An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte...An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.展开更多
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s...A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.展开更多
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ...To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.展开更多
[Objectives]To establish an ultra performance convergence chromatography(UPC2)method to determine the content of enantiomers in(R)-2-methoxyethyl1-(1-phenylethyl)-1H-imidazole-5-carboxylate hydrochloride(ET-26 HCl).[M...[Objectives]To establish an ultra performance convergence chromatography(UPC2)method to determine the content of enantiomers in(R)-2-methoxyethyl1-(1-phenylethyl)-1H-imidazole-5-carboxylate hydrochloride(ET-26 HCl).[Methods]ChiralpakAD-3 chromatographic column(4.6 mm×100 mm,3μm)was used,with 0.1%diethylamine methanol solution-supercritical carbon dioxide(1∶9)as mobile phase;flow rate 2.0 mL/min;back pressure 2000 psi,detection wavelength 240 nm,and column temperature 35℃.[Results]ET-26-HCl was completely separated from the enantiomers,and the linear relationship was good;the detection limit was 1.5μg/mL.[Conclusions]This method is suitable for the determination of the content of enantiomers in ET-26-HCl.展开更多
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc...In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.展开更多
A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxyte...A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.展开更多
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a...The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection.展开更多
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c...[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.展开更多
An efficient and environment-friendly method for simultaneous determination of 13 typical derivatives of polycyclic aromatic hydrocarbon(PAH)in petroleum-polluted soil with nitro-,oxy-and alkylfunctional group was dev...An efficient and environment-friendly method for simultaneous determination of 13 typical derivatives of polycyclic aromatic hydrocarbon(PAH)in petroleum-polluted soil with nitro-,oxy-and alkylfunctional group was developed using supercritical fluid extraction(SFE)followed by ultra-high performance supercritical fluid chromatography(UHPSFC).Parameters of UHPSFC,including type of stationary phase and mobile phase modifiers,gradient elution process,backpressure,column temperature,and the flow rate of mobile phase,were systematically optimized,achieving a fast separation within4.2 min.Limits of detection(LOD)were 0.005-0.1μg mL^(-1)or 0.1-2.0 ng g^(-1),respectively,with a good repeatability(RSD<5.0%).Before UHPSFC-PDA analysis,the PAH-derivatives in soil samples were effectively enriched in 15.0 min using SFE with an online carbon nanotubes(CNTs)collection trap.The soil samples were analyzed by the proposed method and the results were verified by GC-MS.Thus,SFE equipped with an online CNTs trap followed by UHPSFC-PDA analysis,which only consumed about2.0 mL organic solvent for a whole run,has been demonstrated to be an efficient way for screening and quantitative analysis of trace-level PAH-derivatives in soil samples.展开更多
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl...This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.展开更多
In this study, a new technique was developed using rapid ultra-performance liquid chromatography (UPLC)-based separation coupled with electrochemical detection by a boron-doped diamond (BDD) electrode for the detectio...In this study, a new technique was developed using rapid ultra-performance liquid chromatography (UPLC)-based separation coupled with electrochemical detection by a boron-doped diamond (BDD) electrode for the detection and quantification of three commonly used parabens (methylparaben (MP), ethylparaben (EP) and propylparaben (PP)). We aimed to reduce the analysis time by using UPLC coupled with a short reverse phase C 18 monolithic column (25 mm×4.6 mm). Operating the monolithic column at low back-pressure resulted in high flow rates. A mobile phaseconsisting of a 25:75 (v/v) ratio of acetonitrile:0.05 Mphosphate buffer (pH 5) at a flow rate of 2.5 mL·min?1 was used to perform the separation. The amperometric detection with the BDD electrode was found to be optimal and reliably reproducible at a detection potential of 1.5 V vs. Ag/AgCl. Under these conditions, the separation of the three targetanalytes (MP, EP and PP) was achieved in 2 min and was linear within a sample concentration range of 0.1 to 50.0 mg·L?1 (r2 values of 0.9970, 0.9994 and 0.9994 for MP, EP and PP, respectively). This method was successfully applied to determine the concentrations of each parabeninsix real samples with therecoveries ranging from of 80.3% - 98.9% for all three parabensfrom samples spiked at 12, 22 and 32 mg·L?1. Therefore, the proposed method can be used as an alternative rapid and selective method for the determination of paraben levels in real samples.展开更多
Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In t...Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In this paper,a rapid and quantitative ultra-high performance liquid chromatography tandem mass spectrometry(UHPLCMS/MS)method was established for determination of macromolecular biosynthesis substrate(dimethylallyl pyrophosphate,DMAPP)and initiator(farnesyl pyrophosphate,FPP)contained in TKS.A Kromasil C18 chromatographic column was used for separation,and the multi-reaction monitoring mode(MRM)of triple quadrupole mass spectrometry was used for detection.Quantification was performed by external calibration method.The results showed that the limit of detection(LOD)and the limit of quantitation(LOQ)of DMAPP were 2.42μg/L and 7.26μg/L,respectively,and the LOQ and the LOD of FPP were 1.02μg/L and 3.05μg/L,respectively.At a concentration of 1—1000μg/L,both analytes had good determination coefficients(>0.999)of calibration curve.The recoveries of DMAPP and FPP were between 99.0%and 117.1%.In real samples detection,the contents of DMAPP and FPP in TKS samples were between 23.32—82.77μg/L and 12.03—85.67μg/L,respectively.Thus,this approach is a reliable method to quantify DMAPP and FPP in TKS.展开更多
The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a co...The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a cough and asthma relieving agent.Herein,a dimension-enhanced integral approach,by combining ultra-high performance liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(UHPLC/IMQTOF-MS)and intelligent peak annotation,was developed to rapidly characterize the multicomponents from SDS.Good chromatographic separation was achieved within 38 min on a UPLC CSH C18(2.1×100 mm,1.7μm)column which was eluted by 0.1%formic acid in water(water phase)and acetonitrile(organic phase).Collision-induced dissociation-MS^(2)data were acquired by the data-independent high-definition MS^(E)(HDMS^(E))in both the negative and positive electrospray ionization modes.A major components knockout strategy was applied to improve the characterization of those minor ingredients by enhancing the injection volume.Moreover,a self-built chemistry library was established,which could be matched by the UNIFI software enabling automatic peak annotation of the obtained HDMS^(E)data.As a result of applying the intelligent peak annotation workflows and further confirmation process,a total of 53 compounds were identified or tentatively characterized from the SDS,including 29 flavonoids,one uridine derivative,four glucosides,one lignin,one phenolic compound,and 17 others.Notably,four-dimensional information related to the structure(e.g.,retention time,collision cross section,MS^(1)and MS^(2)data)was obtained for each component by the developed integral approach,and the results would greatly benefit the quality control of SDS.展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra ...Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra high performance liquid chromatography (UHPLC) and turbulent flow chromatography, an alternative fully automated process allowing analyte’s extraction. Methods: A new radiotracer for dopamine transporter imaging, namely LBT-999, was used to demonstrate the method’s robustness. Matrix effect, Turboflow column loading, linearity, specificity and precision were evaluated with in vitro samples of LBT-999 in human plasma. Radiodetector sensitivity and preliminary evaluation were respectively determined by analysis of calibrated samples of [18F]LBT-999 and blood samples from 4 healthy subjects injected with [18F]LBT-999, withdrawn at 5, 15, 30 and 45 min pi. Results: With three sequential loadings (3 × 100 μL) of the Turboflow column, mean coefficients of variation were 1%, below 2%, 2% and 30.9% for matrix effect, specificity, repeatability and intermediate precision, respectively. Correlation coefficients for linearity were superior to 0.97. Limits of detection and quantification of the radiodetector were fixed at 3 and 9 c/s. Retention times for [18F]LBT-999 and the two radiometabolites detected by radio-UHPLC were 6.5, 4.8 and 9.6 min. Forty-five min after the injection, parent fraction was still predominant with 57.8% ± 25% of the total radioactivity. Conclusions: An innovative approach, allying UHPLC and Turboflow column, was developed and its sensitivity, linearity, specificity and repeatability validated. Preliminary results of the clinical trial are in accordance with literature data, demonstrating its efficiency in radiometabolites quantification.展开更多
A highly sensitive, selective, and precise ultra-performance liquid chromatography tandem mass spectrometry method was developed and validated for simultaneous quantification of itraconazole and hydroxy itraconazole i...A highly sensitive, selective, and precise ultra-performance liquid chromatography tandem mass spectrometry method was developed and validated for simultaneous quantification of itraconazole and hydroxy itraconazole in human plasma by a single liquid-liquid extraction step. The precursor to product ion transitions of m/z 705.3/392.3, m/z 721.2/408.3 and m/z 708.2/435.4 were used to detect and quantify itraconazole, hydroxy itraconazole and itraconazole-d3 respectively. The lower limit of quantitation was found to be 0.500 ng/mL for itraconazole and 1.00 ng/mL for hydroxy itraconazole. The mean recoveries for itraconazole and hydroxy itraconazole were found to be 100.045% and 100.021%, respectively. This developed method with a chromatographic run time of 2.0 min was successfully applied to a bioequivalence study of 100 mg itraconazole capsule.展开更多
