Optimal Operation Strategies for a Large Multi-Chiller System Based on Cooling Load Forecast
1
作者 Yanyue Lu Junghui Chen Yuanbin Mo 《Journal of Software Engineering and Applications》 2019年第12期540-561,共22页
In semiconductor and electronics factories, large multi-chiller systems are needed to satisfy strict cooling load requirements. In order to save energy, it is worthwhile to design the chilled water system operation. I... In semiconductor and electronics factories, large multi-chiller systems are needed to satisfy strict cooling load requirements. In order to save energy, it is worthwhile to design the chilled water system operation. In this paper, an optimal flexible operation scheme is developed based on a two-dimensional time-series model to forecast the cooling load of multi-chiller systems with chiller units of different cooling capacities running in parallel. The optimal integrity scheme can be obtained using the Mixed Integer Nonlinear Programming method, which minimizes the energy consumption of the system within a future time period. In order to better adapt the change of cooling load, the operation strategy of regulating the chilled water flowrates is employed. The chilled water flowrates are set as a design variable. When the chillers are running, their chilled water flowrates can vary within limits, whereas the flowrates are zero when the chillers are unloaded. This forecasting method provides integral optimization within a future time period and offers the operating reference for operators. The power and advantages of the proposed method are presented using an industrial case to help readers delve into this matter. 展开更多
关键词 LARGE Multi-chiller system Operation STRATEGIES Cooling Load FORECAST Energy Saving Optimal Design
下载PDF
Modelling of Chillers for Energy Performance Assessment of HVAC Systems
2
作者 Luigi Schibuola Massimiliano Scarpa Chiara Tambani 《Journal of Energy and Power Engineering》 2014年第6期1012-1020,共9页
The reliable assessment of the annual energy demand has become necessary in view of building energy performance certification. Accurate models must be used to simulate the behaviour of HVAC (heating, ventilation and ... The reliable assessment of the annual energy demand has become necessary in view of building energy performance certification. Accurate models must be used to simulate the behaviour of HVAC (heating, ventilation and air conditioning) components in real operation, usually characterized by a wide variation of building loads. In this context, this paper deals with the development and validation of an algorithm aimed at the assessment of part load performance of various kinds of controls for vapour compresion based heat pumps and chillers, in particular referring to on-off, inverter-driven and multi-stage vapour compression. The reliability of this algorithm in the calculation of seasonal performances is checked against monitoring of heat pumps and chillers operating under real conditions. 展开更多
关键词 MODELLING chiller part load energy performance building certification.
下载PDF
Performance of a Solar-Biomass Adsorption Chiller
3
作者 Najeh Ghilen Mohammed El Ganaoui +1 位作者 Slimane Gabsi Riad Benelmir 《Fluid Dynamics & Materials Processing》 EI 2023年第4期1015-1026,共12页
A dynamic model is presented for a chiller working with a composite adsorbent(silica activated carbon/CaCl2)–water pair in a solar-biomass cooling installation.The main objective is determining a link between two pos... A dynamic model is presented for a chiller working with a composite adsorbent(silica activated carbon/CaCl2)–water pair in a solar-biomass cooling installation.The main objective is determining a link between two possible evaporator configurations and the refrigerator’s performances.The two considered evaporators work at different pressure levels.The related time evolution profiles of temperature,pressure and water content are studied.Moreover,the effects of hot water inlet temperature and cooling water inlet temperature on the specific cooling capacity(SCP)and coefficient of performance(COP)are predicted by means of numerical simulations.The results show that an increase in the temperature of hot water and a decrease in the temperature of the cooling water allow an increase in COP and SCP.In particular,for a hot water inlet temperature of 85°C and a cooling water inlet temperature of 40°C,the COP and Qev are 0.67 and 4.3 kW,respectively. 展开更多
