In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter z...In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter zone of Southern Shaanxi. Through the calculation of heat transfer coefficient and thermal inertia index, combined with the specifications of the shale hollow brick and aerated concrete block of Hanzhong and Ankang in southern Shaanxi, the thermal performance and suitable thickness of the external wall using self-insulation materials that meet the Design Standard for Energy Efficiency of Residential Buildings(DBJ61-65-2011) in Shaanxi Province were obtained. The results showed that the self-insulation wall had technical suitability in the hot summer and cold winter zone. The research results provide not only a theoretical basis for the external wall insulation design of urban residential buildings in the hot summer and cold winter zone of southern Shaanxi, but also a reference for designers to carry out energy-saving design of external walls of residential buildings in other similar climate zones.展开更多
The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation o...The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation of the exterior?wall is a more feasible design to satisfy the energy efficiency of buildings in the?zone. However, the systematic research is urgently needed for the self-insulation of the exterior wall in the hot summer and cold winter zone of China. The paper tested the thermal performance of the common non-clay materials such as shale sintered hollow brick, sand autoclaved aerated concrete block, etc. by means of indoor experiments. The energy efficiency effect of the common materials was verified using dynamic calculation soft PKPM and several constitutions of exterior wall with different main bricks and insulation materials on the heat bridge were simulated, too. Besides, the tests of the thermal performance of exterior wall in real constructions were carried out to testify the practical effect of the recommended constitutions of exterior wall with different main bricks and insulation materials on the heat bridge. The conclusions are: the physical and thermal properties of the six non-clay wall material are better than the clay porous brick;the thermal performance of the non-clay brick can be improved obviously through the rational arrangement of the holes;shale sintered hollow brick after increasing the holes and rationalizing the hole arrangement and sand autoclaved aerated concrete block are recommended for buildings in the hot summer and cold winter area of China. The dynamic calculation results show that the thermal performances?of the non-clay materials are all satisfied with the energy efficiency;The heat transfer coefficient of the exterior wall with composition?③,?in which?the main wall was sand autoclaved aerated concrete block and the material on the heat bridge was sand autoclaved aerated concrete plate, is the smallest among the three recommended compositions.展开更多
In China, rural residential environment under the poor construction measures has not been satisfactory due to the backward infrastructure of countryside and the lacking of professional planning, which will result in c...In China, rural residential environment under the poor construction measures has not been satisfactory due to the backward infrastructure of countryside and the lacking of professional planning, which will result in considerable amount of energy consumption in the future. The economy of rural residences in the hot summer and cold winter region of China is relative developed, but the indoor thermal environmental quality is not so good. In this paper, the design strategies directed by passive design ideas for a small experimental rural residential building located in Hangzhou city was introduced and researched in response to hot summer and cold winter climate. Through modeling solution undertaken by Ecotect software, the building performance was simulated and analyzed for the optimization of design factors, such as shape, roof angle, insulation system, shading devices, as well as day-lighting system. Based on the above study, a set of appropriate energy-saving technologies were provided for improving the new rural residences construction in Hangzhou, which should also be recommended to other projects constructed in the same climate region.展开更多
Carbon sequestration and emission reduction in the construction industry plays an important role in China’s goal of achieving carbon neutrality.Research in Zhuzhou city scored 42 since the assessment of the green bui...Carbon sequestration and emission reduction in the construction industry plays an important role in China’s goal of achieving carbon neutrality.Research in Zhuzhou city scored 42 since the assessment of the green building project situation as the research object,in hot summer and cold winter areas of analysis and evaluation on the development of green building technology,and then sums up the carbon neutral background the priority areas and tasks for the development of green building techniques,optimization of the construction industry into a new era under the background of green development to provide the reference.展开更多
Double-skin facades(DSF)are a technique developed for colder climates,so few people think about whether or not it can also be used for hot-summer and cold-winter zones in China.After analyzing the problems of using DS...Double-skin facades(DSF)are a technique developed for colder climates,so few people think about whether or not it can also be used for hot-summer and cold-winter zones in China.After analyzing the problems of using DSF for hot-summer zones,this paper explored on the possibility of applying DSF in hot-summer and cold-winter zones in China.The main existing research methods for DSF were also collected and commented.If properly managed,the ventilated DSF with controlled shading devices can be used even in hot summer in China.展开更多
