期刊文献+
共找到34,094篇文章
< 1 2 250 >
每页显示 20 50 100
关于*r-clean环
1
作者 覃健 应志领 周华 《华东师范大学学报(自然科学版)》 CAS CSCD 北大核心 2024年第2期30-32,共3页
称对合环为*r-clean环是指环中任一元素都可表示为投射子和*-正则元的和.研究了该环的一些扩张性质,并给出了*-阿贝尔的*r-clean环中元素的刻画.
关键词 *r-clean *-clean *-正则环
下载PDF
New steelmaking process based on clean deoxidation technology
2
作者 Zhongliang Wang Yanping Bao 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第6期1249-1262,共14页
After the converter steelmaking process,a considerable number of ferroalloys are needed to remove dissolved oxygen from the molten steel,but it also forms a lot of oxide inclusions that cannot be completely removed.At... After the converter steelmaking process,a considerable number of ferroalloys are needed to remove dissolved oxygen from the molten steel,but it also forms a lot of oxide inclusions that cannot be completely removed.At the same time,it increases the carbon emis-sions in the steel production process.After years of research,our team have developed a series of clean deoxidation technologies,includ-ing carbon deoxidation,hydrogen deoxidation,and waste plastic deoxidation of molten steel to address the aforementioned issues.In this study,thermodynamic calculations and laboratory experiments were employed to verify that carbon and hydrogen can reduce the total oxygen content in the molten steel melt to below 5×10^(-6) and 10×10^(-6),respectively.An analysis of the deoxidation mechanisms and ef-fects of polyethylene and polypropylene was also conducted.In addition,the applications of carbon deoxidation technology in different steels with the hot-state experiment and industrial production were discussed carefully.The carbon deoxidation experimental results of different steels were as follows:(1)the oxygen content of bearing steel was effectively controlled at 6.3×10^(-6) and the inclusion number density was lowered by 74.73%compared to aluminum deoxidized bearing steel;(2)the oxygen content in gear steel was reduced to 7.7×10^(-6) and a 54.49%reduction of inclusion number density was achieved with almost no inclusions larger than 5μm from the average level of industry gear steels;(3)a total oxygen content of M2 high-speed steel was as low as 3.7×10^(-6).In industrial production practice,car-bon deoxidation technique was applied in the final deoxidation stage for non-aluminum deoxidized bearing steel,and it yielded excellent results that the oxygen content was reduced to below 8×10^(-6) and the oxide inclusions in the steel mainly consist of silicates,along with small amounts of spinel and calcium aluminate. 展开更多
关键词 clean deoxidation carbon deoxidation hydrogen deoxidation waste plastics deoxidation
下载PDF
Experimental investigation on coal pore-fracture variation and fractal characteristics synergistically affected by solvents for improving clean gas extraction
3
作者 Feilin Han Sheng Xue +3 位作者 Chunshan Zheng Zhongwei Chen Guofu Li Bingyou Jiang 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第3期413-425,共13页
Chemical solvents instead of pure water being as hydraulic fracturing fluid could effectively increase permeability and improve clean methane extraction efficiency.However,pore-fracture variation features of lean coal... Chemical solvents instead of pure water being as hydraulic fracturing fluid could effectively increase permeability and improve clean methane extraction efficiency.However,pore-fracture variation features of lean coal synergistically affected by solvents have not been fully understood.Ultrasonic testing,nuclear magnetic resonance analysis,liquid phase mass spectrometry was adopted to comprehensively analyze pore-fracture change characteristics of lean coal treated by combined