关键词 Adsorption chiller SOLAR BIOMASS PERFORMANCE
下载PDF
Optimization of Chiller Loading Problem Using Improved Golden Jackal Optimization Algorithm Leads to Reduction in Energy Consumption
4
作者 Na Dong Xiao Yang Nasser Yousefi 《Energy Engineering》 EI 2023年第11期2565-2583,共19页
This paper proposes a modified golden jackal optimization(IGJO)algorithm to solve the OCL(which stands for optimal cooling load)problem to minimize energy consumption.In this algorithm,many tools have been developed,s... This paper proposes a modified golden jackal optimization(IGJO)algorithm to solve the OCL(which stands for optimal cooling load)problem to minimize energy consumption.In this algorithm,many tools have been developed,such as numerical visualization,local field method,competitive selectionmethod,and iterative strategy.The IGJO algorithm is used to improve the research capabilities of the algorithm in terms of global tuning and rotation speed.In order to fully utilize the effectiveness of the proposed algorithm,three famous examples of OCL problems in basic ventilation systems were studied and compared with some previously published works.The results show that the IGJO algorithm can find solutions equal to or better than other methods.Underpinning these studies is the need to reduce energy consumption in air conditioning systems,which is a critical business and environmental decision.The Optimal Chiller Load(OCL)problem is well-known in the industry.It is the best method of operation for the refrigeration plant to satisfy the requirement of cooling.In order to solve the OCL problem,an improved Golden Jackal optimization algorithm(IGJO)was proposed.The IGJO algorithm consists of a number of parts to improve the global optimization and rotation speed.These studies are intended to address more effectively the issue of OCL,which results in energy savings in air-conditioning systems.The performance of the proposed IGJO algorithm is evaluated,and the results are compared with the results of three known OCL problems in the ventilation system.The results indicate that the IGJO method has the same or better optimization ability as other methods and can improve the energy efficiency of the system’s cold air. 展开更多
关键词 Optimal chiller loading improved version of golden jackal optimization energy consumption
下载PDF
Impact of Numerous Beds Operating Conditions for Enhancing the Performance of a Solar Heat-Supported Adsorption Chiller
5
作者 Nusrat Jahan M. Abdul Hakim Khan K. M. Ariful Kabir 《Journal of Applied Mathematics and Physics》 2023年第11期3651-3665,共15页
Thermal adsorption cooling systems have gained significant attention due to their potential for energy savings and eco-environmental impact. An analytic investigation of the heat transfer inside an adsorption chiller ... Thermal adsorption cooling systems have gained significant attention due to their potential for energy savings and eco-environmental impact. An analytic investigation of the heat transfer inside an adsorption chiller with various bed silica gel-water pairs is presented. A comprehensive model has been designed to accurately predict the correlation between the overall performance of the proposed chiller system and the functional and structural condition of the building. This model takes into account various factors such as temperature, humidity, and air quality to provide a detailed analysis of the system’s efficiency. At least 20 collectors consisting of a 34.4 m area (each) with a full-cycle time of 480 seconds are essential to improper run conditions. It is necessary to adjust the optimum cycle time for optimal performance. During the investigation, the base condition shows that the cooling capacity is 14 kw, 0.6 COPcycle, and 0.35 COPsolar at noon. Also, conduct a thorough investigation into the chiller’s performance under varying cooling water supply temperatures and various chilled water flow rates. 展开更多