China experienced significant flooding in the summer of 2020 and multiple extreme cold surges during the winter of 2020/21.Additionally,the 2020 typhoon season had below average activity with especially quiet activity...China experienced significant flooding in the summer of 2020 and multiple extreme cold surges during the winter of 2020/21.Additionally,the 2020 typhoon season had below average activity with especially quiet activity during the first half of the season in the western North Pacific(WNP).Sea surface temperature changes in the Pacific,Indian,and Atlantic Oceans all contributed to the heavy rainfall in China,but the Atlantic and Indian Oceans seem to have played dominant roles.Enhancement and movement of the Siberian High caused a wavier pattern in the jet stream that allowed cold polar air to reach southward,inducing cold surges in China.Large vertical wind shear and low humidity in the WNP were responsible for fewer typhoons in the first half of the typhoon season.Although it is known that global warming can increase the frequency of extreme weather and climate events,its influences on individual events still need to be quantified.Additionally,the extreme cold surge during 16–18 February 2021 in the United States shares similar mechanisms with the winter 2020/21 extreme cold surges in China.展开更多
This study monitors the open/closed states of the windows in 16 residential apartments in representative cities of the hot summer and cold winter zone of China,along with outdoor air temperature,outdoor relative humid...This study monitors the open/closed states of the windows in 16 residential apartments in representative cities of the hot summer and cold winter zone of China,along with outdoor air temperature,outdoor relative humidity and outdoor PM2.5 concentration in 2017,to investigate the window opening/closing behavior.Three window opening models are developed.All the models are validated by modeling a typical residential apartment to compare the predicted indoor CO_(2)concentration with monitored data.It is found that the window opening probability is negatively correlated to both outdoor PM2.5 concentration and outdoor relative humidity,and the probability of window opening reaches the peak value when the outdoor air temperature is 23.7℃.In terms of season,the shortest window opening duration occurs in winter due to the cold outdoor air temperature and high outdoor PM2.5 concentration.Finally,by comparing the correlation between the measured date and simulation results of indoor CO_(2)concentration,this study provides an appropriate window opening model for reference.展开更多
文摘In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter zone of Southern Shaanxi. Through the calculation of heat transfer coefficient and thermal inertia index, combined with the specifications of the shale hollow brick and aerated concrete block of Hanzhong and Ankang in southern Shaanxi, the thermal performance and suitable thickness of the external wall using self-insulation materials that meet the Design Standard for Energy Efficiency of Residential Buildings(DBJ61-65-2011) in Shaanxi Province were obtained. The results showed that the self-insulation wall had technical suitability in the hot summer and cold winter zone. The research results provide not only a theoretical basis for the external wall insulation design of urban residential buildings in the hot summer and cold winter zone of southern Shaanxi, but also a reference for designers to carry out energy-saving design of external walls of residential buildings in other similar climate zones.
文摘The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation of the exterior?wall is a more feasible design to satisfy the energy efficiency of buildings in the?zone. However, the systematic research is urgently needed for the self-insulation of the exterior wall in the hot summer and cold winter zone of China. The paper tested the thermal performance of the common non-clay materials such as shale sintered hollow brick, sand autoclaved aerated concrete block, etc. by means of indoor experiments. The energy efficiency effect of the common materials was verified using dynamic calculation soft PKPM and several constitutions of exterior wall with different main bricks and insulation materials on the heat bridge were simulated, too. Besides, the tests of the thermal performance of exterior wall in real constructions were carried out to testify the practical effect of the recommended constitutions of exterior wall with different main bricks and insulation materials on the heat bridge. The conclusions are: the physical and thermal properties of the six non-clay wall material are better than the clay porous brick;the thermal performance of the non-clay brick can be improved obviously through the rational arrangement of the holes;shale sintered hollow brick after increasing the holes and rationalizing the hole arrangement and sand autoclaved aerated concrete block are recommended for buildings in the hot summer and cold winter area of China. The dynamic calculation results show that the thermal performances?of the non-clay materials are all satisfied with the energy efficiency;The heat transfer coefficient of the exterior wall with composition?③,?in which?the main wall was sand autoclaved aerated concrete block and the material on the heat bridge was sand autoclaved aerated concrete plate, is the smallest among the three recommended compositions.