solvent(NMP and CS_(2)).Meanwhile,quantitative characterization of above changing properties was conducted using geometric fractal theory.Relationship model between permeability,fractal dimension and porosity were established.Results indicate that the end face fractures of coal are well developed after CS2and combined solvent treatments,of which,end face box-counting fractal dimensions range from 1.1227 to 1.4767.Maximum decreases in ultrasonic longitudinal wave velocity of coal affected by NMP,CS_(2)and combined solvent are 2.700%,20.521%,22.454%,respectively.Solvent treatments could lead to increasing amount of both mesopores and macropores.Decrease ratio of fractal dimension Dsis 0.259%–2.159%,while permeability increases ratio of NMR ranges from 0.1904 to 6.4486.Meanwhile,combined solvent could dissolve coal polar and non-polar small molecules and expand flow space.Results could provide reference for solvent selection and parameter optimization of permeability-enhancement technology. 展开更多
关键词 clean gas extraction Chemical solvent Experimental investigation Fractal characteristics Pore fracture
下载PDF
Wellbore Cleaning Degree and Hydraulic Extension in Shale Oil Horizontal Wells
4
作者 Xin Ai Mian Chen 《Fluid Dynamics & Materials Processing》 EI 2024年第3期661-670,共10页
The efficient development and exploitation of shale oil depends on long-distance horizontal wells. As the degreeof cleaning of the wellbore plays a key role in these processes, in this study, this problem is investiga... The efficient development and exploitation of shale oil depends on long-distance horizontal wells. As the degreeof cleaning of the wellbore plays a key role in these processes, in this study, this problem is investigated experimentallyby focusing on the dimensionless cuttings bed height. A method is proposed to calculate the horizontalwellhydraulic extension taking into account the influence of the wellbore cleaning degree on the wellborepressure distribution and assess the effect of a variety of factors such as the bottom hole pressure, the circulatingpressure drop, the drilling pump performance and the formation properties. The analysis shows that the hydraulicextension of horizontal wells decreases with an increase in the cuttings bed height, and the higher the displacementof drilling fluid, the faster the hydraulic extension declines. The annular pressure drop of the horizontalsection increases with the increase of the cuttings bed height, resulting in a higher bottom-hole pressure. Severalarguments are provided to guide the safe drilling of shale oil horizontal wells and overcome the limits of currenttechnological approaches. 展开更多
关键词 Shale oil horizontal well hydraulic extension wellbore cleaning degree pressure distribution mechanism analysis
下载PDF
满足DNV船级符号Clean(Design)要求的轮机设备订货及系统设计
5
作者 刘钢 沈英 +2 位作者 倪建伟 唐传安 唐志杰 《船舶与海洋工程》 2024年第2期54-59,共6页
为有效避免在船舶产品设计过程中出现疏漏,研究挪威船级社船级符号Clean(Design)对轮机设备订货、系统设计和舱柜布置的最新要求,并对各设备和系统的特殊要求及设计原则进行梳理和归纳。用于处理污染物的设备主要包括油水分离器、污水... 为有效避免在船舶产品设计过程中出现疏漏,研究挪威船级社船级符号Clean(Design)对轮机设备订货、系统设计和舱柜布置的最新要求,并对各设备和系统的特殊要求及设计原则进行梳理和归纳。用于处理污染物的设备主要包括油水分离器、污水处理装置和焚烧炉,涉及的船舶系统主要包括舱底水系统、生活污水处理系统、泡沫灭火系统和艉管滑油系统等。该研究可供满足该规范要求的环保型船舶产品的设计参考。 展开更多
关键词 船级符号clean(Design) 设备订货 综合舱底水处理系统 系统设计
下载PDF
Overview of Factors Affecting Dust Deposition on Photovoltaic Cells and Cleaning Methods
6
作者 Mamadou Tamboura Ekaterina Alexandrovna Gosteva 《Smart Grid and Renewable Energy》 2024年第1期49-78,共30页