关键词 Adsorption chillers Adsorption Cooling Multiple Adsorption Beds Solar Heat
下载PDF
机场航站楼空调冷水机组设计选型方法研究:以我国夏热冬暖地区一枢纽机场航站楼为例
6
作者 温嘉权 何花 +2 位作者 李哲青 叶翠 邓杰文 《暖通空调》 2024年第1期89-94,共6页
空调系统合理设计与高效运行是机场航站楼节能降耗的关键环节。而冷水机组作为空调冷源系统的核心设备,在设计阶段如何根据项目供冷需求,合理设置冷水机组台数与容量搭配,是实现其供冷季变工况高效运行的重要保障。本文以我国夏热冬暖... 空调系统合理设计与高效运行是机场航站楼节能降耗的关键环节。而冷水机组作为空调冷源系统的核心设备,在设计阶段如何根据项目供冷需求,合理设置冷水机组台数与容量搭配,是实现其供冷季变工况高效运行的重要保障。本文以我国夏热冬暖地区一新建枢纽机场航站楼为例,对其冷水机组设计选型方法展开深入研究和案例分析,以期对同类型交通枢纽建筑空调系统优化设计提供参考,推动交通枢纽建筑节能减排工作。 展开更多
关键词 机场航站楼 空调系统 冷水机组 模拟分析 节能优化
下载PDF
Performance analysis on a novel water chiller using liquid desiccant
7
作者 曹熔泉 张小松 殷勇高 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期192-196,共5页
A new type of liquid desiccant water chiller for applications on air-conditioning and refrigeration is introduced.The system can be driven by low-grade heat sources with temperatures of 60 to 80 ℃,which can be easily... A new type of liquid desiccant water chiller for applications on air-conditioning and refrigeration is introduced.The system can be driven by low-grade heat sources with temperatures of 60 to 80 ℃,which can be easily obtained by a flat plat solar collector,waste heat,etc.A numerical model is developed to study the system performance.The effects of different parameters on performance are discussed,including evaporating temperature,regenerating temperature,ambient condition,and mass flow rates of closed moist air and regenerating air.The results show that an acceptable performance of a cooling capacity of 2.5 kW and a coefficient of performance of 0.37 can be achieved in a reference case.The regenerating temperature and the humidity ratios of ambient air are two main factors affecting system performance,while the temperature of ambient air functions less.In addition,the mass flow rate of regenerating air and closed moist air should be carefully determined for economical operation. 展开更多
关键词 liquid desiccant water chiller coefficient of perfor-mance low-grade energy utilization
下载PDF
团体标准T/CRAAS1039-2023(T/CECA20026-2023)《高效空调制冷机房系统能效监测与分级标准》解析
8
作者 张小梅 胡永胜 戎晔 《制冷与空调》 2024年第8期7-11,共5页
介绍了团体标准T/CRAAS1039—2023(T/CECA20026—2023)《高效空调制冷机房系统能效监测与分级标准》中高效空调制冷机房系统的术语、基本规定、监测、能效分级等,为相关的工程技术人员正确理解并执行该标准提供了参考。
关键词 空调制冷机房系统 高效空调制冷机房系统 全年运行能效比
下载PDF
一机一泵组合的冷却水泵工作区与变频运行分析 被引量:1
9
作者 旷金国 王朝晖 +2 位作者 罗曙光 陈盛阶 叶圳 《暖通空调》 2024年第1期119-124,156,共7页
根据深圳前海10号制冷站区域供冷系统,建立了一机一泵组合的冷却水系统水力计算模型,包括共享的总管+冷却塔压降模型,以及各支路的压降模型。针对不同运行模式,得到了水泵工作区;结合水泵变频特性曲线,得到了每个水泵工作区不同流量对... 根据深圳前海10号制冷站区域供冷系统,建立了一机一泵组合的冷却水系统水力计算模型,包括共享的总管+冷却塔压降模型,以及各支路的压降模型。针对不同运行模式,得到了水泵工作区;结合水泵变频特性曲线,得到了每个水泵工作区不同流量对应的水泵运行频率范围,可用于水泵变频控制,简化水泵运行控制策略。本文提出的水泵工作区还可用于水泵选型,校核水泵在所有工况是否运行在高效区。 展开更多
关键词 区域供冷系统 一机一泵组合 水力计算模型 水泵工作区 水泵运行频率范围 水泵选型
下载PDF
机场航站楼空调水系统深化设计方法与案例研究
10
作者 李哲青 温嘉权 +2 位作者 沈浩 邓杰文 廖展浩 《制冷与空调》 2024年第6期55-61,共7页
为实现中国民航业的绿色可持续发展,中国政府提出了打造绿色低碳航空、提高服务保障能力、推进技术进步和节能减排等要求,对中央空调系统能效有更高的要求。对于新建航站楼,通过节能措施提升系统的整体能效是关键所在。文章以我国夏热... 为实现中国民航业的绿色可持续发展,中国政府提出了打造绿色低碳航空、提高服务保障能力、推进技术进步和节能减排等要求,对中央空调系统能效有更高的要求。对于新建航站楼,通过节能措施提升系统的整体能效是关键所在。文章以我国夏热冬暖地区枢纽机场航站楼为例,主要从中央空调系统的水系统方面开展研究,开展能效分析,提出节能措施,既为新航站楼中央空调的建设提供参考依据,又为现有航站楼中央空调系统的改造提供数据支持。 展开更多
关键词 机场航站楼 空调系统 能效优化 节能 高效机房
下载PDF
Optimum control strategy for all-variable speed chiller plant 被引量:2
11
作者 蒋小强 龙惟定 李敏 《Journal of Central South University》 SCIE EI CAS 2011年第2期573-579,共7页
The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation ... The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant. 展开更多
关键词 chiller plant control strategy variable speed cooling water flow rate chilled water flow rate
下载PDF
Chiller faults detection and diagnosis with sensor network and adaptive 1D CNN 被引量:2
12
作者 Ke Yan Xiaokang Zhou 《Digital Communications and Networks》 SCIE CSCD 2022年第4期531-539,共9页
Computer-empowered detection of possible faults for Heating,Ventilation and Air-Conditioning(HVAC)subsystems,e.g.,chillers,is one of the most important applications in Artificial Intelligence(AI)integrated Internet of... Computer-empowered detection of possible faults for Heating,Ventilation and Air-Conditioning(HVAC)subsystems,e.g.,chillers,is one of the most important applications in Artificial Intelligence(AI)integrated Internet of Things(IoT).The cyber-physical system greatly enhances the safety and security of the working facilities,reducing time,saving energy and protecting humans’health.Under the current trends of smart building design and energy management optimization,Automated Fault Detection and Diagnosis(AFDD)of chillers integrated with IoT is highly demanded.Recent studies show that standard machine learning techniques,such as Principal Component Analysis(PCA),Support Vector Machine(SVM)and tree-structure-based algorithms,are useful in capturing various chiller faults with high accuracy rates.With the fast development of deep learning technology,Convolutional Neural Networks(CNNs)have been widely and successfully applied to various fields.However,for chiller AFDD,few existing works are adopting CNN and its extensions in the feature extraction and classification processes.In this study,we propose to perform chiller FDD using a CNN-based approach.The proposed approach has two distinct advantages over existing machine learning-based chiller AFDD methods.First,the CNN-based approach does not require the feature selection/extraction process.Since CNN is reputable with its feature extraction capability,the feature extraction and classification processes are merged,leading to a more neat AFDD framework compared to traditional approaches.Second,the classification accuracy is significantly improved compared to traditional methods using the CNN-based approach. 展开更多
关键词 chiller Fault detection and diagnosis Deep learning neural network Long short term memory Recurrent neural network Gated recurrent unit
下载PDF
Study on Buildings CCHP System Based on SOFC 被引量:1
13
作者 Bin Zhang Yongzhen Wang +1 位作者 Jiaqing Zheng Dan Liu 《Fluid Dynamics & Materials Processing》 EI 2020年第3期665-674,共10页
The relationship among the working temperature,pressure and current density of a Solid oxide fuel cell(SOFC)and its output power and efficiency are analyzed in the framework of a theoretical model able to provide,amon... The relationship among the working temperature,pressure and current density of a Solid oxide fuel cell(SOFC)and its output power and efficiency are analyzed in the framework of a theoretical model able to provide,among other things,the volt ampere characteristic curve.In particular,following the principle of temperature matching and cascade utilization,we consider a gas turbine(GT)and a LiBr absorption chiller to recycle the high-grade exhaust heat produced by the considered SOFC.This distributed total energy system is set up with the intent to meet typical needs of buildings for cooling,heating and power(CCHP).The total power generated by the considered SOFC and gas turbine is about 222 kW and the total power generation efficiency by low heat value of fuel(LHV)is 63.7%.In the CCHP system,the high temperature exhaust of GT is further used to drive LiBr absorption unit,which can produce about 34.8 kW cooling capacity or 84.5 kW of heat(the total energy utilization 78.03%). 展开更多
关键词 SOFC gas turbine absorption chiller CCHP total energy system
下载PDF
Possibilities of Using Solar Energy in District Cooling Systems in the Mediterranean Region 被引量:3
14
作者 John Vourdoubas 《Open Journal of Energy Efficiency》 2019年第2期21-34,共14页
Use of district heating and cooling systems has many environmental advantages compared to individual heating and cooling. Recent advances in solar energy technologies for heat and power generation have reduced their c... Use of district heating and cooling systems has many environmental advantages compared to individual heating and cooling. Recent advances in solar energy technologies for heat and power generation have reduced their cost and promoted their use instead of fossil fuels. Solar-PV energy for electricity generation and solar thermal energy for hot water production are broadly used today. Solar energy resources in the Mediterranean region are abundant while space cooling in buildings is required when solar irradiance is high. The possibility of using solar energy for fuelling water chillers providing cold water in district cooling systems in the Mediterranean basin has been investigated. Existing literature and studies concerning the use of district cooling systems globally as well as the energy sources used in them have been examined. Solar-PV energy combined with compression chillers and solar thermal energy combined with thermally driven chillers can be used for cold water production. Their overall efficiencies, converting solar energy to cold water, vary between 22% and 56% compared with 45% for compression chillers using grid electricity. It is concluded that various solar energy technologies could be used with different types of water chillers for fuelling district cooling networks in the future in the Mediterranean region. 展开更多
关键词 DISTRICT COOLING EFFICIENCY Mediterranean REGION SOLAR Energy Water chillers
下载PDF
Thermodynamic and Experimental Analysis of an Ammonia-Water Absorption Chiller 被引量:1
15
作者 Dingfeng Kong Jianhua Liu +2 位作者 Liang Zhang Hang He Zhiyun Fang 《Energy and Power Engineering》 2010年第4期298-305,共8页
A single stage ammonia-water absorption chiller with complete condensation is designed, built and tested. The apparatus is designed for a cooling capacity of 2814 W, which is obtained using electric heater as heating ... A single stage ammonia-water absorption chiller with complete condensation is designed, built and tested. The apparatus is designed for a cooling capacity of 2814 W, which is obtained using electric heater as heating source. The thermodynamic models have been derived using the First and Second Laws. Calculated results are compared with experimental data. The results show that the cooling capacity of experimental apparatus is found between 1900 and 2200 W with the actual coefficient of performance (COP) between 0.32 and 0.36. The contribution of the components to internal entropy production is analyzed. It shows that the larger irreversibility is caused by spanning the largest temperature and dissipated thermal energy by heat transfer losses at the generator and evaporator. In the experimentation, the low pressure is lower than the designed value. This is a consequence of a large capacity in the falling film absorber which performs as expected. This decreases the evaporation pressure, and the evaporating temperature could be reduced to the designed value. 展开更多
关键词 ABSORPTION chiller AMMONIA-WATER THERMODYNAMIC MODELING EXPERIMENTAL Performance
下载PDF
Energy, Exergy and Thermoeconomics Analysis of Water Chiller Cooler for Gas Turbines Intake Air Cooling 被引量:1
16
作者 Galal Mohammed Zaki Rahim Kadhim Jassim Majed Moalla Alhazmy 《Smart Grid and Renewable Energy》 2011年第3期190-205,共16页
Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the... Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the compressor has been widely used to mitigate this shortcoming. Energy and exergy analysis of a GT Brayton cycle coupled to a refrigeration air cooling unit shows a promise for increasing the output power with a little decrease in thermal efficiency. A thermo-economics algorithm is developed to estimate the economic feasibility of the cooling system. The analysis is applied to an open cycle, HITACHI-FS7001B GT plant at the industrial city of Yanbu (Latitude 24o 05” N and longitude 38o E) by the Red Sea in the Kingdom of Saudi Arabia. Result show that the enhancement in output power depends on the degree of chilling the air intake to the compressor (a 12 - 22 K decrease is achieved). For this case study, maximum power gain ratio (PGR) is 15.46% (average of 12.25%), at an insignificant decrease in thermal efficiency. The second law analysis show that the exergetic power gain ratio drops to an average 8.5%. The cost of adding the air cooling system is also investigated and a cost function is derived that incorporates time-dependent meteorological data, operation characteristics of the GT and the air intake cooling system and other relevant parameters such as interest rate, lifetime, and operation and maintenance costs. The profit of adding the air cooling system is calculated for different electricity tariff. 展开更多
