. While Mexico has international commitments through environmental treaties related to contribute to climate change mitigation, this study shows that, at least one government building still produces potential impacts that can be deterred by addressing structural and behavioral changes related to AC operation. Finally, this study may be used as reference for energy efficiency practitioners or decision-making authorities in the public administration field for developing better energy policies for government buildings.