Dust deposition on the surface of photovoltaic (PV) cells poses a significant challenge to their efficiency, especially in arid regions characterized by desert and semi-desert conditions. Despite the pronounced impact... Dust deposition on the surface of photovoltaic (PV) cells poses a significant challenge to their efficiency, especially in arid regions characterized by desert and semi-desert conditions. Despite the pronounced impact of dust accumulation, these regions offer optimal solar radiation and minimal cloud cover, making them ideal candidates for widespread PV cell deployment. Various surface cleaning methods exist, each employing distinct approaches. Choosing an appropriate cleaning method requires a comprehensive understanding of the mechanisms involved in both dust deposition on module surfaces and dust adhesion to PV cell surfaces. The mechanisms governing dust deposition and adhesion are complex and multifaceted, influenced by factors such as the nature and properties of the dust particles, environmental climatic conditions, characteristics of protective coatings, and the specific location of the PV installation. These factors exhibit regional variations, necessitating the implementation of diverse cleaning approaches tailored to the unique conditions of each location. The first part of this article explores the factors influencing dust deposition on PV cell surfaces, delving into the intricate interplay of environmental variables and particle characteristics. Subsequently, the second part addresses various cleaning methods, offering an analysis of their respective advantages and disadvantages. By comprehensively examining the factors influencing dust accumulation and evaluating the effectiveness of different cleaning strategies, this article aims to contribute valuable insights to the ongoing efforts to optimize the performance and longevity of photovoltaic systems in diverse geographical contexts. 展开更多
关键词 Solar Energy Dust Deposition cleaning Methods
下载PDF
Analysis of the Appealing Structure in Hemingway’s“A Clean,Well-lighted Place”
7
作者 LI Xing-yue 《Journal of Literature and Art Studies》 2024年第3期201-206,共6页
In the novel“A Clean,Well-lighted Place”,Hemingway tells the story of two waiters in a Spanish caféjust before closing time,talking about an old man who drank heavily in the caféevery night and lived a wea... In the novel“A Clean,Well-lighted Place”,Hemingway tells the story of two waiters in a Spanish caféjust before closing time,talking about an old man who drank heavily in the caféevery night and lived a wealthy life but still wants to commit suicide.Using the iceberg principle,Hemingway purposely omits the plot,characterization of the story,and uses symbolism and repetition to describe people’s different attitudes facing the spiritual emptiness after the war,breaking the readers’expectations,and inspiring them to explore the meaning of individual life.Therefore,based on Wolfgang Iser and Zhu Liyuan’s appealing structure theory,this paper will analyze the appealing structure in“A Clean,Well-lighted Place”at three levels:meaning construction,rhetorical techniques,and thoughts and themes.It is hoped that readers can find a new way to interpret the short story,better understand the author’s creative ideas and dig deeper into the connotation of the work. 展开更多
关键词 Ernest Hemingway “A clean Well-lighted Place” appealing structure
下载PDF
关于正则环和拟clean环的一个注记
8
作者 罗丽华 陈晓珊 唐高华 《南宁师范大学学报(自然科学版)》 2024年第1期12-14,共3页
如果对环R中的每个元素a,都存在u∈R使得aua=a,则称R为正则环.如果环R中的每个元素都可分解成一个拟幂等元与一个单位之和,则称R为拟clean环.该文构造了一个列有限矩阵环,说明正则环不一定是拟clean的.
关键词 正则环 clean clean
下载PDF
A Clean Switch Inner Mongolian town takes giant steps in transitioning to clean energy production
9
作者 XIA YUANYUAN 《ChinAfrica》 2024年第5期34-36,共3页
Staff at the Ruichen Wanniu Livestock Farm in Jungar Zhao Town,Jungar Banner,Inner Mongolia,are consistently busy,even during important festivals.
