A simple and sensitive kinetic spectrophotometric method for the determination of trace amounts of titanium(IV),based upon the catalytic effect of Ti(IV) on the oxidation of acid chrome blue K (ACBK) by hydrogen perox...A simple and sensitive kinetic spectrophotometric method for the determination of trace amounts of titanium(IV),based upon the catalytic effect of Ti(IV) on the oxidation of acid chrome blue K (ACBK) by hydrogen peroxide in 0.002 mol/L sulfuric acid,is described. The reaction rate is monitored spectrophotometrically by measuring the decrease in absorbance of ACBK at 524 nm. The detection limit of the method is 1.01×10?9 g/mL,and the linear range is 0-0.048 mg/L. The influence of acidity,concentration of reactants,reaction time,reaction temperature and for-eign ions is also discussed. The optimum reaction conditions were established and some kinetic parameters determined. The apparent activation energy of the catalytic reaction is 5.32 kJ/mol. The relative standard deviation for the determi-nation of titanium(IV) at the concentration of 0.048 mg/L is calculated to be 1.31% (n = 11). In combination with sol-vent extraction separation,the method has been successfully applied to the determination of trace titanium(IV) in human hair,plant matter,tea and rock samples. The results are in good agreement with the certified values with the relative standard deviations (RSD) of 1.4%-3.5%.展开更多
Based on the Mg^(2+)complexation with acid chrome blue K(ACBK)at pH 10.2,an automatic system was designed to determine total hardness of water.The system consists of a vector colorimeter,a multi-channel sampling pump ...Based on the Mg^(2+)complexation with acid chrome blue K(ACBK)at pH 10.2,an automatic system was designed to determine total hardness of water.The system consists of a vector colorimeter,a multi-channel sampling pump and both reagents A and B.Two kinds of reagent solutions were prepared and used in this system,i.e.,ammoniacal buffer and ACBK—disodium magnesium EDTA solutions.The experimental results of the standard solutions containing 2 and 3 mg/L of total hardness showed that the relative standard deviations(RSDs)were 1.9%and 2.2%,respectively,and the limit of detection(LOD)was only 0.035 mg/L.The detection of four natural water samples showed that the recoveries were between 85.0%and 108.6%,consistent with those obtained by ICP-AES method.展开更多
基金Project 0520002 supported by the Natural Science Foundation of Jiangxi Province
文摘A simple and sensitive kinetic spectrophotometric method for the determination of trace amounts of titanium(IV),based upon the catalytic effect of Ti(IV) on the oxidation of acid chrome blue K (ACBK) by hydrogen peroxide in 0.002 mol/L sulfuric acid,is described. The reaction rate is monitored spectrophotometrically by measuring the decrease in absorbance of ACBK at 524 nm. The detection limit of the method is 1.01×10?9 g/mL,and the linear range is 0-0.048 mg/L. The influence of acidity,concentration of reactants,reaction time,reaction temperature and for-eign ions is also discussed. The optimum reaction conditions were established and some kinetic parameters determined. The apparent activation energy of the catalytic reaction is 5.32 kJ/mol. The relative standard deviation for the determi-nation of titanium(IV) at the concentration of 0.048 mg/L is calculated to be 1.31% (n = 11). In combination with sol-vent extraction separation,the method has been successfully applied to the determination of trace titanium(IV) in human hair,plant matter,tea and rock samples. The results are in good agreement with the certified values with the relative standard deviations (RSD) of 1.4%-3.5%.
基金supported by both the Foundation(PCRRK21005)of State Key Laboratory of Pollution Control and Resource Reuse(Tongji University)The National Key Research and Development Program of China(2019YFC1805300)
文摘Based on the Mg^(2+)complexation with acid chrome blue K(ACBK)at pH 10.2,an automatic system was designed to determine total hardness of water.The system consists of a vector colorimeter,a multi-channel sampling pump and both reagents A and B.Two kinds of reagent solutions were prepared and used in this system,i.e.,ammoniacal buffer and ACBK—disodium magnesium EDTA solutions.The experimental results of the standard solutions containing 2 and 3 mg/L of total hardness showed that the relative standard deviations(RSDs)were 1.9%and 2.2%,respectively,and the limit of detection(LOD)was only 0.035 mg/L.The detection of four natural water samples showed that the recoveries were between 85.0%and 108.6%,consistent with those obtained by ICP-AES method.