A rapid method was presented for the determination of 19 polyphenols in tea by ultra-high performance liquid chromatography coupled with quadrupole-time of flight mass spectrometry(UPLC-Q-TOF MS).Tea samples were extr...A rapid method was presented for the determination of 19 polyphenols in tea by ultra-high performance liquid chromatography coupled with quadrupole-time of flight mass spectrometry(UPLC-Q-TOF MS).Tea samples were extracted by 50%(V/V)ethanol,then separated by Waters Acquity BEH C18 column using a binary solvent system composed of acetonitrile and water(0.1%formic acid)by gradient elution.The analytes were determined by Q-TOF MS in TOF MS and information dependent acquisition(IDA)-MS/MS mode.The results showed that mass accuracy error of the 19 polyphenols were lower than 5.0×10^(-6),good linear relationship was got in range of 0.2–500μg/L and correlation coefficient was higher than 0.9990.The LOD was in the range of 0.002–0.100 mg/kg and the LOQ was in the range of 0.004–0.200 mg/kg.Recovery of the method was in range of 78.4%–109.2%with spike levels of 0.004–2.000 mg/kg,relative standard deviations were lower than 10%.The method was simple,rapid and accurate.It could be used for the rapid screening and quantitative analysis of 19 polyphenols in tea.展开更多
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC...Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.展开更多
Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients a...Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies.展开更多
文摘An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.
基金supported by the Natural Science Foundation of Zhejiang Province,China(No.LY17C200009)the Foundation of Zhejiang Educational Committee(No.Y201328477)
文摘A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.
基金supported by the Preventive medicine and public health research project of Anhui,China(No.2011Y0103)the Natural Science Foundation of Anhui,China(No.11040606M216)
文摘To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.
文摘[Objectives]To establish an ultra performance convergence chromatography(UPC2)method to determine the content of enantiomers in(R)-2-methoxyethyl1-(1-phenylethyl)-1H-imidazole-5-carboxylate hydrochloride(ET-26 HCl).[Methods]ChiralpakAD-3 chromatographic column(4.6 mm×100 mm,3μm)was used,with 0.1%diethylamine methanol solution-supercritical carbon dioxide(1∶9)as mobile phase;flow rate 2.0 mL/min;back pressure 2000 psi,detection wavelength 240 nm,and column temperature 35℃.[Results]ET-26-HCl was completely separated from the enantiomers,and the linear relationship was good;the detection limit was 1.5μg/mL.[Conclusions]This method is suitable for the determination of the content of enantiomers in ET-26-HCl.
文摘In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.
文摘A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
文摘The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection.
基金Supported by Key Scientific and Technological Research Project in Higher Education Institutions of Henan Province(17A350002)Project of National Natural Science Foundation of China(81172953)
文摘[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.
基金financially supported by the National Natural Science Foundation of China(No.21874153)Science Foundation of China University of Petroleum,Beijing(No.2462017BJB09)PetroChina Innovation Foundation(No.2016D-5007-0402)。
文摘An efficient and environment-friendly method for simultaneous determination of 13 typical derivatives of polycyclic aromatic hydrocarbon(PAH)in petroleum-polluted soil with nitro-,oxy-and alkylfunctional group was developed using supercritical fluid extraction(SFE)followed by ultra-high performance supercritical fluid chromatography(UHPSFC).Parameters of UHPSFC,including type of stationary phase and mobile phase modifiers,gradient elution process,backpressure,column temperature,and the flow rate of mobile phase,were systematically optimized,achieving a fast separation within4.2 min.Limits of detection(LOD)were 0.005-0.1μg mL^(-1)or 0.1-2.0 ng g^(-1),respectively,with a good repeatability(RSD<5.0%).Before UHPSFC-PDA analysis,the PAH-derivatives in soil samples were effectively enriched in 15.0 min using SFE with an online carbon nanotubes(CNTs)collection trap.The soil samples were analyzed by the proposed method and the results were verified by GC-MS.Thus,SFE equipped with an online CNTs trap followed by UHPSFC-PDA analysis,which only consumed about2.0 mL organic solvent for a whole run,has been demonstrated to be an efficient way for screening and quantitative analysis of trace-level PAH-derivatives in soil samples.