关键词 clean STEPS BANNER
下载PDF
Performance Evaluation of Low-Carbon and Clean Transformation of China’s Coal Economy
10
作者 Liangfeng Zhu 《Journal of Environmental Science and Engineering(B)》 2024年第1期21-38,共18页
In China,the oversupply of coal occurred in 2009,and from that year onwards,China’s coal economy began a low-carbon and clean transformation.Evaluating transformation performance is the research goal of this paper.Th... In China,the oversupply of coal occurred in 2009,and from that year onwards,China’s coal economy began a low-carbon and clean transformation.Evaluating transformation performance is the research goal of this paper.The data collection for this paper includes data on deep processing of Chinese coal products from 2009 to 2020,as well as data on asset structure evolution and financial performance of 34 listed companies in the Chinese coal mining.Entropy value method is used to calculate the entropy value of low-carbon transformation,and the regression analysis is used to study the performance of cleaner transformation,the conclusion is as follows:(1)From 2009 to 2020,in China’s total energy consumption,coal consumption accounted for 71.6%in 2009 and 56.8%in 2020,the goals set by the state have been achieved.(2)The national goal of reducing the proportion of coal consumption and reducing carbon emissions has forced the transformation of deep processing of coal products.The transformation of coal enterprises towards low-carbon and clean production has achieved remarkable results.(3)From 2009 to 2020,the non coal industry income of 34 listed companies in China’s coal mining industry increased by 8.21%annually.At the same time,the asset structure was adjusted,and nearly 80%of the asset structure evolution showed an orderly development trend.(4)The regression analysis results show that the entropy value of coal deep processing products and the entropy value of asset structure adjustment are significantly related to transformation performance.The paper proposes to summarize the successful experience of China’s coal energy economic transformation,lay a foundation for achieving the carbon peak and carbon neutral goals in the future,further increase the intensity of coal deep processing,increase the proportion of clean energy in total energy consumption,and strive to control asset operation towards the goal of increasing the proportion of non coal industry income. 展开更多
关键词 Coal economy low-carbon and clean transformation deep processing of coal evolution of asset structure performance appraisal
下载PDF
J^(#)-U_(c)-clean环与强J^(#)-U_(c)-clean环
11
作者 靳丹亚 黄涛 崔建 《南通大学学报(自然科学版)》 CAS 2024年第1期87-94,共8页
设R是一个环,如果U(R)=U_(c)(R)+J^(#)(R),则称R是GU_(c)J环;如果对于任意a∈R,都存在g∈U_(c)(R),p^(2)=p∈R,d∈J^(#)(R)使得ag=p+d(且ap=pa),则称R是(强)J^(#)-U_(c)-clean环。GU_(c)J环和J^(#)-U_(c)-clean环分别是GUJ环和GJ-clean... 设R是一个环,如果U(R)=U_(c)(R)+J^(#)(R),则称R是GU_(c)J环;如果对于任意a∈R,都存在g∈U_(c)(R),p^(2)=p∈R,d∈J^(#)(R)使得ag=p+d(且ap=pa),则称R是(强)J^(#)-U_(c)-clean环。GU_(c)J环和J^(#)-U_(c)-clean环分别是GUJ环和GJ-clean环的真推广。文章研究了GU_(c)J环的基本性质,证明了R是GU_(c)J环当且仅当R/J是U_(c)U环且U_(c)(R/J)=(U_(c)(R)+J)/J,R是U_(c)J环当且仅当R是GU_(c)J环且R/J是reduced的。此外,给出了(强)J^(#)-U_(c)-clean环的例子,得到了(强)J^(#)-U_(c)-clean环的性质和一些等价刻画,证明了若R是一个交换环,则R是GJ-clean环当且仅当存在整数n≥1使得T_(n)(R)是GJ-clean环,当且仅当存在整数n≥2使得T_(n)(R)是J^(#)-U_(c)-clean环。进一步地,研究了强J^(#)-U_(c)-clean环的Morita不变性。 展开更多
关键词 GUJ环 GJ-clean GU_(c)J环 J^(#)-U_(c)-clean 强J^(#)-U_(c)-clean
下载PDF
NGR-clean环
12
作者 王志强 吴俊 《宿州学院学报》 2024年第3期9-14,21,共7页
若环R中的任意元素都能表示成一个(强)π-正则元和一个幂零元之和,则称环R是(强)NGR-clean环。研究给出(强)NGR-clean环的一些基本性质,证明了若I是环R的诣零理想,则R是NGR-clean环当且仅当R/I是NGR-clean环。此外,还研究了(强)NGR-clea... 若环R中的任意元素都能表示成一个(强)π-正则元和一个幂零元之和,则称环R是(强)NGR-clean环。研究给出(强)NGR-clean环的一些基本性质,证明了若I是环R的诣零理想,则R是NGR-clean环当且仅当R/I是NGR-clean环。此外,还研究了(强)NGR-clean环与一些环类之间的联系以及(强)NGR-clean环的几类扩张。 展开更多