文摘In China, rural residential environment under the poor construction measures has not been satisfactory due to the backward infrastructure of countryside and the lacking of professional planning, which will result in considerable amount of energy consumption in the future. The economy of rural residences in the hot summer and cold winter region of China is relative developed, but the indoor thermal environmental quality is not so good. In this paper, the design strategies directed by passive design ideas for a small experimental rural residential building located in Hangzhou city was introduced and researched in response to hot summer and cold winter climate. Through modeling solution undertaken by Ecotect software, the building performance was simulated and analyzed for the optimization of design factors, such as shape, roof angle, insulation system, shading devices, as well as day-lighting system. Based on the above study, a set of appropriate energy-saving technologies were provided for improving the new rural residences construction in Hangzhou, which should also be recommended to other projects constructed in the same climate region.
基金supported by the Hunan Provincial and Municipal Joint Fund(No.2022JJ50069).
文摘Carbon sequestration and emission reduction in the construction industry plays an important role in China’s goal of achieving carbon neutrality.Research in Zhuzhou city scored 42 since the assessment of the green building project situation as the research object,in hot summer and cold winter areas of analysis and evaluation on the development of green building technology,and then sums up the carbon neutral background the priority areas and tasks for the development of green building techniques,optimization of the construction industry into a new era under the background of green development to provide the reference.
文摘Double-skin facades(DSF)are a technique developed for colder climates,so few people think about whether or not it can also be used for hot-summer and cold-winter zones in China.After analyzing the problems of using DSF for hot-summer zones,this paper explored on the possibility of applying DSF in hot-summer and cold-winter zones in China.The main existing research methods for DSF were also collected and commented.If properly managed,the ventilated DSF with controlled shading devices can be used even in hot summer in China.
基金the National Natural Science Foundation of China(Grant No.41731173)the National Key R&D Program of China(Grant No.2019YFA0606701)+2 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant Nos.XDB42000000 and XDA20060502)the Key Special Project for Introduced Talents Team of Southern Marine Science and Engineering Guangdong Laboratory(Guangzhou)(Grant No.GML2019ZD0306)the Innovation Academy of South China Sea Ecology and Environmental Engineering,the Chinese Academy of Sciences(Grant No.ISEE2018PY06)。
文摘China experienced significant flooding in the summer of 2020 and multiple extreme cold surges during the winter of 2020/21.Additionally,the 2020 typhoon season had below average activity with especially quiet activity during the first half of the season in the western North Pacific(WNP).Sea surface temperature changes in the Pacific,Indian,and Atlantic Oceans all contributed to the heavy rainfall in China,but the Atlantic and Indian Oceans seem to have played dominant roles.Enhancement and movement of the Siberian High caused a wavier pattern in the jet stream that allowed cold polar air to reach southward,inducing cold surges in China.Large vertical wind shear and low humidity in the WNP were responsible for fewer typhoons in the first half of the typhoon season.Although it is known that global warming can increase the frequency of extreme weather and climate events,its influences on individual events still need to be quantified.Additionally,the extreme cold surge during 16–18 February 2021 in the United States shares similar mechanisms with the winter 2020/21 extreme cold surges in China.
基金Part of the work is supported by National Science Foundation of China(51878408,51508326)the Key laboratory of healthy en-vironment and energy conservation for industrial large space building(2019SA-10-07)This work is supported by the national key project of the Ministry of Science and Technology,China,on“Green Buildings and Building Industrialization”through Grant No.2016YFC0700500.
文摘This study monitors the open/closed states of the windows in 16 residential apartments in representative cities of the hot summer and cold winter zone of China,along with outdoor air temperature,outdoor relative humidity and outdoor PM2.5 concentration in 2017,to investigate the window opening/closing behavior.Three window opening models are developed.All the models are validated by modeling a typical residential apartment to compare the predicted indoor CO_(2)concentration with monitored data.It is found that the window opening probability is negatively correlated to both outdoor PM2.5 concentration and outdoor relative humidity,and the probability of window opening reaches the peak value when the outdoor air temperature is 23.7℃.In terms of season,the shortest window opening duration occurs in winter due to the cold outdoor air temperature and high outdoor PM2.5 concentration.Finally,by comparing the correlation between the measured date and simulation results of indoor CO_(2)concentration,this study provides an appropriate window opening model for reference.