[Objectives]This study aimed to optimize the chelation process for complex microelement iron supplement derived from pig blood by response surface methodology.[Methods]On the basis of single-factor test,p H value,conc...[Objectives]This study aimed to optimize the chelation process for complex microelement iron supplement derived from pig blood by response surface methodology.[Methods]On the basis of single-factor test,p H value,concentration of polypeptide solution and volume ratio of polypeptide solution to FeCl_2 solution were selected as influencing factors with Fe(II)chelation rate as the indicator for Box-Behnken central composite experimental design with three factors and three levels.The effects of three factors on the response value were analyzed by response surface methodology.[Results]The optimized chelation process for complex microelement iron supplement derived from pig blood by response surface methodology was as follows:pH 5.40,polypeptide solution concentration 2.27%,volume ratio of polypeptide solution to FeCl_2 solution 2.16∶1.Under this condition,the predictive Fe(II)chelation rate of iron supplement was 79.37%,while the actual value was 79.41%.[Conclusions]The optimized process may provide new thoughts for the development and utilization of complex microelement iron supplement derived from pig blood.展开更多
To strengthen the device performance with the pattern wafer by enhancing the Cu polishing rate and improve the surface roughness with the Cu lines, a new weakly alkaline chelating agent with a barrier slurry is develo...To strengthen the device performance with the pattern wafer by enhancing the Cu polishing rate and improve the surface roughness with the Cu lines, a new weakly alkaline chelating agent with a barrier slurry is developed to meet the process demand of the advanced barrier chemical mechanical planarization(CMP). This new chelating agent has a stronger chelating ability and a lower p H value than the previous generation-FA/O I chelating agent researched before. Without an unstable oxidant agent added in the polishing slurry, it is difficult to enhance the copper polishing rate during the barrier CMP. The stronger chelating ability of the new chelating agent could increase the copper polishing rate along with controlling the Cu/Ta/TEOS removal rate selectivity to meet the requirements of the IC fabrication process. Thus it has solved the problem of excessive roughness due to the lower polishing rate, avoiding reducing the device performance with the pattern wafer. The new chelating agent with its lower p H value could make it possible to protect the low-k dielectric under the barrier layer from structurally breaking. The CMP experiment was performed on the 12 inch MIT 854 pattern wafers with the barrier slurry containing the new weakly alkaline chelating agent. By the DOE optimization, the results indicate that as the new chelating agent concentration in the slurry was up to 2.5 m L/L, the copper polishing rate is about 31.082 nm/min.Meanwhile, the wafer surface has a rather low roughness value of 0.693 nm(10×10 μm), the correction ability with the above slurry is adapted to the next generation barrier CMP and the k value of the low-k dielectric seems to have no k-shift. All the results presented show that the new weakly alkaline chelating agent with its superior performance can be used for the advanced barrier CMP.展开更多
基金Supported by Youth Fund of National Natural Science Foundation of China(31801673)Talent Development Fund of Anhui Academy of Agricultural Sciences(17F1205)+2 种基金Youth Innovation Fund of President of Anhui Academy of Agricultural Sciences(17B1220)Team Building Project of Anhui Academy of Agricultural Sciences(18C1225)Youth Fund of Natural Science Foundation of Anhui Province(1808085QC94)
文摘[Objectives]This study aimed to optimize the chelation process for complex microelement iron supplement derived from pig blood by response surface methodology.[Methods]On the basis of single-factor test,p H value,concentration of polypeptide solution and volume ratio of polypeptide solution to FeCl_2 solution were selected as influencing factors with Fe(II)chelation rate as the indicator for Box-Behnken central composite experimental design with three factors and three levels.The effects of three factors on the response value were analyzed by response surface methodology.[Results]The optimized chelation process for complex microelement iron supplement derived from pig blood by response surface methodology was as follows:pH 5.40,polypeptide solution concentration 2.27%,volume ratio of polypeptide solution to FeCl_2 solution 2.16∶1.Under this condition,the predictive Fe(II)chelation rate of iron supplement was 79.37%,while the actual value was 79.41%.[Conclusions]The optimized process may provide new thoughts for the development and utilization of complex microelement iron supplement derived from pig blood.
基金Project supported by the Special Project Items No.2 in National Long-Term Technology Development Plan,China(No.2009ZX02308)the Natural Science Foundation of Hebei Province,China(No.E2014202147)
文摘To strengthen the device performance with the pattern wafer by enhancing the Cu polishing rate and improve the surface roughness with the Cu lines, a new weakly alkaline chelating agent with a barrier slurry is developed to meet the process demand of the advanced barrier chemical mechanical planarization(CMP). This new chelating agent has a stronger chelating ability and a lower p H value than the previous generation-FA/O I chelating agent researched before. Without an unstable oxidant agent added in the polishing slurry, it is difficult to enhance the copper polishing rate during the barrier CMP. The stronger chelating ability of the new chelating agent could increase the copper polishing rate along with controlling the Cu/Ta/TEOS removal rate selectivity to meet the requirements of the IC fabrication process. Thus it has solved the problem of excessive roughness due to the lower polishing rate, avoiding reducing the device performance with the pattern wafer. The new chelating agent with its lower p H value could make it possible to protect the low-k dielectric under the barrier layer from structurally breaking. The CMP experiment was performed on the 12 inch MIT 854 pattern wafers with the barrier slurry containing the new weakly alkaline chelating agent. By the DOE optimization, the results indicate that as the new chelating agent concentration in the slurry was up to 2.5 m L/L, the copper polishing rate is about 31.082 nm/min.Meanwhile, the wafer surface has a rather low roughness value of 0.693 nm(10×10 μm), the correction ability with the above slurry is adapted to the next generation barrier CMP and the k value of the low-k dielectric seems to have no k-shift. All the results presented show that the new weakly alkaline chelating agent with its superior performance can be used for the advanced barrier CMP.