关键词 NR-clean Π-正则环 NGR-clean 强NGR-clean
下载PDF
Entropy Assessment on Environmental Influence of Condense Heat in Recovery System in Air-Conditioning Refrigerating Machine 被引量:2
13
作者 TANG Wen-wu1,2,WANG Han-qing1,2(1.School of Energy Science and Engineering,Central South University,Changsha,Hunan 410083,China 2.School of Civil Engineering,Hunan University of Technology,Zhuzhou,Hunan 412008,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期96-101,共6页
This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ... This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%). 展开更多
关键词 air-conditioning refrigerating MACHINE condense HEAT ENTROPY evaluation LS-SVM
下载PDF
Impact of summer office set air-conditioning temperature on energy consumption and thermal comfort 被引量:3
14
作者 刘红 马小磊 高亚峰 《Journal of Central South University》 SCIE EI CAS 2009年第S1期6-11,共6页
To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three... To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes. 展开更多
关键词 air-conditioning TEMPERATURE thermal COMFORT air-conditIONER energy consumption NEUTRAL TEMPERATURE acceptable TEMPERATURE
下载PDF
Selection of Weather Parameters for Air-Conditioning System Design for Buildings with Long Thermal Lag 被引量:1
15
作者 GE Lian-feng1,2,LEI Ming3,CHEN You-ming1,2(1.College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China 2.Key Laboratory of Building Safety and Energy Efficiency,MOE,China (3.Aviation Theory Department,Aviation University of Air Force,Changchun,Jilin 130022,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期79-82,共4页
Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling lo... Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant. 展开更多
关键词 building construction THERMAL LAG system capacity design WEATHER data air-conditioning
下载PDF
The Experiment and Simulation of Solid Desiccant Dehumidification for Air-Conditioning System in a Tropical Humid Climate 被引量:1
16
作者 Juntakan Taweekun Visit Akvanich 《Engineering(科研)》 2013年第1期146-153,共8页
The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different ... The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different dehumidifiers such as desiccant column and desiccant wheel were investigated. The ANSYS and TRASYS software were used to predict the results of dehumidifiers and the desiccant cooling systems, respectively. The desiccant bed contained approximately 15 kg of silica-gel, with 3 mm average diameter. Results indicated that the pressure drop and the adsorption rate of desiccant column are usually higher than those of the desiccant wheel. The feasible and practical adsorption rate of desiccant wheel was 0.102 kgw/h at air flow rate 1.0 kg/min, regenerated air temperature of 55?C and at a wheel speed of 2.5 rpm. The humidity ratio of conditioning space and cooling load of split-type air conditioner was decreased to 0.002 kgw/kgda (14%) and 0.71 kWth (19.26%), respectively. Consequently, the thermal comfort was improved from 0.5 PMV (10.12% PPD) to 0.3 PMV (7.04% PPD). 展开更多
关键词 SOLID DESICCANT DEHUMIDIFICATION air-conditioning System TROPICAL Humid CLIMATE
下载PDF
An Energy-Saving Control Strategy on Central Air-Conditioning System 被引量:1
17
作者 Sheng Xing 1 , Yin Juan 2 , Shang Jingfu 3 , Yu Yang 4 , Wu Zhangxian 5 1. State Grid Information & Telecommunication Co., Ltd. 2. China Huadian Finance Corporation Limited 3. State Grid AC Engineering Construction Company 4. Northeast China Electric Power Dispatching & Communication Center 5. North China Electric Power University 《Electricity》 2011年第4期62-66,共5页
An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature con... An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy. 展开更多