文摘This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.
文摘In this study, a new technique was developed using rapid ultra-performance liquid chromatography (UPLC)-based separation coupled with electrochemical detection by a boron-doped diamond (BDD) electrode for the detection and quantification of three commonly used parabens (methylparaben (MP), ethylparaben (EP) and propylparaben (PP)). We aimed to reduce the analysis time by using UPLC coupled with a short reverse phase C 18 monolithic column (25 mm×4.6 mm). Operating the monolithic column at low back-pressure resulted in high flow rates. A mobile phaseconsisting of a 25:75 (v/v) ratio of acetonitrile:0.05 Mphosphate buffer (pH 5) at a flow rate of 2.5 mL·min?1 was used to perform the separation. The amperometric detection with the BDD electrode was found to be optimal and reliably reproducible at a detection potential of 1.5 V vs. Ag/AgCl. Under these conditions, the separation of the three targetanalytes (MP, EP and PP) was achieved in 2 min and was linear within a sample concentration range of 0.1 to 50.0 mg·L?1 (r2 values of 0.9970, 0.9994 and 0.9994 for MP, EP and PP, respectively). This method was successfully applied to determine the concentrations of each parabeninsix real samples with therecoveries ranging from of 80.3% - 98.9% for all three parabensfrom samples spiked at 12, 22 and 32 mg·L?1. Therefore, the proposed method can be used as an alternative rapid and selective method for the determination of paraben levels in real samples.
基金the supports of the National Key Research and Development of BioBased Rubber(2017YFB0306900&2017YFB0306901)the National Natural Science Foundation of China(51673012)+1 种基金the Fundamental Research Funds for the Central Universities(PYBZ1828)the Beijing Technology and Business Universtiy Youth Scholoars Funds(PXM2019014213000007)。
文摘Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In this paper,a rapid and quantitative ultra-high performance liquid chromatography tandem mass spectrometry(UHPLCMS/MS)method was established for determination of macromolecular biosynthesis substrate(dimethylallyl pyrophosphate,DMAPP)and initiator(farnesyl pyrophosphate,FPP)contained in TKS.A Kromasil C18 chromatographic column was used for separation,and the multi-reaction monitoring mode(MRM)of triple quadrupole mass spectrometry was used for detection.Quantification was performed by external calibration method.The results showed that the limit of detection(LOD)and the limit of quantitation(LOQ)of DMAPP were 2.42μg/L and 7.26μg/L,respectively,and the LOQ and the LOD of FPP were 1.02μg/L and 3.05μg/L,respectively.At a concentration of 1—1000μg/L,both analytes had good determination coefficients(>0.999)of calibration curve.The recoveries of DMAPP and FPP were between 99.0%and 117.1%.In real samples detection,the contents of DMAPP and FPP in TKS samples were between 23.32—82.77μg/L and 12.03—85.67μg/L,respectively.Thus,this approach is a reliable method to quantify DMAPP and FPP in TKS.
基金This work was financially supported by the National Key Research and Development Program of China(Grant No.2018YFC1704500)Tianjin Committee of Science and Technology of China(Grant No.21ZYJDJC00080)National Natural Science Foundation of China(Grant No.81872996).