关键词 Gas Turbine EXERGY Analysis Power BOOSTING Hot Climate Air Cooling Water chiller
下载PDF
基于成都某金融建筑浅析串联式主机上游冰蓄冷系统设计
17
作者 武佳琛 《洁净与空调技术》 2024年第1期70-74,共5页
以成都某金融建筑冰蓄冷空调系统为例,展开分析了串联式主机上游冰蓄冷系统的整体设计思路和流程,着重探讨了冰蓄冷系统双工况冷水机组的选型方法、乙二醇侧温度设计以及板式换热器选型,梳理归纳了冰蓄冷系统简要设计流程图,可为相关设... 以成都某金融建筑冰蓄冷空调系统为例,展开分析了串联式主机上游冰蓄冷系统的整体设计思路和流程,着重探讨了冰蓄冷系统双工况冷水机组的选型方法、乙二醇侧温度设计以及板式换热器选型,梳理归纳了冰蓄冷系统简要设计流程图,可为相关设计提供借鉴。 展开更多
关键词 冰蓄冷系统 双工况冷水机组选型 运行策略 经济技术分析 设计流程
下载PDF
Energy Performance Analysis of Ice Thermal Storage for Commercial HVAC Systems 被引量:1
18
作者 Nabil Nassif Raymond Tesiero Nihal AI Raees 《Journal of Energy and Power Engineering》 2013年第9期1713-1718,共6页
Ice thermal storage is a promising technology to reduce energy costs by shifting the cooling cost from on-peak to off-peak periods. The paper investigates the application of ice thermal storage and its impact on energ... Ice thermal storage is a promising technology to reduce energy costs by shifting the cooling cost from on-peak to off-peak periods. The paper investigates the application of ice thermal storage and its impact on energy consumption, demand and total energy cost. Energy simulation software along with a chiller model is used to simulate the energy consumption and demand for the existing office building located in central Florida. Furthermore, the study presents a case study to demonstrate the cost saving achieved by the ice storage applications. The results show that although the energy consumption may increase by using ice thermal storage, the energy cost drops significantly, mainly depending on the local utility rate structure. It found that for the investigated system the annual energy consumption increases by about 12% but the annual energy cost drops by about 3 6%. 展开更多
关键词 HVAC system ice thermal storage central plant chiller.
下载PDF
Condensing Heat Recovery of Centrifugal Chiller
19
作者 GONG Guang-cai,JIAO Jun-jun,WANG Li-ping,ZENG Wei(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期123-126,共4页
To a kind of centrifugal water chiller with R22 and about 1 745 kW of cooling capacity,a heat exchanger was added between the outlet of compressor and original condenser to get part of or all the condensing heat.Conde... To a kind of centrifugal water chiller with R22 and about 1 745 kW of cooling capacity,a heat exchanger was added between the outlet of compressor and original condenser to get part of or all the condensing heat.Condensing heat can be recovered by compound condensing method,which adopts air-cooling model +water-cooling model or water-cooling model +water-cooling model at the condensing side of the system.By exergy analysis and experiment research on compound condensing heat recovery of centrifugal chiller,the results are obtained that the capability of the whole system increases,the energy efficiency ratio(EER)becomes 3.2~5.0 from 2.2~3.4,which implies the EER increases about 1.0~1.5,the exergy efficiency increases about 10%,and the chiller runs more stably after reformation. 展开更多
关键词 CENTRIFUGAL chiller condensing HEAT RECOVERY COMPOUND condensing method EER
下载PDF
Dynamic Performance of On-off Operation for a Small Scale Direct Fired Absorption Chiller
20
作者 Wang Lei(王磊) +1 位作者 Lu Zhen(陆震) 《Journal of Donghua University(English Edition)》 EI CAS 2001年第1期46-50,共5页
A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship betwe... A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio. 展开更多
关键词 DIRECT fired ABSORPTION chiller part load DYNAMIC performance.
下载PDF