关键词 central air-conditioning predictive control energy saving time-delay system simulated annealing
下载PDF
基于CLEAN算法的自适应旁瓣对消技术
18
作者 柴许杨 赵志国 +1 位作者 岳玫君 刘野 《雷达科学与技术》 北大核心 2023年第5期526-530,538,共6页
自适应旁瓣对消技术能够很好地抑制旁瓣干扰,但在应用中发现,自适应旁瓣对消对跟踪的高信噪比目标带来的信噪比损失较大,导致单脉冲和差测角精度下降。本文提出了一种基于CLEAN算法的自适应旁瓣对消方法,首先通过观测目标的先验信息构... 自适应旁瓣对消技术能够很好地抑制旁瓣干扰,但在应用中发现,自适应旁瓣对消对跟踪的高信噪比目标带来的信噪比损失较大,导致单脉冲和差测角精度下降。本文提出了一种基于CLEAN算法的自适应旁瓣对消方法,首先通过观测目标的先验信息构建目标回波模型,再利用该回波模型剔除对消通道中的目标信息,然后基于剔除目标信息后的对消通道数据,重新计算最优加权值进行主通道的干扰对消,最后仿真和实测结果验证了该方法不仅可以减少主通道中目标对消后的信噪比损失,同时也降低了对消后对目标测角精度的影响。 展开更多
关键词 信号处理 旁瓣对消 clean算法 和差测角
下载PDF
Application of Fuzzy Comprehensive Evaluation to Air-conditioning Competitive Power Analysis
19
作者 LU Congda LIU Gaojin JIANG Shaofei LV Chaoqun (The MOE Key Laboratory of Mechanical Manufacture and Automation,Zhejiang University of Technology,Hangzhou 310032,China 《武汉理工大学学报》 CAS CSCD 北大核心 2006年第S2期463-467,共5页
As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD),cus- tomer requirements should be understood and the product competitive power be analyzed as exactly as possi... As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD),cus- tomer requirements should be understood and the product competitive power be analyzed as exactly as possible for new product de- signing.Lots of information in the process of this research is fuzzy and uncertain,but traditional QFD can not deal with it well. Fuzzy theory can solve the problem.So a fuzzy model for analyzing product competitive power is formulated in this paper to im- prove traditional QFD,after that it is applied to analyze air-conditioning competitive power.When air-conditioning competitive power is analyzed using this model,firstly the importance weight of the customer requirements o fair-conditioning is determined us- ing the Analytic Hierarchy Process (AHP) weighting process,then air-conditloning competitive power is evaluated using fuzzy comprehensive evaluation.It is proved that the model is feasible and has good applicability. 展开更多
关键词 air-conditioning COMPETITIVE power QFD AHP FUZZY COMPREHENSIVE evaluation
下载PDF
Application of Dual Throttling Air-Conditioning System to Explosion-Proof Frequency Converter
20
作者 张于峰 高岩 盛颖 《Transactions of Tianjin University》 EI CAS 2015年第2期95-103,共9页
An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study inv... An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study investigated the feasibility and benefits of explosion-proof dual throttling cooling and dehumidification air-conditioning system applied to the explosion-proof frequency converter. The physical model of dual throttling air-conditioning system was established and its performance parameter was described by mathematical method. The design calculation of the system has also been done. The experimental result showed that the system reached the steady state at the refrigeration mode after running 45 min, and the maximum internal temperature of the flame-proof cavity was 31.0 ℃. The system reached the steady state at the dehumidification mode after running 37 min. The maximum internal relative humidity and temperature of the flame-proof cavity were 33.4% and 36.3 ℃, respectively. Therefore, the proposed system had excellent ability of heat dissipation and avoided internal dewing. Compared with water cooling system, it was more energy-saving and economical. The airflow field of dual throttling air-conditioning system was also studied by CFD simulation. It was found that the result of CFD numerical simulation was highly consistent with the experimental data. 展开更多
关键词 EXPLOSION-PROOF CONVERTER DUAL throttling air-conditioning CFD energy SAVING heat DISSIPATION dewing
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部