文摘The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a cough and asthma relieving agent.Herein,a dimension-enhanced integral approach,by combining ultra-high performance liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(UHPLC/IMQTOF-MS)and intelligent peak annotation,was developed to rapidly characterize the multicomponents from SDS.Good chromatographic separation was achieved within 38 min on a UPLC CSH C18(2.1×100 mm,1.7μm)column which was eluted by 0.1%formic acid in water(water phase)and acetonitrile(organic phase).Collision-induced dissociation-MS^(2)data were acquired by the data-independent high-definition MS^(E)(HDMS^(E))in both the negative and positive electrospray ionization modes.A major components knockout strategy was applied to improve the characterization of those minor ingredients by enhancing the injection volume.Moreover,a self-built chemistry library was established,which could be matched by the UNIFI software enabling automatic peak annotation of the obtained HDMS^(E)data.As a result of applying the intelligent peak annotation workflows and further confirmation process,a total of 53 compounds were identified or tentatively characterized from the SDS,including 29 flavonoids,one uridine derivative,four glucosides,one lignin,one phenolic compound,and 17 others.Notably,four-dimensional information related to the structure(e.g.,retention time,collision cross section,MS^(1)and MS^(2)data)was obtained for each component by the developed integral approach,and the results would greatly benefit the quality control of SDS.
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.
文摘Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra high performance liquid chromatography (UHPLC) and turbulent flow chromatography, an alternative fully automated process allowing analyte’s extraction. Methods: A new radiotracer for dopamine transporter imaging, namely LBT-999, was used to demonstrate the method’s robustness. Matrix effect, Turboflow column loading, linearity, specificity and precision were evaluated with in vitro samples of LBT-999 in human plasma. Radiodetector sensitivity and preliminary evaluation were respectively determined by analysis of calibrated samples of [18F]LBT-999 and blood samples from 4 healthy subjects injected with [18F]LBT-999, withdrawn at 5, 15, 30 and 45 min pi. Results: With three sequential loadings (3 × 100 μL) of the Turboflow column, mean coefficients of variation were 1%, below 2%, 2% and 30.9% for matrix effect, specificity, repeatability and intermediate precision, respectively. Correlation coefficients for linearity were superior to 0.97. Limits of detection and quantification of the radiodetector were fixed at 3 and 9 c/s. Retention times for [18F]LBT-999 and the two radiometabolites detected by radio-UHPLC were 6.5, 4.8 and 9.6 min. Forty-five min after the injection, parent fraction was still predominant with 57.8% ± 25% of the total radioactivity. Conclusions: An innovative approach, allying UHPLC and Turboflow column, was developed and its sensitivity, linearity, specificity and repeatability validated. Preliminary results of the clinical trial are in accordance with literature data, demonstrating its efficiency in radiometabolites quantification.
文摘A highly sensitive, selective, and precise ultra-performance liquid chromatography tandem mass spectrometry method was developed and validated for simultaneous quantification of itraconazole and hydroxy itraconazole in human plasma by a single liquid-liquid extraction step. The precursor to product ion transitions of m/z 705.3/392.3, m/z 721.2/408.3 and m/z 708.2/435.4 were used to detect and quantify itraconazole, hydroxy itraconazole and itraconazole-d3 respectively. The lower limit of quantitation was found to be 0.500 ng/mL for itraconazole and 1.00 ng/mL for hydroxy itraconazole. The mean recoveries for itraconazole and hydroxy itraconazole were found to be 100.045% and 100.021%, respectively. This developed method with a chromatographic run time of 2.0 min was successfully applied to a bioequivalence study of 100 mg itraconazole capsule.
基金supported by National Key Research and Development Program of China(2018YFC1603400)。
文摘A rapid method was presented for the determination of 19 polyphenols in tea by ultra-high performance liquid chromatography coupled with quadrupole-time of flight mass spectrometry(UPLC-Q-TOF MS).Tea samples were extracted by 50%(V/V)ethanol,then separated by Waters Acquity BEH C18 column using a binary solvent system composed of acetonitrile and water(0.1%formic acid)by gradient elution.The analytes were determined by Q-TOF MS in TOF MS and information dependent acquisition(IDA)-MS/MS mode.The results showed that mass accuracy error of the 19 polyphenols were lower than 5.0×10^(-6),good linear relationship was got in range of 0.2–500μg/L and correlation coefficient was higher than 0.9990.The LOD was in the range of 0.002–0.100 mg/kg and the LOQ was in the range of 0.004–0.200 mg/kg.Recovery of the method was in range of 78.4%–109.2%with spike levels of 0.004–2.000 mg/kg,relative standard deviations were lower than 10%.The method was simple,rapid and accurate.It could be used for the rapid screening and quantitative analysis of 19 polyphenols in tea.
文摘Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.
基金Supported by the National Natural Science Foundation of China(No.30801513)the Knowledge Innovation Program of Chinese Academy of Sciences(No.KSCX2-YW-R-170)
文摘Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies.